Sugar Inversion and Brix in Soft Drinks: Cobrix3 multibev Measures Both!



Similar documents
Density/Specific Gravity/ Concentration Meter DMA 500

Density and Refractometry

About Coffee and Refractometers Voice Systems Technology, Inc. (VST)

Portable Density/Specific Gravity/Concentration Meter DMA 35

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

R013 Determination of dissolved solids (Brix) - A comparison of methods based on refractometers and density meters

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Coriolis Flow meters. Product family introduction Principle of operation Product review Applications Key product features

Metabolism: Cellular Respiration, Fermentation and Photosynthesis

The functional properties of sugar

T U R B I N E G A S M E T E R

THE USE OF A CORIOLIS FLOW METER FOR MEASURING MOLASSES PRODUCTION IN A SUGAR MILL. ABSTRACT

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

COMBIMASS. Technical Data COMBIMASS eco-bio +

Accurate Air Flow Measurement in Electronics Cooling

The photoionization detector (PID) utilizes ultraviolet

TEACHER ACTIVITY GUIDE

The polarity of water molecules results in hydrogen bonding [3]

Carbon Dioxide and an Argon + Nitrogen Mixture. Measurement of C p /C v for Argon, Nitrogen, Stephen Lucas 05/11/10

GREISINGER electronic GmbH

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

The Unique Accelabar Flow Meter

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Sanitary Type Electronic Flow Switches

Molar Mass of Butane

sugar sugar products for your sweet success

What are the similarities between this equation for burning glucose and the equation for cellular respiration of glucose when oxygen is available?

ORGANIC SAMPLE PREPARATION

THE HUMIDITY/MOISTURE HANDBOOK

ph and Acidity in Wine and Fruit Juice

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

USING THE FOOD LABEL TO FIND ITEMS THAT MEET THE EAT SMART IN PARKS GUIDELINES

Online Infrared Flue Gas Analyzer Gasboard 3000

Chapter 5 Student Reading

MEMBRANE FUNCTION CELLS AND OSMOSIS

For Multi-Parameter Meters see mvx

Testing methods applicable to refrigeration components and systems


Objectives of the review. Sources of information MARKET RESEARCH REPORTS

Warm-Up 9/9. 1. Define the term matter. 2. Name something in this room that is not matter.

- 1 - BISC 367 Plant Physiology Laboratory SFU

Necessary equipment. - Food grade fermenter or bucket with airtight lid - Airlock - Syphon tube - Bottles or a pressure barrel (keg) with S30 valve

Chapter 2 Chemical and Physical Properties of Sulphur Dioxide and Sulphur Trioxide

Biology for Science Majors

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Chapter 14 Solutions

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010

Power consumption (kw)

Balancing chemical reaction equations (stoichiometry)

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Beer Styles for the Novice Your Brew Day Sanitation

Distillation of Alcohol

Thermal Mass Flow Meter (Series MST)

HEINRICH FRINGS INFORMATION

Calculation of Molar Masses. Molar Mass. Solutions. Solutions

IB Chemistry 1 Mole. One atom of C-12 has a mass of 12 amu. One mole of C-12 has a mass of 12 g. Grams we can use more easily.

Open channel & partially filled pipe Ultrasonic flow meters

- thus, the total number of atoms per second that absorb a photon is

Using meters to measure steam flow

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)

Experiment 5: Phase diagram for a three-component system (Dated: April 12, 2010)

Metering for today s systems

HVAC Processes. Lecture 7

PARALLEL AUTOCLAVABLE MINI FERMENTERS/ BIOREACTORS

Digital inductive conductivity transmitter

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Soil Suction. Total Suction

IFC 070 Technical Datasheet

Fiscal Measurement Natural Gas

Chemistry 51 Chapter 8 TYPES OF SOLUTIONS. A solution is a homogeneous mixture of two substances: a solute and a solvent.

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Empirically Measuring and Calculating Alcohol and Extract Content in Beer with a Reasonable Degree of Accuracy and Confidence

ngenieros Ingenieros Asociados De Control S.L.

5. Which temperature is equal to +20 K? 1) 253ºC 2) 293ºC 3) 253 C 4) 293 C

How To Use A Flowmeter

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Enzyme Action: Testing Catalase Activity

Lab 3 Organic Molecules of Biological Importance

A new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications

In-Line Electronic Flow Switches

Precision Mass Flow Meters / Controllers for Liquids and Gases

PRODUCT PROFILE FEATURES

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Electronic Flow Switches

Lab 6: Paper Chromatography. Pages Pre-lab page 151 No Post lab Chromatogram must be turned in attached to lab report

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

4.4 Calculations Involving the Mole Concept

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

Custody Transfer Measurement. with the V-Cone Flowmeter

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

Energy Conservation Opportunities in Carbonated Soft Drink Canning/Bottling Facilities. Ahmad R. Ganji, Ph.D., P.E. + Bryan Hackett and Sandra Chow

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Energy and Flow Measurement for Hydronic Systems

Regards from the Team at Rheology Solutions.

Android based Alcohol detection system using Bluetooth technology

Transcription:

Sugar Inversion and Brix in Soft Drinks: Cobrix3 multibev Measures Both! 1. Introduction Soft drinks are produced from syrup (or concentrate), water and carbon dioxide. An important quality control parameter during production is the density of the syrup and the finished product, mainly reflecting the concentration of sweetener. For further details, see the Anton Paar's process application note On-line Density Measurement in the Soft Drink Industry [ 1 ]. The recipe for the production of a specific soft drink is either based on the sucrose concentration in the fresh product or total inverted product. Since the density of a sugar solution increases during storage, density measurement does not give precise information about the real initial sucrose content. Degree of Brix Sugar (= saccharose = sucrose) is the traditional sweetener used for the production of soft drinks and is derived from cane or beets. Its concentration is given in Brix (= %w/w). 100% 10.5 Brix Soft drink producers who use sucrose as the sweetener face the problem of sugar : During storage, sucrose solutions undergo a slow conversion into a 1:1 mixture of glucose and fructose, also called invert sugar. Each molecule of sucrose splits into one molecule of glucose and one molecule of fructose (see fig. 1) at the same time consuming one molecule of water. This "sugar " is enhanced by the presence of acids (contained in most beverages) and by elevated temperatures. Due to the process, the density of the sugar solution increases causing a considerable change in the Brix value e.g. from 10.40 Brix (Brixfresh) to 11.98 Brix (Brix-inverted). Depending on degree the Brix value (Brix-actual) will lie between Brix-fresh value and Brix-inverted value. Sucrose Glucose Fructose + H 2 O Glucose Fructose 0% 10 Brix time Fig. 2 Degree of over time Constant product quality of a soft drink greatly depends on the correct mixing ratio of the syrup with water. This mixing ratio can only be determined if the original sucrose concentration ( Brix-fresh) or the glucose- und fructose concentration at complete (Brix-Inverted) of the syrup is known. The determination of Brix-fresh from partially or completely inverted syrups is therefore very important. For QC purposes the Brix-fresh or the Brix-inverted of finished products must also be determined. Since the density changes during storage depending on the degree of, Brix-fresh or Brix-inverted is the only meaningful result which can be used to compare different production batches. Fig. 1 The sugar process E-mail: info@anton-paar.com Page 1 of 5

2. Determination of Brix-fresh and Brixinverted There are 2 ways to determine the Brix-fresh and Brix-inverted of an inverted sucrose solution: (1) The traditional Forced Inversion Method : All the sucrose is forced to invert fully by adding acid and increasing the temperature. The final solution contains invert sugar (1:1 mixture of fructose and glucose). By measuring the density using the corresponding tables it is possible to determine the invert sugar concentration and calculate the original sucrose content (= Brix-fresh). (2) The more convenient Anton Paar Method : The density and sound velocity of the partially inverted sample are measured and Brix-fresh or Brix-inverted is automatically calculated using a special software. The principle of the calculation is described below [ 2 ]. Figure 3 shows the dependence of density and sound velocity on pure sucrose and invert sugar concentrations with increasing concentration. Fig. 4 Determining the compensated density To calculate the density of the initial sucrose solution, a line parallel to the line has to be drawn through this measuring point. The crossing point of this line with the sucrose line gives the density of the initial sucrose solution. The crossing point of this line with the inverted sugar line gives the density of completely inverted solution (see fig. 4.). The quality control of inverted sugar solutions in the laboratory is carried out using the DSA 5000 Soft Drink Analyzer from Anton Paar. The compensation of the measured density and the calculation of Brix-fresh are performed automatically (see figure 3). For further information, see Anton Paar's application note Sugar Inversion and Brix in Soft Drinks: DSA 5000 Measures Both! [ 3 ]. For the on-line quality control of inverted soft drinks the Cobrix3 multibev beverage analyzer for sugar is used. Fig. 3 Density and sound velocity dependent on sucrose and invert sugar concentrations Partially inverted sucrose solutions contain both, invert sugar and sucrose. The density and sound velocity measuring points are therefore located between the two lines. The Cobrix3 multibev measures density, sound velocity, temperature and CO 2 content simultaneously. The measured density is compensated for temperature and CO 2 (measured with the integrated CARBO 2100 CO 2 transducer). The density reading is also compensated for sugar using the sound velocity reading (see fig.5). E-mail: info@anton-paar.com Page 2 of 5

the tube. Sound velocity is measured by an ultrasonic transmitter and receiver located on one side of the U-tube. The electronics measures the propagation time of the ultrasonic pulses through the sample and calculates the sound velocity. Information on the oscillation period, sound velocity and temperature is transferred to the evaluation unit and used for the calculation of concentrations. When measuring carbonated soft drinks, the influence of carbon dioxide has to be considered as well. CO 2 measurement is performed with the CARBO 2100 CO 2 transducer. 3.2 Carbon dioxide measurement Fig. 5 Determining the and CO 2 compensated density 3. On-line measuring principles 3.1 Density and sound velocity measurement Fig. 7 Measuring principle of the CARBO 2100 The method for determining the CO 2 content is based on Henry s Law, which defines the relationship between the concentration of the dissolved gas and its saturation pressure. A sample of the product is separated in a small measuring chamber. A special Anton Paar degassing device brings the chamber pressure to the corresponding saturation pressure within a few seconds. Then the saturation pressure and the temperature of the sample are measured and the content of dissolved CO 2 is calculated and used for density compensation. The measurement is repeated every 15 seconds. Fig. 6 Diagram of a DSRn transducer The conversion of saturation pressure and temperature into a CO 2 content is based on the formulas by Prof. Dr. Manfred H. Pahl, Dipl. Ing. Markus Rammert, University Paderborn [ 4 ]. In the Anton Paar DSRn transducer, density is measured according to the oscillating U-tube technique. The U-shaped sample tube is made of Hastelloy C276 and is excited to a continuous oscillation at its natural frequency by means of a magneto-electrical excitation system. The oscillation frequency is related to the density of the sample flowing through E-mail: info@anton-paar.com Page 3 of 5

4. The Cobrix3 multibev for sugar Cobrix3 multibev for sugar consists of density sensor for Brix and %Diet analysis sound velocity sensor for - automatic compensation of sugar - determination of alcohol content CO 2 Transducer for carbon dioxide determination data processing unit pump with new liquid sensor and pump control flow monitor process-matched IP 55 (NEMA) housing and frame DAVIS data acquisition and control software for Windows TM measures density, sound velocity, carbon dioxide (CO 2 ), temperature performs automatic, temperature and CO 2 correction of density determines Brix-fresh Brix-inverted Brix-actual % Diet % Alcohol Density Extract Original extract Actual extract apparent extract Fermentation degree CO2 Line pressure Temperature NaOH concentration etc. The Cobrix3 multibev is a compact system with all its components (DSRn, CARBO 2100, mpds 2000V3, valves, pump, ) mounted onto a rack. Within one day the system is installed and ready to go. The compact design of the Cobrix3 multibev guarantees optimal measuring conditions (constant flow rate, ). The Cobrix3 multibev provides real-time data of the measured parameters, activates alarms if preselected concentration limits are exceeded and provides signals for controller or recording devices. The Windows TM based DAVIS software is easy to use and performs data acquisition and statistical analysis for different products. Measuring data are displayed in diagrams that facilitate the monitoring of the production process. For practical information on the Cobrix3 multibev with sugar compensation, see the report QC in real-time in Beverage World International, Nov/Dec 1998. 5. Applications and benefits 5.1. Installation of Cobrix3 multibev at the Filler The on-line quality control of inverted soft drinks at the filler can be carried out using the Cobrix3 multibev beverage analyzer for sugar. Brix-fresh, Brix-inverted, Brix-actual and the CO 2 content are continuously monitored to assure constant product quality. Fig.8 Inversion over time Benefits: Elimination of out-of-specification products Improvement of production efficiency by significant savings of syrup and CO 2 Quick identification of production problems Traceable quality, automatic storage and recording of all relevant data E-mail: info@anton-paar.com Page 4 of 5

5.2. Quality control of syrup For the determination of the original sugar content in the syrup ( Brix-fresh) or the glucose and fructose concentration at complete (Brix-inverted) a DSRn density and sound velocity transducer with mpds 2000V3 evaluation unit is used. Benefits: Syrup quality is continuously monitored at every stage of sugar. Basis for the correct mixing ratio of syrup with water for soft drink production. 8. Summary Anton Paar equipment provides continuous and automatic measurement of Brix-fresh, Brix-actual, % Diet and carbon dioxide content directly on the soft drink production line. High accuracy and repeatability as well as long-term reliability are guaranteed. Over the years Anton Paar equipment has become a standard in on-line beverage quality control. 6. Technical Data 9. References Measuring range Sugar: 0 to 80 Brix, 0 to 200 %Diet Temperature: 0 to 105 C CO 2 : 0 to 10 Vol (= 0 to 20 g/l) Temperature: -5 to 30 C Max. pressure: 10 Bar Max. sample temperature: 121 C Ambient condition: Temperature: 0 to 35 C humidity: 10 to 90 %, not condensed 7. Measuring accuracy Density and sound velocity Based on density and sound velocity measurements, the Cobrix3 multibev determines the sugar concentration with an accuracy of ± 0.02 Brix and the diet concentration with typical accuracy of 0.5 % Diet. CO 2 content The accuracy in CO 2 determination is limited to ± 0.025 Vol (= 0.05 g/l) due to varying sample compositions. [ 1 ] On-line Density Measurement in the Soft Drink Industry, Anton Paar Process application note [ 2 ] (a) Determination of the concentrations of soft drinks containing sucrose taking into account the sugar, H. Stabinger, H. Heimel, S. Reichenpfader, E. Zwangsleitner, Mitteilungen aus dem Labor für Meßtechnik 3-10/1991. (b) Brix Measurement on Soft Drinks Using the Anton Paar DSA 48, Test Report Swiss Lab, 1995. [ 3 ] Density Measurement in the Soft Drink Industry, Anton Paar Lab application note [ 4 ] M. Rammert, M. H. Pahl, Die Löslichkeit von Kohlendioxid in Getränken, Brauwelt 12, 488-499 E-mail: info@anton-paar.com Page 5 of 5