4. THE USE OF INFRARED THERMAL IMAGING TO IDENTIFY GAS HYDRATE



Similar documents
Principle of Thermal Imaging

Calculation of Liquefied Natural Gas (LNG) Burning Rates

THERMAL RADIATION (THERM)

EXPLANATION OF WEATHER ELEMENTS AND VARIABLES FOR THE DAVIS VANTAGE PRO 2 MIDSTREAM WEATHER STATION

Introduction to Infrared Thermography. Jeff Beard IT 570

The Three Heat Transfer Modes in Reflow Soldering

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

Blackbody Radiation References INTRODUCTION

a) species of plants that require a relatively cool, moist environment tend to grow on poleward-facing slopes.

INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D

Standards A complete list of the standards covered by this lesson is included in the Appendix at the end of the lesson.

ABC PLAZA. For. ABC PROPERTY MANAGEMENT (Client)

Thermal Imaging Test Target THERMAKIN Manufacture and Test Standard

Commercial Vehicle Enforcement Branch THERMAL IMAGING

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

The Solubility of Calcium Carbonate

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov to Mar. 15, 2004.

Thermistor Basics. Application Note AN-TC11 Rev. A. May, 2013 Page 1 WHAT IS A THERMISTOR?

Every mathematician knows it is impossible to understand an elementary course in thermodynamics. ~V.I. Arnold

Convection in water (an almost-incompressible fluid)

Sample Liver Enzyme Lab

CHAPTER 2 Energy and Earth

The photoionization detector (PID) utilizes ultraviolet

CHAPTER 5 Lectures 10 & 11 Air Temperature and Air Temperature Cycles

ES 106 Laboratory # 2 HEAT AND TEMPERATURE

EVALUATION OF GEOTHERMAL ENERGY AS HEAT SOURCE OF DISTRICT HEATING SYSTEMS IN TIANJIN, CHINA

UNIT 1 GCSE PHYSICS Infrared Radiation 2011 FXA

Convection, Conduction & Radiation

Thermal Mass Availability for Cooling Data Centers during Power Shutdown

Radioactivity III: Measurement of Half Life.

Seasonal & Daily Temperatures. Seasons & Sun's Distance. Solstice & Equinox. Seasons & Solar Intensity

THE EFFECTS OF TEMPERATURE VARIATION ON SINGLE-LENS-REFLEX DIGITAL CAMERA CALIBRATION PARAMETERS

8.1 Radio Emission from Solar System objects

What Is Heat? What Is Heat?

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Hygro-Thermometer + InfraRed Thermometer Model RH101

UNIT 6a TEST REVIEW. 1. A weather instrument is shown below.

Cloud Radiation and the Law of Attraction

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

1. Theoretical background

Pressure. Curriculum for Excellence. Weather and Climate Cross-curricular project Section 2. Background Information:

ESCI 107/109 The Atmosphere Lesson 2 Solar and Terrestrial Radiation

Practical Application of Industrial Fiber Optic Sensing Systems

What are the controls for calcium carbonate distribution in marine sediments?

Trace Gas Exchange Measurements with Standard Infrared Analyzers

Take away concepts. What is Energy? Solar Energy. EM Radiation. Properties of waves. Solar Radiation Emission and Absorption

M O N T E R E Y B A Y A Q U A R I U M

RESULTS FROM A SIMPLE INFRARED CLOUD DETECTOR

FlairFlex. Real-time fluid logging and analysis service

Treasure Hunt. Lecture 2 How does Light Interact with the Environment? EMR Principles and Properties. EMR and Remote Sensing

High Temperature InfraRed Thermometer with Laser Pointer

Developing NDE Techniques for Large Cryogenic Tanks Year 2 Report

Infrared Thermometer Calibration A Complete Guide

Well-logging Correlation Analysis and correlation of well logs in Rio Grande do Norte basin wells

Solar Flux and Flux Density. Lecture 3: Global Energy Cycle. Solar Energy Incident On the Earth. Solar Flux Density Reaching Earth

APPLICATION OF THERMAL IR IMAGERY FOR CONCRETE BRIDGE INSPECTION

Case Studies: Infrared Heating in Industrial Applications

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Introduction to Fourier Transform Infrared Spectrometry

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

P3.8 INTEGRATING A DOPPLER SODAR WITH NUCLEAR POWER PLANT METEOROLOGICAL DATA. Thomas E. Bellinger

Radiation Transfer in Environmental Science

Cross-beam scanning system to detect slim objects. 100 mm in

BRSP-7 Page 1. A Open B Covered C Covered / Water. Two different experiments are presented, each experiment using a different pair of models:

Seasonal Temperature Variations

Can Gases Act Like a Greenhouse?

About Coffee and Refractometers Voice Systems Technology, Inc. (VST)

By Chris Gorman, PE M.ASCE PROBLEM:

Dual Laser InfraRed (IR) Thermometer

General Guidelines for Butt, Saddle, and Socket Fusion of Unlike Polyethylene Pipes and Fittings TN-13/2007

Owner s Manual

Light in the Greenhouse: How Much is Enough?

Experiment 3 Lenses and Images

Nondestructive Evaluation of USCG Hawkins Pt. Road Curtis Bay, MD Provided by: HurleyIR

GETTING TO THE CORE: THE LINK BETWEEN TEMPERATURE AND CARBON DIOXIDE

BB-18 Black Body High Vacuum System Technical Description

Systems Thinking and Modeling Climate Change Amy Pallant, Hee-Sun Lee, and Sarah Pryputniewicz

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

E/M Experiment: Electrons in a Magnetic Field.

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

Assessing Cloud Spatial and Vertical Distribution with Infrared Cloud Analyzer

Accurate Air Flow Measurement in Electronics Cooling

ENERGY & ENVIRONMENT

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Chem 131A: Absorbance of Riboflavin

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

This chapter discusses: 1. Definitions and causes of stable and unstable atmospheric air. 2. Processes that cause instability and cloud development

Dual Laser InfraRed (IR) Thermometer

POROUS BURNER - A New Approach to Infrared

Infrastructure & Cities Sector

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

The Precharge Calculator

Peltier Application Note

THE DETECTION OF GREENHOUSE GASES

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

Transcription:

D Hondt, S.L., Jørgensen, B.B., Miller, D.J., et al., 03 Proceedings of the Ocean Drilling Program, Initial Reports Volume 1 4. THE USE OF INFRARED THERMAL IMAGING TO IDENTIFY GAS HYDRATE IN SEDIMENT CORES 1 Kathryn H. Ford, 2 Thomas H. Naehr, 3 C. Gregory Skilbeck, 4 and the Leg 1 Scientific Party 5 ABSTRACT An infrared thermal imaging camera was used to image sediment cores on the catwalk, immediately following coring and prior to processing. The camera was used to identify negative temperature anomalies. These were investigated for their utility in identifying gas hydrate prior to dissociation, which occurs rapidly because of the temperature increase and pressure decrease associated with the coring process. The camera was successful in identifying distinct negative temperature anomalies in intervals of gas hydrate. The methodology requires some modification to improve efficiency but holds great potential to investigate thermal properties of sediments and rapidly identify gas hydrate. INTRODUCTION The identification of gas hydrate in sediment cores is of great interest for the study of hydrate distribution in sedimentary sequences, as well as for the detection and sampling of individual gas hydrate occurrences after core recovery. Since hydrate is stable only in high-pressure and low-temperature environments, it dissociates rapidly as cores undergo depressurization and heating during wireline recovery. As this dissociation is an endothermic process, sediment containing hydrate is cooled relative to the surrounding sediment, thus creating a negative temperature anomaly. Previously employed methods for the identification of this thermal anomaly included tactile methods and the use of ther- 1 Ford, K.H., Naehr, T.H., Skilbeck, C.G., and the Leg 1 Scientific Party, 03. The use of infrared thermal imaging to identify gas hydrate in sediment cores. In D Hondt, S.L., Jørgensen, B.B., Miller, D.J., et al. (Eds.), Proc. ODP, Init. Repts., 1, 1 [Online]. Available from World Wide Web: <http://www-odp.tamu.edu/ publications/1_ir/volume/ CHAPTERS/IR1_04.PDF>. [Cited YYYY-MM-DD]. 2 Graduate School of Oceanography, University of Rhode Island, South Ferry Road, Narragansett RI 02882, USA. khford@gso.uri.edu 3 Department of Physical and Life Sciences, Texas A&M University Corpus Christi, 6300 Ocean Drive, Corpus Christi TX 78412, USA. 4 Department of Environmental Sciences, University of Technology, Sydney, 1 Broadway, Sydney NSW 07, Australia. 5 Shipboard Scientific Party addresses. Ms 1IR-104

CHAPTER 4, INFRARED THERMAL IMAGING 2 mistor arrays (Paull, Matsumoto, Wallace, et al., 1996). However, tactile methods are nonquantitative and thermistor arrays do not provide rapid continuous records of entire cores. Therefore, an infrared (IR) thermal imaging camera was introduced during Leg 1 to scan core liners for thermal anomalies immediately after core recovery. Infrared radiation (~0.750 350 µm) is emitted by all objects as a function of their temperature. As the temperature of an object decreases, the wavelength of maximum emission increases. For hydrate, longwave infrared (8 12 µm) is the focus. The amount of thermal radiation emitted by an object is dependent upon the emissivity and temperature of the object (Stefan-Boltzmann Law). Emissivity is basically an efficiency factor. An object with an emissivity of 1 is a very efficient energy emitter (or absorber) and is known as a blackbody. In addition to emitting, an object can also reflect or transmit infrared radiation. Kirchhoff s Law states that the total infrared radiation leaving the surface of an object is a combination of emitted radiation (from the object itself), reflected radiation (the object reflects infrared radiation from another source), and transmitted radiation (the amount of infrared radiation coming through the object from another source). For example, a perfect infrared mirror would have an emissivity and transmissivity of 0. In contrast, a perfect infrared window would have an emissivity and reflectivity of 0. For examining relative temperatures, it is important to maintain the same values for these characteristics for each analysis. When examining absolute temperatures, determining the emissivity, transmissivity, and reflectivity of an object is critical. Establishing these parameters was the first step in the development of the infrared camera core scan method. The impact of air temperatures and scanning operators was studied to ensure that time of day or slightly different scanning methods did not impact measured core liner temperatures. The ultimate goal was to establish a procedure with which hydrate could be identified in cores on the catwalk as quickly and reliably as possible. Toward that end, results from nonhydrate-bearing cores and hydrate bearing cores are presented. METHODS The camera used during Leg 1 was a ThermaCam SC 00 camera, made by FLIR Systems. This camera measures temperatures from 40 C to +1500 C. For onboard application, it was set to record a range of temperatures from 40 C to +1 C (range 1). The precision of this camera is 0.1 C at 30 C and the accuracy is ±2 C. However, emissivity corrections can improve the accuracy to 0.0 C (R. Rogers, pers. comm., 02 [N1]). In order to achieve the most accurate temperature measurements, the emissivity of the core liner was established by placing a piece of electrical tape (with a known emissivity of 0.95) on the core liner. The apparent temperatures of the tape and the core liner were compared, and the emissivity of the core liner was determined to be 0.95 (tape was not visible on the core liner with the IR camera). Polycarbonate tubing is opaque to infrared radiation, so the remaining radiation was attributed to reflection. All analyses were conducted with the emissivity set at 0.95. The camera was mounted on a wheeled cart (Fig. F1) to maintain constant distance between the camera and core liner and rolled across each core before any other sampling was conducted on the catwalk. A dedicated lap-top computer recorded the camera images at a rate of 5 frames/s. An external screen attached to the camera showed a range of F1. Infrared camera, p. 8.

CHAPTER 4, INFRARED THERMAL IMAGING 3 temperatures from 15 to 25 C. This allowed immediate identification of cold spots, which were then visually and/or chemically inspected for evidence of hydrate. A depth scale was established in order to correlate the hydrate identified by the camera with other physical properties, chemical properties, and visual observations of hydrate. This was done by assigning the curated depth to the first image, then dividing the total core length by the number of images. Then a depth was incrementally assigned to each image. There were typically 0 300 images for each core. The images were analyzed with FLIR ThermaCam Researcher software. An analysis box was hand selected in the first image of the sequence file and was placed to avoid areas of significant reflection or other interference. The sequence file was played from beginning to end, and the maximum, minimum, and average temperatures from the analysis box were extracted from each image. All temperatures presented are minimum temperatures to highlight negative temperature anomalies. Further details of camera setup and data analysis procedures are available in Infrared Thermal Imaging, p. 42, in Physical Properties in the Explanatory Notes chapter. Scans at Sites 1226 and 1230 were used for comparison between a nonhydrate-bearing site and a hydrate-bearing site, respectively. Air Temperatures Air temperature data were recorded by the officers of the ship s bridge every 4 hr. The thermometer was located in a weather box adjacent to the bridge, ~50 ft away from the catwalk where the cores were imaged. F2. Air temperatures compared to core liner temperatures, p. 9. A B Core temperature ( C) Core temperature ( C) Site 1230 21 19 17 R 2 = 0.0995 15 24.5 25.0 25.5 26.0 26.5 27.0 27.5 23 22 21 19 17 Site 1226 R 2 = 0.0025 15 25.8 26.0 26.2 26.4 26.6 26.8 27.0 27.2 Air temperature ( C) F3. Time of day and watch compared to core liner temperatures, p. 10. A 24 Night watch Site 1226 Day watch 22 RESULTS AND DISCUSSION Air Temperatures vs. Core Liner Temperatures The air temperature taken at the bridge closest to the time the core was on deck was compared to the average core liner temperature for the core (Fig. F2). In addition, comparisons of day and night and camera operators (noon to midnight vs. midnight to noon watches) were conducted to determine a possible sampling bias (Fig. F3). No correlations were found. Core liner temperatures from top to bottom of the 10-m cores were examined to investigate any effect (particularly warming) associated with the method of scanning or the time elapsed during the scan (~1 min). Ten scans (five each from Sites 1226 and 1230) were randomly selected and compared. No consistent warming of the cores was observed (Fig. F4). Hydrate Identification The first independent evidence of gas hydrate at Site 1230 was visual observation of fizzing sediment (small white bubbles) interpreted to be decomposing hydrate in Section 1-1230A-15H-5; 123.5 meters below sea floor (mbsf). A subsequent review of the IR scan for that core revealed that core liner temperatures of the fizzing section were only a few degrees cooler (average = 4 C cooler) than the surrounding sediment (Table T1). Based on this observation, camera span and level were set so that the 15 to 25 C range was visible, which simplified the subsequent identification of cold spots caused by gas hydrate dissociation. B Temperature ( C) Temperature ( C) 14 12 10 24 22 14 12 10 Night watch Site 1230 R 2 = 0.02 0 400 800 10 00 00 2400 0 400 800 10 00 00 2400 Time (hr) Hole 1226B R 2 = 0.01 Day watch F4. Core liner temperatures for five cores, p. 11. A B Temperature ( C) Temperature ( C) 23 22 21 19 17 15 14 23 22 21 19 17 15 14 0 0 2 2 4 4 Hole 1230A Distance along core (m) T1. Core liner temperatures with hydrate and surrounding sediments, p.. 6 6 8 8 10 10 4H 15H 17H 30X 35X 8H 9H 13H 15H 27H

12 22 12 22 12 22 12 22 12 22 12 22 72 78 88 98 158.5 244 74 76 78 80 82 84 0 40 80 1 0 0 240 280 80 82 84 86 88 90 12 14 22 24 Core-liner temperature ( C) 0 Base of drill pipe 89 90 91 92 93 94 95 96 97 98 Wireline 100 102 104 106 108 110 1 2 3 1400 00 20 2600 Resistivity (Ωm) Discrete measurements Base of drill pipe Wireline P-wave velocity (m/s) 159.0 159.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 246 248 250 252 254 256 10 30 40 50 Base of drill pipe MST NGR MST (cps) Wireline 0 40 60 80 Wireline units (gapi) I II IA IB IC ID K.H. FORD ET AL. CHAPTER 4, INFRARED THERMAL IMAGING 4 Cold spots were first identified with the camera and then visually confirmed to be hydrate nodules or fizzing sediment in Cores 1-1230A- 26H and 1230B-12H. Figure F5 illustrates the thermal contrast between an interval of fizzing sediment and the surrounding sediment. A thorough examination of the downcore temperature plots revealed a greater variability in cores with hydrate nodules or fizzing sediment. Figure F6 illustrates the difference between cores that did not contain hydrate and cores that did contain hydrate or fizzing sediment. The standard deviation of the minimum temperatures in hydrate-bearing cores are generally >1 C, whereas in nonhydrate-bearing cores it is usually <1 C (Table T2). This can be explained by the contrast between low temperatures in the hydrate-bearing sediments and high temperatures typical of associated gas expansion voids (voids warm to ambient temperatures rapidly). This is not a fixed rule, however, and emphasizes the current need for careful core-by-core interpretation of both the thermal plots and the original image files. Although visual confirmation of hydrate is necessary for positive identification, careful analysis of the downcore temperature plots and thermal images suggest other hydrate occurrences at Site 1230 in Cores 1-1230A-11H, 13H, 21H, and 35X and 1-1230B-11H (Figure F7; see also Appendix, p. 7). Hopefully, developments will be made in the future to normalize core temperatures for the wireline trip, allowing confirmation of in situ temperatures and presence of hydrate using thermal imaging data alone. Comparison with Other Physical Property Measurements To conduct a comparison of the thermal data with other physical property measurements, composite downhole plots were generated. The curated depths of the two hydrate nodule occurrences and three intervals of fizzing sediment observed at Site 1230 were compared to the depths assigned based on the thermal image analyses (Table T1). Although imperfect, the two depth scales are comparable, suggesting that the thermal image depths may be useful for the generation of composite downhole plots. Resistivity, P-wave velocity, natural gamma ray (NGR) emission, and core liner temperature all illustrate increasing variability between ~80 and 5 mbsf (Fig. F8). The dissociation of hydrate with increased temperature and decreased pressure alters the core by altering the water content of surrounding sediments and creates gas expansion voids. This results in depth discrepancies between downhole log (wireline) data and shipboard measurements. However, although centimeter-scale correlation is not yet feasible, zones of identified and potential hydrate occurrence are recognizable. These correlations are more fully investigated in Physical Properties, p. 22, in the Site 1230 chapter. Interestingly, the thermal data from Site 1226 also show a correlation with other physical property measurements (Fig. F9). This could be explained by differential warming of distinct lithologies during wireline recovery. F5. Thermal contrast between hydrate and surrounding sediment, p. 12. A Depth (mbsf) 22.8 C 22 15.8 C F6. Temperatures of cores without and with hydrate, p. 13. 10 15 25 10 15 25 10 15 25 10 15 25 10 15 25 156 310 129 8.0 6.2 157 311 8.5 6.4 130 158 312 159 9.0 6.6 131 0 313 9.5 6.8 1 314 132 170.0 7.0 2 315 133 3 170.5 7.2 3 4 134 171.0 7.4 5 317 6 3 135 171.5 7.6 1-1226B-H 1-1226B-34X 1-1230A-17H 1-1230A-22H 1-1230A-27H Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) T2. Average and standard deviation of core liner temperatures, p. 19. F7. Thermal signatures suggestive of hydrate, p. 15. Depth (mbsf) Depth (mbsf) 1-1230B-11H 1-1230A-11H 1-1230A-12H 1-1230A-13H 1-1230A-21H 1-1230A-35X Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) F8. Comparison of thermal data with physical property measurements, Hole 1230A, p.. Unit Subunit PROBLEMS AND FUTURE WORK Although we have shown that the IR camera can be a valuable tool for rapid gas hydrate identification, there are several issues that need to

CHAPTER 4, INFRARED THERMAL IMAGING 5 be addressed in order to make the transition from a mainly qualitative tool to a more quantitative method. 1. Core handling times and catwalk temperature need to be monitored more carefully than was possible during Leg 1. The times to be measured include the wireline trip time and the time it takes to extract the core liner from the barrel, move it to the catwalk, and run the thermal scan. Whereas we have illustrated that scan times did not affect the core liner temperature distribution, the wireline trip does, and it has been suggested that core handling procedures can significantly affect the core temperatures (M. Storms and T. Bronk, unpubl. data [N2]). This is particularly important for hydrate and microbiological sampling, which are very temperature sensitive. Additionally, examining air temperatures at the time of scanning (rather than depending on the bridge s 4-hr measurements) would conclusively confirm a lack of sampling bias associated with air temperature. 2. A track is needed to run the camera along the core at constant speed. This will greatly facilitate depth calculation and correlation of the temperature data to other physical property data. The use of a track might also reduce problems with focusing and with reflections caused by the curvature of the core liner. If the camera were run across the core at a constant angle relative to the core, possible reflections would at least remain constant as well. 3. The use of the image analysis software needs to be standardized to avoid user-dependent biases during data analysis. It is also integral to increase the efficiency of the analyses. 4. Emissivity differences of different sediment types need to be taken into consideration. This will be especially important for temperature scans of split-core surfaces to examine hydrate distribution, since emissivity differences of various sediment types will significantly influence the absolute temperature readings of the camera. F9. Comparison of thermal data with MST measurements, Hole 1226B, p. 17. Depth (mbsf) 0 50 100 150 0 250 300 350 400 10 14 22 26 0.60 1.00 1.40 1.80 1500 00 1700 Density (g/cm 3 ) Core-liner temperature ( C) P-wave velocity (m/s) Unit Subunit I II IA IB IC ID Despite the need for improvement, thermal imaging has proven to be a successful method for gas hydrate identification in sediment cores. This method has great potential for becoming a valuable tool for gas hydrate identification and quantification in the future. ACKNOWLEDGMENTS The authors would like to acknowledge Glen Gettemy, Steve D Hondt, and the rest of the Leg 1 Shipboard Scientific Party for useful discussions and help in the development of this method. We would also like to thank Kim Bracchi and Steve Tran for many long hours setting up and running the camera. Special thanks to Frank Rack for providing the camera and essential precruise training. The paper also benefited from the input of Jay Miller, Gerardo Iturrino, and an anonymous reviewer. This research used samples and data provided by the Ocean Drilling Program (ODP). The ODP is sponsored by the U.S. National Science Foundation (NSF) and participating countries under management of Joint Oceanographic Institutions (JOI), Inc.

CHAPTER 4, INFRARED THERMAL IMAGING 6 REFERENCES Paull, C.K., Matsumoto, R., Wallace, P.J., et al., 1996. Proc. ODP Init. Repts. 4: College Station, TX (Ocean Drilling Program).

CHAPTER 4, INFRARED THERMAL IMAGING 7 APPENDIX Specific Depths of Known and Hypothesized Hydrate Occurrences Core, section Top of sample depth (mbsf) IR camera depth (mbsf) Comments 1-1230B- 11H 80.08 11H 80.80 12H-2 81.54 81.76 Foliated hydrate nodule 12H 82.38 1-1230A- 11H 84.41 1-1230B- 12H 85.31 12H 86.62 12H 88.58 1-1230A- 12H 92.74 13H 103.35 15H 1.55 15H 121.34 15H-5 123.47 123.37 Fizzing sediment H-3 141.80 141.90 Fizzing sediment 19H-1 148.30 148.57 Hydrate nodule 19H 149.32 19H 149.70 19H 150.00 21H 158.93 21H 0.36 21H 1.42 26H-2 199.91 199.58 Fizzing sediment 26H 0.10 35X 252.38 Note: IR = infrared.

CHAPTER 4, INFRARED THERMAL IMAGING 8 Figure F1. Infrared camera on wheeled cart for rolling down cores on catwalk prior to other sampling. A cardboard box was extended from the lens to the core liner and covered with reflective aluminum foil to shield external infrared radiation from the core.

CHAPTER 4, INFRARED THERMAL IMAGING 9 Figure F2. Air temperatures compared to core liner average temperatures. A. Site 1226. B. Site 1230. No sampling bias was found. A Core temperature ( C) 21 19 17 Site 1230 R 2 = 0.0995 15 24.5 25.0 25.5 26.0 26.5 27.0 27.5 B Core temperature ( C) Site 1226 23 22 21 19 17 R 2 = 0.0025 15 25.8 26.0 26.2 26.4 26.6 26.8 27.0 27.2 Air temperature ( C)

CHAPTER 4, INFRARED THERMAL IMAGING 10 Figure F3. Time of day and watch compared to core liner average temperatures. Nighttime (00 0700 hr) is shaded. Night watch and day watch are indicated at the top and divided with the dotted line. A. Site 1226. Average daytime core temperature =.73 ± 1.26 C, and average nighttime core temperature =.05 ± 1.47 C. Average day watch core temperature =.50 ± 0.93 C, and average night watch core temperature =.28 ± 1.76 C. B. Site 1230. Average daytime core temperature =.22 ± 1.46 C, and average nighttime core temperature =.29 ± 1.15 C. Average day watch core temperature = 17.88 ± 1.26 C, and average night watch core temperature =.59 ± 1.28 C. No sampling bias was found. A Site 1226 24 22 Night watch Day watch Temperature ( C) Temperature ( C) B 14 12 10 24 22 14 12 10 R 2 = 0.02 0 400 800 10 00 00 2400 Site 1230 Night watch Day watch R 2 = 0.01 0 400 800 10 00 00 2400 Time (hr)

CHAPTER 4, INFRARED THERMAL IMAGING 11 Figure F4. Trends in core liner temperatures for five randomly selected cores from (A) Site 1226 and (B) Site 1230. R 2 values for Site 1226 range from 0.002 to 0.3. R 2 values for Site 1230 range from 0.01 to 0.5. No consistent downcore trend is seen. Scan method and time do not have an effect on measured core liner temperatures. A Temperature ( C) Temperature ( C) B 23 22 21 19 17 15 14 23 22 21 19 17 0 2 Hole 1226B 4 6 Hole 1230A 8 10 4H 15H 17H 30X 35X 8H 9H 13H 15H 27H 15 14 0 2 4 6 8 10 Distance along core (m)

CHAPTER 4, INFRARED THERMAL IMAGING 12 Figure F5. Thermal contrast of core surface between fizzing sediment found in Core 1-1230A-26H and surrounding sediment. Note the clear visual contrast in image despite a <4 C temperature range. Length of core pictured is ~ cm. 22.8 C 22 15.8 C

Figure F6. Comparison of downcore plots of temperatures of cores without hydrate and with hydrate. A. Cores without hydrate. Visually confirmed hydrate nodule or fizzing sediment occurrences are identified with arrows and description of observation. Possible hydrate occurrences are circled. (Continued on next page.) A Depth (mbsf) 1-1226B-H 1-1226B-34X 1-1230A-17H 1-1230A-22H 1-1230A-27H Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) 10 15 25 10 15 25 10 15 25 10 15 25 10 15 25 156 310 129 8.0 6.2 157 158 159 0 1 2 3 4 5 6 311 312 313 314 315 3 317 3 130 131 132 133 134 135 8.5 9.0 9.5 170.0 170.5 171.0 171.5 6.4 6.6 6.8 7.0 7.2 7.4 7.6 K.H. FORD ET AL. CHAPTER 4, INFRARED THERMAL IMAGING 13

Figure F6 (continued). B. Cores with hydrate. B Depth (mbsf) 1-1230B-12H 1-1230A-15H 1-1230A-H 1-1230A-19H 1-1230A-26H Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) 10 15 25 10 15 25 10 15 25 10 15 25 10 15 25 81 117 138 148 198.5 82 nodule nodule 119 139 83 149 140 84 121 85 141 150 199.5 fizz fizz fizz 123 86 142 125 87 151 143 88 127 89 144 152 0.5 K.H. FORD ET AL. CHAPTER 4, INFRARED THERMAL IMAGING 14

Figure F7. Cores with thermal signatures suggestive of hydrate. Possible hydrate occurrences are circled. Depth (mbsf) 1-1230B-11H 1-1230A-11H 1-1230A-12H 1-1230A-13H 1-1230A-21H 1-1230A-35X Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) Temperature ( C) 12 22 12 22 12 22 12 22 12 22 12 22 72 78 88 98 158.5 244 74 76 78 80 82 84 80 82 84 86 88 90 89 90 91 92 93 94 95 96 97 98 100 102 104 106 108 110 159.0 159.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 246 248 250 252 254 256 K.H. FORD ET AL. CHAPTER 4, INFRARED THERMAL IMAGING 15

Figure F8. Comparison of thermal data with other physical property measurements for Hole 1230A. + = fizzing sediments, solid circles = hydrate nodules. = hypothesized hydrates. The shaded region represents the hypothesized hydrate zone. NGR = natural gamma radiation, MST = multisensor track. Depth (mbsf) 0 40 80 1 0 0 240 280 12 14 22 24 Core-liner temperature ( C) 0 Base of drill pipe Wireline Discrete measurements Base of drill pipe Wireline 1 2 3 1400 00 20 2600 Resistivity (Ωm) P-wave velocity (m/s) 10 30 40 50 Base of drill pipe MST NGR MST (cps) Wireline 0 40 60 80 Wireline units (gapi) Unit Subunit I II IA IB IC ID K.H. FORD ET AL. CHAPTER 4, INFRARED THERMAL IMAGING

CHAPTER 4, INFRARED THERMAL IMAGING 17 Figure F9. Comparison of thermal data with multisensor track physical property measurements for Hole 1226B. Similar overall trends are seen and highlighted with shaded regions. 0 Unit Subunit IA 50 IB 100 Depth (mbsf) 150 0 250 I IC 300 ID 350 400 II 10 14 22 26 Core-liner temperature ( C) 0.60 1.00 1.40 1.80 Density (g/cm 3 ) 1500 00 1700 P-wave velocity (m/s)

CHAPTER 4, INFRARED THERMAL IMAGING Table T1. Comparison of core liner temperatures, curated depth, and depth assigned based on infrared thermal image processing for intervals containing hydrate nodules or fizzing sediment. Core, section Observation Core liner temperature ( C)* Ambient liner temperature ( C) T ( C) Depth (mbsf) IR camera depth (mbsf) Depth (cm) 1-1230B- 12H-2 Foliated nodule 13.2 17.55 4.35 81.54 81.76 +22 1-1230A- 15H-5 Fizzing sediment 17 19.48 2.48 123.47 123.37 10 H-3 Fizzing sediment 15.4 19.73 4.33 141.8 141.9 +10 19H-1 Nodule.6 22.08 5.48 148.3 148.57 +27 26H-2 Fizzing sediment 15.5 19.01 3.51 199.91 199.58 33 Average: 4.03 Notes: * = core liner temperature measured at the location of hydrate or fizzing sediment. = average temperature of the core liner adjacent to the hydrate-bearing or fizzing sediment interval. IR = infrared.

CHAPTER 4, INFRARED THERMAL IMAGING 19 Table T2. Average and standard deviation of core liner temperatures. Core Core top depth (mbsf) Average core temp ( C)* Standard deviation ( C) Core Core top depth (mbsf) Average core temp ( C)* Standard deviation ( C) 1-1226B- 1H 0.0 19.76 0.51 4H 23.4.37 0.69 5H 32.9.02 0.48 6H 42.4 13.80 0.80 7H 51.9.13 0.52 8H 61.4.97 0.75 9H 70.9 17.42 0.69 11H 89.9.51 0.17 12H 99.4 17.08 0.92 13H 108.9.93 0.31 15H 127.9 19.28 0.28 H 137.4 17.26 0.39 17H 146.9.53 0.30 H 156.4.01 0.21 19H 5.9.89 0.56 H 175.4.93 0.64 21H 4.9.67 0.86 22H 194.4 19.38 0.32 23H 3.9 19.69 0.30 24H 213.4 19.64 0.25 25H 222.9.76 0.29 26H 232.4.27 0.61 27H 242.4 19.99 0.85 30X 271.9.64 0.34 31X 281.5 19.52 0.35 32X 290.8.35 0.59 33X 300.5 17.31 0.39 34X 310.2 17.82 0.96 35X 319.8.24 0.28 36X 329.4 17.05 0.24 37X 339.0 19. 0.29 38X 348.7.44 0.52 39X 358.4.41 0.66 40X 368.1 17.78 0.55 41X 371.1 17.94 0.43 43X 380.0 21.95 0.85 45X 397.2 19.84 0.92 46X 406.8.92 0.74 47X 4.4 19.47 0.61 1-1230A- 1H 0.0.91 0.38 5H 33.3.59 0.46 1-1230B- 6H 33.5.02 0.36 1-1230A- 6H 42.8.91 0.38 1-1230B- 7H 43.0.17 0.53 8H 52.5.85 0.28 1-1230A- 8H 54.3 19.70 0.47 9H 60.8.10 0.31 10H 70.3 19.82 1.54 1-1230B- 11H 73.5.03 0.88 1-1230A- 11H 79.8 17.30 1.24 1-1230B- 12H 81.0 15.64 1.12 1-1230A- 12H 89.3.60 0.96 1-1230B- 13H 90.5.72 0.99 1-1230A- 13H 98.8.28 0.68 14H 108.3.07 0.62 15H 117.8.59 0.84 17H 129.3 17.42 0.37 H 138.8 19.01 0.97 19H 148.3.59 2.05 21H 158.8.42 1.56 22H 8.3.05 0.35 26H 198.8.35 0.82 27H 6.3 19.19 0.43 31X 229.6. 0.41 35X 245.0.57 1.27 38X 267.2 17.76 0.44 Notes: * = ~0 images along the length of each core were analyzed for minimum temperatures. The image minimum temperatures were then averaged. = hydrate observed. = fizzing sediment (disseminated hydrate inferred).

CHAPTER 4, INFRARED THERMAL IMAGING CHAPTER NOTES* N1. Rogers, R., 02. FLIR Systems, Infrared Training Center, Billerica MA. Pers. comm. N2. Storms, M., and Bronk, T., 01. Leg 198 core warming analysis at Hole 19B. Unpubl. ODP Engineer s Notes.