Topic : Aviation Fuel Quality Control Regulation, Code or Standard



Similar documents
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

OREGON FIRE CODE Interpretations and Technical Advisories

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Northern Region. Underground Storage Tank


APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

NFPA31FuelOilPiping 1 Revised

Figure 1 Plugged Dispenser Filter vs. new

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

Underground Storage Tanks

2010 Residential Water Heater Replacement Check List

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

FIVE YEAR CERTIFICATION REPORT

Morrison Bros. Co. General Product Specifications

Spill Containment Manholes

UST RULES CHANGES. Heather Peters, Environmental Specialist

The following definitions apply with regard to requirements specified in this document:

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Civil Engineering Sector Labour-Management Health and Safety Committee

DESIGN STANDARDS SECTION

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Standard Hydraulic Piping Flushing Procedure

Pressure Vessels (Air Compressors) and LPG Tanks

Aviation Drummed Product Guide

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

CHAPTER 11 AVIATION FACILITIES

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Petroleum Storage Tank Compliance 101

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Western Plant Health Association DOT MC 330 & 331 NH3 Cargo Tank Inspection Checklist Form

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

Installing a Probe. Typical Installation

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Trouble Shooting. Pump

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Element D Services Plumbing

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

The following definitions apply with regard to requirements specified in this document:

Model 1210C Battery Powered Pump Shown. Description

Fire Pump Plan Review March 2010

CHECKLIST FOR INSTALLING OR CONVERTING EQUIPMENT TO DISPENSE E15, E30 E85 AND OTHER BLENDS OF ETHANOL General Information:

T E C H N I C A L S P E C I F I C A T I O N. SUPER FUEL & LUB TRUCK Fuel tanker and lubrication truck (6x6)

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

MODEL G300 BRAKE BLEEDER

BLADDER SURGE CONTROL SYSTEM

Waste Oil Collection / Storage

Air Eliminators and Combination Air Eliminators Strainers

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

Six Monthly Servicing of Fire Extinguisher on Commercial Vessels.

CHAPTER 9 SAMPLERS AND SAMPLING PROCEDURES

Section 8 Storage Tanks & Equipment

BP WIND ENERGY POLICIES AND PROCEDURES

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General

Float and Thermostatic Traps Series H, C and X

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

DRAFT REVISED Musts For USTs DRAFT. Printed on Recycled Paper. Updated June 2015

Installation of Underground LP-Gas Systems

Heavy-Duty Lube and Fuel Truck Sales Tool

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

Spill Prevention, Control and Countermeasure (SPCC) Rule

PMMIC 2013 Inspection Findings. Brian Pottebaum Rounds & Associates/PMMIC

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Quik Lining Systems Heater Owners Guide

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

BERMAD Fire Protection

6.7L Diesel Fuel System Contamination Diagnosis and Service Procedure Job Aid (Revised March, 2012)

The Fuel Storage Tank Regulations 2009

123 Industrial Loop Road Paynesville, MN Phone:

Spare Parts Program. Parts, Consumables & Accessories superproductsllc.com

11101, & INSTALLATION INSTRUCTIONS

BERMAD Fire Protection

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Chapter 7 Hydraulic System Troubleshooting

Midwest Industrial Tanks

ROUGHNECK II Pumpless Drain

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Leak free means a system where no gasoline is leaked while the system is

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

TECHNICAL ADVISORY BULLETIN

Revised April (May) 2015

Waste Oil Handling, Spill Containment & Lighting

Installation Manual DIAPHRAGM WELL TANK

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

ENGINE COOLING SYSTEM

Transcription:

Facility: Topic : Aviation Fuel Quality Control Regulation, Code or, 2-1.2, 2-1.6, 2-1.7, 3 Description of Compliant or All quality control records are available for inspection? Measures in place to ensure that all only correct type of fuel is delivered via the over wing nozzle Fuel defueled from an aircraft should be returned to the original aircraft and will not be co-mingled with joint use fueling systems Transport truck Deliveries Fuel Quality Control Audit Checklist Work Area: Date:, 3, 3, 3, 3, 3, 3 Airport facility operator will receive a certification document from jet fuel supplier or shipping agent certifying that the product being delivered meet ASTM D1655 specifications Listed on the report will be: visual appearance in white bucket, Gravity corrected to 60degrees F, Distillation, Flash Point, Freezing Point, Water Separation (MSEP), Copper Strip Corrosion, Existent Gum. Documents must also include: destination, batch number, fuel grade or type; quantity being shipped Truck hoses inspected for deficiencies, pending failures and cleanliness Allow truck to sit for 10 minutes with tank internal valves open Receiver will conduct Visual Appearance White bucket test, API Gravity, corrected to 60 degrees F, FSII % Test (pre-mixed fuel) March 2011 Page 1 of 19

, 3, 2,2, 2 Description of Compliant or Sump Tank(s) in which product was received a minimum of 1 hour following receipt of fuel. Horizontal storage tanks must have the following equipment: Floating suction, inlet diffuser, gauge hatch with slotted tube, access man way (2 preferred), automated high liquid level devices, secondary containment, placard next to sump drain indicating volume of drain pipe. Slope of 1 in 20 to low point sump with drain, 3 Filters, 3, 3, 3 All filter vessels must be equipped with: provisions for elimination of air, direct reading differential pressure gauges with accuracy of +/- 2 psi, manual sump drains, upstream and downstream (Millipore) connections, including probes and dust caps or plugs, Placard indicating month and year of last filter change. Physically segregated systems are required where more than one grade of fuel is stored; connections for receiving and dispensing different grades of fuel must be physically incompatible. An emergency fuel shutoff system is required. Emergency shutoff valves and switches must be clearly marked in accordance with the requirements of NFPA 407 and the area around them free of obstructions. Fire extinguishers with inspection tags must be positioned in accordance with applicable safety requirements Minimum of 1 125 lb Wheeled 80 BC extinguisher for fixed fuel facility with an open hose discharge capacity greater than 200 gpm March 2011 Page 2 of 19

Description of Compliant or Loading hoses and couplings must meet the following standards: Grade 2, Type C, Latest edition Hoses shall be installed with 2 years fo the date of manufacture and have a maximum service life of 10 years from the DOM. Fuel unloading hoses shall be compatible with type of fuel being dispensed NO SMOKING signs and product identification signs must be prominently displayed. Fuel storage facilities must be properly identified and color coded in accordance with the standards of API/IP 1542 latest edition Metal underground tanks and piping must be catholically protected Refueling Truck Loading Station. A handheld dead man control device is required for all truck loading operations, All stations must be equipped with static bonding capability. Bottom-loading nozzles and couplers must be equipped with 60 mesh or finer screens.. Fire Extinguishers with inspection tags must be positioned in accordance with applicable safety requirements. March 2011 Page 3 of 19

,2-5 Description of Compliant or Dust covers or other protective devices must be used to prevent debris from accumulating on mating surfaces of fuel loading couplers Fuel Facility Checks Records, paper or electronic must be completed by the person performing the tasks or by the person accepting responsibility for performance o f the task. Daily checks and inspections should be made at the beginning of each work day including weekends and holidays. Upon completion of the checks, results recorded in remark section and dated: S= satisfactory, C= Indicates a comment required Yard for appearance and cleanliness Evidence of recent fuel spill i.e. staining, strong fuel odor or fuel in catchment basins Security, Fire and Safety Deficiencies Fuel leaks evident,2-5 Daily Checks General condition of the tank yard Evidence of recent fuel spill i.e. staining, strong fuel odor or fuel in catchment basins Ensure all gates and fences are in good condition In unsecured areas all tank openings, valves, sump drains, fill caps, monitoring ports, loading/unloading hoses, master electrical witches and other accessible fittings must be kept closed and locked at all times when not in use Tank sumps Drain capacity of piping. Sample sufficient size sample, perform appearance test, record findings Continue to sump until clean dry fuel obtained Filter Differential Pressure, under normal flow, check and record differential pressure across all March 2011 Page 4 of 19

working filters. Hoses, Swivels, Nozzles and Couplers for condition, wear, damage and leakage Dust covers or other protective devices installed and available and in good repair Hoses for abrasions, cuts, soft spots, carcass separation, worn covers, blisters exposed reinforcement, cracks twists and sharp bends that give appearance of pending failure Swivel attachment screws tight of nose and poppet seals/couplers for cuts, nicks and wear Any item that is defective or leaking must be repaired or replaced Static reels, condition of reels, clamps and cables Continuity checks completed and documented March 2011 Page 5 of 19

Description of Compliant or Fire Extinguishers Verify that extinguishers: are located in their designated place, have unobstructed access and visibility, unbroken safety seals, no obvious physical damage, corrosion or leakage, pressure gauge in good range Monthly Checks Filtration (Millipore) & Free Water Test Perform and membrane color/particle (Millipore) simultaneously, under flow, upstream and downstream of each filter/separator and monitor vessel Perform a free water test downstream of each filter/separator and monitor vessel. Record results and attach test membrane to Form 103.8 or equal Correct filter differential pressure, under normal flow conditions, check and record observed differential pressure, flow rate and corrected differential pressure across each working filter. Bonding cable/system continuity, perform electrical continuity check on boding cables and clamps, resistance must be 25 ohms or less, defective equipment must be replaced Nozzle screens, remove nozzles and examine screens for particles or damage, if particle are found, investigate sources of contamination which could be from inner hose lining, pipe rust, sand, low point sediment, equipment failure, seals gaskets, etc. Screens are to be cleaned if contaminated or replaced if damaged Floating suction for all jet systems, verify March 2011 Page 6 of 19

Description of Compliant or Quarterly Checks Emergency Shutoff System, Operationally check the emergency shutoff system, each device must be tested annually Water defense system External Checks, check operation of water defense systems in accordance with quarterly requirements Tank high level controls, Check satisfactory operation of tank high level sensing devices and automatic fuel flow shutoff valves where installed, inoperative controls should be adjusted or repaired immediately or have alternate operating procedures in effect that will provide positive spill prevention while tank is in service Semi-Annual Checks Hose pressure checks, Loading/unloading hoses fitted with reusable couplings and being operated under system pressure must undergo the sixmonth pressure testing at 225 psi Annual Checks Storage tank interiors; check fuel storage tank interiors for cleanliness and condition of coating, clean as required. March 2011 Page 7 of 19

Description of Compliant or Tank Vents, Where installed, check cleanliness of tank vent screens, clean repair replace as needed Tank that have pressure/vacuum vents, check satisfactory operation and condition of poppets and inlet screens Cathodic protection, where installed, confirm satisfactory operation of cothodic protection systems. Line Strainers, check for cleanliness and damage. Clean or replace as required Water defense System Inspection and Test, check operation of water defense system in accordance with annual requirements Aircraft Fueling Equipment All aircraft fueling equipment must have a Filter/Separator or Full Flow Fuel Monitor All new vessels and element combinations shall meet API/IP 1581 latest edition. Filter/Separators must be equipped with and automatic water defense system that will cause fuel to stop flowing when activated by excessive water, water defense system must include provisions for an operational test. Full flow fuel monitors must meet the requirements of IP 1583 latest edition. March 2011 Page 8 of 19

Description of Compliant or Full flow fuel monitors must be equipped with a pressure limiting device that will prevent excessive differential pressure from damaging elements in the event of a complete blockage Fuel Flow Monitors will not be used with fuels containing FSII All filtration vessels must include: air elimination provisions, Direct reading differential pressure gauge with and accuracy of +/- 2 PSI, Manual sump drains, valves with handles spring loaded to the closed position are recommended, upstream and downstream membrane sampling connections, including probes and dust covers, Pressure relief valves or other device that will prevent over-pressurization due to thermal expansion of fuel. Pressure Controls All aircraft fueling equipment must have separate and independent primary and secondary pressure control devices. Primary pressure control is intended to protect the aircraft under conditions of constant flow and also from pressure surge caused during aircraft valve closure. Secondary pressure control is intended to protect the aircraft in the event of primary pressure control failure. Primary pressure control devices must limit fueling pressure, at the nozzle, to 40 psig or less under conditions of constant flow; secondary pressure control devices must limit fueling pressure, at the fuel nozzle, to 50 psig or less under conditions of constant flow. March 2011 Page 9 of 19

Description of Compliant or Deadman Control System All fueling equipment must have a hand held deadman control device. The deadman control system must completely sop fuel flow with 5 percent of the fuel flow rate at the time of release. Emergency Fuel Shutoff System Refueling trucks must be equipped with and emergency fuel shutoff control accessible from each side of the truck. Units equipped with a lift or platform must have an emergency fuel shutoff control accessible from the lift or platform, in addition to one accessible from the ground. The emergency fuel shutoff system should also be close to the tank outlet valve. Each emergency fuel shutoff control must completely stop fuel flow with a maximum of 5 percent overrun. Fire Extinguishers Refueling trucks must be equipped with a minimum of two 20BC rated fire extinguishers, securely mounted on opposite sides of the truck and readily available. Seals must be intact. Current inspection, testing and recharging records must be attached Safety Interlock System All mobile fueling equipment must have a safety interlock system which will prevent the equipment from being moved when: the couplers and/or nozzles are not in their stowed position; the pumping system is activated on tank trucks. The interlock system may stop the engine on motorized equipment, but should also apply the vehicle brakes. Refueling trucks with bottom loading provision shall incorporate a brake interlock system that will prevent the vehicle from being moved until the bottom loading coupler has been disconnected from the vehicle. March 2011 Page 10 of 19

Interlock systems shall be equipped with an override device which shall be sealed in the normal position with a breakaway seal. Placards must identify normal and override positions. Regulation, Code or Description of Compliant or Aircraft Fueling Hoses Hoses shall be installed within 2 years of DOM and have a maximum service life of 10 years from DOM Dust covers or other protective devices must be used Strainers and Swivels, aircraft fueling hoses must have a 100 mesh fuel screen. Aircraft Fuel Pressure Gauges A pressure gauge is required for monitoring aircraft fueling pressures. Gauges should be located where they will be visible to the equipment operator during aircraft fueling. Gauges will have a minimum diameter of 4 inches and musts have an accuracy of +/- 2% full scale March 2011 Page 11 of 19

Description of Compliant or Additional Requirements for Trucks Cargo tanks must be constructed of stainless steel, aluminum or internally light color epoxy coated carbon steel Dome covers must be provided with a forward mounted hinge and latches which will automatically close the cover to close and latch with forward motion of the vehicle. Water-tight, fuel resistant seals and gaskets Each tank compartment must be equipped with a water drain located at the lowest point, valve handles must be spring loaded to the closed position Tank outlets should be equipped with shutoff valves located inside the tank shell. Trucks with bottom loading capability must be equipped with a high level shutoff system. Provisions for ensuring the satisfactory operation of the system shall be included. March 2011 Page 12 of 19

Description of Compliant or Overwing Nozzle Spouts The prevent misfueling, overwing jet nozzles shall utilize a large wide diameter spout while avgas nozzles shall utilize a smaller diameter spout. Jet fuel nozzles spouts shall adopt an elongated or elliptical shape. Daily Checks of Refueler Trucks General condition, safety defects, trucks with leaks taken out of service Filter sumps Filter vessel under pressure, at least one gallon per sump, maximum flow, fuel appearance test, record findings. Truck removed from service if unable to obtain clean, dry sample after three samples. Filter differential pressure must be periodically monitored during fueling operation. Remove unit from service if a sudden drop in pressure is noted during use or if DP exceeds 15 psi Deadman Controls Perform a functionality check, remove from service is fails Safety Interlocks Verify proper operation Filter Differential Pressure Under normal flow, check and record DP March 2011 Page 13 of 19

Description of Compliant or Nozzle Fueling Pressure Check and record nozzle delivery fueling pressure, pressure monitored during fueling operation. Must not exceed 40 psig at contestant flow. Remove from service if psig exceed 50 Hoses, Nozzles & Swivels Check condition of fuel hoses, swivels, caracass separation, worn covers, blisters, exposed reinforcement, cracks, twists and sharp bends that give the appearance of pending failure. Check tightness and safety wiring of all swivel and collar attachment screws and hose couplings. Check condition of nose and poppet seals on nozzles for cuts, nicks and wear. Fire Extinguishers Located in their designated place, tagged, inspections current, unbroken seals, no obvious damage, pressure gauge in operable range March 2011 Page 14 of 19

Description of Compliant or Monthly Checks Perform membrane color/particle (Millipore) simultaneously, under flow, upstream and downstream of each filter/separator. Perform free water test downstream of each filter/separator and monitor vessel. Determine if corrected filter differential pressure using the appropriate manufacturer curve charts or programs Corrected Filter Differential Pressure Under normal flow conditions, check and record observed differential pressure, flow rate and corrected differential pressure across each working filter. Static System Continuity Test Perform electrical continuity check of static bonding system; resistance must be 25 ohms or less. Date: March 2011 Page 15 of 19

Nozzle Screens Examine each nozzle screen for particles or other solid contaminants, if particles are found, investigate possible sources of contamination, clean as necessary, verify screens are 100 mesh, damaged screens must be replaced Fuel Hoses Lay hoses out full length with system at full operating pressure and check hoses for abrasions, cuts, soft spots, carcass separation, worn covers, blisters, exposed reinforcement, cracks, twists and sharp bends that give the appearance of pending failure. Check couplings at both ends for cracks and signs of slippage or leakage Signs, Labels& Placards Product code, FLAMMABLE on each side and rear, NO SMOKING on at least two sides, NO SMOKING posted prominently in cab, EMERGENCY FUEL SUPPLY adjacent to each emergency shut off control, method of Emergency Fuel Shut Off operation, Fire Extinguisher location signs, Nozzle fueling pressure, Filter DP, Filter and Tank Drain valves, Date of last filter element change. Meter seals and calibration is intact and current March 2011 Page 16 of 19

Description of Compliant or Quarterly Checks Vehicle inspected thoroughly for excessive wear and pending failure Pressure controls, operator must have written test procedures specific to the vehicle pressure control system and test facilities at each location, check all primary and secondary pressure control equipment, record pressure settings Water Defense System Check Check operation of water defense system Internal Valve Check Test to ensure that the internal valve functions properly utilizing the pre-check test March 2011 Page 17 of 19

Semi-Annual Checks Hose pressure check, refueling hoses fitted with reusable couplings and being operated under system pressure must undergo the six-month pressure testing at 225 PSI Annual Checks Replace filter/separator filter elements Teflon and synthetic separator elements may be reused, provided they are cleaned and tested Full Flow monitor elements are to replaced annually A visual inspection of all vessel interiors, verify interior is clean, free of water, sediment, evidence of microbial growth or other contamination. Verify all elements are undamaged and secure Fueling pressure and DP Gauges, verify the accuracy of gauges used to monitor fuel delivery to aircraft is within +/- 2% of full scale. Verify proper operation of differential gauge(s) in accordance with manufacturer s recommendation. Meter Calibration, check accuracy of all aircraft fueling equipment meters. Water Defense System Inspection and Test, check operation of water defense system Procedures and Tests Appearance Tests: Refer to, 3-1 Membrane Color Filtration Test: refer to 3-2 Free Water Test: refer to 3-3 Fuel Density Test (API GRAVITY): refer to 3-4 Water Separation Test (MSEP): refer to ATA 103 3-5 Fuel Odor: refer to 3-6 Visual Detection of Microorganisms: refer to 3-7 Filter Vessel Differential Pressure: refer to March 2011 Page 18 of 19

3-9 Bonding Cable Continuity Check: refer to 3-10 March 2011 Page 19 of 19