XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY



Similar documents
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC series BALANCED HYDRONIC VALVES 2 -WAY AND 3 -WAY

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Oil and Coolant Circulating Heating System. Model - OCSM

Assisted lift operated 2/2-way solenoid valves Type EV250B

Automatic control equipment for HVAC systems

3/2-way Solenoid Valve, direct-acting, NC or NO

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Cooling system components, removing and installing

Why and How we Use Capacity Control

T7079A,B Solid State Remote Temperature Controllers

Stainless Steel Single and Dual Circulation Kits

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Operators manual Basic water heater

Laddomat Charging unit

Unit 24: Applications of Pneumatics and Hydraulics

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

STC 3S A Series Solenoid Valves

Description of functions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Data sheet ECC 12 and 22

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

3 Port Solenoid Valve

PRESSURE REDUCING CONTROL VALVE

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

HERZ-Thermal Actuators

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

G670 Intermittent Pilot Ignition Controls

AMX300 DirectConnect Mixing Valve Kits

Select Radiators Installation Guide

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

SELECTION, APPLICATION & MAINTENANCE

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Wireless 7 Day Programmable Room Thermostat

Cooling system components, removing and installing

! WARNING. Before using product, read and understand instructions.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

TAC Erie VT/VS PopTop Series Two Position Spring Return Valves

V94 BULK TAPE DEGAUSSER

Submersion/Insertion Toroidal Sensor

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

SunMaxx Solar Filling Station Operating Instructions

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Your safety and the safety of others are very important.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

OCTOPUS SELECTION & INSTALLATION GUIDE

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

PNEUMATIC CONTROLS Selection and Description

Butterfly Valves PN 6/10/16 for flanged connection

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Drayton Digistat +2RF/+3RF

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

WD-AMX Water Detection Controllers

Cable Plug acc. to DIN EN , Form A

Air Conditioning Sign-Off Sheet

4 Posiflow Proportional Solenoid Valves

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Digi-Motor Installation Guide

Single sub-base valve

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

SunMor SM-V30 Solar Water Heater Installation Manual

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

E2 Series Electric Furnaces

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Technical Information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

WHOLESALE DIRECT INC WEST 65TH STREET

Transcription:

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to 21 oc, and the heating pump will be switched on. Honeywell VC Series balanced hydronic valves allow greater control of hot and/or cold water flow. The VC Series is designed for both domestic boiler heating, and domestic cooling applications. FEATURES 2-way or 3-way Control by a low or line voltage SPST or SPDT controller Minimal actuator power consumption Option of valve timings to suit the application 0-95 o C fluid temperature Pressure differential up to 4 bar Double insulated actuator Quick connect electrical connections 0-65 o C ambient temperature Safe use with potable water Quick and easy replacement of moving parts Actuator head installation does not require draining of the system OPERATING FEATURES VC Series 2-position hydronic valves are used in domestic and small commercial applications to control the flow of hot and/or cold water. They consist of an actuator, valve and a cartridge assembly. 2-way valves are designed for on-off 'zone' control of domestic systems. 3- way valves can be piped for either diverting or mixing valve applications in domestic central heating and/or cooling systems. Both versions can be used to control individual fan coil, baseboard radiator or convector applications. Depending on the model selected they can be controlled by a low or line voltage SPST or SPDT controller, such as a room thermostat, aquastat or flow switch. VC Series hydronic valves are designed to take advantage of sinusoidal valve actuator travel, and therefore operate silently and without water hammer. Through internal logic the actuator only takes power while driving the valve to the commanded position. Two valve timings are available: the fast response time is preferable for combi-boilers, the slower response time is applicable for critical applications. The actuator head is removable without affecting the integrity of the water system. All actuator versions are interchangeable with any valve body, offering the highest flexibility for boiler production line assembly, and maintenance. The valve piston construction allows for port sealing that is independent of the differential pressure across the valve. Flow through the 2-way valve can be in either direction, so the ports are not designated. 3-way valves are suitable for both diverting water from AB to A or B, and from A or B to AB. EN0R8411 R1

SERIES OVERVIEW Actuator Control input Electrical connections Options Body Pipe connections 24 Vac SPST Molex quick Auxiliary switch 2-way BSPP external 100-130 Vac SPDT connector (SPDT) port A 3 -way BSPP internal 200-240 Vac 1 metre cable BSPT NPT Sweat Compression Flare (inverted and standard) CONSTRUCTION AND OPERATION All moving and sealing parts of the valve are constructed in the cartridge assembly. The ports are sealed with O- rings on the outer surface of the piston. When the valve stem is driven down to open port A the water will flow through the hollow piston to the other port. In case of a 3-way valve with the piston driven down port B is sealed, allowing flow between port AB and port A. With the stem up the flow is between port AB and port B. The valve family offers a variety of versions of pipe connections to suit the different applications. The valve pressure loss characteristic is dependent on the pipe connections/ dimensions. For the actual valve rating please refer to the specification section. 2-way valve With an SPDT (3-wire) actuator On a call for heat, the NO controller contacts close and the valve opens. When the valve is fully open, the cam closes switch SW1 and opens switch SW2. When the need for heat is satisfied the NC controller contacts close, energising the valve through SW1 and closing the valve. When the valve is fully closed, the cam closes SW2 and opens SW1. The valve is ready for the next call for heat. With an SPST (2-wire and common) actuator On a call for heat, the controller contacts close, RLY1 is energized making the NO contacts in switch SW3 causing the valve to open. When the valve reaches the fully open position the cam closes switch SW1 and opens switch SW2. When the need for heat is satisfied, the controller contacts open, RLY1 is de-energized and the valve motor is driven through SW1 and the NC contacts of SW3. When the Closed Figure 1 Fluid flow through 2-way valve Figure 2 Fluid flow through 3-way valve Open EN0R 8411 R1 2

CONSTRUCTION AND OPERATION valve reaches the fully closed position, the cam closes SW2 and opens SW1. The valve is ready for the next call for heat. For both types of actuator a power failure will leave the valve at the position it was when interrupted. When power is restored, the valve will respond to controller demand. 3-way diverter valve With an SPDT (3-wire) actuator On a call for heat, the NO controller contacts close, the valve closes port B and opens port A. When port A is in the fully open position the cam closes limit switch SW1 and opens limit switch SW2. When the need for heat is satisfied the NC controller contacts close, energising the valve through SW1, causing port A to close. When port A is fully closed the cam closes SW2 and opens SW1. The valve is ready for the next call for heat. With an SPST (2-wire and common) actuator On a call for heat the controller contacts close, RLY1 is energized making the NO contacts in switch SW3, causing port B to close and port A to open. When port A reaches the fully open position the cam closes switch SW1 and opens switch SW2. When the need for heat is satisfied, the controller contacts open. RLY1 is deenergized making the NC contacts in SW3 and port A is driven closed through SW1 and the NC contacts of SW3. When port A is in the fully closed position the cam closes SW2 and opens SW1. The valve is ready for the next call for heat. For both types of actuator a power failure will leave the valve at the position it was in when interrupted. When power is restored, the valve will respond to controller demand. Wiring Figures 3 and 4 show wiring connections for 2-way and 3-way valves. Port A open and closed denotes valve open and closed for 2- way, and AB-A open and AB-B open for 3-way valves respectively. A means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring. On Molex connector models, actuator and auxiliary switch voltages must be the same to meet the approval requirement. For mixed voltages, the cable assembly version is recommended. S.P.D.T. Controller S.P.D.T. Controller Brown Black Blue Port A Close Port A Close Open VC Hydronic valve Cam AC Motor Figure 3 Logic sequence diagram with 3-wire actuator for SPDT controller Brown Black Blue Open VC Hydronic valve Cam AC Motor Figure 4 Logic sequence diagram with 2-wire + common actuator for SPST controller 3 EN0R8411 R1

SPECIFICATIONS Voltage Colour-coded label 24 V 50-60 Hz Blue 100-130 V 50-60 Hz Black 200-240 V 50-60 Hz Red Pipe fitting sizes 3/8" 1/2" 3/4" 1" 15 mm 22 mm 28 mm Power consumption 4 VA (when valve position changes) Auxiliary switch rating 2,2 (1,0) A @ 250 V, 50-60 Hz (minimum 0,05 A @ 24 Vdc) Nominal timing Available in 2 versions: 1. Valve opens in 7 seconds 2. Valve opens in 24 seconds (20% faster for 60 Hz) I E Flare E E - - - - - Inverted Flare - I - - - - - Sweat - E E E - - - BSPP - I E I E I - - - BSPT - - I - - - - NPT - - I I - - - Compression fitting - - - - E E E Internally threaded Externally threaded Electrical termination 1. Molex : requires mating connector - ordering number 39-01-2060 Contacts: Mini-Fit 5556 Series 2. With integral 1 m leadwire cable Maximum ambient temperature 65 o C Min. and max. fluid temperatures 0-95 o C (short duration peak: 120 o C) Pressure rating Static - 20 bar Burst - 100 bar Max. operating pressure differential 4 bar Flow rating Dependent upon body configuration See figures 6 and 7 Travel (%) Figure 5 3-way valve diverting flow characteristic at constant pressure on port AB Flow 2-way: flow can be in either direction. When the actuator is not mounted the valve is in the closed position. 3-way: bottom port is marked AB. The end ports are marked A and B. When the actuator is not mounted port A is closed. Valve material Body Bronze Cartridge Ryton (polyphenylene sulphide) Noryl (polyphenylene oxide) O-ring seals EPDM rubber Stem Stainless steel Actuator cover Noryl (94V-0) Actuator base Ryton (94V-0) Dimensions See figure 7 Pressure loss (m H 2O) Figure 6 Valve pressure loss characteristic EN0R8411 R1 4

SPECIFICATIONS Pipe fitting 2-way valve 3-way valve C Nominal flow C D Nominal flow rating Kv rating Kv 15 mm compression 98 3,4 98 136 4,3 22 mm* compression 112 6,8 112 140 8,6 28 mm* compression 112 7,7 112 140 8,6 3/4" BSPT(internal) 94 6,8 94 130 8,6 3/4" NPT 94 6,8 94 130 7,7 1/2" BSPP (external) 98 3,4 98 136 4,3 3/4" BSPP 94 6,8 94 130 7,7 1" BSPP 94 7,7 94 136 8,6 1/2" sweat 98 3,4 98 136 4,3 3/4" sweat 94 6,8 94 132 8,6 1 "sweat 94 8,6 94 136 8,6 3/8" flare 98 2,1 98 136 2,6 1/2" flare 98 3,4 98 136 3,4 1/2" inverted flare 98 3,4 98 136 4,3 All dimensions in mm * Includes compression nuts and olives Figure 7 Valve dimensions Terminal Action Wire colour 1 Com* Orange 2 Neutral Blue 3 Closed Brown 4 NO* Grey 5 NC* White 6 Open Black * Terminals 1, 4 and 5 are only connected if an auxillary switch is employed. NO, NC refers to the port A closed position. *Auxilliary switch models Valve Port A *Auxilliary switch models Valve Port A Figure 8 Wire terminal colour coding 5 EN0R8411 R1

INSTALLATION DATA WARNING lnstaller must be a trained, experienced service person. When installing this product: Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure it is suitable for your application. Always conduct a thorough checkout after installation. CAUTION Figure 9 Plumbing Disconnect power supply before wire connection to prevent electrical shock and equipment damage. It is advisable to remove the actuator head from the valve body for ease of installation. Fit the actuator head in the most convenient position for wiring. Plumbing The valve may be plumbed in any angle but preferably not with the actuator head below the horizontal level of the valve body. Make sure there is enough room around the actuator head for servicing or replacement. 1. Disconnect power supply before servicing to avoid electrical shock or equipment damage. 2. Disconnect leadwires to actuator head, or depress tab on Molex connector and remove. Where appropriate, label wires for rewiring. On sweat fitted valves, the cartridge is shipped loose or is removed to avoid being damaged during the solder operation. On 24 V systems, never short circuit the valve coil terminals. This may burn out the heat anticipator in the thermostat. To remove the actuator head 25 mm clearance is needed above the actuator. When used to form part of a central heating system, do not locate it where it will block the system vent, cold feed or any bypass when the valve is closed. Mount the valve directly in the tube or pipe. Do not grip actuator head while making and tightening plumbing connections. Either hold valve body in your hand or attach adjustable spanner across the hexagonal or flat faces on the valve body. Compression models For compression fitted models, tighten the compression nuts enough to make a watertight seal. Take care not to overtighten. To install a replacement actuator head 3. The actuator head is automatically latched to the valve (see figure 10). To remove, lift up on the latch mechanism located directly below the red manual open lever. Press the actuator head down towards the body with moderate hand force and turn counter-clockwise by 1/8 turn (45 degrees) simultaneously. Lift the actuator head off the valve body. NOTE: The actuator can also be installed at right angles to the valve body but in this position the latch mechanism is not engaged. 4. Install the new actuator head by reversing the process in (3). 5. Reconnect leadwires or Molex connector. 6. Restore power. Important Installation of a new actuator head does not require draining the system providing the valve body and cartridge assembly remain in the pipeline. EN0R8411 R1 6

INSTALLATION DATA Figure 10 Latch mechanism ADJUSTMENT AND TESTING DATA Manual opener The manual opener can be manipulated when in the up position. The motorized valve can be opened by firmly pushing the red manual lever down to midway and in (only possible if the actuator is in the upper position). This holds all ports in the open position, and with auxiliary switch models the NO switch is closed. Ports A and B of 3-way valves are opened. This 'manual open' position may be used for filling, venting or draining the system, or for opening the valve in case of power failure. The valve can be restored manually to the closed position by depressing the red manual lever lightly and then pulling it out. The valve actuator returns to the automatic position when power is restored. Checkout 1. Raise the set point of the thermostat above room temperature to initiate a call for heat. Valve position indicator should move downward to the open position. 2. For all auxiliary switch models, monitor the control devices. 2-way valve: check that the valve opens, the auxiliary switch (if present) closes, and at the end of the opening stroke the circuit to the circulator or another valve is made. 3-way valve: check that port A opens, port B closes, the auxiliary switch (if present) operates, and at the end of the opening stroke the circuit to the circulator or another valve is made. 3. Lower the set point of the thermostat below room temperature. 4. Observe the control devices. 2-way valve: check that the valve closes and all auxiliary equipment stops. 3-way valve: check that port A closes and all auxiliary equipment stops. SERVICE DATA This valve should be serviced by a trained, experienced service person. 1. If the valve is leaking, drain system or isolate valve from the system. 2. Check to see if the cartridge needs to be replaced. 3. If the gear train or the motor is damaged, replace the actuator assembly. NOTE: WARNING Honeywell hydronic valves are designed and tested for silent operation in properly designed and installed systems. However, water noises may occur as a result of excessive water velocity. Piping noises may occur in high temperature (over 100 o C) systems with insufficient water pressure. 7 EN0R 8411 R1

ORDERING SPECIFICATION 2-port valves Model Wiring Pipe KV Type Differential Connections Connections Pressure for Close-off VC4013AF1000 2 wire + common ½" BSPP/15 mm 3.4 Straight through 4 bar VC4013AJ1000 2 wire + common ¾" BSPP 6.9 Straight through 4 bar VC4013AP1000 2 wire + common 1" BSPP 7.7 Straight through 4 bar VC6013AF1000 3 wire ½" BSPP/15 mm 3.4 Straight through 4 bar VC6013AJ1000 3 wire ¾" BSPP 6.9 Straight through 4 bar VC6013AP1000 3 wire 1" BSPP 7.7 Straight through 4 bar 3-port valves Model Wiring Pipe KV Type Differential Connections Connections Pressure for Close-off VC4013ME1000 2 wire + common ½" BSPP/15 mm 4.3 Diverting 4 bar VC4013MH1000 2 wire + common ¾" BSPP 7.7 Diverting 4 bar VC4013MP1000 2 wire + common 1" BSPP 8.6 Diverting 4 bar VC6013ME1000 3 wire ½" BSPP/15 mm 4.3 Diverting 4 bar VC6013MH1000 3 wire ¾" BSPP 7.7 Diverting 4 bar VC6013MP1000 3 wire 1" BSPP 8.6 Diverting 4 bar Honeywell Control Systems Limited Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom Helping You Control Your World EN0R 8411 R1