abc Control Processors New Infrared Linescanner Control Signal Processors instruments international



Similar documents
abc A new generation of intelligent compact digital infrared thermometers instruments international

Processor. Installation Guide

Batch Processor (LSC-B)

Processor. User Guide

PROCESSOR CONFIGURATION SOFTWARE USER GUIDE

Temperature & Humidity SMS Alert Controller

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Repeaters and Mimics Data Sheet

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Product Information Sheet UH36 Hi Pot Tester

NEW. EVEN MORE data acquisition and test stand automation

PIEZOMETER AIRFLOW MEASURING RING

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Intelligent Vibration Monitoring

MINIMAT-EC-Servo Screwdriver Spindles

Product Information Fire alarm panel 8000 C

4UHD. SDX-8x8. Flexible and comprehensive professional Digital Modular Matrix (DMM) for Commercial, Education and Residential

Continuous Thermal Monitoring to Minimise Slag Carry-Over in Steel Production. Slag Detection System

Product Information Sheet UH28CS-12kV Hi Pot Tester

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

DC Electronic Loads 8500 series

THE SAS AUDIO ROUTING SWITCHER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SMS GSM Alarm Messenger

Setup guide. point to point wall plate extenders

CAT5 Video Display Quick Installation Guide

40.3. Control Relays and Timers

Modular I/O System Analog and Digital Interface Modules

EDI Distributor Control Interface Wiring and Setup Instructions

Introduction to PROFIBUS and PROFINET

Remote Monitoring and REC 501 Control Unit Product Guide

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Programmable Controller G Series. New. Models

Application/Connection Examples

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

QuickSpecs. Models HP Server Console Switches

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Microcor Wireless Transmitter (MWT)

DVI DA2 and DVI DA 4 User Guide

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

ABB RTU560A Series CMU & Modules

PCS0100en Persy Control Services B.V. Netherlands

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Industrial Bar Code Scanners

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

AIS750 Series Alarm Annunciator

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

TX2123 RS485 TO ETHERNET ADAPTOR

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

NETWORK ENABLED EQUIPMENT MONITOR

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Quick Connect. quick - simple - efficient.

NC-12 Modbus Application

Bar code scanners CLV45x / CLV450 / Standard Density

UCC 1 USB-CAN CONVERTER

Residual Gas Analyzers

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

How To Make A Fronius Cl Power Inverter

Leading the way in digital KVM. KVM Solutions. for Broadcast & Post Production

UPS Network Interface. Quick InstallationGuide

In-Sight Hardware specifications

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

OZW30. Central Unit SYNERGYR

Barcode Reader Series BCL 31, BCL 32, BCL 34

Uninterruptible Power Supply

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Foxboro Evo Process Automation System

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Disturbance Recoder SPCR 8C27. Product Guide

Digital input modules

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

Chassis, Power Supply, and Element Management

200 Range Dialer Installation Manual. Version 1.0

connecdim Gateway G1 Ethernet TCP/IP to DALI

HWg-STE HWg-STE PoE MANUAL

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Multi-Range Programmable DC Power Supplies 9115 Series

applicomio Profibus-DP

TELECOM HF VHF UHF over IP

QSE-CI-NWK-E Control Interface

Remote Sources. Facility. Router

Transcription:

abc instruments international Control Processors New Infrared Linescanner Control Signal Processors

A new range of high precision Landscan Control signal processors providing the essential interface between the compact LSP range of high speed infrared linescanners, the LS range of precision, high temperature infrared linescanners and industrial process control computers. Benefits Improved product quality and operating profitability Closer control of heating and manufacturing processes Detect product defects and heating problems quickly Reduced set-up time and scrap rate Automated quality monitoring Features Choice of signal processing units to suit the application Choice of mounting arrangement Single cable connection between scanner and processor Powerful, versatile, software system with single and multiple channel digital/analog input and outputs Control Processors Landscan Control processors offer the user a wide choice of process monitoring and control options Choice of Control Processors There are three Landscan infrared linescanner Control signal processors in the range to choose from to suit your requirements: Landscan Control Compact LSC-C Landscan Control Rack LSC-R Landscan Control Batch LSC-B Landscan Control Compact (LSC-C) is a simple, economic back-of-panel mount, and Landscan Control Rack (LSC-R) and Batch (LSC-B) are both 19in rack mount. Typical Applications Choose the Landscan Control processor to best suit your application: Landscan Control Rack and Compact Continuous, linear, slow moving products, such as hot steel strip, galvanising/galvanneal and float glass Landscan Control Batch Discrete, linear and rotary products, such as thermoformed plastic sheet, automotive glass, fibre board, torpedo car protection Process Control The outputs from the LSP and LS linescanner heads are transmitted to a Landscan signal processor. The Control processor can be configured using the Landscan Configuration software supplied as part of the system. Once configured Landscan Control provides communications, by serial or connection, with the plant PLCs. Additional display, analysis and data storage functionality is provided by a PC server operating the Windows based Landscan Control and Analyse (WCA) software system. The new Landscan Control Batch LSC-B processor provides optional OPC communications. Refer to the Landscan Software brochure for further information on Landscan WCA.

Control Compact and Rack Linescan Signal Processors The output signal from the scanner head is converted into a data string of 1000 readings per scan line with a maximum frequency of 100 lines/second and is transmitted to a Landscan Control processor. The Landscan Control processor provides all the calculations required, such as zone output and alarms for each line. Landscan WCA software also provides further analysis, image display and data storage. The processors can communicate with the Landscan WCA software and at other computer levels using TCP/ IP protocol for process control purposes. Landscan setup software provides basic functionality to the Control processors for monitoring the scanner measurement parameters. Landscan Control Compact Landscan Control Compact LSC-C is an economic, single channel processor designed for linear measurement. LSC-C processors can incorporate an additional, optional DAIO board (digital/ analog input/output). The processors are designed to operate with all LSP scanner types, and provide the necessary power supplies, laser on/ off, external emissivity and internal ambient temperature control signals. Landscan Control Rack Landscan Control LSC-R is also a linear processor and has all of the functionality of the LSC-C, but has the optional addition of up to up 3 DAIO boards. Each DAIO board can generate up to 4 20mA outputs for zone temperatures and product position, and 4 relay outputs for temperature alarms. Two of the DAIO boards also handle analog (V/mA) or digital inputs for signals such as product speed, reference temperatures and signals from HMD s or other switches for product detection. LSC-R processors are also compatible with the LS range of linescanners. LS linescanners require a separate power supply (90 to 230V a.c.), and do not have built-in internal laser. However, the Landscan Control processors can supply the external scan speed signals. Typical Landscan WCA screen showing a simple profile with single control zone indicating temperature, history trace and 2D map Schematic Diagram Plant PC/PLC Laptop TCP/IP RS232C Landscan Control processor TCP/IP Landscan WCA software LSP linescanner Digital I/O Analog I/O TCP/IP or RS232C TCP/IP PC operating Landscan WCA

Control Batch Landscan Control Batch is an extremely powerful signal processor which can be configured specifically to suit the particular process control application Linear - the product passes in a straight line through the scanner head field Product - descrete, individual products Rotary - the product is rotating as it passes through the scanner field of view Landscan Control Batch Landscan Control Batch provides new additional product orientated functionality. LSC-B can detect the beginning and the end of a product and stores the measured data internally. LSC-B can calculate area temperatures, based on this two dimensional temperature array. This new functionality is particularly useful in industries such as: plastics thermoforming and glass tempering where the product is heated by a number of individual heaters; or in applications where the product needs temperature monitoring by areas. Additionally, the LSC-B can operate as an OPC server. All area or group temperature information is available for the heater control PC. The LSC-B can also interface with digital incremental encoders to correct the non linear image from rotary thermoforming machines into the original shape. LSC-B is able to take into account the machine acceleration, velocity and deceleration during the index. (The thermoforming industry brochure provides further information.) Heater Field Map The heater field map display shows a graphical representation of the current heater field configuration. The relative dimensions of the oven, product and individual heaters are set by the user and shown in the display. The user can map and configure individual heaters within a heater field, and can set high, low and average alarm trigger levels within a heater group. The heater field grid is overlaid on the temperature data for each detected product and statistical data is then calculated for each grid element. Above: Heater Field grid. Below: heater field grid overlayed on a typical Map Display Landscan Control Batch LSC-B 19in rack mount processor with multi-channel inputs/outputs for linear, rotary and discrete products Summary of Landscan Control Functions LSC-C LSC-R LSC-B Inputs: Scan valid, fast temperature Data structure: 1000 samples per line, up to 100 lines per second Processing format: One line at a time One line at a time; products up to 50,000 lines; processing time = 10% of product time Processing capability: Up to 14 user definable cross product zones Up to 500 user definable product (min, max, mean, high/low alarms) areas (min, max, mean, high/low alarms) Processor Configuration (Data display, Product Storage): Landscan Config software, Landscan WCA (multi-processor capability) Data outputs: Serial, TCP/IP Serial, TCP/IP, OPC (optional) Input ports: Single one client Dual up to 4 clients

XXX. XXX. XXX. XX LSC-R and LSC-B Dimensions All dimensions in mm/in 484/19.06 RS232C to remote PC and configuration software Configuration Switch 312/12.28 178/7.01 102/4.02 467.2/18.39 Diagnostics LED's View on LSC-R rear 450/17.72 Alarm Contacts Scanner Connections View on LSC-B rear Input/ Output Connection System Alarm Remote Laser Connection Scanner Connection DAIO Cards (optional, up to 3) connection RS232C connection Remote Laser Control Scan Valid Output Encoder Input RS232C Connection Scan Valid DAIO Cards LSC-C Dimensions 203/8.0 Configuration Switch 120/4.7 193/7.6 181/7.1 Diagnostics LEDs! RS232 RS232C Terminal Connection to remote PC running configuration software 302/12.0 TERMINAL IP ADDRESS 280/11.0 326/12.8 4 holes dia 6/0.2 Alarm Contacts Scan Valid Output View on base Remote Laser Control Connection RS232C Connection DAIO Card (LSC-C1 only) Scanner Connections All dimensions in mm/in

Processor Specifications LSC-C Compact LSC-R Rack LSC-B Batch Enclosure type: Panel/surface mount 19in rack mount Fast Temperature Input: Input error: 4 to 20mA input, linear <0.15 C (full range, 600 C/1112 F span) Scan valid input: Link selectable for LSP or LS types LSP scanners: RS485 LS scanners: - 5V single sided (2.5V ±20% threshold) Scan valid retransmission output: 5V ±20% Minimum load: 10kohms IATS display resolution: 1 C (range -10 to 90 C/14 to 194 F) Emissivity: 0.2 to 1.00 Current output error: Voltage input error: Current input error: System alarm: Laser On/Off (LSP only): <0.3% of span (0 to 20mA) max load 500ohms <0.2% of span <0.2% of span Relay contact, NO/NC 50V d.c., 500mA External contact Ambient operating temperature: 10 to 50 C/50 to 122 F Ambient temperature drift: Power requirement: <0.025% of reading per 10 C/50 F (all inputs/outputs) 100 to 240V 50/60Hz, 250W d.c. power output (LSP scanners): 24 ±1V d.c., 1.5A peak 31 ±1V d.c., 1.5A peak, 1A continuous 1A continuous Connections Scanner heads: Pheonix de-mountable plugs : RJ45 2x RJ45 Serial: D25 socket front mounted, D9 plug rear mounted Digital/analog inputs/outputs: D37 socket Maximum cable length Direct LSP scanner: 15m/49ft 150m/492ft Data only: 300m/984ft DAIO boards Processor Type Max No. Analog Digital Analog Digital DAIO boards Outputs (ma) Outputs Inputs (V/mA) Inputs Landscan Control Compact (LSC-C0) 0 - - - - Landscan Control Compact (LSC-C1) 1 4 4 4 4 Landscan Control Rack 3 12 12 8 8 Landscan Control Batch 3 12 12 8 8

Input/outputs Current Output: Analog Inputs: Digital Inputs: Digital Output: 0 to 20mA or 4 to 20mA, 500 Ohms max 0 to 20mA or voltage 1/2/5/10V d.c. Active high; 4V d.c. to isolated 0V Closed Contact; connected to isolated 24V Relay contact NO/NC, 50V d.c. max, 500mA Bi-directional Communications Communications standard: IEEE frame type Connection: Rear panel RJ 45 connector Cable type: 10 BASE-T/100 BASE-T Cat. 5UTP Transmission distance: 100m/328ft, with repeater 457m/1499ft Communication protocol: TCP/IP transfer rate: Auto-select 100M bits/s or 10M bits/s Serial Communications Type: RS 232C (3 wire) Connectors: 25 D-connector (setup - front panel), 9 D-connector (customer PLC rear) Baud Rate: 115200 (fixed) Ordering Information Processor Type Model No. No. of DAIO Boards Part No. Landscan Control Compact LSC-C0 0 092.677 Landscan Control Compact LSC-C1 1 800010 Landscan Control Rack LSC-R000 0 092.727 Landscan Control Rack LSC-R100 1 092.728 Landscan Control Rack LSC-R110 2 092.729 Landscan Control Rack LSC-R111 3 092.730 Landscan Control Batch LSC-B000 0 092.739 Landscan Control Batch LSC-B100 1 092.740 Landscan Control Batch LSC-B110 2 092.741 Landscan Control Batch LSC-B111 3 092.742 Landscan Control Batch-P LSC-B000-P 0 + Encoder Card 092.743 Landscan Control Batch-P LSC-B100-P 1 + Encoder Card 092.744 Landscan Control Batch-P LSC-B110-P 2 + Encoder Card 092.745 Landscan Control Batch-P LSC-B111-P 3 + Encoder Card 092.746 Optional Extras Sensors and Position Pack Connection for LSC-B-P Encoder Sensor Assembly 031.834 Digital Sensor Assembly 031.835 Position Pack Connection 031.850 Processor Upgrade Kit DAIO card upgrade 4 D/A out + 4 D/A in 031.788

For further information please contact the appropriate office or visit our web site at: www.landinst.com Land Instruments International Dronfield S18 1DJ, England Telephone: (01246) 417691 Facsimile: (01246) 410585 Email:infrared.sales@landinst.com Internet: www.landinst.com Land Instruments Sarl 7 Parc des Fontenelles 78870 Bailly, France Téléphone: (1) 34 62 05 45 Télécopie: (1) 30 56 51 12 Email: commercial@landinst.fr Internet: www.landinst.fr Land Instruments GmbH Fixheider Str. 6 51381 Leverkusen, Germany Telefon: 02171/7673-0 Telefax: 02171/7673-9 Email: infrarot@landinst.de Internet: www.landinst.de Land Instruments Srl Via dell'industria, 2 20037 Paderno Dugnano, Milano, Italy Telefono: 02/99040423 Telefax: 02/99040418 Email: info@landinst.it Internet: www.landinst.it Land Instruments Ltd 31-27 Toyotsuchou, Suita Osaka 564-0051, Japan Telephone: 06 6330 5153 Facsimile: 06 6330 5338 Email: info@landinst.jp Internet: www.landinst.jp Land Instruments International Av. Horacio 1132 Planta Baja "B" Col. Polanco 11550 Mexico, D.F. Telephone: 52 55 5281 1165 Facsimile: 52 55 5281 5364 Email: ventas@landinstruments.net Internet: www.landinstruments.net Land Instruments International Chile, 10-Edificio Madrid 92 28290 Las Matas, Madrid, Spain Telephone: 91 630 0791 Facsimile: 91 630 2918 Email: land-infrared@landinst.es Land Instruments International 10 Friends Lane Newtown, PA 18940-1804, USA Telephone: (215) 504-8000 Facsimile: (215) 504-0879 Email: irsales@landinstruments.net Internet: www.landinstruments.net Distributor: abc instruments international abc abcdefg Printed in England Continuous product development may make it necessary to change these details without notice. LSCP100/0505