SELECTING PRESSURE TRANSMITTERS TO IMPROVE CENTRIFUGAL COMPRESSOR SAFETY & EFFICIENCY



Similar documents
Best Practices for Reducing Transmitter Life Cycle Costs

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

Gas Custody Transfer Calibration

Select the Right Relief Valve - Part 1 Saeid Rahimi

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

A simple method to determine control valve performance and its impacts on control loop performance

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Energy and Flow Measurement for Hydronic Systems

Understanding maintenance strategies

AGING CHARACTERISTICS OF NUCLEAR PLANT RTDS AND PRESSURE TRANSMITTERS

V-Cone, An Alternative to Orifice Meter in Wet Gas Applications

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications

Rosemount 1199 Submersible Seal

Operations & Maintenance 101 Maintenance Strategies and Work Practices to Reduce Costs

Replacing Displacers with Guided Wave Radar

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

CALIBRATION PRINCIPLES

Custody Transfer Measurement. with the V-Cone Flowmeter

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Rense Product Range. Customized Humidity Solutions. Rense Product Range

Calibrating Differential Pressure Sensors

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Best Practices for Controller Tuning

export compressor instability detection using system 1* and proficy** smartsignal software

Principles of Direct-Operated Regulators

GE Energy Transformer Monitoring: How Moving forward from Monitoring to Diagnostics can Positively Impact Indian Business and Industry

Compressed Air System Leaks:

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

HydroCOM. Experience real capacity control and energy savings

Load Cell Troubleshooting

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Lambda Tuning the Universal Method for PID Controllers in Process Control

Frequently Asked Questions

Liquid level measurement using hydrostatic pressure and buoyancy

Thermal Dispersion Mass Flow

Device Management Jonas Berge Emerson Process Management

Operational Overview and Controls Guide

Pressure Transducer to ADC Application

Saeid Rahimi. Effect of Different Parameters on Depressuring Calculation Results. 01-Nov Introduction. Depressuring parameters

Signature and ISX CM870 Fuel System

Chapter 3.5: Fans and Blowers

Choosing Between Electromechanical and Fluid Power Linear Actuators in Industrial Systems Design

Chapter 10. Control Design: Intuition or Analysis?

Fluid Power and Fluid Control Solutions For Tire Manufacturing

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Operations & Maintenance 201 Using online monitoring and predictive diagnostics to reduce maintenance costs

KNC Model 3666 Automatic Pressure Calibration System

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Gas Well Deliverability Testing

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Rosemount 1199 Submersible Seal

Study the following diagrams of the States of Matter. Label the names of the Changes of State between the different states.

Pressure sensors for automotive HVAC systems

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

How To Clean Water From An Ammonia Refrigeration System

Repair, Modify or Replace?? What is the right answer?? By : Joe Mozeika

PRODUCT PROFILE FEATURES

Why and How we Use Capacity Control

Natural Gas Well Automation using Kingfisher RTU Products

How is Dew Point Measured Reliably?

The Precharge Calculator

A Practical Overview of Level Measurement Technologies

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

Pneumatic Proportional Valve Selection Made Simple

Rosemount 333 HART Tri-Loop

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

THE STRAIN GAGE PRESSURE TRANSDUCER

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

Chilled Water System Commissioning: Variable Primary Flow. John D. Villani, P.E. Associate Grumman/Butkus Associates

Thermal Mass Flow Meters

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Advances in Thermal Dispersion Mass Flow Meter Accuracy

ABB PSPS Erich Steinmann; Generator control-2013

Fundamental Principles of Rotary Displacement Meters

Rosemount Orifice Plate in Wet Gas

Recommended Practice for Software Acquisition

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Practical Application of Industrial Fiber Optic Sensing Systems

1. The Kinetic Theory of Matter states that all matter is composed of atoms and molecules that are in a constant state of constant random motion

Application Requirement

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

Rackmount Intelligent Pressure Scanners

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

RESPONSE TIME INDEX OF SPRINKLERS

Rosemount 333 HART Tri-Loop

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Introduction to Solid Modeling Using SolidWorks 2012 SolidWorks Simulation Tutorial Page 1

P O B o x S t. L o u i s, M O P h o n e : ( ) ~ E m a i l : w m h u I t a o l.

Transcription:

SELECTING PRESSURE TRANSMITTERS TO IMPROVE CENTRIFUGAL COMPRESSOR SAFETY & EFFICIENCY Mark Menezes Manager Pressure & PlantWeb (Americas) Rosemount Inc. Chanhassen, MN 55317 KEYWORDS Centrifugal compressor, safety, efficiency, transmitters, installed repeatability ABSTRACT Centrifugal compressors are widely used in the process and oil & gas industries. Correct transmitter selection is critical for these applications in particular, anti-surge and throughput control. Unfortunately, many user practices are based not on quantifiable engineering methodologies, but on experience valid more than a decade ago, but now obsolete. The objective is to allow the user to improve on the all-too-common surgeplus-10% rule, substituting rigorous methodologies to quantify application requirements and system performance. The paper will explain how transmitter performance especially response time and installed repeatability affects compressor safety. Then, methodologies and tools will be presented which allow users to quickly and reliably estimate these parameters, allowing the user to minimize unnecessary energy cost, without increasing safety risk. INTRODUCTION Surge is caused when the flow through a compressor is decreased to the point that momentary flow reversals occur. Surge is evidenced by vibration and pulsation, and if unchecked can cause severe compressor damage. As shown in Figure 1, if surge is detected, the surge control system will increase flow through the compressor, by quickly opening the blowoff valve for environmentally benign or low value gases, or the recirculation valve for hazardous or valuable gases. 1 Figure 1 Surge Control Schematic Gas Flow DP- Flow User DP Blowoff or Recirculate Mark Menezes Page 1 of 8

Even if surge is detected quickly, the relatively slow response time of the blowoff or recirculation valve causes the compressor to continue to operate in the surge condition for some period of time. Frequent cycling of the control system in and out of surge can cause output pressure variation, compressor wear, and poor efficiency. Although systems which detect incipient surge based on either rising temperature or instability of the flow and pressure measurements have been designed, each must be custom-designed to a certain machine and compression system. Worse, these systems tend to be safe and reliable only over the range of test conditions. 2 As result, most users operate off the compressor s surge line. As shown in Figure 2, the surge line is the minimum flow necessary, for each given pressure, to avoid surge. Points on the surge line which may of course be a curve - are typically determined experimentally. If the compressor is operating safety (1), and flow suddenly decreases, the compressor can move into a surge condition (2), unless the blowoff valve is opened, and flow increased (3). While too little blowoff can result in surge, too much blowoff (4) wastes fuel, since the compressor energy is vented into the atmosphere. Even if the gas is re-circulated, the energy added during compression must be removed by cooling, otherwise the compressor will overheat. Figure 2 Compressor Anti-Surge Control DP Surge - Safety Margin ( x ) Surge Line Control Line Safe Flow Ideally, the user should operate as close to surge as possible, without actually entering surge - most users operate at surge+x%. While a smaller x yields better efficiency, a larger x reduces risk of surge. Many users assign a fixed value 3 to x for example, 10%. However, it should be possible to optimize this value based on: Response time of the valve, measurement and control system, relative to the surge time of the compressor Uncertainties in the pressure and differential pressure measurements Stability of the compressor loading (but this is often not known at commissioning) The key variables, which should be considered and quantified for pressure transmitter selection, are: response time, relative to compressor surge time pressure and differential pressure measurement uncertainty Mark Menezes Page 2 of 8

MATCHING TRANSMITTER RESPONSE TIME TO SURGE TIME While transmitters and control systems typically respond much more quickly than valves, it is essential that the measurement (including transmitter and controller update) be updated at least as fast as the compressor surge rate. The reason for this is illustrated in Figure 3. If the measurement does not update as fast as the compressor surges, then surges may occur between updates, in which case surge may persist for a several cycles before being detected, possibly leading to compressor damage. Once, however, the measurement is fast enough, further reductions in response time are not useful, since the overall system response time is limited by the valve. Enter Surge Figure 3 Transmitters Not Fast Enough Pressure & DP OK Measurement Update Different compressors surge at different rates, and even the same compressor will surge at different rates in different applications. While actual surge rates are determined experimentally, generally: Surge time α flowrate / downstream_volume A compressor with a very high flowrate into a small volume will surge very quickly, while one with a relatively lower flowrate into a larger volume will surge more slowly. While the relationship is not exact enough to be used for quantifying actual surge rates, it does allow users to predict whether a given compressor should surge faster in one application than in another. Many users use vendor specifications to determine response time. It is important to understand that response time for any transmitter is dependent on the device s upper range. Transmitters designed to measure very low pressures must have very sensitive, and hence loose, diaphragms. These tend to response slowly. Transmitters designed to read high pressures have stiff diaphragms, and respond relatively more quickly. In addition to the response time of the mechanical components (lag time = τ), a fixed response time is added by the microprocessor of a smart transmitter (dead time = t d ). This means that, all else being equal, a smart transmitter will be slower than an analog ( dumb ) transmitter. However, all else is rarely equal, and it is not unusual for smart transmitters to be faster than analog. For example, Figure 4 shows response times for analog and smart transmitters from a leading pressure transmitter supplier. The smart transmitter has faster mechanical components due to faster sensor design, stiffer Mark Menezes Page 3 of 8

diaphragms, reduced volume of oil fill, etc. At pressure ranges where the mechanical response is fast and the microprocessor update rate dominates total response time in other words, at higher pressures the analog transmitter is faster. However, at pressure ranges where the mechanical response is slow and dominates total response time in other words, at lower pressures the smart transmitter is faster. This is significant, since if fast enough - smart transmitters can provide significant improvements in repeatability. Response Time (msec) Figure 4 Transmitter Response Time (msec) 350 300 250 200 150 100 50 0 Response Time 3051 - Lag Time 3051 - Dead Time td 1151 - Analog 25 inh2o 250 inh2o 1000 inh2o 300 psi 2000 psi τ τ Smart is faster Analog is faster QUANTIFYING TRANSMITTER REPEATABILITY Once the transmitter selected is fast enough to detect surge, additional improvements in response time do not provide user benefit, and the user should instead try to optimize repeatability. Returning to the surge line (originally shown in Figure 1), Figure 5 shows the impact of measurement uncertainty in pressure and differential pressure measurement. If the true flow is less than the measured flow, and the error exceeds the safety margin ( x in surge+x% control schemes), the system will unexpectedly enter a surge condition. If, on the other hand, the true flow exceeds the measured flow, and the compressor is operating close to the surge line, the control system will call for unnecessary blowoff, wasting energy. Minimizing measurement uncertainty allows the user to operate closer to the surge line (smaller x ), with no increase in surge risk, and reduce energy costs from unnecessary blowoff. Figure 5 Measurement Uncertainty DP Surge! Safety Margin ( x ) Measurement Uncertainty Unnecessary Blowoff ($$) Flow Mark Menezes Page 4 of 8

How can the user determine if the uncertainty will exceed the safety margin? Consider, for example, a DP transmitter with 0.1% reference accuracy installed on an orifice plate will the complete measurement system provide 0.1%, 1% or 10% flow repeatability? The first step is to identify factors that will cause a transmitter to be less accurate and repeatable outside of a laboratory. For a DP transmitter, key factors include: Ambient Temperature Variation: In the vast majority of real-world flow measurements, the transmitter can operate at a very different ambient temperature than the one at which it was calibrated. In some outdoor applications, ambient temperatures can vary more than 50 o F from calibration. These variations can have a significant effect, which is easily simulated on the bench blow warm air over a transmitter, and watch its output change. High Static Line Pressures: A high line pressure common in compressor applications can significantly affect the DP transmitter used to infer flow. To simulate this effect on the bench, the user should apply a small DP across a transmitter. Then, add several hundred pounds of additional static pressure to both sides of the transmitter. In theory, the measured differential pressure should not change. In reality, it does. Drift/Stability: The output of any analog component will vary over time. As with the ambient temperature effect described above, this can affect all flow technologies. Better, smart transmitters are more stable, requiring less frequent calibration than older, analog transmitters or transducers, without any sacrifice in accuracy and repeatability. Next, quantify the impact of these real-world conditions for the given application and transmitter of interest, using published specifications. Figure 1 shows this at 100% flow for three different transmitters: Better 0.075% smart transmitter Worse 0.075% smart transmitter Analog transmitter Figure 6 Flow Error From Differential Pressure Transmitter 4 Reference Accuracy Ambient Temp (+/- 25oF) Line Pressure (300 psig) Drift (12 months) "Better".075% ref accy "Worse".075% ref accy Analog (.2% ref accy) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Flow Error at 100% Flow (%) Mark Menezes Page 5 of 8

Even though the two 0.075% transmitters have the same reference accuracy, the better transmitter is less affected by these real-world effects. Note also that the realworld effects for all three transmitters overwhelm their reference/laboratory accuracies. While these errors may seem small at 100% flow, since the errors are fixed over the entire transmitter range, and DP α flow 2, small errors at 100% - and small differences in transmitter accuracy - are magnified at lower flowrates, as seen in Figure 7. Figure 7 Flow Error From Differential Pressure Transmitter Flowrate (scfm) DP "Better".075% "Worse".075% Analog 1000 100 0.09% 0.21% 0.65% 750 50 0.16% 0.38% 1.16% 500 25 0.37% 0.85% 2.60% 250 6.25 1.46% 3.40% 10.20% Conclusions from this typical application: Compressor flow measurements are of greatest importance at low flows, where surge can occur. At a flow of 25%, the analog transmitter contributes 10% repeatability. The reference accuracy of a transmitter is not useful for predicting installed repeatability. From Figure 2, when installed the two 0.075% transmitters differ by nearly 2% at a flow of 25%. The user can control some of the factors affecting installed repeatability. For example, more frequent calibration or calibration to a higher DP range will improve repeatability. However, both will increase operating costs. An obvious corollary is that better transmitters can be calibrated less frequently reducing maintenance cost and/or calibrated to a higher DP reducing energy costs yet still provide acceptable repeatability. The user benefit of reduced uncertainty is a smaller x in surge+x% control systems. Consider a given compressor in a given application in which x=10% provides acceptable surge risk, when using an analog transmitter with repeatability=10% at surge flow. If that transmitter is upgraded to a smart transmitter with repeatability=1.5%, it should be possible to operate with x=5%, for example, with no increase in surge risk. This will significantly reduce unnecessary blowoff and recirculation, and reduce energy cost. As shown in Figure 8, software tools are available that allow users to quantify installed repeatability for specific transmitters in user-defined application conditions. Mark Menezes Page 6 of 8

Figure 8 Software Tool Predicts Installed Repeatability 5 Total Probable Flow Error Due to DP Transmitter does not include effect of process pressure/temperature variation or primary element Fluid / Service: Transmitter Calibrated Span: Ambient Temp. Variation: Static Line Pressure: Calibration Frequency: Natural Gas to Boiler #1 0-100 in H20 Maximum Flow: 1000 scf/min 50 deg F Normal Flow: 250 scf/min 300 psig Value of Fluid:.009 $ / scf 12 months DP Transmitter DP Transmitter flow error at normal flow (250 scf/min) Annual Value of 3051 Flow Error Flow Error Improvement* Rosemount 3051C 1.46% $ 17285 - *Annual Reduced Rosemount 1151S 4.48% $ 53021 $ 35736 flow uncertainty Analog (typical) 10.19% $ 120534 $ 103249 (accuracy/repeatability) 3051 Improvement Rosemount 3051C - Rosemount 1151S $ 35736 Analog (typical) $ 103249 Ref. Accuracy Flow error at normal flow (250 scf/min) Ambient Temp. Static Press. Drift (Stability) 0.0% 2.0% 4.0% 6.0% 8.0% 10.0% 12.0% Flow Error CONCLUSION BEST PRACTICES For best safety and efficiency, users should: Select transmitters which, under the application conditions specified, respond at least as quickly as the compressor surge time. However, once the transmitters are fast enough, additional improvements do not provide additional value. Calculate and optimize installed repeatability, under the specified application conditions. This should allow the user to minimize unnecessary blowoff and/or recirculation, with no added surge risk, and/or to reduce maintenance and energy costs. Mark Menezes Page 7 of 8

REFERENCES 1. McMillan, G.K., Centrifugal and Axial Compressor Control, Instrument Society of America, Research Triangle Park, NC, 1983. 2. Botros, K.K., Henderson, J.F., Developments in Centrifugal Compressor Surge Control A Technology Assessment, Transactions of the ASME Journal of Turbomachinery, April 1994. 3. White, M.H., Surge Control for Centrifugal Compressors, Chemical Engineering, Dec. 1992. 4. Menezes, M., Calculating & Optimizing Repeatability of Natural Gas Flow Measurements, Pipeline & Gas Journal, July 2001. 5. The TPFE.xls spreadsheet calculates the repeatability/uncertainty contribution of the DP transmitter under user-specified application conditions, and is pre-loaded with performance specifications for a wide variety of transmitters from leading suppliers. See www.rosemount.com to obtain a copy. Mark Menezes Page 8 of 8