Fieldbus Tools Hand-Held Configuration Devices Mobility DHH810-MFT Modular Calibrator with HART Communications
|
|
|
- Lauren Barber
- 10 years ago
- Views:
Transcription
1 Data Sheet Fieldbus Tools Hand-Held Configuration Devices Mobility DHH810-MFT Modular Calibrator with HART Communications Hand-Held Terminal - for device calibration and for HART device configuration, commissioning, and maintenance operations. Supported Devices - ABB instruments and third party suppliers Supported HART Commands - Universal, Common Practice, and Device Specific. User Interface (6.6cm) x 2.6 (6.6cm) display, four soft keys (definitions change with mode requirements) and eight hard keys for user interaction. Display is configurable for 1 to 4 simultaneous measurements. Sensor Modules select from a variety of positivelock measurement modules for excellent versatility. All modules can be hot swapped remove or install sensor modules while under power except in Intrinsically Safe areas. Field Recertification sensor modules and integral V / I can be recalibrated for zero, span, & linearity through the base unit. Measurement Units customary English and Metric System units are selectable User Convenience Auto shut off, Damping, Min/Max value capture, display Hold, sensor Zero and direct Contrast adjustment Security Lockout Mobility DHH810-MFT settings can be locked out entirely or by specific feature. Diagnostics Mobility DHH810-MFT self-tests upon power up and upon installation of sensor modules. Advisories are posted on the display. On-Site Updates uses Internet downloads to update and add capability / HART support Extensive Memory Memory for 600 HART device profiles. All-in-One Tool takes the place of multiple hand-held instruments, simplifies workload and improves productivity. DHH810-MFT
2 Mobility DHH810-MFT Modular Calibrator with HART Communications As part of ABB s Mobility line of device hand-helds, the Mobility DHH810-MFT Calibrator is a hand-held terminal for device calibration and configuration of HART instruments. It interfaces to a wide range of devices supporting ABB instruments as well as those from third party suppliers. Users can view up to four measurements simultaneously on the high resolution LCD or compare HART PV and AO values to corresponding values measured by the NIST traceable Mobility DHH810-MFT. Available sensor modules include a variety of differential, gauge, vacuum and absolute pressure as well as RTD and thermocouple temperature units at varying ranges. A voltage and current meter is integral to the base unit. All HART field devices can be configured, polled, and trimmed using HART communications. Device Specific commands for supported devices are included with the Mobility DHH810-MFT. The Mobility DHH810-MFT is designed for optimum convenience and usability. It s ergonomic design makes the Mobility DHH810-MFT easy for field carrying and use. Design Features USER INTERFACE 2.6 (6.6cm) x 2.6 (6.6 cm) display, four soft keys (definitions change with mode requirements) and eight hard keys for user interaction. Display is configurable for 1 to 4 simultaneous measurements. SENSOR MODULES select from a variety of positivelock measurement modules for excellent versatility. All modules can be hot swapped remove or install sensor modules while under power except in Intrinsically Safe areas. FIELD RECERTIFICATION sensor modules and integral V / I can be recalibrated for zero, span, & linearity through the base unit. MEASUREMENT UNITS customary English and Metric System units are selectable USER CONVENIENCE Auto shut off, Damping, Min/Max value capture, display Hold, sensor Zero and direct Contrast adjustment SECURITY LOCKOUT Mobility DHH810-MFT settings can be locked out entirely or by specific feature DIAGNOSTICS Mobility DHH810-MFT self-tests upon power up and upon installation of sensor modules. Advisories are posted on the display. FIELD UPDATES uses Internet downloads to update and add capability / HART support EXTENSIVE MEMORY Memory for 600 HART device profiles. ALL-IN-ONE TOOL takes the place of multiple hand-held instruments, simplifies workload and improves productivity The Mobility DHH810-MFT includes a Base unit with 3 bays for housing sensor modules and supports Device Specific HART communications. Quick Cal displays HART PV and AO along with DHH810-MFT s NIST traceable measurements. Users can identify needed trim(s) and access the trim function(s) from the same display. Smart Trim allows selection of analog or digital trims without navigating through menu trees. Users can add a Voltage/MilliAmp (VMA) sensor module (part number 3KXD311810L0070) to temporarily power the transmitter loop. Documenting memory and firmware are included with every Mobility DHH810-MFT for use with Mobility DHH820-DMS software. The Mobility DHH810-MFT Calibrator stores up to 200 HART configuration files and over 100 calibration results (as-found & as-left data [up to 21 points each], time/date info, tag). It communicates with the PC hosting DHH820-DMS via a DB-9 connector. USB to DB-9 pin adapters are available. Specifications Base Unit: Length = Width = Depth = Housing = 9.00" (22.86 cm) 4.70 (11.94 cm) 3.58 (9.09 cm) ABS plastic case with shock absorbing boot Weight = 28 ozs (794 g) Modularity = Three bays for measurement modules Display: 128 x 128 pixel graphic display, 2.6 (6.6 cm) x 2.6 (6.6 cm) viewable area, 5-digit resolution Power: 6 AA alkaline or NiMH batteries optional Vac power adapter Temperature: Storage:-40º F to 140º F (-40º C to 60º C) Operating: 23º F to 122º F (-5º C to 50º C) 2
3 Connections:Pressure: 1/8 ( cm) FNPT, 316ss Electrical Std. banana jacks (¾ (1.9 cm) center-to-center) for ±50 ma/ Volts, HART & Loop leads Data transfer: DB-9 for RS-232C Intrinsically Safe Option: Class I, Div I areas per CSA 22.2 & UL 913 by MET Laboratories Certification to ATEX pending. NIST Traceable Accuracy: Pressure: ± 0.025% to ± 0.10% of Full Scale including all effects of linearity, repeatability, hysteresis and temperature over the range of 23 F to 122 F (-5 C to 50 C). Current / Voltage: ± 0.025% of Full Scale ± 0.001% of Span per F (ref. temp. 70 F) ± % of Span per C (ref. temp. 21 C) Pressure Module Limits/Medias: GI / AI sensor modules (part numbers 3KXD311810L0020 through 3KXD311810L0042): 2X range / 316ss compatible DN sensor modules: (part numbers 3KXD311810L0001 through 3KXD311810L0006): 2X range when pressurized on high side only, 150 PSI (10.3 bar) when applied simultaneously to high and low sides / dry gases only Sensors Modules: 2.3 (5.84 cm) L x 1.3 (3.3 cm) W x 2.6 (6.6 cm) D, 8.3 oz (235 g) or less. Positive-lock with spring latch. Depress latch to release. Electrical connections are PC board contacts to spring loaded. Electrical Compliance:All units CE marked Use Cases The Mobility DHH810-MFT supports a wide range of functions that can help to reduce costs by saving time in start-up, day-to-day operations, and maintenance activities. It powers up quickly, typically in less than 2-3 seconds, and it easily connects with device terminals and/or wiring, making it readily available to begin configuration, calibration and/or troubleshooting. The locking calibration sensor modules are easy to install and remove, even with power applied, and are readily connected to optional pressure or voltage sources for generating calibration signal inputs. Up to 3 sensor modules can be installed in the Mobility DHH810- MFT at the same time, allowing different device types or ranges to be calibrated without having to swap out modules. The VMA sensor module (Part Number 3KXD311810L0070) can be inserted in 1 of the 3 available bays and used as a portable 24V power source in situations where external power is unavailable. On power-up the Mobility DHH810-MFT searches for a connected device, and upon finding it, the DHH810-MFT display identifies the device and reveals a wealth of information about the device in its large 6.75 sq. inch (17.15 cm 2 )display area including the primary measurements for each of the installed sensor modules. The large 200-device configuration and 100-device calibration results memory capacity allows the Mobility DHH810- MFT to be used in the field for long periods of time without having to upload it s saved data. Below are some of the typical ways that the Mobility DHH810-MFT can be used. Commission devices Step-by-step configuration Document as-left configuration Electronic Birth Certificate Step-by-step calibration Operations Reconfiguration for process changes Reconfiguration for batch runs Document as-found and as-left configurations Populate DHH820-DMS database software Device Maintenance Troubleshoot devices with HART View device error messages Clone devices to commission replacements Preventive review of device status Technician Approval documents actions The Mobility DHH810-MFT provides HART users with a useful, reliable, and calibration tool. Combine it with our Mobility DHH800-MFC Communicator and Mobility Device Management System (DHH820-DMS) documenting software to provide the only single-source device management solution capable of meeting continually changing documentation requirements. 3
4 Device Management System (DHH820-DMS) Software Data Management, Calibration and Maintenance The Mobility Device Management System (DHH820- DMS) software is used with ABB s Mobility line (DHH810-MFT) of device hand-helds for managing device configuration, calibration procedures, and device documentation. It interfaces to the Mobility hand-held (DHH810-MFT) via a DB-9 serial port connector. USB to DB-9 pin adapters are available. Device Management System (DHH820-DMS) Software: The Mobility Device Management System (DHH-820- DMS) software uses Microsoft SQL Server to support record keeping and retrieval of information. Some of the functions included with DHH820-DMS are listed below. Graphic User Interface The DHH820-DMS has an easy to use, Windows Explorer-like interface for quick navigation and organization of device data. Data Server Powerful Microsoft SQL data server provides a robust platform for data storage and management. This widely used database platform enables connectivity to other plant solutions. Associated Documents Provides links to relevant documents such as technical specifications, calibration certificates, standard operating procedures, and CAD documents. When selected, the documents open in their native application. Activity Logging Logging of activities related to a device such as alerts, configuration, calibration or other actions that impact a device. Reporting/Queries Standard reports, such as calibration certificates, activity logs, and scheduled activities. The user can generate custom queries that can be printed or exported for use in other applications. Import/Export Utilities Data can be imported via DHH820-DMS generated templates for the initial population of the DHH820-DMS database and for exchanging data with other applications. Calibration Procedures Calibration procedure details, such as methods for error calculation, number of test points, transposition equations, and pass/fail criteria can be developed and applied to devices individually or in groups. These procedures are maintained in a library for future use and editing. Integrated Solution DHH820-DMS is tightly integrated within other ABB software applications including System 800xA. This expands on DHH820-DMS standard functionality to allow it to participate in an Asset Optimization solution including online connection to HART devices via HART Multiplexers for asset condition monitoring and notification. Documenting Process Calibrator (DPC): The Mobility DHH810-MFT includes documentation capabilities that enable it to interface with DHH820-DMS and to perform as a Documenting Process Calibrator Documenting Calibration and Configuration Data The DPC reads and stores calibration test points, calibration results (As-Left/As-Found), configuration parameters and calibration reference standard information. Upload/Download Functions Calibration Schedules (Action Lists) are generated by DHH820-DMS and downloaded to the DPC for processing. Once the activities of the action list are completed and documented by the DPC, the information is uploaded from the DPC to the DHH820-DMS database. DHH820-DMS tracks both work-in-progress and planned calibration and configuration activities. Communicator/Calibrator & Sensor Module Registration The DHH810-MFT and sensor modules are registered with the DHH820-DMS. Every action performed is associated with the unique ID of the DHH810-MFT and related sensor modules. The DHH820-DMS tracks DHH810-MFT sensor modules (internal, external, removable) to support the traceability and auditing functions of the DHH820-DMS. Scheduling/Planning Calibration due dates can be assigned to devices, optimizing productivity through planning of calibration activities. Due dates can be assigned according to quality control, Safety Instrumented System ratings, or any other critical requirements. User definable pre-notices can be applied to alert users. 4
5 Action Lists An Action List is the tool that DHH820-DMS uses to group multiple activities, which can be assigned to calibration and maintenance technicians. The Action List is downloaded to the DHH810-MFT and acts as a To-Do List of activities. The Action List activities are tracked by DHH820-DMS to ensure completion of assigned activities and prevent redundancy. Use Cases DHH820-DMS supports two main use cases - calibration and maintenance, and commissioning. A variety of functions as described below are provided within these use cases. Calibration And Maintenance Alerts/Alarms Criticality settings based on, for instance, Safety Integrity Levels (SIL) can be assigned to a device. Other acceptance criteria can be established and assigned to a device. These settings are checked and used to notify administrators when acceptance criteria are not met. Devices under alarm or alert are listed in a separate folder for easy access and disposition. MFT Upload/Download of Action Lists A key component in any calibration management solution is a documenting process calibrator. Action Lists that are downloaded to the DHH810-MFT contain all the information necessary to perform activities on a device. The Action List serves as the itinerary for the maintenance technician and includes all relative calibration and/or configuration instructions. The progress and results of these activities are recorded and uploaded to the DHH820-DMS so that the DHH820-DMS maintains the latest activities performed on any device. Device Activity Log Any activity that impacts a device is electronically stamped with date, time, user, and description of activity, user ID and notes. Each device has its own log of associated activities. Version Manager A Version Manager maintains versions of the DPC firmware, DHH820-DMS software, calibration sensor module calibration dates, and Device Object Files (DOF s). This tool provides notices to the user regarding updates and provides a means for auditing and traceability for calibration standards. Preventive Maintenance Utilization of the Action Lists and Scheduling features enable the development of a preventive maintenance plan based on manufacturers recommended calibration cycles, plant standard practices, or historical activity for a device. Commissioning Device Specific Cloning New devices can be configured and installed by copying similar existing devices. The user can clone the device information from multiple sources; an off the shelf device, the DHH820-DMS database, or the DHH820-DMS library of standard devices. System Cloning Copying of device information can be performed on a system basis as well. A system can be copied and used as a baseline for developing a similar system for a new division. Device Set-Up/Configuration Commissioning of new devices can be accomplished by assigning the activity to an Action List for download to an DHH810-MFT. Upgradeability via Download Site A download website enables users to update DHH820- DMS software service packs, and DOF Library additions. A subscription to the download site is standard. Industry Standard Compliance DHH820-DMS is built for use in an open system environment. FCINTF Specification Support DHH820-DMS uses ISA s FCINT interface specification for upload/download communication with Documenting Process Calibrators (DPC s). Many of the popular DPC s on the market support the ISA FCINTF specification. Non-Proprietary The DHH820-DMS and DHH810-MFT utilize a Device Object File (DOF) to communicate with specific smart devices. Although the DOF s technology is protected, full access to the technology is available through the DHH820-DMS and DHH810-MFT open interface architecture. Plant Application Compatibility The DHH820-DMS application was developed using SQL server database, which has features that enable it to support ODBC data exchange and functionality with other plant applications. The DHH820-DMS has export/ import capabilities to support manual data exchange including features to map data between other popular device databases. 5
6 Ordering information Variant digit No Mobility DHH810-MFT Modular Calibrator Catalog No. DHH810- Mobility DHH810-MFT Modular Calibrator with HART Communications MFT - Includes CE Mark, Test Lead Kit, RS-232 Serial Cable, Paper User's Manual, NIST Traceability Certificate standard for modules & base unit, and 3-year download subscription Model Type Calibration and Configuration - All Supported HART devices 1 2 (ABB and non-abb) Calibration Only - HART and Conventional devices 2 2 Documenting Options Standard 1 - As-found & as-left function requires DHH820-DMS database software sold separately Certification CE Mark (Standard on all units) 0 0 CE Mark, Intrinsic Safety certification by MET Laboratories per CSA 0 1 C22.2 No , C22.2 No. 157, and UL913, Fifth Edition Rev. 2/21/97 for Class I, Div I, Groups A, B, C & D Carrying Case and Strap Options Rear Hand Strap with protective boot (Standard on all units) 0 Rear Hand Strap with protective boot and Fitted Use in Place Soft Carrying Case 1 Rear Hand Strap with protective boot and MFT Hanging/Shoulder Strap 2 User's Manual Language English 0 1 Reserved Always one 1 Firmware Language English 0 1 Note: Selection of the DHH810-MFT12 model is required for configuration of HART devices and calibration of HART and conventional 4-20mA devices while selection of the DHH810-MFT22 model provides support only for calibration of HART and conventional 4-20 ma devices. The upgrade from DHH810-MFT22 to DHH810-MFT12 does not require the return of the hand-held and can be done via keypad entry after purchase of the upgrade with part number 3KXD311810L0300. CF = Consult Factory Standards Products = 6
7 Additional ordering information Mobility DHH810-MFT Modular Calibrator - Accessories Note Catalog No. Sensor Modules Modules are Intrinsically Safe when used in accordance with Control Document NIST Traceability Certificate standard for all modules. 1-10" H20 dp ( mbar), ± 0.1% Full Scale (FDN ) 3KXD311810L0001 from 23 F (-5 C) to 122 F (50 C) (± H20 dp (± mbar)) 0-20" H20 dp (0-50 mbar), ± 0.1% Full Scale (FDN ) 3KXD311810L0002 from 23 F (-5 C) to 122 F (50 C) (± 0.02 H20 dp (± mbar)) 0-100" H20 dp (0-250 mbar), ± 0.025% Full Scale (DDN ) 3KXD311810L0003 from 23 F (-5 C) to 122 F (50 C) (± H20 dp (± mbar)) 0-200" H20 dp (0-500 mbar), ± 0.025% Full Scale (DDN ) 3KXD311810L0004 from 23 F (-5 C) to 122 F (50 C) (± 0.05 H20 dp (± mbar)) 0-400" H20 dp (0-1 bar), ± 0.025% Full Scale (DDN ) 3KXD311810L0005 from 23 F (-5 C) to 122 F (50 C) (± 0.10 H20 dp (± 0.25 mbar)) " H20 dp (0-5 bar), ± 0.025% Full Scale (DDN ) 3KXD311810L0006 from 23 F (-5 C) to 122 F (50 C) (± 0.50 H20 dp (± 1.25 mbar)) 0-20 PSIG ( bar), ± 0.025% Full Scale (DGI ) 3KXD311810L0020 from 23 F (-5 C) to 122 F (50 C) (± PSIG (± 0.35 mbar)) PSIG ( bar), ± 0.025% Full Scale (DGI ) 3KXD311810L0021 from 23 F (-5 C) to 122 F (50 C) (± 0.05 PSIG (± 3.5 mbar)) PSIG ( bar), ± 0.025% Full Scale (DGI ) 3KXD311810L0022 from 23 F (-5 C) to 122 F (50 C) (± PSIG (± 8.6 mbar)) PSIG ( bar), ± 0.025% Full Scale (DGI ) 3KXD311810L0023 from 23 F (-5 C) to 122 F (50 C) (± 0.25 PSIG (± 17.2 mbar)) PSIG ( bar), ± 0.025% Full Scale (DGI ) 3KXD311810L0024 from 23 F (-5 C) to 122 F (50 C) (± PSIG (± 25.9 mbar)) PSIG ( bar), ± 0.025% Full Scale (DGI ) 3KXD311810L0025 from 23 F (-5 C) to 122 F (50 C) (± PSIG (± 34.5 mbar)) PSIG ( bar), ± 0.025% Full Scale (GGI ) 3KXD311810L0026 from 23 F (-5 C) to 122 F (50 C) (± 1.50 PSIG (± mbar)) mm Hg ( mbar), ± 0.025% Full Scale (DAI ) 3KXD311810L0040 from 23 F (-5 C) to 122 F (50 C) (± mm Hg (±.30 mbar)) mm Hg ( mbar), ± 0.025% Full Scale (DAI ) 3KXD311810L0041 from 23 F (-5 C) to 122 F (50 C) (± 0.50 mm Hg Abs (± 0.67 mbar)) mm Hg ( mbar), ± 0.025% Full Scale (DAI ) 3KXD311810L0042 from 23 F (-5 C) to 122 F (50 C) (± mm Hg Abs (± 17.5 mbar)) T/C measure and simulate module supports (TIO ) 3KXD311810L0060 types B,C,E,J,K,N,R,S,T,M,P. Recommend TIO Starter Kit (P/N 3KXD311810L0100) RTD measure and simulate module (RIO ) 3KXD311810L0065 supports 22 different RTDs. Requires Special Module Connectors from RIO Starter Kit (P/N 3KXD311810L0102) V/I: meas ±55 Vdc, source 0-28Vdc; (VMA ) 3KXD311810L0070 ma: meas ±100 ma dc, source ma dc. Recommend VMA Starter Kit (P/N 3KXD311810L0101) Standards Products = Starter Kits for Various Sensor Modules TIO Starter Kit for P/N 3KXD311810L0060 (A37062) 3KXD311810L0100 module t/c meas. & sim. - Universal includes: P/N 3KXD311810L0243 t/c wire Kit 1 for E, J, K, N, T; mini-t/c conn., 1 m cable P/N 3KXD311810L0244 t/c wire Kit 1 for B, K, R/S; mini-t/c conn., 1 m cable P/N 3KXD311810L0245 mv measure / sim. cable assembly; mini-t/c conn. VMA Starter Kit for P/N 3KXD311810L0070 (A ) 3KXD311810L0101 module V / I meas. & sim. - Universal includes: P/N 3KXD311810L0203 VMA test lead kit, banana plugs on 9" breakouts both ends, assorted connectors RIO Starter Kit for P/N 3KXD311810L0065 (A37063) 3KXD311810L0102 module RTD meas. & sim. - Universal includes: P/N 3KXD311810L0242 Measure cable; module connector by four (4) alligator clips P/N 3KXD311810L0241 RTD mating connector (for use with customer's RTD) P/N 3KXD311810L0246 Simulate cable; module connector by two (2) alligator clips 7
8 Additional ordering information Mobility DHH810-MFT Modular Calibrator - Accessories Catalog No. Kit Options Standard kit includes: hard carrying case (P/N 3KXD311810L0141), pressure (P/N 3KXD311810L0160) or vacuum (P/N 3KXD311810L0161) pump, low pressure connection kit (P/N 3KXD311810L0180). Standard kit with P/N 3KXD311810L0160 (A36785) 3KXD311810L0120 pressure pump Standard kit with P/N 3KXD311810L0161 (A36786) 3KXD311810L0121 vacuum pump Carrying Case / Hanging Strap Soft case w/ shoulder strap for carrying one MFT (A36749) 3KXD311810L0140 and installed modules, additional modules, test lead kit, hand pump & fittings. ABS plastic carrying case with handle (A36750) 3KXD311810L0141 and foam insert for MFT base unit and installed modules, additional modules, test lead kit, hand pump, RTD temperature probe, fittings & tubing. MFT Hanging/Shoulder Strap, includes factory (A36936) 3KXD311810L0142 mounted D-Rings to MFT case, adjustable strap, spring-loaded swivel snaps. Pressure Sources 961P pressure pump with integral variator, (B34686) 3KXD311810L0160 bleed valve, 1/8" ( cm) Female NPT connection, PSIG (0-10 bar) 961V vacuum pump with integral variator, (B34700) 3KXD311810L0161 bleed valve, 1/8" ( cm) Female NPT connection, -650 mm Hg (-867 mbar) PV211 Pressure/Vacuum Pump in Hard Carrying Case. (A37118) 3KXD311810L0162 Pump has integral variator, bleed valve, 1/4" ( cm) Female NPT adpater, PSI (41.4 bar) inhg, hose included. IAS-AIII service kit For PV211 pump; (A37119) 3KXD311810L0163 P/N 3KXD311810L0162 above. Fittings Kit; Quick Fit x 1/8 NPTF, x 1/4NPTF, (A37114) 3KXD311810L0164 x 3/8 NPTF, x 1/2 NPTF, x 1/8 NPTM, x 1/4NPTM Repair parts kit for pressure pump 3KXD311810L0160 (961P (A ) 3KXD311810L0165 Repair parts kit for vacuum pump 3KXD311810L0161 (A ) 3KXD311810L0166 Fitting Kits & Accessories Low Pressure Connector Kit (A34386) 3KXD311810L0180 (not for use above 250 PSIG (17.3 bar)) includes: 1/8" ( cm) OD tubing length 18 ft (5.49 m), 1/8" ( cm) OD "T" fittings (2), 1/8" ( cm) OD tube by 1/8" ( cm) Male NPT adapters (6) + 3/16" ( cm) barb to 1/8" ( cm) Female NPT (1) fitting and 1/4" (0.635 cm) Male NPT to 1/8" ( cm) Female NPT reducers (2) 1/8" ( cm) O.D. tubing to 1/8" ( cm) Male NPT (A34102) 3KXD311810L0181 (not for use above 250 PSIG (17.3 bar)) 1/8" ( cm) O.D. tubing union tee (A34112) 3KXD311810L0182 (not for use above 250 PSIG (17.3 bar)) 1/4" (0.625) Male NPT X 1/8" (0.3175) Female NPT (A ) 3KXD311810L0183 reducer bushing, brass 10 ft (3.05 m) of 1/8" ( cm) O.D. nylon tubing (A ) 3KXD311810L0184 (not for use above 250 PSIG (17.3 bar)) Push to read equalizing manifold (A36853) 3KXD311810L0185 for DP modules, brass, 1/8" ( cm) Female NPT connections High Pressure Connection Kit (A ) 3KXD311810L0186 (not for use above 9,000 PSIG (620.5 bar)) includes: 3' (0.91 m) HP Hose with 1pc 1/8" ( cm) Male NPT & 1 pc 1/4" (0.635 cm) Male NPT x HP Quick Connect fitting High Pressure Connection Kit (A ) 3KXD311810L0187 (not for use above 9,000 PSIG (620.5 bar)) includes: 1' (0.30 m) HP Hose with 1pc 1/8" ( cm) Male NPT and 1pc 1/4" (0.635 cm) Male NPT x HP Quick Connect fitting 5 pcs 1/4" (0.635) MNPT x HP Quick Connect Fitting (A ) 3KXD311810L0188 (not for use above 9,000 PSIG (620.5 bar)) includes: 1 pcs 1/8" ( cm ) Male NPT HP Quick Connect fitting (A ) 3KXD311810L0189 (not for use above 9,000 PSIG (620.5 bar)) includes: Standard Products = 8
9 Additional ordering information Mobility DHH810-MFT Modular Calibrator - Accessories Note Catalog No. Electrical / Communications and Power Accessories HART Test Lead Kit - std banana plugs, mini-grabbers, (A ) 1) 3KXD311800L ohm resistor Standard Test Lead Kit (A ) 3KXD311810L standard banana plugs with assorted connectors Standard size 250 ohm shunt resistor (A36821) 3KXD311800L0012 required for HART low resistance loops VMA Test Lead Kit (A ) 3KXD311810L banana plugs on 9" (22.9 cm) breakouts both ends, assorted connectors Adapter, standard banana jack (F) (A ) 3KXD311810L0204 to mini-banana jack (M) DB-9 cable, Male x Female, 6 ft (1.82 m) length (A ) 1) 3KXD311800L pack of AA Alkaline Batteries (A ) 1) 3KXD311810L pack of AA 1.2V NiMH Batteries (A ) 3KXD311810L0221 NiMH battery charger, (A37134) 3KXD311800L0031 holds up to 8 individual AA cells, 8 hours, 120 VAC 60 Hz Power adapter, with pin connector (A37160) 1) 3KXD311800L Vac to 240 Vac, Hz Universal plug adapter kit for P/N 3KXD311800L0034 (A37159) 1) 3KXD311800L0035 power adapter Power adapter with barrel connector (9B000007) 3KXD311800L Vac, Hz and Universal plug adapter 24Vdc Power Supply, (A ) 3KXD311810L0225 input: 120Vac 60 Hz, output: 24Vdc 350 ma Temperature Accessories Pt 100 RTD, DIN Class "A", alpha, 3KXD311810L lead, 1/4" (0.635 cm) O.D. 300 Series SS probe, 10" (25.4 cm) length, 3.5" (8.9 cm) handle and 5 ft ((1.52 m) coiled cable with connector for RIO temperature module, P/N 3KXD311810L0065 Mating connector for RTD temperature modules (A ) 3KXD311810L0241 facilitates use of customer's RTD User cable for RTD temp module, (A ) 3KXD311810L ft (1.52 m) cable, 4 lead wires, alligator clip terminations T/C wire Kit 1 for types E, J, K, N, T; (A36857) 3KXD311810L0243 mini t/c connector, 1 m cable T/C wire Kit 2 for types B, K, R/S; (A36858) 3KXD311810L0244 mini t/c connector, 1 m cable mv measure/simulate cable assembly; (A36881) 3KXD311810L0245 mini t/c connector, 3.5 ft. (1.07 m) copper cable, alligator clips Simulate cable for RTD temp module, (A ) 3KXD311810L ft (1.52 m) cable, 2 lead wires, alligator clip terminations Open Bay Protection Module Dummy module protects unused (open) (A36741) 1) 3KXD311810L0260 sensor module bays in MFT Media and Manuals Mobility Interface Software CD set, latest version (698B277U01) 1) 3KXD311800L0041 Mobility MFT Operations Manual, printed hard copy (694A199U01) 1) 3KXD311810R one copy supplied with order at no charge and pdf instructions included on CD Upgrade from DHH810-MFT22 to DHH810-MFT12 (DPCHRTUPG-01) 3KXD311810L0300 DPC Manager for Configuration Management (DPCMAN-CFG) 3KXD311820L0001 DPC Manager for Configuration Management (DPCMAN-CAL) 3KXD311820L0002 DPC Manager for Configuration and Calibration Management (DPCMAN-AAL) 3KXD311820L0003 Upgrade DPC Manager to Configuration and Calibration Management(DPCMAN-ALL-UPGRD 3KXD311820L Year Download Subscription for 1 DPC unit 3KXD311800L Year Download Subscription for 2 to 4 DPC units 3KXD311800L Year Download Subscription for 5 to 9 DPC units 3KXD311800L Year Download Subscription for 10 to 19 DPC units 3KXD311800L Year Download Subscription for 20 or more DPC units 3KXD311800L0055 Note 1) Included with base order DHH810-MFT Standard Products = 9
10 Ordering information Device Management System (DMS) Software Variant digit No DHH820-DMS Catalog No. DHH820- Mobility Device Management System Software DMS Device Management System (DMS) Software, DMS Server and Integral Client, 1 Year Software Maintenance plus Documenting Process Calibrator / Communicator (DPC) Interface to DMS included. This feature enables users to electronically exchange calibration procedure and /or HART Device configuration data with DMS software through a RS-232 Serial Interface. Type 1) DMS Server with DPC interface (Calibration and Configuration) 2) 1 DMS Server with DPC interface (Configuration only) 2) 2 No. of DMS Clients No 3) 0 1 Client integral to DMS Server (Calibration and Configuration) 4) 1 5 Clients (Calibration and Configuration) 4) 2 10 Clients (Calibration and Configuration) 4) 3 1 Client integral to DMS Server (Configuration Only) 5) 4 5 Clients (Configuration Only) 5) 5 10 Clients (Configuration Only) 5) 6 Add 21 CFR 11 Support No 0 Expand Existing DHH820-DMS New Initial Purchase 0 Expand from 1 to 5 clients (Calibration and Configuration) 6) 1 Expand from 5 to 10 clients (Calibration and Configuration) 6) 2 Expand from 1 to 10 clients (Calibration and Configuration) 6) 3 Expand from 1 to 5 clients (Configuration Only) 7) 4 Expand from 5 to 10 clients (Configuration Only) 7) 5 Expand from 1 to 10 clients (Configuration Only) 7) 6 Expand Existing DHH820-DMS (already have 21 CFR Part 11) No 0 Notes: 1) Latest version of Mobility Interface Software CD set is included. CD sets for previous versions are available on a request basis. 2) Entry of 1 for Digit 11 provides the full DMS. Entry of 2 provides a version of DMS that only supports uploading, downloading, and documenting of device configuration information. 3) Zero entry of Digit 12 is required and only valid when expanding an existing DMS that has already been purchased 4) Non-zero entry of Digit 12 is required for any new DMS purchase. These options may only be selected if Digit 11 is a one. 5) Non-zero entry of Digit 12 is required for any new DMS purchase. These options may only be selected if Digit 11 is a two. 6) Non-zero entry of Digit 14 is only valid if Digit 12 is zero, and requires supply of existing DMS serial number with the PO. These options may only be selected if Digit 11 is a one. 7) Non-zero entry of Digit 14 is only valid if Digit 12 is zero, and requires supply of existing DMS serial number with the PO. These options may only be selected if Digit 11 is a two. Additional ordering information Device Management System (DMS) Software - Accessories Catalog No. Mobility Interface Software CD set, latest version (698B277U01) 3KXD311800L0041 DMS Operations Manual, printed hard copy (694A200U01) 3KXD311820R4301 One copy included with order at no charge. Pdf instructions included on CD DMS Installation and Upgrade Guide, (694A201U01) 3KXD311820R4401 One copy included with order at no charge. Pdf instructions included on CD Annual Subscription for Updating DMS Server with Integral Client 3KXD311820L0101 with 5 Clients 3KXD311820L0102 with 10 Clients 3KXD311820L0103 Standards Products = 10
11 (This page left intentionally blank) 11
12 ABB has Sales & Customer Support expertise in over 100 countries worldwide ABB Inc. 125 East County Line Road Warminster, PA USA Tel: Fax: ABB Limited Howard Road, St. Neots Cambridgeshire, PE19 8EU UK Tel: +44 (0) Fax: +44 (0) The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (8.1.07) 2007 ABB. DS/DHH810 MFT 12
Process Tools. 2011 Selection Guide. inside for: for industrial instrumentation and electrical technicians. Loop Calibrators. Pressure Calibrators
Process Tools for industrial instrumentation and electrical technicians 2011 Selection Guide Look inside for: Loop Calibrators Pressure Calibrators Temperature Calibrators Multifunction Process Calibrators
USER S MANUAL. MFT 4000 Calibrator MFT 4005 Calibrator with HART Trims MFT 4010 Calibrator with HART Communications
File No. MFT 4000:440-6 Firmware: v 4.0 & greater Nov. 2006 MFT 4000 Calibrator MFT 4005 Calibrator with HART Trims MFT 4010 Calibrator with HART Communications USER S MANUAL MFT 4000 SERIES USER S MANUAL
OPERATIONS MANUAL. Hand-Held Configuration Devices Mobility DHH800-MFC. DHH800-MFC Configuration Device with HART Communications ABB
OPERATIONS MANUAL Hand-Held Configuration Devices Mobility DHH800-MFC DHH800-MFC Configuration Device with HART Communications ABB TRADEMARKS AND REGISTRATION HART is a registered trademark of the HART
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Quick Start Guide 00825-0100-4764, Rev DA March 2014. Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator
Quick Start Guide 00825-0100-4764, Rev DA Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator Quick Start Guide NOTICE This document provides basic guidelines for the Rosemount 8714D. It
Hand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators
Features Ranges 2.5 mbar to 700 bar Accuracy from 0.025% full scale (FS) Integral combined pressure/vacuum pump Dual readout: input and output 4 to 20 ma loop test: auto step and ramp Intrinsically safe
DPI 260 SERIES: Digital Pressure Indicators
DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
General Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided
The L&J Engineering Model MCG 1500SFI Servo Gauge
PRODUCT DATA SHEET The is the most compact and lightest servo available today. Accuracy / repeatability of 1/32 inch (0.8mm) Product and Interface, custody transfer Wireless Infrared Calibration Advanced
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Multifunction Process Calibrator
725 Multifunction Process Calibrator Product Overview PN 1549644 English January 2000 Rev.2, 8/05 2000-2005 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision J Features 4 to 20
KNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
Device Management Jonas Berge Emerson Process Management
Device Management Jonas Berge Emerson Process Management 1 Topics What is intelligent device management? Integrated operations Why do I need a handheld field communicator? With fieldbus, I can do everything
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer
450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon
The PACE5000 Modular Pressure Controller/Indicator
GE Sensing The PACE5000 Modular Pressure Controller/Indicator First in a new generation of modular, high precision Druck pressure controllers/indicators, designed for ATE and test bench applications. The
Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
Wireless Data Logger Monitoring Systems
Wireless Data Logger Monitoring Systems Table of Contents About MadgeTech, Inc. Wireless Systems & Components Wireless Data Loggers 2000A Wireless Data Logger Models MadgeTech Cloud Services MadgeTech
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
Rackmount Intelligent Pressure Scanners
Rackmount Intelligent Pressure Scanners NetScanner System 9816/98RK-1 FEATURES ±0.05% Accuracy 100 Hz EU Throughput Autonegotiating 10/100/1G Base T Ethernet - TCP and UDP Protocol Pressure Ranges up to
Measurement Products. Scalable device management Productivity enhancement that grows with your business
Measurement Products Scalable device management Productivity enhancement that grows with your business Scalable device management Enabling productivity enhancement ABB s scalable device management offering
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
GE Druck. Hand Pumps Pneumatic/Hydraulic hand pump Product Guide. Pneumatic hand pumps from -1 to 60 bar. Hydraulic hand pumps from 0 to 1000 bar
g Hand Pumps Pneumatic/Hydraulic hand pump Product Guide GE Druck Pneumatic hand pumps from -1 to 60 bar Hydraulic hand pumps from 0 to 1000 bar Controlled pressure release and adjustment Adjustable pressure
Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3
Typical Applications Typical Applications Construction Transmitter Assembly Pipe & cable locator transmitter Transmitting active signals for the location of buried pipes and cables High impact ABS Weight
New thermometers and accessories to grow your business
New s and accessories to grow your business Fluke is introducing a new family of digital, contact s and accessories. Here is the information you will need to order, promote and sell these exciting, new
Loop Calibration and Maintenance
Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
Instruction Manual FL
3. Operation Overview The most common used features (such as displaying force, peak hold, zero and changing of displayed units) can all be done by pressing a single dedicated key identified on the front
RUSKA PRODUCTS - PRICE LIST
RUSKA PRODUCTS - PRICE LIST Effective Date: This price list is effective January 1, 2010 and supersedes all previous price lists for the items contained herein. NVLAP An optional ISO 17025 accredited calibration
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
rigel 288 Electrical Medical Safety Analyser Key Features Applications
rigel 288 Electrical Medical Safety Analyser Key Features Versatile Test in Accordance with the leakage requirements of IEC/EN 60601-1, AAMI and NFPA, IEC 62353 (VDE 0751-1) using separate IEC 60601 and
HP ProDisplay P17A LED Backlit Monitor. User Guide
HP ProDisplay P17A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
USB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Kit Highlights and Key Features
AF-OLK6 Series Fiber Optic Test kit (Data Storage Kit) Product: OLK6 Series Date: Aug:2007 Rev: 01 Description The AF-OLK6 series test kits are the complete solution necessary for the installer to test,
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!
-86 C Freezer Accessories New Brunswick Freezer Accessories A wide selection of racks, monitoring systems and more! A Wide Range of Accessories The Perfect Complement for Your Ultra-Low Temperature Freezer
USB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Fluke 3000 FC Series Test Tools Technical Data
Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids
PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal
APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer
PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories
86 C Freezer Accessories More Choices Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories 2 A Wide Range of Accessories The perfect complement for your
Nardalert S3 Non-Ionizing Radiation Monitor
Patent Pending Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Interchangeable Lanyard or Belt Clips Comprehensive
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
M O D U L E - 7 E Model CS-Caliprompter Operator s Manual
O P E R A T I O N S A N D P R O C E D U R E S F O R C S - C A L I P R O M P T E R A N D A C C E S S O R I E S Model CS-Caliprompter Visual screen display allows easy step-by-step operation On-site programming
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
Models SFP33 & SFP32 Pressure Transmitters
SFP33 Flow-Through Pressure Transmitter SFP32 Single-Ended Pressure Transmitter DS-PR-SFP-eng April, 2016 Data Sheet Models SFP33 & SFP32 Pressure Transmitters Pressure Brooks Seal Free Pressure Measurement
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
ValveLink Mobile Software
Quick Start Guide ValveLink Mobile Software Version 4.0 ValveLink Mobile Software ValveLink Mobile software lets you configure, calibrate, and troubleshoot FIELDVUE DVC2000, DVC6000, DVC6000f, DVC6200,
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0
Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm
Data Logging Solutions from Lascar Electronics
Data Logging Solutions from Lascar Electronics Remote Monitoring EL-BT-2 Bluetooth and Humidity Data Logging The EL-BT-2 data logger measures and stores over 1 million temperature and humidity readings.
Wireless Sensor Networks
Wireless Sensor Networks WIB Seminar 25 april 2007 John van Gorsel Product Manager Emerson Developed an Architecture to Extend Plant Visibility Wirelessly Plant Network Asset Tracking Security Wireless
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems
Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you
4Sight Calibration Management Software
GE Measurement & Control Solutions 4Sight Calibration Management Software 4Sight calibration and maintenance management software provides visibility to the assets, data, and resources that affect maintenance,
Precision Pressure Indicator Model CPG2500
Calibration Technology Precision Pressure Indicator Model CPG2500 Data Sheet CPG2500 11/2014 Applications Pressure standard for calibration labs Transfer standard with remote transducers Pressure instrument
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002
AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002 First Edition MONITORING AND LABORATORY DIVISION August
Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
E-Version SECTION 15318 - CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT
SECTION 15318 - CHLORINATION SYSTEM PART 1 - GENERAL 1.1. SCOPE OF WORK A. Under this item the Contractor shall furnish and install a sodium hypochlorite solution metering system complete with all accessories
Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
Mass Flow Meters & Controllers
HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) 0-5 VDC or 4-20
3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19
3NNet USERS MANUAL KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19 RACK MOUNTABLE 4 / 8 / 16 PORT PS2 KVM SWITCH Rev 1.1 TABLE OF CONTENTS INTRODUCTION.. 3 FEATURES... 3 PACKAGE CONTENTS........
HP ProDisplay P19A LED Backlit Monitor. User Guide
HP ProDisplay P19A LED Backlit Monitor User Guide 2013 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F
Wireless Asset Monitoring - Local Food Safety Software BA/WAM-L-F Software Installation and User Guide System Overview The BAPI Wireless Asset Monitoring Local (WAM Local) Software receives temperature
Thermistor Thermometer MODEL NO. 93210-00
Thermistor Thermometer MODEL NO. 93210-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail:
GENERAL CATALOG. Calibration Technology Starts Here! Volume 2, Issue 1
GENERAL CATALOG Calibration Technology Starts Here! Volume 2, Issue 1 Martel Electronics offers a diversified line of hand held and bench calibrators, process instruments, process indicators, and power
Auto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
PITE 3921 Battery Monitoring System User Manual P-140606-V1.0
User Manual P-140606-V1.0 4/F, Bldg A, Chiwan Industrial Park, Shaodi Rd., Chiwan, Shekou Area, Shenzhen, China TEL: +86-755-2680 5759 FAX: +86-755-2688 0310 www.pitetech.com 1 Catalog 1. INTRODUCTION...
2002 IS Catalog. Page
00 IS Catalog Page Introduction... 47 Transmitter (8 V entity parameter) KFD-CR-Ex1.30.00 (-wire transmitter)... 48 KFD-CR-Ex1.30.300 (- or 3-wire transmitter)... 49 KFD-CR-Ex1.30.300 90C (- or 3-wire,