ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions



Similar documents
ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

Lock Function Chart Page 1 of 7


Narrow stile lock 1314

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks

ABLOY EL420, EL520 Europrofile motor locks

BODY-12, Door Handle - Removal, Installation, and Adjustment

EXIT HARDWARE. Uniclass L CI/SfB (31.59) Xt7 VERSION: AUGUST-11. An ASSA ABLOY Group brand

PHA 2000 PHB 3000 EXIT PAD

Modular mortice locks

An overview of mechanical lock and security related standards and why they re important to the Insurance Industry

Exit Devices TABLE OF CONTENTS

What locks do I have Timber Doors

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY VEGA CABINET LOCKS

Panic & emergency exit devices

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

WE ARE UNION. replace with new shot. Mortice Lock Range. ASSA ABLOY, the global leader in door opening solutions

Key in Knob & Key in Lever

Troubleshooting: Door Jamming and Door Handing 6. Troubleshooting: Keypad 11. Troubleshooting: Battery 12. Battery FAQ 13

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

Mechanical Digital DX Locks

Security Screen Door Hardware

Decorative Lever Designs

RIM AND MORTICE LOCKS

Keypad Programming Instructions For the Access 800 TCAC2 Series Locks

PROOF ONLY. Police and Fire Service Home Security & Fire Safety Checklist. Student Accommodation Security Checklist

MB Architectural. Lloyd Worrall. Yannedis. London. GB nationwide. Belfast

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

GLOSSARY OF LOCK TERMINOLOGY

HARDWARE REQUIREMENTS FOR ACCESS AND EGRESS

SECURITY LATCH TM SIMPLE, SAFE & SECURE

Concealed Door Closers

Mortice Lock. ASSA ABLOY, the global leader in door opening solutions

Standard Door Specification

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

DECLARATION OF PERFORMANCE NO. HU-DOP_TN _001

RADAR

Décor / Colour. POUR VERRE DE 10 et 12 mm - FOR 3/8 & 1/2 GLASS. - Bec de cane - Peut être livré avec une béquille TC

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

Cabinet Locks. Benefits:

Relevant British, European and International standards

Keys Master, submaster and valet key Key number Door locks Power door locking switches

Keypad Programming Instructions for the Profile Series LK and v.g1 Locks

C A T A L O G U E c l i c k a n y w h e r e t o c o n t i n u e

Belt Sander. Given a properly adjusted belt sander, accessories, instruction and demonstration of use, each student will be able to:

SECURITY VS. EXITING... Door Locking Hardware in Schools DIVISION OF THE STATE ARCHITECT

High-speed folding doors. F Series

Euro Profile Mortice Locks

Protect your home with

Basic Technical Fundamentals of Builders Hardware Mortise, Bored and Auxiliary Locks

Sliding Door Hardware

Basic Technical Fundamentals of Builders Hardware

High-speed spiral doors for deep-freeze applications. TK Series

CISA Safe Home. Locks for shutters and security grates

a practical guide to home security.

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

Original Assembly Guide

Master Code 2. Troubleshooting: Installation 7. Troubleshooting: Door Jamming and Door Handing 8. Troubleshooting: Keypad 12

Classroom Door Security & Locking Hardware

COASTAL SERIES. 316 Solid Stainless Steel Door Furniture

ELECTRONIC KEYCARD ACCESS LOCKS

Table of Contents - 3 -

Understanding Access Control

PRODUCT INTRODUCTION PRECISION HARDWARE

KEY CYLINDER PLATFORMS

User Guide Premier Elite 24/48/88/168/640

EC-Certificate of Conformity Certificate CPD

ScanFlex lever handles

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

Happiness has many roots, but none more important than security. - E. R. Stettinius

Stand-alone Touchscreen Access Lock ANSI/BHMA Grade 1. An ASSA ABLOY Group brand

Technical Information

Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:

L Series. Commercial mortise locks

Dor-O-Matic Exit Devices

InSync Lock Series SAM RF Software. Key Control Systems for Multihousing

MagTek A. Aluminium Manual Attack Resistant Doors

Camlocks and Cupboard Locks

product brochure IMPLEMENTED

SAVE THIS MANUAL FOR FUTURE REFERENCE

GE Wireless Devices Battery Replacement

Folding Rule Rubber Cement Door Locks Step Ladder Spot Lights Outlet Box Power Drill Plug-in Timer Screwdriver Hand Drill Steel Rod Junction Box

White Papers: Delayed Egress Hardware

There is a jam at Tray 1 (MPT). Follow these steps to clear the jam. 1. Remove paper from Tray 1 (MPT).

Degree Key System. Technical Manual

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

Keys Master, submaster and valet key Key number

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

600 Series Camera. User Guide

User Manual (Password+RF Card+ +Mechanical Key)

Mechanical Pushbutton Locks Keyless Convenience

SAFE-O-TRONIC access Door and furniture locking systems

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

Transcription:

ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions

CONTENTS ABLOY LE180..3 ABLOY LE184..4 ABLOY LE185...5 ABLOY LE181..6 ABLOY LE183..7 ABLOY LE186..8 ABLOY LE310..9 ABLOY LE314 10 ABLOY LE315 11 ABLOY LE311 12 ABLOY LE313...13 ABLOY LE316...14 Mortises...15-16 Striker plates 17-18 2

ABLOY LE180 Exit lock cases with automatic deadlocking latchbolt for wooden doors with one blade. The door is opened from outside with a lever handle. The lock case fulfils the requirements of the European standard for exit products SFS-EN179 and SFS-EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. Deadlocking is controlled by a snib in the front plate. Using of the snib is normally blocked. The snib is released by turning the key. Snib position: UP = Deadlocking, latchbolt protrudes 17 mm The lock can be opened from outside by key only and from inside by a lever handle, push pad or panic bar. DOWN = Latchbolt protrudes 14 mm. The lock can be opened from outside by lever handle also. LE180X is the microswitch version of the lock. The switch changes the status when latchbolt is protruded from 14 mm to 17 mm. Following striker plates are recommended to be used with microswitch version: 4692, 4693. Striker plate LP711, LP714, LP721, LP731 Fire resistance Yes Mortise standard Special mortise 3

ABLOY LE184 Exit lock case with automatic deadlocking latchbolt for wooden doors with one blade. The door is opened from outside with a door pull. The lock case fulfils the requirements of the European standard for exit products SFS-EN179 and SFS- EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The lock is deadlocked always when the door is closed. Latchbolt protrudes 17 mm. LE184X is the microswitch version of the lock. The switch changes the status when latchbolt is protruded from 14 mm to 17 mm. Following striker plates are recommended to be used with microswitch version: 4692, 4693. Striker plate LP711, LP714, LP721, LP731 Fire resistance Yes Mortise standard Special mortise 4

ABLOY LE185 Exit lock case with automatic deadlocking latchbolt for wooden doors with one blade. The door is opened from outside with a door pull. The lock case fulfils the requirements of the European standard for exit products SFS-EN179 and SFS-EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. Deadlocking is controlled by a snib in the front plate. Using of the snib is normally blocked. The snib is released by turning the key. Snib position: UP = Deadlocking, latchbolt protrudes 17 mm The lock can be opened from outside by key only and from inside by a lever handle, push pad or panic bar. DOWN = Latchbolt is retained inside the lock case. LE185X is the microswitch version of the lock. The switch changes the status when latchbolt is protruded from 14 mm to 17 mm. Following striker plates are recommended to be used with microswitch version: 4692, 4693. Striker plate LP711, LP714, LP721, LP731 Fire resistance - Mortise standard Special mortise 5

ABLOY LE181 Exit lock case with automatic deadlocking latchbolt for the active side of wooden doors with two blades. The door is opened from outside with a lever handle. The lock case fulfils the requirements of the European standard for exit products SFS-EN179 and SFS- EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The latchbolt protrudes 14 mm. Deadlocking is controlled by a snib in the front plate. Using of the snib is normally blocked. The snib is released by turning the key. Snib position: UP = Deadlocking The lock can be opened from outside by key only and from inside by a lever handle, push pad or panic bar. DOWN = Day latching, the lock can be opened from outside by lever handle also LE181X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Passive lock case PE911 Fire resistance Yes Mortise standard Special mortise 6

ABLOY LE183 Exit lock case with automatic deadlocking latchbolt for the active side of wooden doors with two blades. The door is opened from outside with a door pull. The lock case fulfils the requirements of the European standard for exit products SFS-EN179 and SFS- EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The lock is deadlocked always when the door is closed. The latchbolt protrudes 14 mm. LE183X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Passive lock case Finish Fire resistance Mortise standard PE911 Fe/ZNCRLQ Yes Special mortise 7

ABLOY LE186 Exit lock case with automatic deadlocking latchbolt for the active side of wooden doors with two blades. The door is opened from outside with a door pull. The lock case fulfils the requirements of the European standard for exit products SFS-EN179 and SFS- EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The latchbolt protrudes 14 mm. Deadlocking is controlled by a snib in the front plate. Using of the snib is normally blocked. The snib is released by turning the key. Snib position: UP = Deadlocking The lock can be opened from outside by key only and from inside by a lever handle, push pad or panic bar. DOWN = Latchbolt is retained inside the lock case. LE186X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Passive lock case PE911 Fire resistance - Mortise standard Special mortise 8

ABLOY LE310 Exit lock case with automatic deadlocking latchbolt for profile doors with one blade. The door is opened from outside with a lever handle. The lock case fulfils the requirements of the European standard for exit products SFS-EN179 and SFS-EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The latchbolt protrudes 14 mm. Deadlocking is controlled by a snib in the front plate. Using of the snib is normally blocked. The snib is released by turning the key. Snib position: UP = Deadlocked The lock can be opened from outside by key only and from inside by a lever handle, push pad or panic bar. DOWN = Day latching, the lock can be opened from outside by lever handle also. LE310X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Striker plate 4613, 4614 Fire resistance Yes Mortise standard Mortise for profile door lock cases 9

ABLOY LE314 Exit lock case with automatic deadlocking latchbolt for profile doors with one blade. The door is opened from outside with a door pull. The lock case fulfils the requirements of the European standard for exit products SFS- EN179 and SFS-EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The lock is deadlocked always when the door is closed. The latchbolt protrudes 14 mm. LE314X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Striker plate 4613, 4614 Fire resistance Yes Mortise standard Mortise for profile door lock cases 10

ABLOY LE315 Exit lock case with automatic deadlocking latchbolt for profile doors with one blade. The door is opened from outside with a door pull. The lock case fulfils the requirements of the European standard for exit products SFS- EN179 and SFS-EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The latchbolt protrudes 14 mm. Deadlocking is controlled by a snib in the front plate. Using of the snib is normally blocked. The snib is released by turning the key. Snib position: UP = Deadlocked The lock can be opened from outside by key only and from inside by a lever handle, push pad or panic bar. DOWN = Latchbolt is retained inside the lock case. LE315X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Striker plate 4613, 4614 Fire resistance - Mortise standard Mortise for profile door lock cases 11

ABLOY LE311 Exit lock case with automatic deadlocking latchbolt for the active side of profile doors with two blades. The door is opened from outside with a lever handle. The lock case fulfils the requirements of the European standard for exit products SFS- EN179 and SFS-EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The latchbolt protrudes 14 mm. Deadlocking is controlled by a snib in the front plate. Using of the snib is normally blocked. The snib is released by turning the key. Snib position: UP = Deadlocked The lock can be opened from outside by key only and from inside by a lever handle, push pad or panic bar. DOWN = Day latching, the lock can be opened from outside by lever handle also. LE311X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Passive lock case PE901 Fire resistance Yes Mortise standard Mortise for profile door lock cases 12

ABLOY LE313 Exit lock case with automatic deadlocking latchbolt for the active side of profile doors with two blades. The door is opened from outside with a door pull. The lock case fulfils the requirements of the European standard for exit products SFS-EN179 and SFS- EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The lock is always deadlocked when the door is closed. The latchbolt protrudes 14 mm. LE313X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Passive lock case PE901 Fire resistance Yes Mortise standard Mortise for profile door lock cases 13

ABLOY LE316 Exit lock case with automatic deadlocking latchbolt for the active side of profile doors with two blades. The door is opened from outside with a door pull. The lock case fulfils the requirements of the European standard for exit products SFS- EN179 and SFS-EN1125 and the requirements of the lock case standard SFS-EN12209. The lock is always opened from the inside by a lever handle, push pad or panic bar. The latchbolt protrudes 14 mm. Deadlocking is controlled by a snib in the front plate. Using of the snib is normally blocked. The snib is released by turning the key. Snib position: UP = Deadlocked The lock can be opened from outside by key only and from inside by a lever handle, push pad or panic bar. DOWN = Latchbolt is retained inside the lock case. LE316X is the microswitch version of the lock. The switch changes the status when latchbolt is deadlocked. Passive lock case PE901 Fire resistance - Mortise standard Mortise for profile door lock cases 14

MORTISE PICTURES LE180, LE181, LE183, LE184, LE185, LE186 15

MORTISE PICTURES LE310, LE311, LE313, LE314, LE315, LE316 Opening face A= Outside B= Inside 16

STRIKER PLATES 4613 4614 LP711 LP714 17

STRIKER PLATES LP721 LP731 18

19

20