DSM155 Digital LED Light Meter User s Manual DSM155



Similar documents
USER GUIDE. LED Light Meter. Model LT45

Light Meter (Foot Candles)

Dual Laser InfraRed (IR) Thermometer with Color Alert

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer

High Temperature InfraRed Thermometer with Laser Pointer

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Hygro-Thermometer + InfraRed Thermometer Model RH101

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

ExStik TM ph Waterproof Meters

Ultrasonic Distance Meter. Operation Manual

Microwave Meter. Instruction Manual

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

TABLE OF CONTENTS 11.0 WARRANTY

EzFlex Combustible Gas Leak Detector Model EZ40

Temperature Humidity Meter

Precision Lightmeters Made in Germany

INSTRUCTION MANUAL DTH Fax: (503)

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Mini InfraRed Thermometer with Laser Pointer

Mold Alert... Operation Manual P0270

User's Guide Integrating Sound Level Datalogger Model

Dual Laser InfraRed (IR) Thermometer

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Optical Power Meter. Specification & User Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Model SRMD Setra Remote Monitoring Display

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

62 Max/62 Max + Infrared Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Owner s Manual

Advantium 2 Plus Alarm

Pocket Tach 99 (PT99) Non-Contact Tachometer

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Combustible Gas Leak Detector 720b

Infrared Viewers. Manual

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

12 Volt 30 Amp Digital Solar Charge Controller

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Instruction Manual Temp 4/5/6 Temperature Meter Series

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

Features: Mounting the Optic

Cross-beam scanning system to detect slim objects. 100 mm in

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

User Guide. HDMI Active Cable Extender. DVI-7370c

LED Lighting - Error Consideration for Illuminance Measurement

RGC-IR Remote Gas Calibrator for IR400

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

AutoRanging Digital MultiMeter

Temperature, Humidity & Dew Point Chart Recorder

Installation Instructions

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Wolverine Data PASS Portable Scanner User Manual V1.0

User's Guide. Pinless Moisture Meter. Model MO257

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

CO-220 Carbon Monoxide Meter

Thermistor Thermometer MODEL NO

4-Channel Thermometer / Datalogger

Wireless Indoor/ Outdoor Thermometer

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

SURFACE MOUNT LED LAMP STANDARD BRIGHT 0606

How To Use The Visifault Visual Fault Locator

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Leica DISTO TM D210 The original laser distance meter

Operating Manual FINGERSIM SET /5.11. for SECULIFE NIBP in Combination with SECULIFE OX1

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

CUSTOMER SERVICE CONTACTS

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Ground Resistance Clamp-On Tester

FIRERAY 2000 Installation Guide

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

INSTALLER S & OWNER S MANUAL

User's Guide. Digital Sound Level Meter. Model

323/324/325. Calibration Manual. Clamp Meter

Part # rev 1. American Diagnostic Corporation 55 Commerce Drive, Hauppauge, New York

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

0.28" Quadruple Digit Numeric Displays. Technical Data Sheet. Model No.: KW4-281XSB

LCD5500Z / PKP-LCD v3.x Installation Instructions

Professional Thermohygrometer

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Introduction. Electronic Message Centers (EMC s) ISA International Sign Association A Summary Report on EMC Brightness Levels

PK5500 v1.1 Installation Instructions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

FC6 FOOT CONTROLLER OWNER S MANUAL

Thermocouple Thermometer Models

i410/i1010 AC/DC Current Clamp

Intelli-Time Alarm Clock model 13027

OPERATION MANUAL INFRARED THERMOMETER

1.50mm Height 2220 Package Top View Full Color Chip LEDs Technical Data Sheet. Part No.: LL-R5050RGBC-001

Water Tank Level Monitor

SOUND LEVEL METER 94405

Transcription:

DSM155 Digital LED Light Meter User s Manual DSM155

CONTENTS TABLE OF CONTENTS......3 LIMITED WARRANTY AND LIMITATION OF LIABILITY......3 Out of Box....3 Accessories....3 Safety Information....3 Certification....5 INTRODUCTION......5 Overview....5 Figures and Components....5 Buttons and Components......5 Display Description......8 USING THE METER......9 About the Meter...9 Concepts of illuminance scales....10 Conversion of illuminance and light intensity......10 CONTENTS Basic Functions......11 Readings Hold......11 Auto and Manual Range......11 Maximum and Minimum Measurement...11 Source Selection Mode......11 Lux/FC Measurement......1 Light Intensity measurement mode...1 Relative and Peak Measurement....13 ZERO Calibration......13 Button Sound ON/OFF...14 Auto Power Off....14 SPECIFICATIONS......14 MAINTENANCE AND REPAIR.....15 Repair......15 Meter Calibration...15 Replacing Battery......15 Contact Dawson.....16 01 0

LIMITED WARRANTY AND LIMITATION OF LIABILITY This instrument from Dawson Tools Inc. will be free from defects in workmanship and material for three years from the date of original purchase. This warranty does not cover defects resulting from damage caused by the user such as drops, neglect, misuse, unauthorized alteration, usage outside of specified conditions, contamination, or improper repair/maintenance. To receive service on the instrument if it becomes necessary during the warranty period, contact your nearest Dawson authorized service center at (800) 898-6991 or visit www.dawsontools.com to obtain a return authorization (within the US only). A return authorization is necessary before returning any instrument to Dawson; no service will be provided without a return authorization. The user is responsible for properly packing the unit and charges such as shipping, freight and insurance charges. The extent of Dawson's liability is limited solely to the repair/replacement of the instrument. The above warranty in its entirety is inclusive and no other warranties, written or oral, are expressed or implied. Out of Box Check the meter and accessories thoroughly before using the meter. Contact your local distributor if the meter or any components are damaged or malfunction. Accessories 9V Battery x1 Case x1 User s Manual x1 Safety Information Warning TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, PRODUCT DAMAGE OR PERSONAL INJURY, PLEASE FOLLOW THE SAFETY INSTRUCTIONS DESCRIBED IN THE USER MANUAL. READ THE USER MANUALS BEFORE USING THE METER. Warning TO ENSURE SAFE OPERATION AND LIFE OF THE METER, DO NOT PLACE THE METER IN ANY ENVIRONMENT WITH HIGH PRESSURE, HIGH TEMPERATURE, DUST, EXPLOSIVE GAS OR VAPOR. Avoid shaking, dropping or any kind of impacts when using or transporting the meter. To avoid electric shock or personal injury, repairs or servicing not covered in this manual should be performed only by qualified personnel. Avoid direct exposure to sunlight to ensure extended life of the meter. Use only the batteries indicated in the Technical Spec. Avoid exposing batteries to humidity. Replace batteries as soon as the low battery indicator appears. Please keep the original packing for future shipping purposes (ex. Calibration) After opening the box, check for any damage during delivery. 03 04

Safety Symbols on the Meter Important safety information, please refer to the user manual Important Safety Information Repair or maintenance should be implemented by trained personnel. Certification The meter is compiled to EMC requirements. INTRODUCTION Overview The DSM155 is a high precision portable digital LED light meter. The meter features a bar graph display for easy measurement of illuminance and light intensity. With the ability to switch between standard lighting and various LED light sources, this meter is highly versatile and useful in many different situations. Figures and Components Buttons and Components 1. Light sensor protection cover. Light sensor 3. LCD display screen 4. Power and tone ON/OFF: Power on/off: Press the key to activate the device and hold for 1 second to turn it off. Button tone on/off: When power is on, press the key to turn on/off the button tone. 5. Max/Min Light source button 6. Lux/Foot candles/light intensity button 7. Data hold and Zero calibration button: Data hold: Press to enter/exit data hold mode. Zero calibration: Press for 1 second to perform zero calibration. 8. Relative value and peak value measurement button: Relative value measurement: Press to enter/exit relative value measurement mode. Peak value measurement: Hold for 1 second to enter/exit peak value measurement mode. 9. Manual range button: Press the button to select ranges, Hold for 1 second to return to auto range mode. 05 06

Front Panel 1 Display Description 1. Manual range mode. Auto range mode 3. Analog bar graph 4. Light source selection 5. Measurement display 6. Lux units 7. Intensity (CD) units 8. Foot candles (Fc) units 9. Meters/Feet units 10. Data hold mode 11. Low battery symbol 1. Peak measurement mode 13. Minimum measurement mode 14. Maximum measurement mode 15. Relative measurement mode 1 15 14 13 1 11 3 4 5 DSM155 8 9 3 4 5 10 9 8 7 6 6 7 LCD display interface 07 08

USING THE METER Warning TO ENSURE SAFE OPERATION AND LIFE OF THE METER, DO NOT PLACE THE METER IN ANY ENVIRONMENT WITH HIGH PRESSURE, HIGH TEMPERATURE, DUST, EXPLOSIVE GAS OR VAPOR. About the Meter The light sensor of this meter is designed to simulate the sensitive curve of light obtained through human eyes. The spectral coverage is between 30mm and 730mm. For best results, use the meter to measure light within this range. Measurement outside this range ex. infrared range may be inaccurate. The light sensor is calibrated by common electric incandescent lamps required by CIE under the color temperature of 854 K; reading may be different for the spectrum of other lamps. Light source should be facing light sensor directly. The optical detector should be exposed to the light source for minutes before making measurement. Influences such as shadows and other factors on the optical detector should be avoided. Concepts of illuminance scales A Lux is defined as the illuminance on a surface of one square meter when a uniform source of one candela is placed one meter away from the surface. A foot-candle (Fc) indicates the illuminance on a surface of one square foot, when a uniform source of one candela is placed one foot away from the surface. 1 Fc = 10.764 lux 1 lux = 0.0990 Fc Conversion for illuminance and light intensity E = I / r I = Exr Where, E --- Illuminance value (Unit: Lux) I --- Light intensity of the light source (Unit: cd) r --- Distance from the luminous surface of light source to the optical detector (Unit: m). During measurement, the minimum distance between the luminous surface of the light source and the light sensor should be greater than 15 times the diameter of the light sensor or light source ( choose the one with the larger diameter). 09 10

Basic Functions Press the power button to turn on the meter, the default setting is auto-range Lux measurement. The measured ambient light level is displayed. Face the light sensor to the light source. Readings Hold Press HOLD/ZERO button to hold the current reading. Press HOLD/ZERO button again to release the hold. Auto and Manual Range Press RAN to switch from auto range to manual range. MANU is displayed on the top left corner of the screen. Press RAN multiple times to choose the desired range. Hold RAN to switch back to auto range (AUTO is displayed) Maximum and Minimum Measurement Press MAX/MIN/LS to hold the maximum value on the display. Press MAX/MIN/LS again to switch to minimum. Press "MAX/MIN/LS" a third time to return to normal display. Source Selection Mode Hold the MAX/MIN/LS button for one second and the LS value will flash on the LCD display. The meter is now in source selection mode. Press MAX/MIN/LS or Lx/Fc/CD to change the light source (L0-L9); hold "Lx/Fc/CD" to accelerate the change. Press the RAN button and the value of the selected light source begins to flash. Press MAX/MIN/LS or Lx/Fc/CD to change the value, hold MAX/MIN/LS or Lx/Fc/CD to accelerate the change. Press RAN again to switch back to the previous step. Hold the MAX/MIN/LS button to save the light source setting and return to normal mode. Light source default values: L0-Standard lighting: 1.000 L1-LED daytime light: 0.990 L-LED red light: 0.516 L3-LED amber (yellow) light: 0.815 L4-LED green light: 1.16 L5-LED blue light: 1.475 L6-LED purple light: 1.148 L7--L9-default standard lighting: 1.000 Lux/FC Measurement To switch units between Lux and FC, press LX/FC. Default unit is Lux. Light Intensity measurement mode Hold the Lx/Fc/CD button and the display will switch to light intensity distance mode where you can adjust the distance from the light source. Press the RAN button to switch between meters and feet. Press the MAX/MIN/LS or Lx/Fc/CD button to adjust the distance value. Hold the Lx/Fc/CD button to save the distance and the LCD display will now show the measured light intensity measurement. Press the Lx/Fc/CD button to return to illuminance measurement. Light intensity is calculated based on the following formula: Light intensity (CD) = illuminance (Lx) x distance squared (m ) 11 1

Note: 1. Light intensity measurement mode range: distance between 0.01~30.47m or 0.01~99.99ft.. If a single light source is used, the light intensity of the source can be set to calculate and display the distance from the light to the sensor. Relative and Peak Measurement Difference between Peak and Max : Peak measures the instantaneous output of the light source at a higher sampling rate where Max displays the maximum value obtained (at a lower sampling rate). Press REL/PEAK to enter Relative measurement (REL) mode. When REL is pressed, the instantaneous measurement is set as reference level 0 and the value displayed is the difference between the current measurement and the reference level. Change range and units as desired. To enter PEAK mode, Hold REL/PEAK until PEAK shows up on the screen. Change range and units as desired. Press and hold REL/PEAK to return to normal mode. ZERO Calibration To calibrate the meter, cover the sensor with the sensor cover. Press and Hold HOLD/ZERO button until ADJ is displayed on the screen. Once ADJ disappears, calibration is done. NOTE: The meter can be calibrated while the sensor is exposed to light. This will serve as a relative measurement. Button Sound ON/OFF Press the power button to turn off button sound, press again to turn it back on. Auto Power Off The meter will turn off if not in used for more than 10 minutes. SPECIFICATIONS Analog bar display: 3½ digits, max reading of 1999, w/ Analog Bar Display Sampling rate: times/sec Measurement range: 0 to 00k Lux 0 to 0k FC 0 to 999k CD Measurement spectrum: 30~730nm wavelength (λ) Sensor: silicon photoelectric diode Power supply: 1 x 9V battery Battery life: ~00hrs Operating temperature: 10 F to 1 F (-10 ~+ 50 C) Max. Operating Humidity: 80% RH Storage temperature: 10 F to 1 F (- 10 ~+ 50 C ) Max Storage humidity: 80% RH Outside measurement: 7.5(L) x 3.5(W) x 1.67(H) (190 (L) 89(W) 4.5 (H) mm) Weight: about 7 oz. (00 g) including batteries Accuracy: ±3% (calibrated with incandescent lamps at 854K); ±6% other visible light sources. 13 14

MAINTENANCE AND REPAIR Repair Please follow these steps closely if the meter is not functioning properly: Check batteries; replace with new batteries if low battery indicator appears. Follow the user s manual to confirm all procedures. Before sending meter back for repair, include a description of the problems encountered. Remove batteries and pack meter well to avoid damage in delivery; Dawson does not cover damage due to delivery. Repair or service not covered in this manual should be performed only by the authorized service center or qualified personnel. Meter Calibration The meter should be calibrated once a year. A standard light source is required for calibration. Please contact Dawson for details. Replacing Battery Follow these steps to replace battery: Turn off the meter. Loosen the battery compartment screw, and remove the door from the case bottom. Remove the battery and replace with a new battery. Reattach the battery compartment to the case bottom and tighten the screw. Contact Dawson Dawson Tools, Inc. 114 S. Diamond Bar Blvd., #858 Diamond Bar, CA 91765 Phone: (310) 78-60 www.dawsontools.com 15 16 00-05-379