screw-retained crown using a PEEK temporary abutment



Similar documents
screw-retained single crowns using custom-cast abutments

ball abutment overdenture: chairside pick-up using existing denture

Multi-unit abutment bar overdenture

procedures & products NOBELESTHETICS including Procera

One Abutment - One Time

Procedures & Products. NobelEsthetics

prosthetic technique manual

Restorative Guidelines

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

platform shifting Nobel Biocare is shifting gingival beauty to the next level

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Implant Bar Overdenture Utilizing Locator Attachments

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

While the prosthetic rehabilitation of

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Gl GinGival level implant

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Encode Restorative System Procedure & Laboratory Manual

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Product Catalog. ERA Mini TM Dental Implant System

Prosthodontist s Perspective

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

NARROW DIAMETER implant

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

GINGIVAL LEVEL implant

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Restorative Manual Impression Transfer System

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Straumann Bone Level Tapered Implant Peer-to-peer communication

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

Procedures & Products Powered by Procera. All-on-4

Implant Parts. A Radford Heath Guide 1

LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants

TRI-CAM Implant System

More than a fixed rehabilitation.

Dental Updates. Excerpted Article Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS

Regular C/X Prosthetics. Prosthetics

All-on-4 treatment concept with NobelSpeedy Groovy

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Virtual Implant Placement 2.1. catalog & surgical manual

IMPLANTS IN FOCUS. Endosseous dental implant restorations PLANNING FOR IMPLANT RESTORATIONS

NobelActive. procedures and products

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

Standard Internal Hex

Implants in your Laboratory: Abutment Design

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection

ADA Insurance Codes for Laboratory Procedures:

LOCATOR BAR ATTACHMENT SYSTEM

Dental Implant Restoration

THE LOCATOR OVERDENTURE IMPLANT SYSTEM.

ATLANTIS abutments as individual as your patients

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Accelerated Patient Rehabilitation

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

Nobel Clinician - Quick Guide

uncompromised strength, proven success external implant system

ERA. Attachment Systems. A SNAP to Use and Maintain

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

portion of the tooth such as 3/4 Crown, 7/8Crown.

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

ANKYLOS. Syncone Concept. The Paradigm For Implant Supported Dentures. Redefining Success In Implant Dentistry

páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí

Navigator System For CT Guided Surgery Manual

Simpl Implant Abutments with Atlantis CAD CAM Technology

Don t Let Life Pass You By Because Of Oral Bone Loss

AT THE RIGHT PRICE. ONE SIZE FITS ALL. FRICTION For a secure connection. BONEADAPT For immediate stability.

Titanium Base for CAD/CAM For single-tooth and bridge solutions

Single anterior tooth replacement: clinical approaches

There When You Need Them: 10 Principles of Successful RPD Treatment

education Although demographic factors and growing patient awareness of the benefits of dental implants

Implant systems Systematically perfect

Renaissance of One-Piece Implants

BICON DENTAL IMPLANTS

Clinical Perspectives

THE EVOLUTION OF EXTERNAL AND INTERNAL IMPLANT/ABUTMENT CONNECTIONS

How To Use A Cresco

Final Result 1 year later. Patient Case 19. Preoperative: Main Complaint:

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

CUSTOMIZED PROVISIONAL ABUTMENT AND PROVISIONAL RESTORATION FOR AN IMMEDIATELY-PLACED IMPLANT

Legacy3 System Overview Catalog. alog. 3.2mmD 3.7mmD 4.2mmD. Legacy mmD 5.2mmD 5.7mmD

THE PROFILE PROSTHESIS: AN AESTHETIC FIXED IMPLANT- SUPPORTED RESTORATION FOR THE RESORBED MAXILLA

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Dr. Abhinav Gupta M.D.S., Certificate D.G.O.I.( Implants) Assistant Professor(Prosthodontics) Dental College, A.M.U., Aligarh.

Healing Abutment Selection. Perio Implant Part I. Implant Surface Characteristics. Single Tooth Restorations. Credit and Thanks for Lecture Material

INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL

BioHorizons Education Programme 2015

SURGICAL MANUAL. Step By Step Techniques

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.

Crown and Bridge Restorations. Straumann synocta Prosthetic System

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

Transcription:

screw-retained crown using a PEEK temporary abutment This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual, please visit www.biohorizons.com/prostheticmanual.aspx

temporary restorations screw-retained crown using a PEEK temporary abutment Use this technique for the fabrication of short term (30 days), screw-retained single or multi unit temporary restorations. Temporaries may be used at the time of surgery, uncovery, or following an implant-level impression. component options PEEK temporary abutment.050 (1.25mm) hex driver torque wrench abutment prepping handle direct coping screw 1 Remove the healing abutment Remove the healing abutment using an.050 (1.25mm) hex driver. Make sure the prosthetic platform is free of bone and soft tissue. 2 Seat the PEEK abutment Seat the plastic temporary abutment, engaging the hex of the implant. Hand tighten the abutment screw using an.050 (1.25mm) hex driver. 3 Mark the abutment Evaluate inter-occlusal dimensions, angulation, and tissue contour. Mark the abutment for the required vertical reduction and gingival contour. Important: Maintain at least 3mm of the abutment height to avoid damaging the abutment screw. Page 1 of 4

temporary restorations screw-retained crown using a PEEK temporary abutment 4 Modify the abutment Remove the marked plastic abutment from the model and place it on the abutment prepping handle using an.050 (1.25mm) hex driver and hand tighten. Modify the abutment for vertical clearance and gingival margins using a carbide or acrylic bur. Note: Replace the healing abutment immediately to prevent soft tissue collapse over the implant. 5 Create undercuts Add undercuts to the surface of the modified abutment for mechanical retention of the acrylic. 6 Try in the shell crown Verify the implant prosthetic platform is free of bone and soft tissue. Irrigate the internally-threaded connection of the implant and dry. Place the modified abutment onto the implant using the abutment screw and an.050 (1.25mm) hex driver. Hand tighten. Try in the appropriate poly-carbonate/shell crown and modify as needed. 7 Create an access hole Remove the abutment screw from the modified plastic abutment and replace it with the direct coping screw using an.050 (1.25mm) hex driver. Create a screwaccess hole through the shell crown allowing the direct coping screw to come through. Finger tighten using the knurled top or hand tighten using an.050 (1.25mm) hex driver. Page 2 of 4

temporary restorations screw-retained crown using a PEEK temporary abutment 8 Fill the shell crown Mix acrylic or another material of choice and place inside the shell crown. Position the shell crown over the direct coping screw onto the modified plastic abutment. Note: Undercuts on adjacent teeth should be blocked-out prior to this reline procedure. 9 Remove and polish the crown Remove the direct coping screw and the relined shell crown using an.050 (1.25mm) hex driver. Place the screw-retained temporary crown onto the abutment prepping handle using the abutment screw. Contour and polish the temporary crown. 10 Re-seat the crown Make sure the implant prosthetic platform is free of bone and soft tissue. Irrigate the internal connection of the implant and dry. Try in the prosthesis to confirm fit and contour. Modify as necessary and polish after making adjustments. Re-seat the prosthesis onto the implant and hand tighten the abutment screw using an.050 (1.25mm) hex driver. Note: Take a radiograph along the long axis of the implant to ensure the abutment is seated completely onto the implant. Page 3 of 4

temporary restorations screw-retained crown using a PEEK temporary abutment 11 Check and modify the temporary Check the occlusion and contacts. There should only be light contact in centric occlusion and no contact in lateral excursions. Modify as necessary and polish after making adjustments. 12 Tighten the abutment screw Tighten the abutment screws to 30 Ncm using a calibrated torque wrench and an.050 (1.25) hex driver. Note: Tightening the abutment screw to 30 Ncm is not recommended if the temporary is placed at the time of surgery. 13 Fill the screw access channel Place a resilient material of choice (gutta-percha, silicone or temporary filling material) into the screw access channel. This allows for easy access to the abutment screw in the future. Fill the remainder of the channel using a composite resin material of choice. Take an x-ray for temporary prosthesis delivery records. Page 4 of 4

notes

notes

direct offices BioHorizons USA 888-246-8338 or 205-967-7880 BioHorizons Canada 866-468-8338 BioHorizons Spain +34 91 713 10 84 BioHorizons UK +44 (0)1344 752560 BioHorizons Germany +49 761-556328-0 BioHorizons Australia +61 2 9317 6800 BioHorizons Chile +56 (2) 23619519 distributors For contact information in our 85 markets, visit www.biohorizons.com BioHorizons, Laser-Lok, MinerOss, AutoTac, Mem-Lok and TeethXpress are registered trademarks of BioHorizons. Unigrip is a trademark of Nobel Biocare AB. Zimmer Dental ScrewVent and Tapered ScrewVent are registered trademarks of Zimmer, Inc. AlloDerm and AlloDerm GBR are registered trademarks of LifeCell Corporation. The ARTISAN Space Maintenance System and Grafton DBM are registered trademarks of Medtronic, Inc. INFUSE Bone Graft, the PROGENIX Family of Grafts, and the MASTERGRAFT Family of Products are registered trademarks of Medtronic Sofamor Danek Inc. Spiralock is a registered trademark of Spiralock Corporation. Pomalux is a registered trademark of Westlake Plastics Co. Locator is a registered trademark of Zest Anchors, Inc. Delrin is a registered trademark of E.I. du Pont de Nemours and Company. LADDEC is a registered trademark of OST-Développement. LADDEC is manufactured by OST- Développement. MinerOss Cancellous and MinerOss Cortical are processed by DCI Donor Services Tissue Bank. Mem-Lok is manufactured by Collagen Matrix, Inc. Not all products shown or described in this literature are available in all countries. As applicable, BioHorizons products are cleared for sale in the European Union under the EU Medical Device Directive 93/42/EEC and the tissues and cells Directive 2004/23/EC. We are proud to be registered to ISO 13485:2003, the international quality management system standard for medical devices, which supports and maintains our product licences with Health Canada and in other markets around the globe. Original language is English. BioHorizons. All Rights Reserved. shop online at www.biohorizons.com