Digital-output relative humidity & temperature sensor/module DHT22 (DHT22 also named as AM2302)

Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy

DHT11 Humidity & Temperature Sensor D-Robotics UK (

T0118 T2118 T3118. Instruction Manual

Small 7-key User-definable Remote Control User s Guide

HM1500LF Relative Humidity Module

Calibration Management Software by CyberMetrics (480)

Temp. & humidity Transmitter Instructions

Microcontroller to Sensor Interfacing Techniques

SHT1x / SHT7x Humidity & Temperature Sensor

DS1621 Digital Thermometer and Thermostat

HP03 BAROMETER MODULE Version: 1.1

Wireless Temperature

Duct Humidity Transmitter

DS Wire Digital Thermometer and Thermostat

NC-12 Modbus Application

Green House Monitoring and Controlling Using Android Mobile Application

NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

DISCONTINUED. AtlasScientific. as of 10/21/13. E.C. Circuit. Biology Technology. Features

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Online Infrared Flue Gas Analyzer Gasboard 3000

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Features. Applications. Transmitter. Receiver. General Description MINIATURE MODULE. QM MODULATION OPTIMAL RANGE 1000m

HIH-4000 Series Humidity Sensors

LOW POWER SPREAD SPECTRUM OSCILLATOR

HTM2500LF Temperature and Relative Humidity Module

ICS379. Quad PLL with VCXO Quick Turn Clock. Description. Features. Block Diagram

TSic 101/106/201/206/301/306/506 Rapid Response, Low-Cost Temperature Sensor IC with Analog or digital Output Voltage

Fingerprint Based Biometric Attendance System

Product Datasheet P MHz RF Powerharvester Receiver

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

HDMM01 V1.0. Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES. Signal Path X

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DRS-6/1 Doppler Radar Sensor

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

GREISINGER electronic GmbH

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

DS1621 Digital Thermometer and Thermostat

USB-500/600 Series Low-Cost Data Loggers and Accessories

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

DS 600. A contact free flux gate based current measurement sensor 600A rms

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

Repeater Mil-Std-1553B Datasheet

MMC314xMR. Ultra Small 3-axis Magnetic Sensor, With I 2 C Interface. Signal Path X. Signal Path Y. Signal Path Z FEATURES

Road Vehicles - Diagnostic Systems

Temperature & Humidity SMS Alert Controller

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

FM Radio Transmitter & Receiver Modules

Electronic Pressure Switch EDS 300

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

SMS GSM Alarm Messenger

Signal Manager Installation and Operation Manual

SEMICONDUCTOR TECHNICAL DATA

Touchscreen Driver Installation. Introduction Specification Installation - for Windows 95/98 - for Windows NT - for Windows 2000/XP - for DOS

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

DALLAS DS1233 Econo Reset. BOTTOM VIEW TO-92 PACKAGE See Mech. Drawings Section on Website

USB-500/600 Series Low-Cost Data Loggers and Accessories

Model: DC-A2IO Advanced HVAC Controller

EZIO-4THIE * External CJC Sensor** (National LM19)

MANUAL TR-110 TR-110

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS (LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : DEC.01,1999 TOTAL PAGE : 7 APPROVED BY:

How To Use A Sound Card With A Subsonic Sound Card

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

USB-500 Series Low-Cost Data Loggers and Accessories

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Temperature Humidity Meter

1. Description. 2. Feature. 3. PIN Configuration

PCS0100en Persy Control Services B.V. Netherlands

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Kit 27. 1W TDA7052 POWER AMPLIFIER

Relative and absolute pressure switch type 529

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Manual Ranging MultiMeter

INTEGRATED CIRCUITS DATA SHEET. TDA W BTL mono audio amplifier. Product specification File under Integrated Circuits, IC01

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Electronic Control Devices The European Product Catalogue 2007

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

TLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009

EM3242. Angle Sensor IC [EM3242]

WS2811. Signal line 256 Gray level 3 channal Constant current LED drive IC. Feature. Applications. General description

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

If there is any doubt about the results, measurement shall be made within the following limits : Ambient temperature 25±3 Relative humidity 40%~70%

Tire pressure monitoring

Specification of 5 Wire Analog Touch Panel

DFN type package. Fully calibrated. Fast response time

DS1307ZN. 64 x 8 Serial Real-Time Clock

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

FM TRANSMITTER & RECEIVER HYBRID MODULES. FM-RTFQ SERIES FM-RRFQ SERIES. Transmitter. Receiver. Applications

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Transcription:

Digital-output relative humidity & temperature sensor/module AM2303 1. Feature & Application: Capacitive-type humidity and temperature module/sensor * Full range temperature compensated * Relative humidity and temperature measurement * Calibrated digital signal *Outstanding long-term stability *Extra components not needed * Long transmission distance * Low power consumption *4 pins packaged and fully interchangeable 2. Description: AM2303 output calibrated digital signal. It utilizes exclusive digital-signal-collecting-technique and humidity sensing technology, assuring its reliability and stability.its sensing elements is connected with 8-bit single-chip computer. Every sensor of this model is temperature compensated and calibrated in accurate calibration chamber and the calibration-coefficient is saved in type of programme in OTP memory, when the sensor is detecting, it will cite coefficient from memory. Small size & low consumption & long transmission distance(20m) enable AM2303 to be suited in all kinds of harsh application occasions. Single-row packaged with four pins, making the connection very convenient. 3. Technical Specification: Model AM2303 Power supply 3.3-6V DC Output signal digital signal via single-bus Sensing element Polymer humidity capacitor & DS18B20 for detecting temperature Measuring range humidity 0-100%RH; temperature -40~125Celsius - 1 -

Accuracy humidity +-2%RH(Max +-5%RH); temperature +-0.2Celsius Resolution or sensitivity humidity 0.1%RH; temperature 0.1Celsius Repeatability humidity +-1%RH; temperature +-0.2Celsius Humidity hysteresis +-0.3%RH Long-term Stability +-0.5%RH/year Sensing period Average: 2s Interchangeability fully interchangeable 4. Dimensions: (unit----mm) Pin sequence number: 1 2 3 4 (from left to right direction). Pin Function 1 VDD----power supply 2 DATA--signal 3 NULL 4 GND 5. Operating specifications: (1) Power and Pins Power's voltage should be 3.3-6V DC. When power is supplied to sensor, don't send any instruction to the sensor within one second to pass unstable status. One capacitor valued 100nF can be added between VDD and GND for wave filtering. (2) Communication and signal Single-bus data is used for communication between MCU and AM2303, it costs 5mS for single time communication. - 2 -

Data is comprised of integral and decimal part, the following is the formula for data. AM2303 send out higher data bit firstly! DATA=8 bit integral RH data+8 bit decimal RH data+8 bit integral T data+8 bit decimal T data+8 bit checksum If the data transmission is right, check-sum should be the last 8 bit of "8 bit integral RH data+8 bit decimal RH data+8 bit integral T data+8 bit decimal T data". When MCU send start signal, AM2303 change from low-power-consumption-mode to running-mode. When MCU finishs sending the start signal, AM2303 will send response signal of 40-bit data that reflect the relative humidity and temperature information to MCU. Without start signal from MCU, AM2303 will not give response signal to MCU. One start signal for one time's response data that reflect the relative humidity and temperature information from AM2303. AM2303 will change to low-power-consumption-mode when data collecting finish if it don't receive start signal from MCU again. 1) Check bellow picture for overall communication process: Host computer send out start signal. Sensor send out Data transmission finished, and RL pull up bus's voltage response signal. Output data: 1bit"0" for next transmission Pull up and wait Host's signal Sensor's signal Output data: 1bit "1" response from sensor Sensor pull down Pull up voltage and get bus's voltage ready for sensor's output. Single-bus output - 3 -

2) Step 1: MCU send out start signal to AM2303 Data-bus's free status is high voltage level. When communication between MCU and AM2303 begin, program of MCU will transform data-bus's voltage level from high to low level and this process must beyond at least 18ms to ensure AM2303 could detect MCU's signal, then MCU will wait 20-40us for AM2303's response. Check bellow picture for step 1: Host computer send start signal - and keep this signal at least 500us Sensor send out response signal - and keep this signal 80us Host pull up voltage -and wait sensor's response Sesnor pull up bus's voltage Signal from host Start data transmission Signal from sensor Single-bus signal Step 2: AM2303 send response signal to MCU When AM2303 detect the start signal, AM2303 will send out low-voltage-level signal and this signal last 80us as response signal, then program of AM2303 transform data-bus's voltage level from low to high level and last 80us for AM2303's preparation to send data. Check bellow picture for step 2: - 4 -

Start transmit 1bit data Start transmit next bit data 26-28us voltage-length means data "0" Host signal Sesnor's signal Single-bus signal Step 3: AM2303 send data to MCU When AM2303 is sending data to MCU, every bit's transmission begin with low-voltage-level that last 50us, the following high-voltage-level signal's length decide the bit is "1" or "0". Check bellow picture for step 3: - 5 -

70us voltage-length means 1bit data "1" Start transmit 1bit data Start transmit next bit data Host signal Sensor's signal Single-bus signal If signal from AM2303 is always high-voltage-level, it means AM2303 is not working properly, please check the electrical connection status. 6. Electrical Characteristics: Item Condition Min Typical Max Unit Power supply DC 3.3 5 5.5 V Current supply Measuring 1.3 1.5 2.1 ma Average 0.5 0.8 1.1 ma Collecting Second 1.7 2 Second period *Collecting period should be : >1.7 second. 7. Attentions of application: (1) Operating and storage conditions We don't recommend the applying RH-range beyond the range stated in this specification. The DHT11 sensor - 6 -

can recover after working in non-normal operating condition to calibrated status, but will accelerate sensors' aging. (2) Attentions to chemical materials Vapor from chemical materials may interfere AM2303's sensitive-elements and debase AM2303's sensitivity. (3) Disposal when (1) & (2) happens Step one: Keep the AM2303 sensor at condition of Temperature 50~60Celsius, humidity <10%RH for 2 hours; Step two: After step one, keep the AM2303 sensor at condition of Temperature 20~30Celsius, humidity >70%RH for 5 hours. (4) Attention to temperature's affection Relative humidity strongly depend on temperature, that is why we use temperature compensation technology to ensure accurate measurement of RH. But it's still be much better to keep the sensor at same temperature when sensing. AM2303 should be mounted at the place as far as possible from parts that may cause change to temperature. (5) Attentions to light Long time exposure to strong light and ultraviolet may debase AM2303's performance. (6) Attentions to connection wires The connection wires' quality will effect communication's quality and distance, high quality shielding-wire is recommended. (7) Other attentions * Welding temperature should be bellow 260Celsius. * Avoid using the sensor under dew condition. * Don't use this product in safety or emergency stop devices or any other occasion that failure of AM2303 may cause personal injury. - 7 -