Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description



Similar documents
Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Sprinkler Identification Numbers

Model/Sprinkler Identification Numbers

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

HIGH VELOCITY WATER SPRAY NOZZLE

Sprinkler Identification Numbers (SINs) Technical Data

Technical Data. Installation

Model KFR56 Series Quick Response Standard Spray

Quick response concealed horizontal sidewall sprinkler

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

TECHNICAL DATA. Dry 122a. November 12, 2013

esfr pendent sprinkler vk510 (k25.2)

Float and Thermostatic Traps Series H, C and X

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

1805 Series Relief Valves

Model F1FR Series Quick Response Glass Bulb Sprinklers

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

Antifreeze Solutions in Residential Fire Sprinkler Systems

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

STORED PRESSURE STAINLESS STEEL

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Inspection and Testing of Water-Based Systems

PREPIPED LIQUID FUEL MANIFOLDS PLPM

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

PBX Series Quick Fit Connector Bimetallic Steam Traps

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Your safety and the safety of others are very important.

TYPE E Main Valve Sizes 3 /8 through 12

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

Morrison Bros. Co. General Product Specifications

Viking Residential Sprinkler Installation Guide

BERMAD Fire Protection

167D Series Switching Valves

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Diesel Fuel Systems. Injection Nozzles

Steam System Best Practices Condensate System Piping

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Installation Manual DIAPHRAGM WELL TANK

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Air Eliminators and Combination Air Eliminators Strainers

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

San josé OWNER S MANUAL

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

OREGON FIRE CODE Interpretations and Technical Advisories

Series 510 Submersible Level Transmitters

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

NFPA31FuelOilPiping 1 Revised

C I T Y O F S E L M A F I R E D E P A R T M E N T

4 Posiflow Proportional Solenoid Valves

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

FOAM CHAMBER MODEL - FC

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

The following definitions apply with regard to requirements specified in this document:

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

FIVE YEAR CERTIFICATION REPORT

In-Line Air Separators

08.08 Vic-Check Valves

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Automatic Fire Sprinkler Submittal Requirements

SELECTION, APPLICATION AND MAINTENANCE

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

289 Series Spring-Loaded Relief Valves

orlando OWNER S MANUAL

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Transcription:

Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed for use in water spray fixed systems for fire protection applications where a high velocity water application may be required. There are two configurations: the basic Mulsifyre Nozzle shown in Figure 1 and the Mulsifyre Nozzle with Model F Dust Cap shown in Figure. Each configuration is available in six different models that provide a wide range of orifice sizes and water distribution characteristics. The Mulsifyre Nozzles are internal scroll type nozzles and they discharge a uniformly filled cone of relatively high velocity water droplets. Although the Mulsifyre Nozzles are designed primarily for use in fire extinguishment and control, they can also be used for exposure protection. The Mulsifyre Nozzles are typically used in water spray fixed systems for the protection of special hazards such as: oil filled transformers and switching equipment, flammable liquid and gas storage tanks chemical process equipment, conveyor systems, openings in fire walls, and other equipment that is defined as hazardous due to the possibility of a rapidly spreading fire. IMPORTANT Always refer to Technical Data Sheet TFP7 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Mulsifyre Nozzles with Model F Dust Caps are used in applications where protection is required against insect infestation or accumulation of debris within the nozzle. The Dust Cap is designed for both indoor and outdoor use. It is recommended that the end user be consulted with respect to the suitability of the materials of construction for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity, should be considered, at a minimum, along with the corrosive nature to which the nozzles may be exposed. The Model F thru F3 Mulsifyre Nozzles are a re-designation for the Gem Model F thru F3. NOTICE The Mulsifyre Nozzles described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The design of individual water spray fixed systems can vary considerably, depending on the characteristics and nature of the hazard, the basic purpose of the spraying system, the configuration of the hazard, and wind/draft conditions. Because of these variations as well as the wide range of available nozzle spray characteristics, the design of water spray fixed systems for fire protection must only be performed by experienced designers who thoroughly understand the limitations as well as capabilities of such systems. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Page 1 of FEBRUARY 1 TFP1

TFP1 Page of SCROLL (PASSES A 1/" PARTICLE) 1" DIA. (5, mm) 3/" NPT BODY Technical Data Approvals The Model F thru F3 Mulsifyre Nozzles are UL and ULC Listed, as well as FM Approved. The Model F thru F3 Mulsifyre Nozzles with Model F Dust Caps are UL and ULC Listed. Maximum Working Pressure 175 psi (1,1 bar). Also refer to Figure 3, Note Discharge Coefficient Refer to Figure 1 1-1/1" (7 mm) ACROSS WRENCH FLATS Water Distribution Refer to Figure 3 - Part 1 of. Optimum flow pressure is 3 to psi (,1 to,1 bar). Thread Connection 3/ inch NPT Physical Characteristics (Basic Nozzle) Body..................... Brass Scroll.................... Brass Physical Characteristics (Nozzle with Dust Cap) Body...Chrome Plated Brass Scroll.................... Brass Dust Cap................. EPDM Wire.............. Stainless Steel "L" COLOR CODE PAINTED ON WRENCH FLATS Design Criteria MODEL NUMBER F F F F F3 F3 NFPA GPM/psi 1/ Nozzle Placement Where direct impingement of water spray onto all of the protected surface is required by the authority having jurisdiction, the nozzles are to be spaced and directed so that their spray patterns will completely cover the plane-of-protection with the minimum required average density. With reference to Figure 3 - Part 1 of, use of the Design Spray Profile for the Design Spray Area will help assure that direct impingement on all surfaces will occur. The Design Spray Area shown at the top Figure 3 - Part of on Page consists of the square of length S within the circular Overall Spray Area. The maximum recommended axial distances given in Figure are based on maintaining the specified spray patterns under a maximum wind condition of 15 MPH ( km/h). Dust Caps The Model F Dust Caps are rated for indoor and outdoor use over a temperature range of - F to 15 F (-51 C to 5 C). A minimum residual (flowing) pressure of 15 psi (1, bar) is required to assure release of the Dust Cap. Main Pipeline Strainers Main pipeline strainers per NFPA 15 are required for systems utilizing Mulsifyre Nozzles since their waterways are less than 3/ inch (9,5 mm) diameter. Individual strainers are not required since the openings in the scrolls will pass a 1/ inch (3, mm) particle...3..7. 5.1 K-FACTOR FIGURE 1 MODEL F THRU F3 MULSIFYRE NOZZLES NOMINAL DIMENSIONS ISO/SI LPM/bar 1/ SCROLL BODY, 33,1 37, 3,9, 73, DUST CAP NOMINAL LENGTH "L" 1-5/" ( mm) 1-5/" ( mm) 1-5/" ( mm) 1-11/1" (3 mm) 1-13/1" (7 mm) -3/" (7 mm) COLOR CODE YELLOW RED ORANGE WHITE ALUMINUM GRAY RETAINING WIRE 5" (15 mm) MIN. FREE LENGTH FIGURE MULSIFYRE NOZZLES WITH DUST CAPS

TFP1 Page 3 of, 1, 1,, F, 1, NOTES: 1.. 3. Data applies to a maximum wind condition of 15 MPH ( km/h). Data applies to a residual (flowing) pressure range at the nozzle inlet of 3 to psi (,1 to,1 bar). (For pressures up to 175 psi (1,1 bar) consult Tyco Fire Protection Products Technical Services.) The shapes of the Design Spray Profiles remain essentially unchanged over the maximum recommended axial distance and the residual (flowing) pressure range of 3 to psi (,1 to,1 bar). DATA KEY OVERALL SPRAY PATTERN (RADIAL DISTANCE) DESIGN SPRAY PROFILE (S/) 1,, 3, F, 1, 1, F, 1, 1 1 1,, 3,,, 1, F3, 1, F3 1 1 1 F 1, 1,, 3,, 1 1 1, 3,, 5, 1 1 1 1 1 1 FIGURE 3 PART 1 OF WATER DISTRIBUTION DESIGN DATA

TFP1 Page of MAXIMUM RECOMMENDED AXIAL DISTANCE TO PLANE OF PROTECTION, NOZZLE AXIAL DISTANCE DESIGN SPRAY PROFILE (GRAVITY) 1 17 1 15 1 13 1 11 1 9 7 5 3 1 (GRAVITY) F3 F F3 F F F 3 ORIENTATION ANGLE (9 SHOWN) 5 S/ PLANE OF PROTECTION S/ DESIGN SPRAY AREA S OVERALL SPRAY AREA 9 1 135 15 1 ORIENTATION ANGLE FIGURE 3 PART OF WATER DISTRIBUTION DESIGN DATA 5,5 5,,5, 3,5 3,,5, 1,5 1,,5 S AXIS MAXIMUM RECOMMENDED AXIAL DISTANCE TO PLANE OF PROTECTION, METERS Installation Mulsifyre Nozzles must be installed in accordance with this section. General Instructions A leak tight 3/ inch NPT nozzle joint should be obtained with a torque of 1 to ft-lbs. (13, to, Nm). Higher levels of torque may distort the nozzle inlet and cause leakage or impairment of the nozzle. Step 1. With pipe thread sealant applied to the pipe threads, hand tighten the nozzle into the nozzle fitting. Step. Tighten the nozzle into the nozzle fitting using an adjustable crescent wrench. With reference to Figure 1 apply the adjustable crescent wrench to the nozzle wrench flats. Replacement Dust Caps When replacement Dust Caps are installed, there is to be a minimum of 5 inches (15 mm) of Wire (Ref. Figure ) between where the Wire is looped around the nozzle thread relief and attached to the Dust Cap. The minimum length of 5 inches (15 mm) will help to assure that there will be an unrestricted flow from the nozzle outlet during operation. Care and Maintenance The Mulsifyre Nozzles must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Mulsifyre Nozzles must never be painted, plated, coated or altered in any way after leaving the factory; otherwise, the spray performance may be impaired. Care must be exercised to avoid damage to the nozzles before, during, and after installation. Nozzles damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Frequent visual inspections are recommended to be initially performed for nozzles installed in potentially corrosive atmospheres to verify the integrity of the materials of construction as they may be affected by the corrosive conditions present for a given installation. Thereafter, annual inspections per NFPA 5 are required.

TFP1 Page 5 of Water spray fixed systems for fire protection service require regularly scheduled care and maintenance by trained personnel. In addition to inspecting nozzles for proper spray performance during water flow trip tests of the system, it is recommended that nozzles be periodically inspected for broken or missing parts (including dust caps where applicable), loading/obstructions, or other evidence of impaired protection. The inspections should be scheduled weekly or as frequently as may be necessary, and corrective action must be taken to ensure that the nozzles will perform as intended in the event of a fire. For installations subject to freezing and where dust caps have been installed, a periodic inspection must be performed for evidence of ice build-up from trapped condensate which could affect the proper release of the dust cap. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 5), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. It is recommended that water spray fixed systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and P/N. Mulsifyre Nozzles Specify: Model (number) Mulsifyre Nozzle, P/N (specify): Model F...P/N 9--1- Model F...P/N 9--1- Model F...P/N 9--1- Model F...P/N 9--1- Model F3...P/N 9--1-3 Model F3...P/N 9--1-3 Mulsifyre Nozzles with Dust Caps Specify: Model (number) Mulsifyre Nozzle with Model F Dust Cap, P/N (specify): Model F... P/N 9-1-1- Model F... P/N 9-1-1- Model F... P/N 9-1-1- Model F... P/N 9-1-1- Model F3... P/N 9-1-1-3 Model F3... P/N 9-1-1-3 Replacement Parts Specify: Model F Dust Cap Assembly, P/N 5--1-1 NOTE: The Model F Dust Cap may only be used for replacement on Mulsifyre Nozzles with chrome plated bodies. Otherwise failure for the Dust Cap to release may occur with resulting impairment of the system. Specify: Blow-Off Cap Assembly for use with discontinued Model FB thru F3B Mulsifyre Nozzles, P/N 5--1-1 NOTE: The Blow-Off Cap Assembly may only be used with the previously offered Model FB thru F3B Mulsifyre Nozzles.

TFP1 Page of GLOBAL HEADQUARTERS 1 Pennbrook Parkway, Lansdale, PA 19 Telephone +1-15-3-7 Copyright 1 Tyco Fire Products, LP. All rights reserved.