PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY



Similar documents
HM-W536 Install Guide

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

INSTALLATION & SERVICE MANUAL. Display Panel

Tone Hammer 500. Owners Manual. Manual Version 1.0

Advantium 2 Plus Alarm

MCR1900 Media Converter 19-Slot Chassis

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

LOXONE 12 Channel Amplifier

12-Volt 10-Amp Regulated Power Supply

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

LIEBERT VNSA Installation Sheet

Doorbell Intercom Security System

The power module is Feature Number 8800-F2-901.

Tips for connecting 24-volt power

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

HP UPS R1500 Generation 3

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

About the HotWire Slot Standalone Shelf

Water Leak Detection System

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Streaming Potential System (SPT1000, SPD1000)

Voltage Loss Formula s

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

Installation and Operation Guide PD4600 Series Converter Replacement

16/32 Channel 1U Rack Mount CCTV Power Supply

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

MCA Series Multi-Channel Amplifiers. Operation Manual

Operating Instructions. UL325 Compliant Non-monitored

OPERATING INSTRUCTIONS

IP DSLAM IDL Quick Installation Guide

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Operating Instructions

Refer installation of power supplies to qualified service personnel.

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

Battery Power Inverters

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI /12/01

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Industrial Ringdown/Autodialer Telephone SCR Series

Model 1756 Test Lead Kit

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

Single Station Remote Alarm

ST Series POWER SUPPLIES USER INSTRUCTIONS

VLT Series 300 Watt True Sine Wave Inverter

Intersection Preassembled 19-inch Rack

OWNER'S MANUAL. AtlasSound.com PA601 COMMERCIAL AMPLIFIER. PA601 Commercial Amplifier. Power. Master

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Model PS-4001 Power Supply User Instructions

For Models #6-5001, #6-7501, # & #10-12K1

Self Monitoring Power Supply (BPSM)

EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

AXIS PS12 Outdoor Power Supply. Installation Guide

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Operating Instructions

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

INSTRUCTION MANUAL MODEL PCD-88

What is a multimeter?

ETZGAR CONVEYOR COMPANY Controls Section v12.05

7 FUNCTION DIGITAL MULTIMETER

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSIDE TELEPHONE WIRING FOR Business

Generator Transfer Switch Model # HTS15-AUTO

INSTALLATION INSTRUCTIONS

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Z-TRAUQ INC. Tel.: (450) Fax: (450)


Installation and Operation Guide for PD4100 Series Power Control Centers

How To Size A Stenner Pump

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

ECM-30 30A AC Power Module Spike Suppressor

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Achat 115MA full-range speaker. user manual

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

FW-X240 AUTO TRANSFORMER Installation Manual

User s Manual AURORA 1.2K/2.2K

User Manual for CH-PFC76810

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

AMERBRITE UNDERWATER WHITE LED POOL LAMP

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Installation and Operation Guide for PD4000 Series Power Control Center

DVI DA2 and DVI DA 4 User Guide

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Transcription:

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06

CONGRATULATIONS You have purchased a practical source for CCTV power. The Juice Goose PS4-24 is a wall mountable 24 VAC power distribution module that features a pre-attached power cord for easy installation. FEATURES SUMMARY PS4 features include: WALL MOUNT NEMA 1 ENCLOSURE POWERING UP TO 4 CAMERAS 3.75 AMPS @ 24VAC INDIVIDUAL FUSES FOR EACH POWER CONNECTION 7 FOOT POWER CORD SAFETY PRECAUTIONS The PS4 is designed to operate with 120VAC, 60 Hz input. Operation with 220 or 240 volts will damage the unit and possibly cause personal injury. CAUTIONS 1. The PS4 should always be grounded. Defeating the unit s grounding capability could create a hazard. 2. There are no user serviceable parts inside the PS4. Do not attempt service yourself. Contact Juice Goose as directed in this manual if service is required. 3. Do not expose the PS4 to moisture. Avoid severe physical impacts to the unit. DISCLAIMER Juice Goose shall under no circumstances be held responsible for any loss, damage or injury resulting from the use of the PS4 in a manner inconsistent with any of the procedures outlined in this document. The user is responsible for determining whether this product is appropriate for the intended application. Juice Goose is not responsible for any indirect, secondary or ancillary loss or damage, including personal injury, loss of or damage to property or loss of income resulting from the operation or failure of this unit. FEATURES DETAIL FRONT PANEL Four screws hold the front cover in place. This cover should be removed only for installation and fuse replacement. MAIN ENCLOSURE This metal enclosure houses the power transformer as well as the power supply circuit board.

CIRCUIT BOARD Camera Power Terminals The PS4 has two sets of 4 terminals, labeled Fused Power Outputs and Common Power Outputs. Each terminal pair, designated 1 4 should be attached only to a single camera. Power Input Terminals The high voltage transformer leads are connected to the power cord. If desired, a qualified electrician may disconnect this power cord and hard wire these leads directly to a 120 VAC power source. (See installation instructions for additional information.) Camera Power Fuses These fuses provide excess current protection for each low voltage connection. These fuses should be rated at 2 amps (48 watt load). Main Power Fuse This fuse should be rated at 4 amps (96 watt load). On / Off Switch Allows power output to be turned off for installation and fuse replacement. Power Indicator LED Lights to show the power supply is operational. POWER CORD The PS4 connects to utility power with a grounded 7 foot long power cord with a NEMA 5-15P plug, secured with a strain relief. This power cord may be removed if hardwiring the power supply is desired. This task should only be performed by a certified electrician. INSTALLATION 1. Make sure the PS4 is unplugged when installing it and making connections with cameras. Turn the power switch to Off. 2. If the PS4 is to be hardwired by a qualified electrician, he may remove the power cord and prepare the transformer input wires for attachment to utility power. 3. Remove desired knock out to route camera power leads into the enclosure. Mount the PS4 in the desired location using the four screw holes on the mounting bracket. 4. Connect cameras to the screw terminals on the PS4 circuit board. Both leads from a single camera should be connected to the same terminal bank (e.g. both to position 1, 2, 3 ). 5. Plug the PS4 power cord into a grounded 120 VAC utility receptacle (unless hardwired). Power will be supplied to connected equipment as soon as the power switch is turned on. The power indicator LED will light when power is present. 6. Replace front panel and secure with the 4 screws provided. 7. Fuse Replacement Always turn off power to the PS4 before replacing fuses. Always use the same amperage value as the fuse being replaced.

DIMENSIONS (INCHES) 10.0 x 8.0 x 4.0 WEIGHT (LBS) 10 POWER INPUT POWER OUTLETS CURRENT CAPACITY 120 VAC, 60Hz 2 BANKS OF 4 POSITION BARRIER STRIPS.75 @ 120 VAC 3.75 AMPS @ 24 VAC POWER CORD CURRENT OVERLOAD PROTECTION 7 FOOT, 18/3 SJT OR GREATER 4 AMP MASTER CIRCUIT CHASSIS DESIGN CHASSIS FINISH NEMA 1 METAL ENCLOSURE POWDER COAT ENAMEL TAN SPECIFICATIONS TROUBLE SHOOTING Before trouble shooting this power supply disconnect the power. If power is not reaching some cameras check the fuse(s) and camera power line connection(s). If power is reaching no cameras check that the LED on the PS4 circuit board is lit. Check the master circuit fuse. Do not exceed the specified current limits of the PS4. Check the main source of power to the PS4. REPAIR Should your PS4 need service contact Juice Goose for assistance and authorization to return the unit. PLEASE NOTE: a return authorization number is required in order for the service personnel to correctly and promptly identify, repair and return your unit. You may obtain a Return Authorization Number by calling: 713-772-1404 or sending email to info@juicegoose.com.

POWER FACTS AND CALCULATIONS TERMINOLOGY & RELATIONSHIPS Amperage is a measure of current flow. (Similar to capacity or volume of flow.) A power supply with greater amperage capacity than the current demand of the equipment being powered is OK. = Watts / Volts (100 Watts at 24 Volts = 4.17 ) Current () = Voltage / Resistance (Ohms) Impedance in an AC circuit is very similar to resistance in a DC circuit and is often used interchangeably. Resistance is a force that opposes current flow in a circuit. Voltage is a measure of potential electromotive force (similar to pressure). A power supply with higher voltage than recommended for a camera is NOT OK. Voltage Drop/100 Feet =.2 x Amperage x 1.26 (AWG-10) Watts = Volts x (24 Volts with 4.17 = 100 Watts)

AWG 0.5 VOLTAGE DROP This chart illustrates voltage drop per 100 feet of paired wire as a function of wire gauge and load current. By matching load current () across the top of the chart with wire gauge (AWG) down the left side of the chart, one can determine voltage drop per 100 feet of paired wire run. Note: at 24 volts, 2 amps = 48 watts. For that size load the voltage drop for 100 feet of 18AWG would be 2.64 volts. 1.0 2.0 4.0 10.0 10.10.20.40.80 2.00 12.16.32.64 1.25 3.2 14.25.50 1.0 2.0 5.0 16.40.80 1.60 3.20 8.00 18.64 1.32 2.64 5.28 12.80 20 1.01 2.02 4.04 8.08 20.20 22 1.60 3.20 6.40 12.80 32.00 MINIMUM WIRE GAUGE FOR MAXIMUM 3.2 VOLT DROP This table lists the required minimum wire size necessary to complete a paired wire run of the stated length and experience no more than a 3.2 volt drop between the power supply and the camera or other powered device. In the example above, should the cable run have been 200 feet rather than 100, with a 2 amp load, in order to not have a drop in excess of 3.2 volts, the wire size would need to be at least 16 AWG. An alternative solution would be to power the load with an original voltage of 28 VAC. 0.5 1.0 2.0 4.0 10.0 Distance (Feet) 25 22 22 22 20 18 50 22 22 20 18 14 100 22 20 18 16 12 200 22 18 16 12-300 20 16 14 10-400 18 16 12 10-500 16 14 12 - -

JUICE GOOSE CCTV POWER SUPPLIES PART NUMBER DESCRIPTION RACK MOUNTED RPS16-RX-24-12 RPS16-RX-24-24 RPS16-RX-24-0 RPS16-RX-12-12 RPS12-RX-12-0 RPS16-0-24-12 RPS16-0-24-24 RPS16-0-24-0 RPS16-0-12-12 RPS16-0-12-0 AC PROTECTION, 24VAC + 12 VDC, 16 CAMERAS AC PROTECTION, 24VAC + 24VAC, 16 CAMERAS AC PROTECTION, 24VAC, 8 CAMERAS AC PROTECTION, 12VDC + 12 VDC, 16 CAMERAS AC PROTECTION, 12 VDC, 8 CAMERAS 24VAC + 12 VDC, 16 CAMERAS 24VAC + 24VAC, 16 CAMERAS 24VAC, 8 CAMERAS 12VDC + 12 VDC, 16 CAMERAS 12 VDC, 8 CAMERAS WALL MOUNTED PS1-24 PS1-24-4 PS4-24 PS4-24-4 PS4-24-300 PS4-24-300-4 PS8-24 PS8-24-4 PS8-24-300 PS8-24-300-4 24VAC, 90W, 1 CAMERA. 24VAC, 90W, 1 CAMERA, NEMA 4 ENCLOSURE 24VAC, 90W, 4 CAMERAS, INCL. POWER CORD 24VAC, 90W, 4 CAMERAS, NEMA 4 ENCLOSURE 24 or 28VAC, 300W, 4 CAMERAS, INCL. POWER CORD 24 or 28 VAC, 300W, 4 CAMERAS, NEMA 4 ENCL. 24VAC, 90W, 8 CAMERAS, INCL. POWER CORD 24VAC, 90W, 8 CAMERAS, NEMA 4 ENCLOSURE 24 or 28VAC, 300W, 8 CAMERAS, INCL. POWER CORD 24 or 28VAC, 300W, 8 CAMERAS, NEMA 4 ENCL. For additional Juice Goose products log on to our web site www.juicegoose.com or call 713.772.1404