Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB



Similar documents
Inductive sensor NI10-M18-Y1X-H1141

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Explosion proof enclosures

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Instruction Manual. T3111 T3111L T3111P T3111Ex

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Tina 2A/B Adaptor unit

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Terminal Boxes Series 8146

Series 8146/5-V37 and Series 8150/5-V37

Antenna Splitter ASA 1. Instruction manual

Design of intrinsically safe systems

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Original instructions Tina 3A/Aps Adaptor unit

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Instructions for Safe Use

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

CAPACITIVE LEVEL METERS CLM 36

Instruction Manual Differential Pressure Transmitter

CompactLogix Power Supplies Specifications

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Operating Instructions

2.12. page Products for Explosion hazardous Environment

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

SEISMIC VELOCITY TRANSDUCER T1-40

Compact pressure switch Flameproof enclosure Ex d Model PCA

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Series 510 Submersible Level Transmitters

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

8146/5 Series Breaker Panelboards

Operating Instructions

Relative pressure transmitter type 520

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

1756 ControlLogix Chassis Specifications

1788 Linking Device Specifications

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

PART 1 - INTRODUCTION...

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Operating Instructions

Sanitary and CIP Toroidal Sensor

Inductive slot sensor

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

62 Max/62 Max + Infrared Thermometer

Fluxi 2000/TZ Turbine Gas Meter

Technical data sheet TDS0070

Toroidal Conductivity Sensor

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Super Slider ADJUSTABLE FROM Model #HD26229

A99B Series Temperature Sensors

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

T U R B I N E G A S M E T E R

UM-X Field display for continous level sensors

SECTION 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND DEVICES

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

Ground Resistance Clamp-On Tester

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

DS 600. A contact free flux gate based current measurement sensor 600A rms

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Getting started with

CB Zone Conventional Control Panel

Terminal Box. Specifications TNCN

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Lockout Specification BW Clip Maintenance-free single gas detector

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Sip/Puff Switch User Guide

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Humidity Sensor. Model HU-224/225

Solenoid Valve Island Type 3965

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

TC-9102 Series Surface Mount Temperature Controllers

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Advantium 2 Plus Alarm

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Redundancy Module QUINT-DIODE/40

COMBIMASS. Technical Data COMBIMASS eco-bio +

Transcription:

Air Sensor SAC Ex Manual AQ Elteknik AB ATEX

Air Sensor SAC Ex ATEX Certified model Manual version 2.0 Oct 2010 AQ Elteknik AB 2

Table of contents 1. Manufacturer information... 4 Manufacture Declaration of Conformity... 4 Limited Warranty... 4 Returning the Air Sensor... 4 Warning... 4 Manufacturer information... 4 2. Introduction... 5 Air Sensor... 5 Ultrasound Controller D72 / DP72... 5 3. Functional Description... 5 Principle of Bubble Detection... 5 Sensitivity... 5 4. Installing the Air Sensor... 6 Installing the Air Sensor... 6 Cable... 6 Vertical or Horizontal Installation... 6 5. Connecting the Air Sensor... 6 Connecting the Air Sensor Ex using barriers... 6 Choosing a barrier... 6 Ex-barriershields... 7 Connecting Air Sensor FCS via barriers to Ultrasound Controller D72 or DP72... 8 6. Settings, Calibration and Troubleshooting... 9 7. Ex description... 9 Label information written on Air Sensor Ex... 10 8. Technical specifications... 11 Air Sensor SAC Ex dimensions... 11 Cable for Air Sensor... 11 AQ Elteknik AB Air Sensor Manual SAC Ex 3

1. Manufacturer information AQ Elteknik AB operates a policy of on-going development and reserves the right to make changes and improvements to any of the products described in this users guide without prior notice. Any changes on the products will take place only after consulting the certifying body to ensure that the changes will not effect the Ex safety. Under no circumstances shall AQ Elteknik be held responsible for any loss or indirect damage howsoever caused. The contents of this document are provided as it is. AQ Elteknik AB reserves the right to revise this document or withdraw it at any time without prior notice. Manufacture Declaration of Conformity Manufacturer: AQ Elteknik AB Sweden declares, that the product: Air Sensor marked with CE-label conforms with the following standards: EN 61000-6-2:2001, EN 61000-6-4:2001, EN55011 (Group 1, Class B). The Air Sensor is RoHS Compliant, directive 2002/95/EC. Air Sensor marked with conforms to WEEE. Limited Warranty AQ Elteknik AB warrants to the original end user that the Air Sensor is free from any defects in materials or workmanship for a period of one year from the date of purchase. During the warranty period, should the Air Sensor have indications of failure due to faulty workmanship or materials, AQ Elteknik AB will replace it with no charge. This warranty shall not apply if the Air Sensor is modified, misused or subjected to abnormal working conditions. Replacement as provided under this warranty is the only remedy of the purchaser. The purchaser pays freight to AQ Elteknik AB. AQ Elteknik AB shall in no event be held liable for indirect or consequential damages of any kind or character to the purchaser. Returning the Air Sensor If the Air Sensor is to be discarded it shall be sent back to AQ Elteknik AB for safe disposal. If the Air Sensor shall undergo a warranty commission it shall be sent back to AQ Elteknik AB. Before sending the Air Sensor to AQ Elteknik AB it must be clean and without any harmful contaminations. A certificate shall be attached with the Air Sensor that confirms the cleaning and shows following information: Who has cleaned the Air Sensor (company if other than sender) Who has checked and confirmed that the Air Sensor is clean (company and person) Who is sending back the Air Sensor (company) See Manufacturer Information for return address. Warning The Air Sensor is intended to be used with the Ultrasound Controller manufactured by AQ Elteknik AB. AQ Elteknik AB takes no responsibility for any possible damage that could happen if the Air Sensor is connected to any equipment not manufactured by AQ Elteknik AB. Manufacturer information Manufacturer: AQ Elteknik AB address: Alsikegatan 4 phone: +46 (0)18-18 34 30 SE-753 23 Uppsala fax: +46 (0)18-10 50 04 Sweden web: www.aqelteknik.com e-mail: info@aqelteknik.se 4

2. Introduction Air Sensor Liquid flowing through the Air Sensor is monitored with ultrasound and the presence of gas or particles is detected by the connected Ultrasound Controller. The Air Sensor is reliable and easy to use. It is turned from one piece and the inside is completely smooth with low Ra-value Ultrasound Controller D72 / DP72 Ultrasound Controller D72 or DP72 is recommended for use with the Air Sensors. It mounts on a DIN-rail and can be connected to two Air Sensors. 3. Functional Description Principle of Bubble Detection Bubbles in the liquid flowing through the Air Sensor are monitored by the use of ultrasound. Inside the Air Sensor two low intensity beams of ultrasound are transmitted across the liquid-path in directions perpendicular to the liquid flow. If a bubble moves into one of the ultrasound-beams the ultrasound will be partially deflected and the intensity of the ultrasound decreases. The controller constantly measures the intensity of the ultrasound and if it becomes lower than a threshold it detects a bubble. Dense particles in the liquid also deflect the ultrasound and can therefore be detected. To achieve very low sensitivity for bubbles a different technique is used, measuring the damping effect liquid has on vibrations in the air sensor wall. Sensitivity The sensitivity for bubbles can be set to high, medium, low, very low and very very low. (How to set it, see the users guide for the D72 / DP72 ultrasound controller.) With sensitivity set to high a single bubble of approximately 2mm diameter or larger can be detected passing trough the Air Sensor. With sensitivity set to medium a single bubble of approximately 3mm diameter or larger can be detected. With sensitivity set to low a single bubble of approximately 10mm diameter can be detected. Low sensitivity is achieved in the Air Sensor by requiring both detectors to detect bubbles at the same time. Many small bubbles together will be detected as if they were a single big bubble. Even tiny (microscopic) bubbles can be detected if there are very many of them. When using very low sensitivity the Air Sensor should preferably be installed with vertical liquid flow since otherwise lingering liquid drops inside the Air Sensor can be detected as liquid. Very low sensitivity does not work well with Air Sensors with diameter <14 mm. AQ Elteknik AB Air Sensor Manual SAC Ex 5

4. Installing the Air Sensor Installing the Air Sensor One or two Air Sensors can be connected to one Ultrasound Controller D72 or DP72. The Air Sensor is designed to be installed with mini-tc/tc and it is important to install the sensor correctly by connecting the triclamp properly to avoid leakage. When installing the Air Sensor it is also necessary to take into consideration external heating and cooling sources for remaining the operating temperature range. The Air Sensor is designed to be used in normal atmospheric pressure (0.8 bar 1.1 bar) and also normal oxygen content 21%. The Air Sensor should be installed in accordance with national regulations. A person with the required knowledge should perform installation. Cable The cable from the Air Sensor connects to the barriers hazardous side. The maximum cable length is 40m. The cable-shield is important because it prevents external noise from entering. If the cable is extended, use same or similar cable type (4 conductor with common shield). NOTE! The unshielded part of the cables should be max 40mm. Vertical or Horizontal Installation We recommend if possible installing the Air Sensor with vertical liquid flow. The bubbles will then be drawn to the center where bubbles are easier detected. If the Air Sensor however is installed horizontally, we recommend the Air Sensors to be turned in such a way that the connector is on top. Bubbles at the top of the Air Sensor will then be easier detected. 5. Connecting the Air Sensor Connecting the Air Sensor Ex using barriers The Ultrasound Controller D72 or DP72 is not ex-certified and intrinsically safe barriers must be used to connect the Air Sensor Ex. The diagram below shows how to connect two Air Sensors SAC via two barriers. It is important to install the barriers and the sensors according to EN 60079-14 and to summarize the voltage and current according to appendix B. One zener barrier is needed for each Air Sensor. In the diagrams, the cable type between D72 / DP72 and the barriers is the same type as between the barriers and the Air Sensors. If another cable type is used it must be shielded. Unshielded parts of the cable should not be unnecessary long. Choosing a barrier The barrier must be chosen according to EN 60079-14, but there are also measurement considerations for choosing the barrier: 1. The barrier must use resistive current limitation. 2. The barrier must be made for unbiased AC current relative ground. 3. The barrier voltage should be as high as can be allowed. (minimum ±8V AC) 4. The barrier resistance should be as low as can be allowed. (maximum 110Ω) 5. The barrier must attenuate 2MHz as little as possible. The barrier capacitance to ground should be as low as possible. Recommended barrier: Pepperl+Fuchs Z960. 6

Ex-barriershields Shielding aluminum plates must be placed outside each group of barriers belonging to each Ultrasound Controller D72 / DP72. The zener barriers are not shielded, so if there are no shielding aluminum plates, noise can be transferred between barriers belonging to different D72 / DP72. Also unshielded parts of the cables should be short to prevent noise being transferred between different D72 / DP72. Shielding aluminum plate must be ordered separately, item no: Ex-barriershield. The Ex-barriershield snaps on to the DIN-rail next to the intrinsically safe zener barriers, see picture. AQ Elteknik AB Air Sensor Manual SAC Ex 7

Connecting Air Sensor SAC via barriers to Ultrasound Controller D72 or DP72 8

6. Settings, Calibration and Troubleshooting See D72 or DP72 manual. 7. Ex description The Air Sensor is made to be used in Apparatus-group IIB and Equipment-group 1/2G. The inside of the conduit of the sensor is designed to be exposed to zone 0 and the remaining parts to zone 1. The sensor is transmitting ultrasound into zone 0. Notice that Ultrasound Controller D72 is not Ex certified and barriers must be used to connect the Air Sensors. The intrinsically safe circuit inside the sensor is isolated from earth. Common regulations for installation and maintenance of explosive protected electrical equipment shall be observed. (EN 60079-14 and EN 60079-17 in European countries connected to CENELEC). A person with the required knowledge should perform installation. Special conditions for use: 1) The enclosure of the Air sensor must be connected to earth via the mounting in the conduit system. 2) Any external sources of heating must be considered at installation to not exceed the maximum ambient temperature +60 C for the sensors. AQ Elteknik AB Air Sensor Manual SAC Ex 9

Label information written on Air Sensor Ex Air Sensor Made in Sweden Type see Technical specifications Inner diameter see Technical Specifications Ex Class II 1/2 G Ex ib IIB T4 SP No. SP08ATEX3637X Transport temp. Tamb: -20 to +60 C Max input voltage Ui: 13,0 V Max current input Ii: 0,70 A Max power input Pi: 1,20 W Inner capacitance Ci: 50 nf Inner inductance Li: 50 µh 10

8. Technical specifications Operating temperature range 0 C to 60 C Maximum temperature range* -20 C to 60 C Maximum pressure SAC: 1Mpa / 10 bar g at operating temperature range Protection class IP67 Finish in pipe (Ra-value) <0,375 µm / <15 micro inch *Proper indication of bubbles is not guaranteed at temperatures outside operating temperature range SAC Ex Air Sensor SAC Ex dimensions Model number Inner diameter (mm) Outer diameter (mm) Tri Clamp diameter (mm) Material SAC10-25 Ex 10 51 25 Stainless steel 316L SAC16-25 Ex 16 51 25 Stainless steel 316L SAC16-50 Ex 16 64 50 Stainless steel 316L SAC22-50 Ex 22 64 50 Stainless steel 316L SAC35-50 Ex 35 64 50 Stainless steel 316L SAC46-64 Ex 46 76 64 Stainless steel 316L SAC60-77 Ex 60 102 77,5 Stainless steel 316L Cable for Air Sensor Cable order-number Color Length WB Cable 7m Blue 7m WB Cable 20m Blue 20m WB Cable 40m Blue 40m WG Cable 7m Grey 7m WG Cable 20m Grey 20m WG Cable 40m Grey 40m AQ Elteknik AB Air Sensor Manual SAC Ex 11