Accuracy and reliability of pulse oximetry in



Similar documents
More detailed background information and references can be found at the end of this guideline

Oxygenation and Oxygen Therapy Michael Billow, D.O.

NHS FORTH VALLEY Neonatal Oxygen Saturation Guideline

Why is prematurity a concern?

Hummi Micro Draw Blood Transfer Device. The Next Generation System for Closed Micro Blood Sampling in the Neonate

Pulmonary Diseases. Lung Disease: Pathophysiology, Medical and Exercise Programming. Overview of Pathophysiology

Screening for Critical Congenital Heart Disease in the Apparently Healthy Newborn

1.4.4 Oxyhemoglobin desaturation

Critical Care Therapy and Respiratory Care Section

The Sepsis Puzzle: Identification, Monitoring and Early Goal Directed Therapy

Ventilation Perfusion Relationships

The Heart Center Neonatology. Congenital Heart Disease Screening Program

Addendum to the NRP Provider Textbook 6 th Edition Recommendations for specific modifications in the Canadian context

CORD BLOOD COLLECTION / ANALYSIS- AT BIRTH

Extracorporeal Life Support Organization (ELSO) Guidelines for Neonatal Respiratory Failure

Medicare C/D Medical Coverage Policy

A8b. Resuscitation of a Term Infant with Meconium Staining. Session Summary. Session Objectives. References

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Understanding Stroke Volume Variation and Its Clinical Application

Cord Blood Erythropoietin and Markers of Fetal Hypoxia

CPT Pediatric Coding Updates The 2009 Current Procedural Terminology (CPT) codes are effective as of January 1, 2009.

Oxygen Saturation Monitoring by Pulse Oximetry


Determinants of Blood Oxygen Content Instructor s Guide

DME: Definition... 2 Life Sustaining DME... 3 Oxygen Use Policy... 4 Non-Life Sustaining DME... 7

MECHINICAL VENTILATION S. Kache, MD

Pulse Oximetry and the Oxyhemoglobin Dissociation Curve

Original Article Evaluation of Hemoglobin Concentration of Cord, Capillary and Venous sampling in Neonates

Safe Zone: CV PIP < 26; HFOV: MAP < 16; HFJV: MAP < 16 Dopamine infusion up to 20 mcg/kg/min Epinephrine infusion up to 0.1 mcg /kg/min.

Respiratory Care. A Life and Breath Career for You!

Perioperative Management of Patients with Obstructive Sleep Apnea. Kalpesh Ganatra,MD Diplomate, American Board of Sleep Medicine

The Advantages of Transcutaneous Co 2 Over End-Tidal Co 2 for Sleep Studies PETCo 2 vs. TCPCo 2

Signal Extraction Technology

Lothian Guideline for Domiciliary Oxygen Therapy Service for COPD

Premature Infant Care

TRANSPORT OF BLOOD GASES From The Lungs To The Tissues & Back

Guidelines for the Management of the Obstetrical Patient for the Certified Registered Nurse Anesthetist

Common Ventilator Management Issues

Understanding Hypoventilation and Its Treatment by Susan Agrawal

From AARC Protocol Committee; Subcommittee Adult Critical Care Version 1.0a (Sept., 2003), Subcommittee Chair, Susan P. Pilbeam

Children's Medical Services (CMS) Regional Perinatal Intensive Care Center (RPICC) Neonatal Extracorporeal Life Support (ECLS) Centers Questionnaire

University of Kansas. Respiratory Care Education

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor

PROCEDURAL SEDATION/ANALGESIA NCBON Position Statement for RN Practice

Evaluation and treatment of emphysema in a preterm infant

Critical Congenital Heart Disease (CCHD) Screening

Oxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*

Vtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs

NICU Level of Care Criteria

OET: Listening Part A: Influenza

Delayed Cord Clamping

*Reflex withdrawal from a painful stimulus is NOT considered a purposeful response.

Doppler Ultrasound in the Management of Fetal Growth Restriction Chukwuma I. Onyeije, M.D. Atlanta Perinatal Associates

Eileen Whitehead 2010 East Lancashire HC NHS Trust

2008 Coding Questions and Answers

Oxygen - update April 2009 OXG

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY

NRP 2012 Putting New Resuscitation Guidelines into Practice

Scope and Standards for Nurse Anesthesia Practice

HLTEN609B Practise in the respiratory nursing environment

Scope and Standards for Nurse Anesthesia Practice

Pulse Oximetry. Principles of oximetry

ETCO2 Monitoring: Riding the Wave! Disclosure 4/11/2013

Umbilical Cord Blood as Alternative for Infant Blood in Neonatal Sepsis Evaluation. Scott & White Children s Hospital

HEALTH EVIDENCE REVIEW COMMISSION (HERC) COVERAGE GUIDANCE: DIAGNOSIS OF SLEEP APNEA IN ADULTS DATE: 5/9/2013 HERC COVERAGE GUIDANCE

Oxygen Therapy. Oxygen therapy quick guide V3 July 2012.

Principle of oxygen therapy in the newborn

Corporate Medical Policy

Policy Name: Patient Monitoring via the Patient SafetyNet (PSN) Monitoring System

TRANSPORT OF CRITICALLY ILL PATIENTS

5/30/2014 OBJECTIVES THE ROLE OF A RESPIRATORY THERAPIST IN THE DELIVERY ROOM. Disclosure

Guidelines for Standards of Care for Patients with Acute Respiratory Failure on Mechanical Ventilatory Support

NEONATAL CLINICAL PRACTICE GUIDELINE

March 31, Etiometry, Inc. Richard Galgon Independent Consulting Associate Quintiles 5846 Cobblestone Lane Waunakee, Wisconsin 53597

I.O. Phd International Research Program

British Association of Perinatal Medicine. The Management of Babies born Extremely Preterm at less than 26 weeks of gestation

Brain Injury during Fetal-Neonatal Transition

Mechanical Ventilators

Advanced Monitoring Parameters 2015 Quick Guide to Hospital Coding, Coverage and Payment

Arterial Blood Gas Case Questions and Answers

How To Get On A Jet Plane

Institutional Handbook of Operating Procedures Policy

Fetal Responses to Reduced Oxygen Delivery

Airway Pressure Release Ventilation

Applications of Doppler Ultrasound in Fetal Growth Assessment. David Cole

Levels of Critical Care for Adult Patients

Pediatric Respiratory System: Basic Anatomy & Physiology. Jihad Zahraa Pediatric Intensivist Head of PICU, King Fahad Medical City

CRITICAL CARE MONITORING: WHAT, WHEN, AND HOW? Susan G. Hackner, BVSc.MRCVS.DACVIM.DACVECC.

SpO2 PULSE OXYMETER MD-300

Fetal Acid Base Status and Umbilical Cord Sampling. David Acker, MD

Chapter 1 Dissolved Oxygen in the Blood

Critical Care Paramedic Position Statement

Overall Goals/Objectives - Surgical Critical Care Residency Program The goal of the Pediatric Surgical Critical Care Residency program is to provide

RN Staffing in the Neonatal Intensive Care Unit

Home Oxygen Therapy Policy and Administration Manual. April Assistive Devices Program Ministry of Health and Long-Term Care

Transcription:

Accuracy and reliability of pulse oximetry in premature neonates with respiratory distress GINNY W. HENDERSON, CRNA, MS Concordville, Pennsylvania Continuous noninvasive monitoring of oxygenation in premature neonates with respiratory distress is essential to avoid the potential complications of hypoxemia and hyperoxia. The accuracy and reliability of pulse oximetry (using an Ohmeda Biox) was evaluated in 15 premature neonates. Pulse oximetry oxygen saturation readings closely approximated arterial oxygen saturation values analyzed by an IL 282 C O-Oximeter (Instrumentation Laboratory, Lexington, MA). Forty-five pooled data points were obtained, and analysis was performed by linear regression y = +1.19x -18.16, r = +0.87. There was no correlation between carboxyhemoglobin levels (range 3.2% to 9.9%) and the difference between pulse oximetry and arterial oxygen saturations. Ninety-five percent of the data points collected fell within the 85% to 95% saturation range. The correlation between pulse oximetry and arterial saturation found in the present study may not be generalizable to extremes in oxygen saturation in the premature neonate. This study demonstrates the accuracy and reliability of pulse oximetry within the 85% to 95% saturation range in premature infants with respiratory distress over a wide range of carboxyhemoglobin concentrations. Medical management of the premature neonate with respiratory disease has been improved by technology that allows continuous monitoring of arterial oxygenation. Administration of oxygen as a method of combating respiratory problems of the newborn has been documented in the literature as early as the 19th century. The unreliability of intermittent blood gas sampling, and the many complications from more invasive techniques of blood gas determinations, have resulted in the current emphasis on continuous noninvasive methods of blood gas monitoring. 1-4 Critically ill neonates will develop periods of life-threatening desaturation. The potential sequelae of hypoxemia in the neonate include increased pulmonary vascular resistance, persistent pulmonary hypertension, neurological impairment, intellectual deficits, respiratory compromise and, finally, circulatory collapse. However, the administration of oxygen to prematurely born neonates is not without hazard. The use of supplemental oxygen with these infants has been associated with an increased incidence of retinopathy of prematurity and bronchopulmonary dysplagia. Since the retinal vasculature does not mature until after birth at full term, the premature neonate is at risk for developing retinopathy of prematurity before the conceptual age of 44 weeks. The literature has documented cases of retinopathy of prematurity in preterm infants where the only supplemental oxygen received was during the course of a general anesthetic. 5,e Oximetry is a continuous noninvasive method of evaluating the oxygenation of arterial blood by measuring spectrophotometrically the percentage 224 Journal of the American Association of Nurse Anesthetists

of total hemoglobin saturated with oxygen. The technique is based on the known differences between the absorption spectra of reduced and oxygenated forms of hemoglobin according to Beer's Law: the concentration of an absorbing substance is proportional to the logarithm of light transmittance. As extinction coefficients for oxyhemoglobin and reduced hemoglobin are known constants at specific wavelengths, using two frequencies of light permits the determination of their respective concentrations. From these data, the arterial oxygenation saturation, defined as the ratio of oxyhemoglobin to total hemoglobin, can be calculated. In 1980, Yoshiya and his colleagues first published the idea of combining the techniques of photoplethysmography, which identifies arterial blood by waveform, with the concept of oximetry. 7 This combination of the two techniques allowed the determination of the oxygen saturation of arterial blood based on the principle that arterial blood pulsates while other components, such as venous blood and tissue, normally do not. The pulsating arterial bed, by expanding and relaxing, modulates the amount of light passing through the tissue. A measurement taken in the absence of a pulse is compared with a measurement taken in the presence of a pulse, thus correcting for factors such as venous blood and other tissue. This technology has come to be known as pulse oximetry. The recent availability of a soft, pliant neonatal probe has expanded the application of this continuous noninvasive monitoring technique to the pediatric population. Methodology This clinical study was conducted at the neonatal intensive care unit of the Medical College of Pennsylvania. Forty-five data points were collected from 15 premature infants after informed parental consent was obtained. To be included in the study, subjects had to have a previously inserted umbilical arterial line. Excluded were infants with a hematocrit below 30 to minimize the necessity of a blood transfusion. All subjects were preterm with a mean gestational age of 30 weeks (range 27 to 34 weeks by the Dubowitz scale) and mean birth weight of 1378 g (range 730 to 2050 g). All were studied during the first week of life. Thirteen infants survived. Thirteen infants had respiratory distress syndrome. In addition, four were diagnosed as having persistent pulmonary hypertension. One infant had a primary diagnosis of sepsis. One had pneumonia. Three of the infants required an oxyhood. The remaining 12 were treated by continuous positive airway pressure (CPAP), or intubated and mechanically ventilated (Table I). When dictated by the patient's condition, arterial blood gases were drawn from the indwelling arterial umbilical catheter into an airtight heparinized syringe. Samples were obtained when the infants were quiet or sleeping. Simultaneous pulse Table I Perinatal characteristics of infants in study Birth Gestational Primary Patient Sex weight (g) age (wk) diagnosis Respiratory support 1 M 730 29 RDS Assisted ventilation 2 M 1750 33 RDS Assisted ventilation, Oxyhood 3 M 1870 30 RDS Assisted ventilation 4 M 800 27 RDS Assisted ventilation, CPAP 5 M 850 27 RDS, PPH Assisted ventilation 6 M 1450 28 RDS, PPH Assisted ventilation 7 M 2050 32 RDS Assisted ventilation 8 M 1900 30 Sepsis Oxyhood, room air 9 M 1360 31 RDS, PPH Assisted ventilation, CPAP 10 M 870 29 RDS Room air 11 F 1200 30 RDS CPAP 12 M 1530 28 RDS Oxyhood 13 F 1700 32 RDS Assisted ventilation, CPAP 14 F 965 28 RDS Assisted ventilation 15 F 1640 34 Pneumonia Assisted ventilation RDS = Respiratory distress syndrome PPH = Persistent pulmonary hypertension June 19881 Vol. 56/No. 3 225

oximeter saturation readings and infant vital signs were recorded. Each blood sample was packed in ice and taken immediately to the pulmonary laboratory where actual arterial oxygen saturation was determined using an IL 282 CO-Oximeter which also measures the percentage of carboxyhemoglobin in the sample. Results A total of 45 paired pulse oximeter and arterial oxygen saturation measurements from 15 infants were collected. Each sample was treated as an independent observation. Arterial oxygen saturations ranged from 74.9% to 98.4% with a mean of 90.99% and a standard deviation of ± 4.40. Pulse oximeter oxygen saturation varied from 80% to 97% with a mean of 91.66% ±3.23% (Table II). Linear regression demonstrated a strong positive correlation between arterial and pulse oximetry oxygen saturations, producing r = +0.87 (p<.0001) (Figure 1). Carboxyhemoglobin levels ranged from 3.2% to 9.9% with a mean of 7.19% ±1.70%. There was no significant correlation between carboxyhemoglobin level and the difference between arterial and pulse oximeter oxygen saturation values, r = +0.12. Discussion Pulse oximetry and arterial blood gas oxygen saturation values as measured by an IL 282 CO- Oximeter were compared in preterm infants. The present study demonstrates a strong positive correlation between pulse oximetry and arterial oxygen saturation values (r = + 0.87) over a 75% to 98% saturation range. Time constraints limited data collection to 45 pooled data points from 15 premature neonates, 13 (86%) of whom had a primary diagnosis of respiratory distress syndrome (RDS). The correlation between pulse oximetry and arterial oxygen saturation (r = +0.87) in this study may not be generalizable to premature neonates with advanced cardiopulmonary involvement such as severe shunting, persistent pulmonary hypertension or low cardiac output with poor peripheral perfusion. Critically ill neonates will develop periods of life-threatening hypoxia. Most of the data points collected were clustered between 85% and 95% saturation as is consistent with clinically safe target range. The accuracy of pulse oximetry saturation values at less than 85% saturation cannot be deduced from this study. The difference between pulse oximetry and arterial oxygen saturation was analyzed as a function of blood carboxyhemoglobin concentration. No significant correlation was found (r = +0.12) between these variables despite carboxyhemoglobin levels of 3.2% to 9.9%. Oxygen tension rather than oxygen saturation value has traditionally guided the management of ventilation in the premature neonate. The oxyhemoglobin dissociation curve represents the relationship between a given oxygen tension and the percentage of hemoglobin in chemical combination with oxygen. The oxygen saturation of whole blood at a given oxygen tension is a reflection of many factors, the percentage of fetal hemoglobin and 2, 3-DPG red blood cell content being of primary importance. 8 Changes in temperature, ph, metabolic status and increased concentrations of dyshemoglobin also impact on the position of the oxyhemoglobin curve. In the present study, oxygen tension ranged from 35 mmhg to 109 mmhg with a mean of 67 mmhg. It is generally considered that a PO2 below 50 mmhg in the premature neonate suggests respiratory failure. The American Academy of Pediatrics suggests maintaining the premature neonate PaO 2 within the range for PaO 2 of normal newborns, which is 50 to 100 torr. 9 Table II Comparison between pulse oximeter oxygen saturation and arterial oxygen saturation Oxygen saturation mean SD Range P Arterial 90.99% ±4.40 74.9 to 98.4% Pulse oximeter 91.66% ± 3.23 80 to 97% Difference.67% 0 to 6.8% 0.05 n = 45 226 Journal of the American Association of Nurse Anesthetists

Research by Orzalesi et al. shows arterial oxygen saturation values in premature neonates. 10 Data collected during the first 40 days of life from 40 radiologically normal and clinically stable premature neonates breathing spontaneously on room air show arterial oxygen tensions between 51.6 mmhg and 94.2 mmhg corresponding to an oxygen saturation range of approximately 85% to 98%. In the present study, when oxygen saturation was between 90% and 96%, only one of the data points collected had a corresponding PaO 2 above 100 torr, with all other corresponding oxygen tension values falling within the range recommended by the American Academy of Pediatrics. Conclusion This study demonstrates the accuracy and reliability of pulse oximetry in premature infants in respiratory distress with oxygen saturation readings between 85% and 95%. Carboxyhemoglobin levels below 9.9% did not appear to influence the accuracy of pulse oximetry readings. While this study demonstrated a close correlation between pulse oximetry and arterial oxygen saturation in the premature infant, great caution should be ex- Figure 1 Comparison of oxygen saturation measured by pulse oximetry and oxygen saturation measured by IL 282 CO-Oximeter in simultaneously drawn arterial blood samples. 100 90 80 W\ 70 60 0 N 50 40 t J 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 PULSE OXIMETER SATURATION % Linear regression: y = + 1.19x-18.16, r = +0.87(p <.0001). June 1988/ Vol. 56/No. 3 227

ercised in attempting to generalize these findings to infants with extremes in saturation or those with cardiopulmonary involvement. The only reliable monitor of acceptable oxygenation in the premature neonate is the direct or indirect measurement of arterial oxygen tension or saturation. Invasive sampling of arterial blood is intermittent and not without sequelae. Continuous noninvasive monitoring of the premature neonate allows the clinician to detect and treat mild desaturation before clinical signs become apparent. Maintaining the premature neonate's oxygen saturation within the 90% to 95% saturation range corresponds to an oxygen tension range of 50 to 100 mmhg, and will limit the potential complications of hypoxemia and hyperoxia in the premature neonate. REFERENCES (1) Huch A, Huch R. 1976. Transcutaneous, noninvasive monitoring of PO 2. Hospital Practice. 11:43-52. (2) Peabody JL, Willis MM, Gregory GA, et al. 1978. Clinical limitations and advantages of transcutaneous oxygen electrodes. Acta Anaesthesiologica Scandinavica Suppl. 68:76-82. (3) Essop AR, Frolich J, Moosa MR et al. 1984. Risk factors related to bacterial contamination of indwelling vascular catheters in non-infected hosts. Intensive Care Medicine. 10:193-195. (4) Stavis RL, Krauss AN. 1980. Complications of neonatal intensive care. Clinics in Perinatology. 7:107-124. (5) Betts E, Downes J, Schaffer D, Johns R. 1977. Retrolental fibroplasia and oxygen administration during general anesthesia. Anesthesiology. 47:518-520. (6) Merritt J, Sprague D, Merritt W, Ellis R. 1981. Retrolental fibroplasia: a multifactorial disease. Anesthesia and Analgesia. 60:109-111. (7) Yoshiya I, Shimade Y, Tanaka R. 1980. Spectrophotometric monitoring of arterial oxygen saturation in the fingertip. Medical and Biological Engineering and Computing. 18:27-32. (8) Wilkinson AR, Phibbs RH, Heilbron DC et al. 1980. In vivo oxygen dissociation curves in transfused and untransfused newborns with cardiopulmonary disease. A mercan Review of Respiratory Disease. 122:629-634. (9) American Academy of Pediatrics Committee on Fetus and Newborn. 1983. Hospital Care of Newborn Infants: Standards and Recommendations. Evanston, American Academy of Pediatrics. 7th ed. (10) Orzalesi M, Mendicini M, Bucci G, et al. 1967. Arterial oxygen studies in premature newborns with and without mild respiratory disorders. Archives of Disease in Childhood. 42:174-180. AUTHOR Ginny W. Henderson, CRNA, MS, is currently a staff nurse anesthetist at Crozer-Chester Medical Center in Upland, Pennsylvania. She is a graduate of the Master of Science Program in Nurse Anesthesiology at the Medical College of Pennsylvania, Philadelphia. This article is adapted from her master's thesis. Her research was presented at the 54th Annual Metting and Professional Sessions of the AANA in Cincinnati. It was funded by a grant from the AANA Research and Education Foundation. ACKNOWLEDGEMENT The author wishes to extend her deepest appreciation to Alan Zubrow, MD, and Michael Booth, CRNA, MA, for their support and cooperation during the course of this study. 228 Journal of the American Associaion of Nurse Ansthetists