Attached/Detached Patio Cover/Carport

Similar documents
STANDARD OPEN PATIO COVER

Patio Covers / Carports

TYPICAL PATIO COVERS 111

Residential Decks. Planning and Development Services Department

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Residential Deck Safety, Construction, and Repair

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Uncovered Decks & Porches

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

1/2" CDX PLY W/ 6"/ 6"/ 12" 2x ROOF 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

Sample Drawing Package for One and Two Family Dwelling Applications

Section A Roof Truss

A Guide to Detached Residential Garages and Residential Workshops (based on 2006 BCBC)

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

RESIDENTIAL WOOD DECKS

POST AND FRAME STRUCTURES (Pole Barns)

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

Single Family Residential Building Permit Questions & Answers

Basic Requirements for Residential Plan Review _

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Residential Building Permits

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Mark Cramer Inspection Services, Inc.

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Page & Turnbull imagining change in historic environments through design, research, and technology

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Residential Building Permit Process

Asphalt Shingle Application Requirements

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Additions and Alterations

Architectural Control Guidelines

The City of Basehor, Kansas

d. Building permits may only be approved if consistent with the approved development plan and land division for all units with common walls.

TYPES OF PROPERTIES ARE INCLUDED WITHIN THE T3 TRANSECT DESIGNATION?

AMERICAN GOTHIC PLAYHOUSE

RESIDENTIAL/COMMERICIAL ROOFING APPLICATION Date / / BUILDING PERMIT APPLICATION

A Guide for the Homeowner/Builder

SUPER SHED. Indoor shelter for your outdoor tools.

GENERAL BUILDING PERMIT INFORMATION FOR: RESIDENTIAL ALTERATIONS & ADDITIONS

Building Construction. Lightweight construction. Conventional Construction

Detached accessory structures that contain no conditioned floor area are exempt.

NON-RESIDENTIAL BUILDING PERMIT PROCEDURES

City of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA ,

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

Waterleaf ARB Application

Structural Design for Residential Construction

CITY OF SONOMA TOOLKIT DOCUMENT #1a

BEAMCHEK EXAMPLES. RIDGE BEAM SIMPLE SPAN EXAMPLE No. 1 ACTUAL MATERIALS, LOADS AND CODE REQUIREMENTS MAY VARY. THIS IS AN ILLUSTRATION ONLY.

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

Residential Plan Routing Information

Bureau Veritas Contact Information

Formwork for Concrete

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

CHAPTER 5 - "R1" SINGLE-FAMILY RESIDENTIAL DISTRICT

Residential Accessory Buildings

Building Information Packet

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

March 14, Installation of Bay, Bow and Garden Windows

CITY OF YORBA LINDA P.O. BOX CALIFORNIA

Maximum Floor Area and Maximum Development Area

St. Louis County Department of Public Works Division of Code Enforcement. When is a Building Permit required for Residential Projects?

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Superform Products Ltd.

Division Yard, Lot, and Space Regulations.

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

An Applicant s Guide to Residential Building Permits

Washoe County PLAN SUBMITTAL

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Estimated Cost of Repair

A Homeowner s Guide to Building Permits

How to secure your property after a disaster

Footing and Temporary Power Inspection

Best Barns USA Assembly Book

PARK COUNTY BUILDING PERMIT GUIDE PO Box 517 Fairplay, CO Fax: Inspections:

You will be notified by letter after the ACC committee has made a decision. They have at least 30 days to review and respond to your application.

RESIDENTIAL PHOTOVOLTAIC SUBMITTAL REQUIREMENTS

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED ( )

Site Development Information Worksheet for single family residential development

Zoning Department DECK PERMITS. Checklist

QUEEN ANNE'S COUNTY BUILDING CODE TECHNICAL ASSISTANCE BULLETIN

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Section 13 Urban Residential Zones

TOWNSHIP OF TOMS RIVER ZONING OFFICE DECK CONSTRUCTION

Solar Planning and Zoning Implementation Guide

Notice of Temporary Rules January 26, Certification Changes. Purpose of the rules: Citation: Effect of the rules: Contact:

BUILDING PERMIT SPECIFICATIONS

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

BUILDING SAFETY UNIT

Prestige Home Inspection LLC

Transcription:

CITY OF MANTECA COMMUNITY DEVELOPMENT DEPARTMENT 1001 West Center Street Manteca, CA 95337 FAX (209) 923-8955 Building Safety Division (209) 456-8550 Community Development/Planning Division (209) 456-8500 Attached/Detached Patio Cover/Carport NOTE: Check with your homeowners association and architectural review committee for Conditions, Covenants & Restrictions (CC&R s). The City of Manteca has no regulatory authority to enforce or notify permit applicants of CC&R requirements, nor deny permits for non-compliance. SUBMITTAL REQUIREMENTS FOR COVERED PATIOS Refer to the drawings and information in this handout for help in preparing your submittal. Submit two (2) sets of complete plans, plus one (1) extra copy of the site plan. 1. SITE PLAN (see page 3) shall show: a. Lot dimensions and easements b. Existing structures and the proposed patio structure(s) and their dimensions, including square feet of each. c. Distance between the proposed patio and property lines d. Distance between the proposed patio and existing structures on the property 2. ARCHITECTURAL, STRUCTURAL and DETAIL SHEETS (see pages 6-7) shall show: a. Foundation plan, scaled b. Framing plan, scaled, shall show size of headers (beams), posts, post spacing, roof rafter size and spacing, attachments to walls, roof sheathing, type of roofing, and roof pitch or slope. c. Elevation, scaled, of view that can be observed from the street frontage, if applicable. Building/Public/Handouts/Patios/Patio Cover Handout.pub Page 1 Last updated: 2/9/2016

SETBACK and LOT COVERAGE REQUIREMENTS This overview is provided for reference only. Prior to building any structure or making an addition or modification to any existing structure, check with the Planning Division (209.456.8500) regarding minimum required distances from property lines and other structures. Check with the Public Works Division (209.456.8400) regarding the locations of any easements. 1. The maximum area of a lot that may be covered by roof structures (house, patio, garage, carport, sheds, etc.) (60) percent in the R-1 and R-2 Zoning District. 2. An attached/detached covered patio (including lattice patios) cannot be located closer than (5) five feet to a side or rear line unless one-hour fire protected then it can be (3) three feet inclusive of roof covering (overhang). The patio may not occupy more than (30) thirty percent of the required rear yard (See sample calculations on Page 4). A minimum of (10) ten feet (inclusive of roof covering) from street side lot line is required. (Contact the Planning Division of the Community Development Department for property line setbacks. The edge of the sidewalk is NOT the property line. The property line is normally 2 feet in back of the sidewalk) 3. A detached covered patio (e.g. gazebo) shall not be located closer than ten (10) feet to the main building (may extend up to five (5) feet, inclusive of roof covering, provided it has 1-hour fire wall rating). Building/Public/Handouts/Patios/Patio Cover Handout.pub Page 2 Last updated: 2/9/2016

SAMPLE SITE PLAN-CARPORT 10' SSJID EASEMENT EXISTING RESIDENCE PROPOSED CARPORT Proposed Carport: SF Existing Building Area: SF Total Building Area: SF Lot Area: SF Lot Coverage: % 10' PUBLIC UTILITY EASEMENT STREET NAME 1) Show lot dimensions and total square footage of all covered areas (Residence, garage, carport, covered patio, and any accessory structures). 2) Check with the Planning Division for building setback requirements. 3) Check with Public Works for location of any utility easements. Building/Public/Handouts/Patios/Patio Cover Handout.pub Page 3 Last updated: 2/9/2016

(70-0 ) (35-0 ) 5 MIN (3 MIN IF FIRE RATED) PROPOSED PATIO 5 MIN (3 MIN IF FIRE RATED) EXISTING RESIDENCE Proposed Patio: SF Existing Building Area: SF Total Building Area: SF Lot Area: SF Lot Coverage: % SAMPLE CALCULATION FOR ACTUAL REAR YARD 35 X 70 = 2450 SQFT ACTUAL REAR YARD THEREFORE, MAX ALLOWED SQFT (MAX 30%) 0.30 X 2,450 = 735 SQFT 10' PUBLIC UTILITY EASEMENT STREET NAME 1) Show lot dimensions and total square footage of all covered areas. 2) Check with the Planning Division for building setback requirements. 3) Check with Public Works for location of any utility easements. 4) The width and depth of the proposed patio cover are measured from eave-to-eave. (Planning) SAMPLE SITE PLAN-PATIO COVERS Building/Public/Handouts/Patios/Patio Cover Handout.pub Page 4 Last updated: 2/9/2016

SAMPLE FLOOR PLAN MEASUREMENT RAFTER SPAN (DEPTH) (SEE TABLE A) OVERHANG BEAM SPAN MEASUREMENT BEAM SPAN POST CENTERLINE TO CENTERLINE (TABLE B) EXISTING STRUCTURE PROPOSED PATIO BEAM SPAN OVERHANG Building/Public/Handouts/Patios/Patio Cover Handout.pub Page 5 Last updated: 2/9/2016

TABLE A: Allowable Spans for Rafters (Live Load = 20 psf, Dead Load = 10 psf) SIZE* SPACING SPAN 2" x 4" 2" x 6" 2" x 8" 2" x 10" 2" x 12" 12" 10 10 16" 9 10 24" 8 0 12" 16 7" 16" 14' 4" 24" 11' 9" 12" 21 0" 16" 18' 2" 24" 14' 10" 12" 25' 8" 16" 22' 3" 24" 18' 2" 12" Span exceeds 26' in length 16" 25' 9" 24" 21' 0" TABLE B: Allowable Spans for Beams (Live Load = 20psf, Dead Load = 10 psf) SIZE* 10' DEPTH 15' DEPTH 20' DEPTH (2) 2 x 6 8 11 7 6 6 7 (2) 2 x 8 11 4 9 6 8 4 (2) 2 x 10 13 10 11 7 10 2 (2) 2 x 12 16 0 13 5 11 10 4 x 4 6 7 5 6 4 10 4" x 6" 9 8" 8 1 7 1 4" x 8" 12 8" 10 8 9 5 4" x 10" 15 7 13 1 11 6 4" x 12" 18 2 15 3 13 5 4" x 14" 20 4 17 1 15 1 *Douglas Fir Larch #2 Building/Public/Handouts/Patios/Patio Cover Handout.pub Page 6 Last updated: 2/9/2016

REQUIRED DETAILS See Page 7 for Specifications " x " RAFTER (See Table A on Pg. 5) 7 ROOF PITCH " x " BEAM (See Table B on Pg. 5) MINIMUM 6' 8" 7 7 ROOF COVERING SPECIFICATIONS 1. The minimum roof pitch for asphalt shingles is 4:12; however, asphalt shingles may be installed at a pitch between 2:12 to less than 4:12 if two layers of Type 15 felt applied shingle-fashion are used and the shingles are self-sealing (2013 CBC Sect. 1507.2.2). 2. The minimum roof pitch for 24" wood shakes is 4:12 with a 10" exposure (2013 CBC Sect. 1507.9.2 AND Table 1507.9.8) 3. Plywood or particle board must be CC exterior or better and rated for the span being used. Nailing shall be a minimum of 8d at 6" O.C. on the edges and 12" O.C. on the field. 4. For roof pitches below 2:12, a low-sloped roofing system approved by the Building Official shall be used. 5. The details on this sheet are not meant to be used for concrete tile roof coverings. Building/Public/Handouts/Patios/Patio Cover Handout.pub Page 7 Last updated: 2/9/2016

ROOF COVERING: (SEE NOTES ON PAGE 6) SOLID BLOCKING EXISTING WALL EXISTING ROOF NEW ROOF COVERING 2" x " RAFTER at " O/C EXISTING ROOF SOLID BLOCKING EXISTING WALL NEW ROOF COVERING 2" x " RAFTER WITH APPROVED HANGER at " O/C 2" x LEDGER WITH 1/2" X 3" LAG BOLTS at 16" O/C FLASHING 2" x LEDGER WITH 1/2" X 5-1/2 LAG BOLTS INTO STUDS NEW ROOF COVERING 2" x " RAFTER WITH APPROVED HANGER at " O/C DETAIL A NOTE: CONNECTION TO FASCIA NOT ALLOWED WITHOUT ENGINEERING. MINIMUM 4" x 4" POST MINIMUM 3-1/2" CONCRETE SLAB APPROVED POST BASE THAT HOLDS POST 1" ABOVE THE CONCRETE (SIMPSON PBS44A OR EQUAL) 8 WIDTH DEPTH CONTINUOUS FOOTING MAX SUPPORTED ROOF AREA 12" WIDE x 12" DEEP UP TO 110 SQFT 12" WIDE x 18" DEEP UP TO 160 SQFT 18" WIDE x 18" DEEP UP TO 240 SQFT DETAIL B ISOLATED FOOTING MAX SUPPORTED ROOF AREA 12" SQ 12" 12" SQUARE X 12 DEEP - UP TO 50 SQFT 18" SQUARE X 12 DEEP - UP TO 110 SQFT 24" SQUARE X 12 DEEP - UP TO 200 SQFT 30" SQUARE X 12 DEEP - UP TO 310 SQFT DETAIL C Building/Public/Handouts/Patios/Patio Cover Handout.pub Page 8 Last updated: 2/9/2016