bts 80 f/emb/flb/bsr Floor spring system



Similar documents
How To Fit A T.V Door Closer

TS83. Easy action door closer

PHA 2000 PHB 3000 EXIT PAD

EM Hold-open magnets

Floor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open DORMA BTS80 EMB

Easy-action Door Closer DORMA TS 83

Floor-Concealed Door Closers DORMA BTS80

Cam-action door closer. DORMA TS 90 Impulse

SR Door co-ordinators

EMF/EMR. Holder/Release Devices with Integral Door Closers

ABLOY DC 240 DOOR CLOSER Heavy duty door closer

K17.12 Door closers K17. Doors

Narrow stile lock 1314

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

NEWSTAR BROCHURE. December 2007

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

Concealed Door Closers

Installation Instructions and Ordering Information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

EM Hold-open magnets

TS93 EMR T/PT/TDE. Surface applied door closer

Controlled Door Closing Devices and Systems

STANLEY DOOR CLOSERS D-4550/D-4551 D-4550 / D-4551 SERIES OOR CLOSERS

RTS88. Overhead Concealed Door Closer

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

SECTION 6. Glass Storefront Doors:

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Code of Practice for fire resisting metal doorsets

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

ED 100LE ED 250LE. Low energy swing door operators

Automatic Door Selection Guide

8900 EMR (WITH DETECTOR)

DIGITUS Network & Server Cabinets. UNIQUE Series

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Electromagnetic Locking

7200 series Electromechanical Closer/Holder

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

D-4990 PRECISION HARDWARE

ABLOY EL420, EL520 Europrofile motor locks

Cable Plug acc. to DIN EN , Form A

Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

K700 series. Door Closer. Door Closer. Samhwa Precision Co., Ltd./Korea ASSA ABLOY Group Company. The global leader in door opening solutions

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

FIREDEX Conventional Fire Panels

Assisted lift operated 2/2-way solenoid valves Type EV250B

Turbine Flow Sensor Series VTR

Mini USB and USB 2.0-IP67 Connector System

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

Sliding and Folding Door Fittings Sliding Door Accessories

Electromagnetic locks

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Door Closers. DC3000 Series

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Series 300 / 200. Mortice locks for timber doors

ISO/VDMA Actuators. Engineering GREAT Solutions

08. SEK IDC CONNECTORS

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

EXIT HARDWARE. Uniclass L CI/SfB (31.59) Xt7 VERSION: AUGUST-11. An ASSA ABLOY Group brand

Product Management - Glass ALEXA PRODUCT PRESENTATION. Region SAARC Nitin Lloyd, Product Management. Chennai, FY 2013 / 2014

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

Relevant British, European and International standards

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Equipment Information

GEZE PRICE LIST DOOR AND WINDOW TECHNOLOGY GEZE PRICE LIST DOOR AND WINDOW TECHNOLOGY BEWEGUNG MIT SYSTEM

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s

Specialty Closers. High-End Residential High-End Security Gate Solutions

Torque Transducers MEASURING ELECTRONIC

SOURIAU s discrete wire sealing

ARCHITECTURAL. FritsJurgens Pivot Door System Product Range Brochure

Integral Kit Instructions

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Encoder WDGI 58H.

ED 100, ED 250. Mounting instructions

CERTIFICATE OF APPROVAL No CF 388 ALLEGION (UK) LIMITED

best practice guide BS EN 1154 Controlled Door Closing Devices to in association with

Guide to Safety Edge Systems

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

19 NETbox SOHO Network Wall Mounting Cabinets FAMILY

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Digital inductive conductivity transmitter

Type 3353 Angle Seat Valve

RM/55401/M, Roundline cylinder Magnetic piston, double acting

White Paper IK code: Impact protection in line with the IEC standard. By Sven Schnautz


3/2- and 2/2-way cartridge valve type BVE

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Fixed ladders. Fixed ladders. Shaft ladders

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

BLADE S-MAX Cabinet for Blade Server

Transcription:

bts 80 f/emb/flb/bsr Floor spring system

/EMB/FLB/BSR Floor spring system Door closer system for single- and double-leaf doors The door closer system BTS 80 perform its function discreetly yet still meet exacting convenience and safety criteria and is suitable for doors up to 300 kg. The technique of floor spring is almost invisible placed in the ground. The BTS 80 system with its 3 model variants (Floor spring for fire and smoke check doors), (with electro-hydraulic hold open), LB (with freeswing function) and the wide range of accessories allows effective adaptability to various door desingn and -functions. In conjunction with the doorcoordinator BSR, a use at double-leaf doors is possible. 2 DORMA

/EMB/FLB/BSR Floor spring system CONTENTS BTS 80 F/EMB/FLB/BSR Features and functions 4 BSR Door co-ordinator 6 BTS 80 System 8 Range of equipment and optional accessories 9 Specification texts 10 DORMA 3

/EMB/FLB/BSR Floor spring system Wide range of functions, concealed assembly, assured quality DORMA floor springs offer the perfect combination between freedom of creation and greatest reliability by their concealed floor mounting, providing a multitude of functions at the same time. Just as the requirements of preventive fire protection, the desire for barrier-free usage convenience and specific functions, like electrohydraulic hold-open and free-swing, is fulfilled. Long-term engineering experience and a manufacture certified according to ISO 9001 give the certainty of an assured and high quality. Technical data Closing force Standard doors Closing force Fire and smoke check doors BTS 80 F BTS 80 EMB BTS 80 FLB up to 1100 mm EN 4 EN 4 EN 4 up to 1250 mm EN 5 EN 5 EN 5 up to 1400 mm EN 6 EN 6 EN 6 up to 1100 mm EN 4 EN 4 EN 4 up to 1250 mm EN 5 EN 5 EN 5 up to 1400 mm EN 6 EN 6 EN 6 Handed model LH (ISO 6) 3 3 3 3 3 3 Universal 3 3 Closing speed variable by valve adjustment 3 3 3 Latching action variable by valve adjustment 3 3 Backcheck, mechanical 3 3 Plus points For the trade Complete range for every application. Simple stock holding thanks to identical accessories being used throughout the DORMA BTS range. For the installer Easy to install. Interchangeable spindle inserts, available to suit site conditions. For doors up to 300 kg in weight. For the architect/specifier Concealed installation. Range of functions to suit all applications. Proven, robust unit for doors weighing up to 300 kg. All models tested and quality assured, and approved by the Institute for Building Technology, Berlin. For CERTIFIRE approvals see certificate no. 127 (, EMB). For the user Reliable and fail safe. Closing speed unaffected by changes in temperature. Easy door operation thanks to high mechanical efficiency. Delayed action Hold-open, electro-magnetic, Hold-open point selectable 3 between 75 and 180 Free swing 0 180 3 Weight in kg 7,1 7,7 7,7 Dimensions Length 341 341 341 in mm Overall depth 78 78 78 Height 60 60 60 Power input in W 2,3 2,3 Operating voltage in vdc ± 15%, residual ripple max. 30% 24 24 Rated for continuous duty 100 100 Door closer tested to EN 1154 3 3 3 Hold-open devices tested to EN 1155 3 3 marking for building products 3 3 3 3 Yes No Option 60 78 341 1 Closing speed adjustment valve 2 Latching speed adjustment valve (not available with the LB) 3 Plug connector with cable for EMB and FLB power supply 51 57 1 3 78 36 42 36 42 2 4 DORMA

/EMB/FLB/BSR Floor spring system Floor spring 1 3 1 2 1 Fully controlled closing with adjustable speed 2 Adjustable latching action 3 Mechanical backcheck Example shows LH (ISO 6) door; mirrored arrangement applies to door. can be used on fire and smoke check doors. The doors must be especially designed for the use with the floor spring (distance to door hinge pivot 36 mm). An additional approval of suitability in connection with the particular fire and smoke check door is required. For the use on legally approved fire door assemblies, the regulations of the respective notice of approval must be complied with. F Approval certification has been approved, and is subject to third-party verifi-cation, by the State Material Testing Agency (MPA), /Dortmund, Germany. CERTIFIRE approved for fire doors; Cert. no. 127 Floor spring with electromagnetic hold-open 4 3 1 2 1 Fully controlled closing with adjustable speed 2 Adjustable latching action 3 Mechanical backcheck 4 Hold-open range (fall back approx. 3 ) Example shows LH (ISO 6) door; mirrored arrangement applies to door. can be used on fire and smoke check doors. The doors must be especially designed for the use with the floor spring (distance to door hinge pivot 36 mm). An additional approval of suitability in connection with the particular fire and smoke check door is required. For the use on legally approved fire door assemblies, the regulations of the respective notice of approval must be complied with. F Approval certification has been approved by the Institute for Building Technology, Berlin, for use in combination with all common smoke detector systems. CERTIFIRE approved for fire doors; Cert. no. 127 LB Floor spring with free-swing feature (electro-hydraulically controlled spring detent) 1 2 1 Free-swing range 2 Fully controlled closing in the event of an alarm or interruption of the power supply Example shows LH (ISO 6) door; mirrored arrangement applies to door. LB can be used on fire and smoke check doors. The doors must be especially designed for the use with the floor spring (distance to door hinge pivot 36 mm). An additional approval of suitability in connection with the particular fire and smoke check door is required. For the use on legally approved fire door assemblies, the regulations of the respective notice of approval must be complied with. F Approval certification LB has been approved by the Institute for Building Technology, Berlin, for use in combination with all common smoke detector systems. CERTIFIRE approved for fire doors; Cert. no. 127 DORMA 5

1 2 Standfl gel DIN Rechts /EMB/FLB/BSR Floor spring system BSR Door co-ordinator The BSR door co-ordinator ensures that, in double doors, the active leaf always closes after the inactive leaf. In the case of doors with full emergency escape hardware, the inactive leaf must be equipped with a carry bar. F Approval certification BSR is approved in Germany for use in combination with double fire and smoke doors by the State Material Testing Authority, Dortmund. Further fire approvals exist or are pending in other countries. Additional approval certification of the relevant fire and smoke doors may be necessary. approx. 1000-2800 51-57 51-57 15 15 75 /EMB/FLB /EMB 75 341 341 78 36 78 36 200 200 Active leaf Inactive leaf BSR The door co-ordinator operates independently of the hydraulics of the floor springs and consists of two mechanisms, one for the active and one for the inactive leaf, which are inter-connected by a Bowden cable. BSR door co-ordinator is non-handed and is combined with /EMB/FLB floor springs. Active leaf Inactive leaf 6 DORMA

/EMB/FLB/BSR Floor spring system approx. approx. 170 o 180 o BSR EMB 1 With just one hold-open device for the inactive leaf, this door co-ordinator enables both door leafs to be held open. The inactive leaf can be held open at a point between approx. 75 and 180 (fall-back approx. 3 ), while the active leaf is held open by the door co-ordinator at any desired an Active leaf approx. 75 o Inactive leaf approx. approx. 180 o 180 o BSR EMB 2 With this door co-ordinator, the active leaf can be held open independently of the inactive leaf. The hold-open points of both leaves lie between approx. 75 and 180 (fall-back approx. 3 ). approx. 75 o Active leaf approx. 75 o Inactive leaf approx. approx. 180 o 180 o approx. 75 o Active leaf Inactive leaf BSR EMB 1 G With this door co-ordinator for special door designs incorporating, for example, fixed side panels, or a narrow inactive leaf in asymmetric double door sets, etc., the active leaf can be held open separately. The hold-open point lies between approx. 75 and 180 (fall-back approx. 3 ). LB BSR FLB 1 G This door co-ordinator with integral free-swing function for the active leaf can also be installed where the doors are to remain free-moving but must nevertheless close. Active leaf Inactive leaf DORMA 7

/EMB/FLB/BSR Floor spring system Application and Installation LH RH Double action door Single action door Application for LH (ISO 6) offset pivoted door Application for offset pivoted door BTS 80 BTS 80 35 105 105 35 35 35 79 79 58 58 358 358 1,5 1,5 Universal cover plate Adaptable to right or left hand single action applications by simply snapping off the appropriate pre-blanked corner sections. For double action doors, the corner sections remain in place. The universal cover plate is available in stainless steel or satin brass (material thickness 1.5 mm). BSR BSR 36 105 105 36 79 79 388 388 1,5 1,5 Cover plate BSR The cover plate in the version for LH- or RH-doors is available in stainless steel or satin brass (material thickness 1.5 mm). 58 58 Example shows LH (ISO 6) door; mirrored Example arrangement shows LH (ISO applies 6) door; to door. mirrored arrangement applies to door. 3 Ø 25 X 8 Spindles A range of interchangeable spindles is available to provide greater floor clearance if required (e.g. doors with thresholds, carpeted floors etc). Special spindles available on application: e.g. with flat face profile and 3 offset or square section; spindles for non-dorma-specific accessories are also available. Calculating the necessary length of spindle extension: Extension = X Floor clearance (normally 8 mm) Collar height of the extended spindle inserts = Spindle extension length + 3 mm (collar height of the standard spindle insert) DORMA 2300 sealing compound For filling cavities between the floor spring body and the cement box to protect against moisture penetration. Information about other accessories such as door straps and top centres can be found in the for DORMA BTS Floor Springs leaflet. 8 DORMA

/EMB/FLB/BSR Floor spring system Standard equipment and accessories Floor spring /EMB/FLB including cement box without spindle Spindles Sealing compound, 2300 normal Extended spindle inserts (extension in mm) 5 7,5 10 12,5 15 20 25 28 30 35 40 45 50 EN 4 LH (ISO 6) Universal EN 5 LH (ISO 6) Universal EN 6 LH (ISO 6) Universal EN 4 LH (ISO 6) Universal EN 5 LH (ISO 6) Universal EN 6 LH (ISO 6) Universal LB EN 4 LH (ISO 6) EN 5 LH (ISO 6) EN 6 LH (ISO 6) 80220101 80220201 80220001 80210101 80210201 80210001 80230101 80230201 80230001 82224101 82224201 82224001 82214101 82214201 82214001 82234101 82234201 82234001 82124101 82124201 82114101 82114201 82134101 82134201 Universal cover plate Stainless steel 46700000 Satin brass 46700100 45200401 45200402 45200403 45200404 45200419 45200405 45200406 45200407 45200414 45200408 45200409 45200410 45200411 45200412 45090086 Door co-ordinator BSR Floor spring Spindles Cover Plates LH (ISO 6) normal Extension in mm 5 25 Stainless steel 46700080 Satin brass 46700280 Variant 45700900 BTS 80 EMB BTS 80 FLB 45200470 45200471 45200477 Stainless steel 46700081 Satin brass 46700281 BSR 1 x 2 x BSR-EMB 1 1 x 1 x 1 x BSR-EMB 2 1 x 2 x BSR-EMB 1 G 1 x 1 x 1 x BSR-FLB 1 G 1 x 1 x 1 x 2 x 2 x 2 x 1 x LH 1 x RH Accessory DORMA 9

/EMB/FLB/BSR FLooR SpRIng SySTEM specification text CE mark, with fully hydraulic control of the closing action from 180, adjustable latching action and backcheck. Including cement box. Model Y LH (ISo 6) Y RH (ISo 5) Y Universal Y Universal cover plate DoRMA CE mark, with electro-hydraulic hold-open, to En 1155 and integrated pressure compensation for constant, adjustable, temperature-immune hold-open between door opening angles of approx. 75 and 180. With adjustable closing speed under full hydraulic control, adjustable latching action and backcheck. Including cement box. operating voltage: 24vDC power input: 2.3 W Approved by the german Institute for Building Technology, Berlin, for use in hold-open systems. Model Y LH (ISo 6) Y RH (ISo 5) Y Universal Y Universal cover plate DoRMA LB CE mark, with electro-hydraulic free-swing function to En 1155 between door opening angles of 0 and 180, closer function (non-powered) effective from 180, and with backcheck (non-powered). Including cement box. operating voltage: 24vDC power input: 2.3 W Approved by the german Institute for Building Technology, Berlin, for use in hold-open systems. Model Y LH (ISo 6) Y RH (ISo 5) Y Universal cover plate DoRMA LB BTS 80 BSR CE mark, with fully hydraulic control of the closing action from 180, adjustable latching action, backcheck and door coordination function conforming to En 1158, operating independently of the closer hydraulics, comprising an active leaf and an inactive leaf mechanism interconnected by a bowden cable. Including cement box, non-handed. Y Cover plates DoRMA BTS 80 BSR 10 DoRMA

/EMB/FLB/BSR FLooR SpRIng SySTEM BTS 80 BSR-EMB 1 CE mark, with electro-hydraulic hold-open to En 1155 at the inactive leaf and integrated pressure compensation for constant, adjustable, temperatureimmune hold-open between door opening angles of approx. 75 and 180. With adjustable closing speed under full hydraulic control, adjustable latching action, backcheck and door co-ordination function conforming to En 1158, operating independently of the closer hydraulics, comprising an active leaf and an inactive leaf mechanism interconnected by a bowden cable. Including cement box, non-handed. operating voltage: 24vDC power input: 2.3 W Approved by the german Institute for Building Technology, Berlin, for use in hold-open systems. Y Cover plates DoRMA BTS 80 BSR-EMB 1 BTS 80 BSR-EMB 2 CE mark, with electro-hydraulic hold-open to En 1155 at the inactive and active leaf and integrated pressure compensation for constant, adjustable, temperature-immune hold-open between door opening angles of approx. 75 and 180. With adjustable closing speed under full hydraulic control, adjustable latching action, backcheck and door co-ordination function conforming to En 1158, operating independently of the closer hydraulics, comprising an active leaf and an inactive leaf mechanism interconnected by a bowden cable. Including cement box, non-handed. operating voltage: 24vDC power input: 4.6 W Approved by the german Institute for Building Technology, Berlin, for use in hold-open systems. Y Cover plates DoRMA BTS 80 BSR-EMB 2 BTS 80 BSR-EMB 1G CE mark, with electro-hydraulic hold-open to En 1155 at the active leaf and integrated pressure compensation for constant, adjustable, temperatureimmune hold-open between door opening angles of approx. 75 and 180. With adjustable closing speed under full hydraulic control, adjustable latching action, backcheck and door coordination function conforming to En 1158, operating independently of the closer hydraulics, comprising an active leaf and an inactive leaf mechanism interconnected by a bowden cable. Including cement box, non-handed. operating voltage: 24vDC power input: 2.3 W Approved by the german Institute for Building Technology, Berlin, for use in hold-open systems. Y Cover plates DoRMA BTS 80 BSR-EMB 1g BTS 80 BSR-FLB 1G CE mark, with electro-hydraulic free-swing function at the active leaf between door opening angles of approx. 0 and 180, closer function (non-powered) effective from 180, with backcheck (non-powered) and door co-ordination function conforming to En 1158, operating independently of the closer hydraulics, comprising an active leaf and an inactive leaf mechanism interconnected by a bowden cable. Including cement box, non-handed. operating voltage: 24vDC power input: 2.3 W Approved by the german Institute for Building Technology, Berlin, for use in hold-open systems. Y Cover plates DoRMA BTS 80 BSR-FLB 1g DoRMA 11

DORMA GmbH + Co. KG DORMA Platz 1 58256 EnnEPEtAl GERMAny Phone +49 2333 793-0 Fax +49 2333 793-4950 www.dorma.com WN 050 924 51532, 12/12, -EMB-FLB, GB, x. DD, xx/12 Subject to change without notice