Electrical Drawings for simplified KX city panels Contact: Dipl.-Ing. utz Steiner KX Association cvba Belgium Phone: +4961557029581 Mobil: +491638899639 Email: lutz.steiner@knx.org OTE: - These electrical drawings describe the neccessary electrical installations for the KX city panels - The electrical installations may only be carried out by professional electricians. - The KX Association cvba takes no responsibility for the topicality, correctness, completeness or quality of the information provided in this document. iability claims against KX Associaiton, which refer to material or immaterial nature caused by use or disuse of the presented information or by the use of faulty and incomplete information are excluded. Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 1 v. Fax: +3226755028 Ang.-r.:
egend ED Electrical Installation Flush mounted ED insert, power module 3 Triple outlet ED orientation light with pictogram arrow Single outlet ighting tube KX Rotary switch including KX universal interface KX push button, 1 gang, including KX universal interface OTE: - Any EDs can be used for the Building and Energy Generation panel - The EDs for the Energy Generation panel should contain arrow pictograms - The lighting tubes are conventional lighting tubes e.g. for christmas - Any KX switches from any KX manufactures can be used for the Building panel. - If normal switches shall be used for the building panel, then KX universal interfaces are neccessary - The rotary switches are conventional rotary switches which need KX universal interface for coupling to KX - It is also possible to use only one KX universal interface with multiple channels for multiple devices. Due to installation reasons it is more comfortable to use one KX universal interface per push button or rotary switch Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 2 v. Fax: +3226755028 Ang.-r.:
Possible devices for the frontsides of the panels Flush mounted ED insert, power module 230V AC BJE 2067/12U, BJE 2068/11-84, BJE 1721-184K Rotary switch including KX universal interface BJE 2542 DR/02-84, BJE 2710/1U, BJE 1721-184K, ABB US/U 4.2 ED orientation light with arrow pictogram 230V AC Gira 279820, Gira 0211 21 KX push button, 1 gang (normal push button including KX universal interface) BJE 2020 US, ABB US/S 4.2 ighting tube 230V AC One-gang box for cavity wall installations (depth 61mm, cut out hole diameter 68mm) Kaiser 9064-01 Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 3 v. Fax: +3226755028 Ang.-r.:
ocation of the devices and cut outs OTE: - All cut outs, excepted the drillings for the lighting tube (E2.1 and E2.2), need to have a diameter of 68mm for the one-gang boxes for cavity installation - The drillings for E2.1 and E2.2 need to have a diameter of 25mm - The cut out on the infrastructure panel is only neccessary, if a computer screen for cavity installation is used Building panel Mobility panel Infrastructure panel Energy Generation panel Q1.1 Q1.2 Q4.1 E4.1 E4.2 E2.1 E2.2 Q4.2 E4.3 Q2.1 E4.4 E1.1 E1.2 Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 4 v. Fax: +3226755028 Ang.-r.:
Outlet from booth Distribution Box Overview wiring egend Power KX TP Xa VGA 3 Computer KX TP VGA OTE: The computer is necessary for the presentation about the KX city benefits. The computer screen has to be mounted on the infrastructure panel. The concerning drillings for cables can be done on site. Building panel Mobility panel Infrastructure panel Energy Generation Panel Q4.1 Q1.1 Q2.1 Q4.2 Computer screen Q1.2 E2.1 E4.1 E2.2 E4.2 E1.1 E4.3 E1.2 E4.4 Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 5 v. Fax: +3226755028 Ang.-r.:
,, B16/0,03 1 One pole electrical drawings (without KX) Fa 2 OTE: - A RCD including circuit breaker MUST be used - The circuit breaker shall be not bigger than 13A, B characteristics - Cable diameter shall be E1.1 E1.2 E2.1 E2.2 E4.1 E4.2 E4.3 E4.4 Building panel Mobility panel Energy Generation panel 3 Xa Outlet for computer and concerning screen Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 6 v. Fax: +3226755028 Ang.-r.:
Three pole electrical drawings OTE: - The use of a RCD including cxircuit breaker is a MUST due to safety reasons of booth visitors - The distribution box must have a closable front cover to pretend the touching of energized electrical contacts - A Striebel & John A654T distribution box can be used - For the wiring clamps are neccessary. The neccessary space in the distribution box has to be considered - If a plug is used for feeding the box, the phase of the outlet has to be connected to the phase of the distribution box AD OT to the EUTRA - Please avoid the use of open busbars as cable bridges for or. It is too dangerous due to the fact, that and could be changed by turning the plug and the open busbar would be energized Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 7 v. Fax: +3226755028 Ang.-r.:
z. 9.14 KX+ KXz. 9.14 B13/0,03 1 Indiv. Adr.: 1.1.2 Indiv. Adr.: 1.1.3 KX USB Interface ABB Typ:USB/S1.1 USB - Bus + EIB/KX KX-a KX ogic Module ABB Typ:M/S1.1 - Bus + EIB/KX KX-b 2 Fa S. 9/14 S. 9/14 z. 9.14 USB USB I/O Acess KX programming device KX- KX+ KX I/O KX TP (panels) 3x1,5 X1 Power supply 230V AC Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 8 v. Fax: +3226755028 Ang.-r.:
v. 8.13 KX+ KXv. 8.13 Indiv. Adr.: 1.1.1 Indiv. Adr.: 1.1.4 KX Power Supply ABB Typ:SV/S30.640.5 230V AC 30V DC BUS + - + - EIB/KX KX-c 1 Kanal A 2 3 Kanal B 4 5 Kanal C 6 KX Switching Actuator 8-channel ABB Typ:SA/S8.16.6.1 7 Kanal D 8 9 Kanal E 10 11 Kanal F 12 13 Kanal G 14 15 Kanal H 16 - Bus + EIB/KX KX-d S. 8/11 S. 8/11 v. 8.13 9 3x1,5 X10 Xa 8 3x1,5 X9 E4.4 7 3x1,5 X8 E4.3 6 3x1,5 X7 E4.2 5 3x1,5 X6 E4.1 4 3x1,5 X5 E2.2 3 3x1,5 X4 E.2.1 2 3x1,5 X3 E1.2 1 3x1,5 X2 E1.1 Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 9 v. Fax: +3226755028 Ang.-r.:
KX programming Building panel Q1.1 E1.1 E1.2 0 x x 1 toggle toggle Q1.2 E1.1 E1.2 0 x x 1 x toggle Mobility panel Q2.1 E2.1 E2.2 I 0 0 II 1 0 III 1 1 Rotary switch positions Q2.1: I = (expensive tariff level) II = (normal tariff level) III= (cheap tariff level) Energy Generation panel Q4.1 Q4.2 E4.1 E4.2 E4.3 E4.4 I I 0 0 1 0 I II 0 1 1 0 I III 1 1 1 0 II I 0 1 1 0 II II 1 1 1 0 II III 1 1 1 1 III I 1 1 1 1 III II 1 1 1 1 III III 1 1 1 1 Rotary switch positions Q4.1: I = less renewable generation II = middle renewable generation III= high renewable generation Rotary switch positions Q4.2: I = (expensive tariff level) II = (normal tariff level) III= (cheap tariff level) OTE: - This configuration is only a recommendation - The Energy Generation panel needs to be implemented with KX light scenes and the logic module Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 10 v. Fax: +3226755028 Ang.-r.: