F1000 VITREOUS CHINA URINAL BENEFITS FEATURES



Similar documents
No-Flush Urinals PRESERVING GLOBAL WATER

Georgia State Amendments to the International Plumbing Code

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

FUTRUS WALL-MOUNT VANITY SINK SOLUTIONS WITH DUPONT CORIAN

Residential Plumbing BCN 1058

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

CHAPTER 11 STORM DRAINAGE

An Assessment of. Long-Term Performance of Non-Water (Waterfree) Urinals. in Relation to Drain Line Buildup. Falcon Waterfree Technologies and

Saferand easierinstallation

MORE THAN A LINEAR DRAIN. THE SOLUTION FOR SHOWERS & WET AREAS.

Carriers, Fixtures & Piping

CHAPTER 11 STORM DRAINAGE

Top 10+ Mistakes of DWV plumbing design

Effective Date: March Rev. 5/29/2015- Void After: March Product: Ceramic Plumbing Fixtures File No. 3360

DRAIN, WASTE AND VENT PLUMBING

Teacher Assessment Blueprint. Plumbing. Test Code: 5175 / Version: 01. Copyright 2010 NOCTI. All Rights Reserved.

Introduction. Kitchens

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

Amendments to the 2012 International Plumbing Code

SECTION COMMERCIAL PLUMBING FIXTURES

INSTALLATION MANUAL. Glass Vessel Sink. I toll free: I Kraus USA Inc.

604 Water Closets and Toilet Compartments

Installation Guide. Product Code: CNECHO. T: F: Page 1 of 9. ITEM: Echo Footspa from Continuum Footspas

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Jay R. Smith Mfg. Co.

Plumbing Instructions

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE

UNIFORM PLUMBING CODE and UNIFORM PLUMBING CODE STANDARDS Edition

15430 SAFETY SHOWERS AND EYEWASHES

How To Build A Backwater Valve

Install a bathroom anywhere without any major construction

ADA Design Guide Washrooms & Showers

PUBLIC RESTROOMS, DESIGN INTENT

Toilet Plumbing. Here is a selection of different types of W.Cs and urinals. Can you match the pictures to the names below?

Making Your Home Ready For Solar Water Heating

Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.

EMERGENCY PLUMBING FIXTURES

:2009 HELLENIC CHNICAL SPECIFICATION ежглеяис тгс йубеямгсеыс (теувос еутеяо) Sanitary ware, common ICS: 93.

Backflow Bulletin #1

Chapter 7 Plumbing Connections

GENERAL PLUMBING REQUIREMENTS

ATS Revit Family Creation Standards July 23 rd, 2012 Plumbing Fixtures: Faucets Version 1.0

3. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.

ACO Water Management: Civils + Infrastructure

We ve got you covered.

PREVENTATIVE MEASURES TO BE TAKEN BY THE OWNER FOR BASEMENT FLOODING OF A RESIDENCE

INSTALLATION INSTRUCTIONS MK-8704

At the end of today s seminar you should be better. Recognize the causes of Sewer Lateral backup. Identify techniques to protect your home from

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Commercial Gas Water Heaters

How To Make A Spill Containment System

GENERAL PLUMBING REQUIREMENTS

Does Wall Township require an inspection by the building department on resale of a home?

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

INTERNATIONAL RESIDENTIAL PLUMBING CODE

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Select Radiators Installation Guide

How To Calculate Fixture Counts For A Building

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

Green Plumbing and Mechanical Code Supplement

2010 Residential Water Heater Replacement Check List

foundation designed to keep water out of the basement.

Effective Date: October 2015 Void After: October Product: Water Closets with Dual Flush Feature File No. 5319

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

How To Build A Basement House

Section 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC

PLUMBING ROUGH IN INSPECTION

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

UNIFORM PLUMBING CODE Edition

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

Flood Risk Considerations

The Town of Lakeshore Basement Flooding Information to Residents

INSTALLATION INSTRUCTIONS BL-8704

Base Cabinet with Self-storing Folding Doors and Floor

PERMITS REQUIRED & PERMIT EXEMPTIONS

WASTE STORAGE AND COLLECTION GUIDANCE FOR NEW DEVELOPMENTS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Hommage 2 PIECE WATER CLOSET BOWL MODEL TANK MODEL 7721 U1 SEAT MODEL

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01

Featuring fast rotor exchanges with AUTO-LOCK

Clinical Solutions.

Accessible Showers and ADA Showers

How To Retaining Wall Guide

EcoSoft Water Softener. General Installation Guide

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

This attractive cover system has been designed to complement the Pipe Cover and Skirting Cover product ranges.

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl.

Domestic Hot Water Systems and Plumbing Products

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Septic System Owner s Manual

Budget Basins Modular Spill Platform Spill Containment Pallets Spill Containment Platforms

2006 IPC INTERNATIONAL PLUMBING CODE AMENDMENTS PLANNING & DEVELOPMENT SERVICES DEPARTMENT

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

IBC Tote Containment Sumps

NoteBox NoteBox with room for 16 tablets

Transcription:

F1000 create more hygienic, odor-free restrooms. Our patented three part system, including vitreous china bowl, sloped housing and cartridge, eliminates the need for water, conserving up to an average of 40,000 gallons (150,000 liters) or more of water per urinal each year. The Falcon F1000 Waterfree urinal is constructed of vitreous china and is a wall hung, wall outlet unit. Its larger footprint is ideal for most retrofits. Our most popular design in North America, this waterless urinal provides clean lines for both a pleasing appearance and convenient cleaning. The F1000 meets ANSI/ ASME A112.19.19-2006 for vitreous china non-water urinals and is CSA approved. It also meets ADA guidelines and ANSI A117.1 for accessible and usable buildings and facilities and complies with International Plumbing Code, National Standard Plumbing Code and Uniform Plumbing Code requirements. Ideal for retrofits Wide bowl

F2000 create more hygienic, odor-free restrooms. Our patented three part system, including vitreous china bowl, sloped housing and cartridge, eliminates the need for water, conserving up to an average of 40,000 gallons (150,000 liters) or more of water per urinal each year. The unique and contemporary design of the F2000 has made it a popular choice in many upscale locations where its narrower and smaller profile adds a touch of flair to any restroom. This waterless urinal is constructed of vitreous china and is a wall hung, wall outlet unit. The F2000 meets ANSI/ASME A112.19.19-2006 for vitreous china non-water urinals and is CSA approved. It also meets ADA guidelines and ANSI A117.1 for accessible and usable buildings and facilities and complies with International Plumbing Code, National Standard Plumbing Code and Uniform Plumbing Code requirements. Stylish, modern appearance Unique shape

F4000/CLEMATIS create more hygienic, odor-free restrooms. Our patented three part system, including vitreous china bowl, sloped housing and cartridge, eliminates the need for water, conserving up to an average of 40,000 gallons (150,000 liters) or more of water per urinal each year. The Falcon F-4000 waterfree urinal is constructed of vitreous china and is a wall hung, wall outlet unit. Its smaller size is ideal for installations with space limitations. The stylish design of this waterless urinal combines an attractive appearance with functionality and efficiency. The F-4000 meets ANSI/ASME A112.19.19-2006 for vitreous china non-water urinals and is CSA approved. It also complies with ADA guidelines and ANSI A117.1 for accessible and usable buildings and facilities and with the International Plumbing Code, National Standard Plumbing Code and Uniform Plumbing Code requirements. Ideal for limited space Small size

F5000/FREESIA create more hygienic, odor-free restrooms. Our patented three part system, including vitreous china bowl, sloped housing and cartridge, eliminates the need for water, conserving up to an average of 40,000 gallons (150,000 liters) or more of water per urinal each year. The Falcon F5000/Freesia Waterfree urinal is constructed of vitreous china and is a wall hung, wall outlet unit. It is the smallest Falcon Waterfree urinal, and ideal for installations with space limitations. The stylish design of the Freesia combines an attractive appearance with functionality and efficiency. The F5000/Freesia meets ANSI/ASME A112.19.19-2006 for vitreous china nonwater urinals and is CSA approved. It also complies with ADA guidelines and ANSI A117.1 for accessible and usable buildings and facilities and with the International Plumbing Code, National Standard Plumbing Code and Uniform Plumbing Code requirements. Ideal for limited space Small size

FLAX create more hygienic, odor-free restrooms. Our patented three part system, including vitreous china bowl, sloped housing and cartridge, eliminates the need for water, conserving up to an average of 40,000 gallons (150,000 liters) or more of water per urinal each year. The Falcon Flax W aterfree urinal is constructed of vitreous china and is a wall hung, wall outlet unit. It is one of our smallest waterless urinals, ideal for installations with space limitations. The stylish design of the Flax combines an attractive appearance with functionality and efficiency. The Flax meets ANSI/ASME A112.19.19-2006 for vitreous china non-water urinals and is CSA approved. It also complies with ADA guidelines and ANSI A117.1 for accessible and usable buildings and facilities and with the International Plumbing Code, National Standard Plumbing Code and Uniform Plumbing Code requirements. Ideal for limited space Small size

LAVA/F7000 sewer costs, lower maintenance and repair bills, and create more hygienic, odor-free restrooms. Our patented three part system, including vitreous china bowl, sloped housing and cartridge, eliminates the need for water, conserving up to an average of 40,000 gallons (150,000 liters) or more of water per urinal each year. The Lava/F7000 Waterfree urinal is made of vitreous china and is a wall hung, wall outlet unit. This waterless urinal features a patent-pending, splash-free design, contemporary styling and a mid-size wall footprint making it ideal for retrofits and new construction. The Lava/F7000 includes a special area for messaging, which can be used to describe environmental accomplishments for the facility or for generating advertising space. The Lava/F-7000 meets ANSI/ ASME A112.19.19-2006 for vitreous china non-water urinals and is CSA approved. It also complies with ADA guidelines and ANSI A117.1 for accessible and usable buildings and facilities and with the International Plumbing Code, National Standard Plumbing Code and Uniform Plumbing Code requirements. Ideal for retrofit and new construction Messaging/advertising space

FALCON WATERFREE URINALS When it comes to urinals, nothing compares to the technological innovation and unsurpassed performance of Falcon Waterfree urinals. Falcon Waterfree urinals offer numerous benefits that will make your job easier and help fulfill your strategic facility plan. Falcon Waterfree urinals reduce water and create more hygienic, odor-free restrooms. A patented cartridge eliminates the need for water, conserving up to 40,000 gallons or more per unit each year. Pipe-in-pipe technology assures excellent flow even when installed in most older horizontal pipe nipples with flat slope. All maintenance costs, flooding and vandalism problems associated with flush valves are eliminated. Ideal for retrofit and new construction

INFORMATIONAL SPECIFICATIONS F1000 F2000 F4000 F5000 F7000 MATERIAL WIDTH 19 3/8" 492 mm 16 7/8" 429 mm 15 3/8" 391 mm 13" 330 mm 14 1/8" 359 mm HEIGHT 25 7/8" 657 mm 24 5/8" 625 mm 22 5/8" 575 mm 19 5/8" 498 mm 21 7/8" 556 mm DEPTH 14 3/8" 366 mm 14 5/8" 372 mm 14" 356 mm 14" 356 mm 14 5/8" 372 mm WEIGHT 63 lbs 28.6 kg 53 lbs 24.0 kg 35 lbs 15.8 kg 27 lbs 12.3 kg 44 lbs 20.0 kg DRAIN HEIGHT FROM FLOOR FOR 24" LIP HEIGHT 16 3/4" 425 mm 16 5/8" 422 mm 17" 432 mm 16 3/4" 425 mm 17" 432 mm LEED POINTS COMPLIANCE CERTIFICATIONS Meets ANSI/ASME A112.19.19-2006 for vitreous china non-water urinals. UPC/ IPC/NSPC Meets ADA guidelines and ANSI A117.1 for accessible and usable buildings and facilities. Check local codes. These dimensions are for informational purposes only. For specific rough-in dimensions and weights, please refer to specification sheets available at FalconWaterfree.com or contact us directly. WARNING Never install waterfree urinals on copper drain, waste and vent systems.