HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED



Similar documents
SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

DIVISION 4300 STORM DRAINAGE

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Drainage Solutions and Water Treatment / Single-wall corrugated drainage tubing is ideal for agricultural and. Durable Economical Wide range of sizes

Fabricated Drainage Products

Use of Corrugated HDPE Products

Section 2100-Trenching and Tunneling

SECTION STORM DRAINAGE TABLE OF CONTENTS

SECTION NONREINFORCED CONCRETE SEWER PIPE

Royal Seal Gasketed Sewer Pipe

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION POLYVINYL CHLORIDE (PVC) PIPE

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SECTION 724 PIPE CULVERTS

Wastewater Capital Projects Management Standard Construction Specification

SANITARY SEWER SPECIFICATIONS

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

Nebraska Department of Roads Drainage and Erosion Control Manual December 2011 Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

PIPE INSPECTION AND REPAIR. Larry Ritchie

SECTION 701 CULVERT PIPE, ENTRANCE PIPE, STORM SEWER PIPE, AND EQUIVALENTS

BMP 6.4.6: Dry Well / Seepage Pit

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

SECTION POLYVINYL CHLORIDE (PVC) PIPE

INDEX. Sec. No. Items Page Nos.

PVC PIPE PERFORMANCE FACTORS

Section 402. STORM SEWERS

N-12 Pipe. The high-performance future of engineered drainage

City of West Linn Public Works Standard Construction Specifications. Table of Contents

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Section SEWER PIPE INSTALLATION AND TESTING

SECTION 7- STORM SEWER

Haviland Drainage Products Co. Box 97 Haviland, Ohio Ph. (419) Fax (419)

8-11 Structural Analysis and Fill Height Tables Pipe Cover Shallow Cover Installation Fill Height Tables...

CLEANING, INSPECTION, AND TESTING OF SEWERS

CULVERT AND STORM SEWER PIPE MATERIAL POLICY ON FEDERALLY FUNDED LOCAL AGENCY PROJECTS UPDATED March 2013

The Most Advanced Name in Drainage Systems. Geotextile Products

STANDARD SPECIFICATIONS & CONSTRUCTION DETAILS MANUAL SECTION 5 - STORM DRAINAGE Design

ITD Pipe Materials Selection & Specification Procedures. July 2011

SECTION STORM DRAIN SYSTEM

Stormwater/Wetland Pond Construction Inspection Checklist

SECTION STORM DRAINAGE SYSTEM

pvc well casing & drop pipe

CHAPTER 850 PHYSICAL STANDARDS

Collapse of Underground Storm Water Detention System

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Section 600 Incidental Construction

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Beacon Hill Sewer District Standard Specifications

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

BMP #: Dry Wells / French Drains

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

X Planning X Quality X Maintenance & Operations

LS 2540 SEWER LATERALS AND INSPECTION TEES

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

SECTION 200: STORM SEWER CONSTRUCTION STANDARDS

volume of concrete occupied by the drain pipe in a cast-in-place structure or structure extension.

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

1. ASTM C Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units

OAR52 A-1 (September, 1981)

SECTION 9. All sewer laterals shall tie into the sewer main lines unless approved by the City Engineer.

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

Gasketed PVC Sewer Pipe Durable, Flexible, Reliable Waterworks Products

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

SECTION 5: SANITARY SEWER SYSTEM DESIGN

STORM DRAINS CHAPTER 7

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

SECTION UNDERGROUND ELECTRIC SERVICE

Permeable Interlocking Concrete Pavements. The Stormwater Problem

CHAPTER 11 STORM DRAINAGE

ADS Water Quality Units

Suffolk County Department of Health Services. Division of Environmental Quality

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

Ultra-Rib PVC Storm Sewer Pipe 8" - 30"

INDEX STORM DRAINAGE PRE-APPROVED NOTES, DESIGN CRITERIA, & PLANS

Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS

(52) In6 Publication CCM2 May 2000 ADVANCED DRAINAGE SYSTEM CATCHPITS, CHAMBERS & MANHOLES RIDGIDRAIN ENGINEERING EXCELLENCE

Transcription:

QUALITY, PERFORMANCE AND ECONOMY COMBINED

LANE S HDPE DRAINAGE PIPE Scan for more information on Lane s HDPE product line. Lane provides the complete product line to meet all your HDPE drainage needs - the full range of diameters, in perforated or non-perforated patterns, along with custom fabricated fittings. Lane s HDPE pipe offerings can meet all the subsurface drainage demands of your site, building, roads and pavements. Whether made from prime virgin resins or with recycled materials, Lane s HDPE pipe has the strength and service life needed for your project. DID YOU KNOW? // HDPE pipe provides a greater service life and better life cycle cost than concrete pipe. About Lane As a full-line manufacturer of metal and plastic drainage products, Lane Enterprises, Inc., operates plants in the Mid-Atlantic and Northeastern states producing corrugated metal and plastic drainage pipe for the construction industry. For more than 75 years, Lane has partnered with contractors, engineers and municipalities to supply reliable products that provide the highest service life, strength, versatility and economy. Our focus on quality products, responsive customer service and technical expertise has afforded us a long history of successful partnerships within the industries we serve.

SPECIFY HD00 AND HD00EC PIPE HD00 and HD00EC are today s top two standard corrugated polyethylene drainage pipes featuring a dual wall, a smooth interior and the century-long service life your customers deserve. Specify HD00 to meet AASHTO M5 or M94 HD00 exceeds the AASHTO standards by using 00% virgin resins with enhanced long-term properties. Lane s higher material standards are aimed to ensure a minimum 00-year service life. Specify HD00EC to meet ASTM F648 HD00EC exceeds ASTM F648 by using an Engineered Compound with better long-term properties than required by ASTM and AASHTO. The Engineered Compound is designed to produce material properties capable of passing the industry s 00-year service life protocol. HD tough: High Density PE Heavy Duty Pipe High Durability Performance Exceeds material, performance and testing requirements of today s pipe standards Easily withstands the rigorous demands of the construction process Chemically inert with high stress crack and oxidation resistance Give it 00%: 00% virgin resin (HD00 only) 00-year service life, at a minimum! A Manning s roughness coefficient as low as 0.000 Use for 00-year service life applications may be subject to a local or state agency verification protocol. HD00EC IS green but doesn t cost you more of it: Produced from Engineered Compound utilizing recycled resins Eco-friendly product for the environmentally-conscious Use of recycled resins produces an efficient cost material MANNING S N-VALUE FOR DESIGN Tests consistently show a Manning s n in the range of 0.009 to 0.0. The major investigation (005 Utah State University) recognized an effective Manning s n as low as 0.00. Manning s n for design is conservatively factored to 0.0 for in-service performance. JOINT PERFORMANCE Bell and spigot joints with a factory-installed gasket meet the watertight requirements of ASTM D3 (laboratory pressure tested at 0.8 psi). LANE S HD00/HD00EC PIPE HD00 HD00EC Diameters Pipe Lengths Joints Manning s n meets AASHTO M5/94 meets ASTM F648 6-in through 48-in 0-ft (nominal) ASTM D3 Certified use n = 0.0 for design 3

INSTALLATION HD00/HD00EC interacts with select backfill and proper installation to form a composite structure. It is the resulting soil-culvert interaction system that defines the ability of HD00/HD00EC to withstand service loads. Standards for proper installation with guidelines in selecting pipe embedment material are found in ASTM D3. MINIMUM COVER HEIGHTS Minimum cover heights are typically assigned using industry established guidelines while maximum allowable burial depths vary considerably with the type of embedment material and the level of compaction, with the highest covers resulting from the use of manufactured aggregates. MINIMUM COVER HEIGHTS FOR LIVE LOADS Truck Loadings (H0, H5 or HL93) Minimum Cover for E-80 (Rail Road) Loads Temporary Cover for Construction Loads inches 4 inches to 4 feet May be subject to local or state agency minimum cover requirements. Cover for construction loads depends on pipe diameter and construction equipment (see table below). MINIMUM COVER FOR CONSTRUCTION LOADS (in) Nominal Pipe Diameter (ft) Axle Loads (kips) 8-50 50-75 75-00 0-50.0-3.0 4.0 30.0 36.0 36.0 3.5-4.0 36.0 36.0 4.0 48.0 MAXIMUM COVER HEIGHTS Maximum burial depths corresponding to the soil classification system of ASTM D3 are shown in the table below, with the best results obtained using manufactured or processed aggregates (i.e. crushed rock). Diameter (in) Lane HD00/HD00EC Pipe Allowable Burial Depths (ft) Class I Class II Class III Compacted Dumped 95% 90% 85% 95% 90% 85% 6 43 6 9 0 5 6 8 4 6 8 0 4 0 5 0 36 6 5 8 3 8 4 38 5 6 8 9 8 8 5 44 6 9 3 4 8 34 5 3 6 9 7 0 8 4 34 4 3 6 8 6 0 8 30 7 9 3 6 3 9 6 36 37 3 4 7 7 9 4 36 4 6 0 7 9 48 9 0 3 8 4 8 7. Installation in accordance with ASTM D3.. Class I indicates a soil that generally provides the highest soil stiffness at any given percent compaction, and provides a given soil stiffness with the least compactive effort. Each higher-number soil class provides successively less soil stiffness at a given compaction and requires greater compactive effort to provide a given level of soil stiffness. 3. All acceptable backfill materials are not presented here. See ASTM D3 for a complete listing of classifications. 4. Results based on the AASHTO LRFD design method using zero hydrostatic pressure and a soil density of 0 pcf. Greater cover heights are attainable with appropriate modifications to the design method - Contact Lane for further details. 5. Dumped Class I material is conservatively estimated at 85% maximum standard Proctor density. 4

PERFORATIONS Lane s perforated pipe offerings follow the AASHTO classification system and conform to AASHTO requirements for size, spacing and placement. CLASS PERFORATIONS (PARTIALLY PERFORATED PIPE) Class perforations are for pipe intended to be used for subsurface drainage or combination storm and underdrain. As such, the pipe maintains an unperforated segment above the invert to serve as a flow channel. Perforations are circular and arranged in rows parallel to the axis of the pipe with one perforation in each row for each corrugation. Rows of perforations are arranged in two equal groups placed symmetrically on each side of a lower unperforated segment corresponding to the flow line of the pipe. Nominal Inside Diameter (in) PIPE SIZES AND HANDLING WEIGHTS Actual Outside Diameter (in) Single-Wall Handling Weight (lbs/ft) Double-Wall Handling Weight (lbs/0ft) 4 4.75 0.35 3 n/a 6 7.05 0.90 5 8 9.40.50 40 0.00.50 50 4.50 3.5 75 5 7.50 5.30 0 8.50 6.5 50 4 8.00 9.90 40 30 34.50 n/a 350 36 4.00 n/a 45 4 47.50 n/a 575 48 54.50 n/a 650 Class Perforations Type SP AASHTO Type C (Type CP, Class and perforations) AASHTO Type S (Type SP, Class and perforations) 3 Available as a re-sale item through Lane D d WIA 0.3750 4.0 5 0.3750 3.04 8 0.3750.69 4 0.3750.68 30 0.3750.64 36 0.3750.6 4 0.3750.00 48 0.3750.00 to 8-inch Pipe Figure. Class Perforations 4 to 48-inch Pipe CLASS PERFORATIONS (FULLY PERFORATED PIPE) Class perforations are for pipe intended to be used for subsurface drainage only. Perforations may be circular or slotted and are uniformly spaced along the length and circumference of the pipe. Class Perforations Type SP D d WIA 0.35.85 5 0.35. 8 0.35.87 4 0.3750.68 30 0.3750.64 36 0.3750.6 4 0.3750.00 48 0.3750.00 d = diameter of circular perforation (in) l = average length of slotted perforation (in) w = average width of slotted perforation (in) 4 to 0-inch Pipe Class Perforations Type CP Type SP D l x w WIA WIA 4 0.783 x 0.069 4.0 n/a 6 0.769 x 0.055.46.63 8 0.759 x 0.050.79.87 0 0.779 x 0.054.4.3 to 8-inch Pipe Figure. Class Perforations D = nominal pipe diameter (in) WIA = water inlet area (in /ft) 4 to 48-inch Pipe 5

CORRUGATED HDPE DRAINAGE PIPE STANDARDS A number of different options are available beyond the standard 0-ft double-wall pipe offerings, including single-wall pipe (corrugated interior/exterior), perforated pipe, plain-end pipe (i.e. no bell/spigot), and coil pipe. Standards below encompass the complete line of corrugated HDPE pipe products for storm, land, and subsurface drainage applications, with each standard identifying the material, manufacture and workmanship requirements for the intended application: STANDARDs ASSOCIATED WITH LANE S CORRUGATED HDPE PIPE Standard Description Application AASHTO M5 Corrugated HDPE Pipe (3-0 ) Storm Sewers, Culverts, Subsurface Drainage Systems AASHTO M94 Corrugated HDPE Pipe ( - 60 ) Storm Sewers, Culverts, Subsurface Drainage Systems ASTM F306 Corrugated HDPE Storm Sewer ( - 60 ) Storm Sewers, Subsurface Drainage ASTM F405 Corrugated HDPE Pipe and Fittings (3-6 ) Soil Drainage, Septic Field Leach Beds ASTM F667 Corrugated HDPE Pipe and Fittings (3-4 ) Culverts, Subsurface Drainage ASTM F648 Corrugated HDPE Pipe and Fittings ( - 60 ) Culverts, Subsurface Drainage Standard requires virgin polyethylene resins. Lane s HD00EC pipe is identied with ASTM F648 because all other comparable standards have virgin material requirements while HD00EC is made from an engineered compound containing a recycled content. To maintain quality and ensure a long service life, Lane s HD00EC pipe is designed to exceed the material performance requirements of AASHTO M5/94. PIPE CLASSIFICATIONS Generally follow the AASHTO classification system: Specify Type S pipe for double-wall pipe (smooth interior, corrugated exterior). Specify Type SP pipe for double-wall perforated pipe. Specify Type C pipe for single-wall pipe (corrugated exterior and interior). Specify Type CP pipe for single-wall perforated pipe. Specify Class perforations for subsurface drainage or combination storm and underdrain. Specify Class perforations for fully perforated pipe to be used for subsurface drainage only. JOINT PERFORMANCE Bell and spigot joint performance designations relate the ability of the system to control leakage and/or material infiltration: Soil-tight joints prevent infiltration of soil particles larger than those passing a No. 00 Sieve. Silt-tight joints employ an elastomeric rubber seal and meet a laboratory pressure rating of at least psi. Water-tight joints are gasketed connections meeting a 0.8 psi laboratory test per ASTM D3. DID YOU KNOW? // Lane s HD00EC pipe qualifies for Recycled Content LEED credits. 6

SPECIAL APPLICATIONS LANE S COIL PIPE Consistent with Lane s commitment to high quality, coil pipe is produced using quality resins that ensure high strength and a long service life. Available in 4, 6 and 8 diameters, in perforated or non-perforated patterns, with a full range of fittings, Lane s coil pipe is made with resins that meet or exceed the standards set by pertinent DOT, forestry or agricultural agencies. Whether made with prime virgin resins or with a recycled content, Lane s coil pipe has the strength and service life needed for your project. Small Coil Maxi Coil DIAMETER L.F. L.F. lbs width x height 4 00, 50 3000 050 8.5 x 9.0 6 00 400 60 8.5 x 9.0 8 80 75 088 8.5 x 9.0 Product Options: 4, 6 and 8 Diameters Agricultural or DOT Grades Regular or Heavy Duty Perforated or Solid Wall Small or Maxi Coils Standard Couplers and Fittings CFT WATER QUALITY UNIT Solid Wall Applications: Roof Drains Downspouts Driveway Culverts Rear Yard Sump Mains Agricultural Mains Outlet Drains Perforated Applications: Athletic/Recreational Field Drainage Agricultural Drainage Golf Course/Landscape Drainage Retaining Wall Drain Highway Under Drain Foundation/Basement Drain Lane s Counter Flow Technology (CFT) water quality unit is a cost-effective and ecofriendly structural BMP designed to treat the first flush of a storm event by intercepting the flow, removing the pollutants, and re-introducing treated flow in a manner suitable for today s storm water regulators. Lane s CFT is manufactured from high-quality corrugated HDPE pipe and has no mechanical, moving or replacement parts, is less costly, more reliable, and offers better efficiency then comparable products. STANDARD FITTINGS AND CUSTOM FABRICATIONS Lane s fitting fabrication shop produces a full assortment of fittings and custom fabrications for all pipe diameters fittings for storm water storage, water quality devices, flow diversion chambers, orifice plates, weirs, trash racks, riser ladders, et al. Standard and special drawings are available to aid the designer in the use of corrugated HDPE for the varied applications. STORM WATER MANAGEMENT SYSTEMS Lane manufactures Storm Water Management Systems for detention, retention and infiltration purposes. As a manufacturer of both corrugated metal and polyethylene pipe, Lane enjoys the unique position of being able to supply whichever product is better suited for the project. Since Lane also manages 00% of the fabrication work for both standard and custom fittings, the customer can have the same superior quality in every piece delivered to the site. 7