RUSKA PRODUCTS - PRICE LIST Effective Date: This price list is effective January 1, 2010 and supersedes all previous price lists for the items contained herein. NVLAP An optional ISO 17025 accredited calibration is available for all pressure products. The charge for an individual item is $150. Systems such as piston gauges are $150 per component, not to exceed a system total of $600. Warranty EPP Plan All products are supplied with a one year parts and labor warranty at no additional charge for servicing at our facility in Houston, Texas. We may authorize, on a case by case basis, warranty repair at one of our authorized services centers. An Extended Plus Plan is available for all products. The plan includes: Additional one year warranty (two years total) 10% discount on repairs in years 2 to 5 10% discount on recalibration charges for years 1 to 5 Automatic recalibration notice letter 10% discount on NVLAP accredited calibration fee 15% discount on Pressure Seminar EPP for all items is 8% of the list price value FOB All prices are FOB factory, Houston, Texas and do not include any applicable taxes. Carriage, insurance or freight (CIF) charges are not included in the prices herein. Minimum Order The minimum order amount is $100. Payment We accept company purchase orders on account approval in addition to MasterCard, VISA and American Express. Note that Houston site can only accept orders in USD. Status Please contact the Customer Service Department at ruska.pressurements@fluke.com for order status and shipment/tracking information. Prices effective January 1, 2010 Page 1 of 10 Rev. A
MODEL 2485 HYDRAULIC PISTON GAUGE 2485-801D Instrument Base rated to 20,000 psi (1000 bar) Instrument Base with rapid fill pump, motor drive and setup kit. Media: DOS. 2485-802D Instrument Base rated to 72,500 psi (5000 bar) Instrument Base with intensifier, motor drive and setup kit. DOS media only. 2485-940 Mass Set (100 kg) with trim masses and wooden storage cases. One required for every Model 2485 above. Select one or more piston/cylinders: PSI Increments 2485-981 10-1000 psi, (10 psi/kg) DOS 2485-982 100-10,000 psi (100 psi/kg) DOS 2485-983 200-20,000 psi (200 psi/kg) DOS 2485-989 1500-72,500 psi (725 psi/kg) DOS Bar Increments 2485-984 0.5-50 bar (0.5 bar/kg) DOS 2485-985 5-500 bar (5 bar/kg) DOS 2485-986 10-1000 bar (10 bar/kg) DOS 2485-989 75-5000 bar (50 bar/kg) DOS Model 2485 Accessories 2485-900-40600 Spare Parts Kit (DOS) 55-600 DOS Synthetic Oil (1 gallon) Multi Media Systems 2485-626-82900 Piston Gauge System, oil to gas System includes Model 2485LP Piston Gauge with mass set, low range and high range piston/cylinder, Model 2413 DPI Cell for oil to gas service and all components required for gas calibrations to 15,000 psi (1000 bar). NSN: 6685-01-276-7813 Recommended Accessories for the 2485-626-82900 include the 2456 Piston Gauge Monitor with 2455-2485 Adapter kit and 2456-LEM Laboratory Environment Monitor MODEL 2482 DIFFERENTIAL PRESSURE PRIMARY STANDARD 2482-801 Differential Pressure Primary Standard Oil and Gas Operation - requires PC with USB interface Prices effective January 1, 2010 Page 2 of 10 Rev. A
MODEL 2465 GAS PISTON GAUGE 2465 2465A-754 Autofloat Instrument Base with bell jar for gauge and absolute mode, with spare parts kit. 115/230 VAC selectable 2465A-799 Mass Set with Trim Masses Select one or more piston/cylinder(s): 2465-725 0.2-25 psi (14 mbar - 1.7 bar) 2465-727 1.7-100 psi (117 mbar - 7 bar) 2465-730 2-500 psi (140 mbar - 35 bar) 2465-729 2-1000 psi (140 mbar - 70 bar) 2465A-200 (115V) 2465A-201 (230V) 2456-LEM 2456-VAC Select Pressure Control Method: Autofloat Controller with WinPrompt32 software, barometric reference sensor and adapter kit. Specify if 115 or 230 VAC. Laboratory Environment Monitor (LEM) Vacuum Module 3990-801 Manual Pressure Control Pack, vacuum to 1000 psi 2465A-23 Lines and Fittings Kit Vacuum Pumps (optional*) 99878 Vacuum Pump with auto-vent, 85 liter/minute, 50/60 Hz Specify 115 or 230 VAC *Note: Autofloat system require vacuum pumps equipped with an auto-vent capability. *Note: Quantity 2 vacuum pumps are required for generating absolute mode pressures Computer (optional) Notebook PC with MS Windows and RS-232 interface Prices effective January 1, 2010 Page 3 of 10 Rev. A
MODEL 2468 PITOT STATIC PISTON GAUGE 2468 2465A-754 Autofloat Instrument Base with bell jar for gauge and absolute mode, with spare parts kit. 115/230VAC selectable. 2468A-799 Mass Set with trim masses Select one or more piston/cylinder(s): 2468-758 Standard range: 0.4-103 in.hg 2468-707 Optional mid range: 3.4-400 in.hg 2468-730 Optional high range: 4-2000 in.hg (2-1000 psi / 140 mbar - 70 bar) 2465A-200 (115V) 2465A-201 (230V) 2456-LEM 2456-VAC Select Pressure Control Method Autofloat Controller with WinPrompt32 software, barometric reference sensor and adapter kit. Specify if 115 or 230 VAC. Laboratory Environment Monitor (LEM) Vacuum Module 3990-801 Manual Pressure Control Pack, vacuum to 1000 psi (3990-801) 2465A-23 Lines and Fittings Kit 99878 Vacuum Pumps (optional*) Vacuum Pump with auto-vent, 85 liter/minute, 50/60 Hz Specify 115 or 230 VAC *Note: Autofloat system requires vacuum pumps equipped with an auto-vent capability. *Note: Quantity 2 vacuum pumps are required for generating absolute mode pressures Computer (optional) Notebook PC with MS Windows and RS-232 interface MODEL 2470 GAS PISTON GAUGE 2470 2470-703 Instrument Base for use with low, mid, and high range pistons 2470-736 Mass Set with Trim Masses Select one or more piston/cylinder(s): 2468-758 0.2-50 psi (13.5-3500 mbar) 2468-707 1.7-200 psi (115 mbar - 13.5 bar) 2470-730 100-3000 psi (6.89-201 bar) 3990-803 Manual Pressure Control Pack, to 3000 psi (207 bar) Prices effective January 1, 2010 Page 4 of 10 Rev. A
PISTON GAUGE ACCESSORIES 2456 Piston Gauge Monitor, Single channel, with RS-232 interface and WinPrompt software. 115/230 VAC, 50/60 Hz 2456D Select options and adapter kit(s) below: Model 2456 2456-LEM 2456-VAC Piston Gauge Monitor, Dual channel, with RS-232 interface (2) and WinPrompt software. 115/230 VAC, 50/60 Hz Laboratory Environment Monitor (2456-LEM) Vacuum Module (2456-VAC) Adapter Kits for 2456 2455-2485 Adapter Kit for Model 2485 2455-2400 Adapter Kit for Model 2400 2455-2450 Adapter Kit for Model 2450 / 2480 / 2481 2455-2465-754 Adapter Kit for Model 2465-754 and 2468 2455-2465-753 Adapter Kit for Model 2465-753 2455-2465-751 Adapter Kit for Model 2465-751 2455-11-006 RTD Only 2455-2470 Adapter Kit for Model 2470 2455-2475 Adapter Kit for Model 2475 2455-UNI-KIT Universal Adapter Kit (Not for use with DH/Budenberg 5000 Series) 2455-WINP32 WinPrompt software for stand alone applications 2455-WINP32-UPG WinPrompt Upgrade software (upgrades previous versions to 3.X) DP Cell and Null Indicator 2413-800 15,000 psi 2413-850 15,000 psi with bypass valve - liquid only common media 2413-851 3,000 psi with bypass valve - gas only 2417-800 40,000 psi 2416-711 Control Box Vacuum Pumps and Gauge 99700 Vacuum Gauge, monitor w/ NIST traceability, specify 115VAC or 230VAC 99878 Vacuum Pump with auto-vent, 85 liter/minute, 50/60 Hz Specify 115 or 230 VAC TRAINING Advanced Metrology Automated Controller Five Day course at factory Three Day course at factory For additional Training Options and Prices, contact the factory Prices effective January 1, 2010 Page 5 of 10 Rev. A
SERIES 7050 DIGITAL PRESSURE INDICATOR 7050 Digital Pressure Indicator with RS-232 and IEEE-488 interface, NIST traceable calibration, manual and power cord Gauge mode ranges: Select any full scale from 5 to 1500 psig (400 mbar to 100 barg) Permanent absolute* pressure ranges: Select any full scale from 15 to 50 psia (1 to 4 bara). * Includes on-board Vacuum Reference Option for zeroing 7050i Digital Pressure Indicator, with 0.005% of reading from 25% to 100% of range, with RS-232 and IEEE-488 interface, NIST traceable calibration, manual and power cord Gauge mode ranges: Select any full scale from 5 to 1500 psig (400 mbar to 100 barg) Permanent absolute* pressure ranges: Select any full scale from 15 to 50 psia (1 to 4 bara). * Includes on-board Vacuum Reference Option for zeroing 7050LP Low Pressure Digital Pressure Indicator, with RS-232 and IEEE interface, NIST traceable calibration, manual and power cord Select one of the following range combinations: 10 inh2o and 30 inh2o 20 inh2o and 60 inh2o 35 inh2o and 100 inh2o Series 7050 Vacuum (negative gauge) Mode Vacuum Reference (absolute mode thru vacuum pump) Barometric Reference (ranges 15 psi and higher) Includes Negative Gauge Option 3990-801 Manual Pressure Control Pack, vacuum to 1000 psi 3990-803 Manual Pressure Control Pack, to 3000 psi (207 bar) 781-016-A Intecal Advanced Software 7250-903 Rack mount kit for 19 in. EIA cabinets, 24 in. deep 7250-904 Rack mount kit for 19 in. EIA cabinets, 30 in. deep Prices effective January 1, 2010 Page 6 of 10 Rev. A
SERIES 7250 HIGH SPEED DIGITAL PRESSURE CONTROLLERS 7250xi High Speed Digital Pressure Controller, with RS-232 and IEEE-488 interface, NIST traceable calibration, manual and power cord Select any Full Scale pressure range from 20 to 2500 psig (1.6 to 172 barg) 7250i High Speed Digital Pressure Controller, with RS-232 and IEEE-488 interface, NIST traceable calibration, manual and power cord Gauge mode ranges: Select any Full Scale pressure range from 5 to 2500 psig (400 mbar to 172 barg) Permanent absolute* pressure ranges: Select any Full Scale pressure range from 15 to 50 psia (1 to 4 bara) 7250 High Speed Digital Pressure Controller, with RS-232 and IEEE-488 interface, NIST traceable calibration, manual and power cord Gauge mode ranges: Select any Full Scale pressure range from 5 to 2500 psig (400 mbar to 172 barg) High pressure range: 3000 psia Permanent absolute* pressure ranges: Select any Full Scale pressure range from 15 to 50 psia (1 to 4 bara) * Includes on-board Vacuum Reference Option for zeroing 7250LP High Speed Digital Pressure Controller, with RS-232 and IEEE-488 interface, NIST traceable calibration, manual and power cord Select one of the following range combinations: 10 inh2o and 30 inh2o 20 inh2o and 60 inh2o 35 inh2o and 100 inh2o Prices effective January 1, 2010 Page 7 of 10 Rev. A
SERIES 7252 DUAL OUTPUT HIGH SPEED DIGITAL PRESSURE 7252i Dual Output / Dual Channel High Speed Digital Pressure Controller, with RS-232 and IEEE-488 interface, NIST traceable calibration, manual and power cord Select any two of the following ranges: Select two of any Full Scale pressure range from 5 to 2500 psig (400 mbar to 172 barg), or permanent absolute range from 15 to 50 psia (1 to 4 bara) **. Low Pressure (LP) ranges starting at 10 inh2o (25 mbarg) are also available (7252i only). 7252 Dual Output / Dual Channel High Speed Digital Pressure Controller, with RS-232 and IEEE-488 interface, NIST traceable calibration, manual and power cord Select any two of the following ranges: Select two of any Full Scale pressure range from 5 to 2500 psig (400 mbar to 172 bar). Or, any permanent absolute range from 15 to 50 psia (1 to 4 bara). ** ** Note: Permanent absolute range requires Vacuum Reference Option (see below) for zeroing in absolute mode. One required for each absolute range. Series 7250/7252 Vacuum Reference (absolute thru vacuum pump) N/A with 7250xi Barometric Reference for absolute mode and vacuum mode operation (N/A for 3000 psia range or ranges 15 psig and below) - Includes Negative Gauge Option Negative Gauge Mode Triple scale option for 3000 psia 7250 7250-903 Rack mount kit for 19 in. EIA cabinets, 24 in. deep 7250-904 Rack mount kit for 19 in. EIA cabinets, 30 in. deep 7000-110 Lines and Fittings Kit (7250) 99878 Vacuum Pump, 85 L/M, Specify 115 VAC or 230 VAC 7000-102 Liquid Trap assembly, 3000 psi / 210 bar 781-016-A Intecal Advanced Software 7000-METDRV MET/CAL Driver (7250xi, 7250i, 7250, 7250LP, 7215) Prices effective January 1, 2010 Page 8 of 10 Rev. A
SERIES 7250SYS PRESSURE CALIBRATION SYSTEMS 7250SYS Each system includes one vacuum pump and the Barometric Reference Option to allow measurement and control in negative gauge and absolute mode. 8 Range System to 1000 psi 8 Range System to 2500 psi 12 Range System to 2500 psi 7250Sys 7000-METDRV Gas Booster (NOT CE CERTIFIED) Vacuum Reference Option with second Vacuum Pump* DUT Absolute Zeroing MET/CAL Driver *when selected with the Gas Booster, the booster will be placed outside of cabinet with 2 pumps inside Intecal Software 781-016-A Intecal Software Intecal Advanced Software for Windows MODEL 7350 HIGH PRESSURE PNEUMATIC DIGITAL PRESSURE 7350 High Pressure Pneumatic Pressure Controller with RS- 232 and IEEE-488 interface, NIST traceable calibration, manual and power cord PSI pressure ranges: 6000 or 10,000 psia Bar ranges: 415, 700 bar a Note: Specify line voltage, 115 or 230 VAC Model 7350 Triple scale option 7350-105 Lines and Fittings Kit 781-016-A Intecal Advanced Software 7000-METDRV MET/CAL Driver Prices effective January 1, 2010 Page 9 of 10 Rev. A
MODEL 7615 HIGH SPEED HYDRAULIC DIGITAL PRESSURE CONTROLLER 7615 High Speed Hydraulic Controller with RS-232 and IEEE- 488 interface, NIST traceable calibration and manual PSI Ranges: 6000, 10,000, 15,000, 20,000 psia PSI Ranges: 30,000 and 40,000 psi Bar Ranges: 415, 700, 1035, 1400 bar a Bar Ranges: 2070 and 2750 bar a Specify media at order placement 55-503 Silicone Dow 200 (1 gallon) 55-600 DOS Synthetic Oil (1 gallon) [Recommended] 55-525 Deionized Water (1 gallon) 55-537 Silicon Oil, DOW 510R (1 gallon) 55-526 Fluorinert FC-77 (0.75 gallon, boiling temperature 97 C) 55-527 Fluorinert FC-70 (0.75 gallon, boiling temperature 215 C), 20 ksi max. Note - Fluorinert can be used to 20,000 psi (1400 bar) max. MODEL 7615 OPTIONS Triple scale option Dual Sensor Triple scale option for Dual Sensor (six range) 7615C-800-40800 7615 Spare Parts Kit 7615-EXV External priming vent valve 7615-106 7615 Rack mount for up to 26 in deep cabinets 781-016-A Intecal Advanced Software 7000-METDRV MET/CAL Driver MODEL 7750i AIR DATA TEST SET 7750i Laboratory Air Data Test Set, with IEEE-488 interface, NIST traceable calibration, manual, power cord Standard Ranges: Ps: 100inHg Abs Qc: 68inHg Diff Ps: 32inHg Abs Qc: 68inHg Diff Ps: 40inHg Abs Qc: 68inHg Diff Ps: 32inHg Abs Qc: 32inHg Diff Ps: 40inHg Abs Qc: 32inHg Diff Model 7750 Accessories 99878 Vacuum Pump, 85 L/M Specify 115 VAC or 230 VAC 7750-104 Lines and Fittings Kit 7250-903 Rack Mount Kit Prices effective January 1, 2010 Page 10 of 10 Rev. A