Electrical Drawings for simplified KNX city panels



Similar documents
Current Cost TREC Current Cost ENVI Current Cost EnviR SmartNow Solar Monitoring Kit

How To Use A Power Supply On A Powerline 2.2 (Ai)

Description. Lesson Outcomes. Assumptions. Terminology. Electrician

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) IP66. Improved catch.

Mounting and operating instructions. Surface-mounted hands-free feature home station

know-how Giant in distributing electricity for industry Prisma GK

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Inwall 4 Input / 4 Output Module

Product and functional description

How to Set Up Your NSM4000 Appliance

Operating instructions IV / 2007

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

Setup guide. point to point wall plate extenders

TS2 VRack. User and Installation Manual

Residual Current Devices. Switching on to Safety

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Product and Application Description

THE ADVANTAGES ARE YOURS

3 IN 1 BATHROOM HEATER

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Model SETR-50 and SETR-51 Trim Tab Control

SMART Board 8055i and 8055i-SMP

installation guide ACTIV-1

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

OPERATING INSTRUCTIONS

Basics of Dimming. ISC Learning Centre

Installation Instructions For Slider Casement Air Conditioners

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Interface between Eircom Network and Additional Telephone Equipment

Installation Instructions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

LIEBERT VNSA Installation Sheet

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

HM-W536 Install Guide

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

GLOLAB Two Wire Stepper Motor Positioner

CONSOLE REMOTE I /O AC 9V

SMART Board 8070i-SMP and 8070i

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

Operating Instructions. Keypad

Art Basel Miami Beach Dec Booth Design Regulations

Inwall Room Temperature Unit

SuperWiper Quick Connect (SWP-0001)

Installation Guide for Artic Air 24 Volt R134A Air Conditioner

What ensures easy and fast wiring?

Combi B Alarm box. Mounting instructions

shopinkelowna.com/mr--electric---home- Electrician-West-Kelowna/ htm

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

NETGEAR Trek N300 Travel Router and Range Extender

Replacing an AC Power Cord in a Power Shelf

Quick Connect. quick - simple - efficient.

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

understanding medium frequency induction melting furnace and its components

CutMaster Major External Replacement Parts

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

TruPower-Portable-500W. Solar Starter kit

scalability interoperability modularity 458 Architectural Lighting Control People Innovations Solutions

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

AUDIO l VIDEO END-USER GUIDE. Fernwood 3E02 Conference Room System New Touch Panel

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

User Manual of Grid Tie Inverter with Limiter

IH E Sigma Island 90

Introduction. Page 2 / 9

Circuit Breakers. Next Generation of Protection Capabilities

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Simplicity is the ultimate sophistication. Leonardo da Vinci

Amcrest 960H DVR Quick Start Guide

Low and Medium Voltage Division Erlangen, February 18, New MCCBs for Increased Line Protection and Availability

VEHICLE THEFT/SECURITY SYSTEMS

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Adept SmartModules Quick Setup Guide. V-G(HH) Configuration

ENERGY AWARE. Monitor User Guide

Fused Spur Time Switch

Anthro Tablet Charging Cabinets

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

Modular I/O System Analog and Digital Interface Modules

HERZ-Thermal Actuators

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

The complete range of consumer switchboards and switchgear

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Transcription:

Electrical Drawings for simplified KX city panels Contact: Dipl.-Ing. utz Steiner KX Association cvba Belgium Phone: +4961557029581 Mobil: +491638899639 Email: lutz.steiner@knx.org OTE: - These electrical drawings describe the neccessary electrical installations for the KX city panels - The electrical installations may only be carried out by professional electricians. - The KX Association cvba takes no responsibility for the topicality, correctness, completeness or quality of the information provided in this document. iability claims against KX Associaiton, which refer to material or immaterial nature caused by use or disuse of the presented information or by the use of faulty and incomplete information are excluded. Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 1 v. Fax: +3226755028 Ang.-r.:

egend ED Electrical Installation Flush mounted ED insert, power module 3 Triple outlet ED orientation light with pictogram arrow Single outlet ighting tube KX Rotary switch including KX universal interface KX push button, 1 gang, including KX universal interface OTE: - Any EDs can be used for the Building and Energy Generation panel - The EDs for the Energy Generation panel should contain arrow pictograms - The lighting tubes are conventional lighting tubes e.g. for christmas - Any KX switches from any KX manufactures can be used for the Building panel. - If normal switches shall be used for the building panel, then KX universal interfaces are neccessary - The rotary switches are conventional rotary switches which need KX universal interface for coupling to KX - It is also possible to use only one KX universal interface with multiple channels for multiple devices. Due to installation reasons it is more comfortable to use one KX universal interface per push button or rotary switch Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 2 v. Fax: +3226755028 Ang.-r.:

Possible devices for the frontsides of the panels Flush mounted ED insert, power module 230V AC BJE 2067/12U, BJE 2068/11-84, BJE 1721-184K Rotary switch including KX universal interface BJE 2542 DR/02-84, BJE 2710/1U, BJE 1721-184K, ABB US/U 4.2 ED orientation light with arrow pictogram 230V AC Gira 279820, Gira 0211 21 KX push button, 1 gang (normal push button including KX universal interface) BJE 2020 US, ABB US/S 4.2 ighting tube 230V AC One-gang box for cavity wall installations (depth 61mm, cut out hole diameter 68mm) Kaiser 9064-01 Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 3 v. Fax: +3226755028 Ang.-r.:

ocation of the devices and cut outs OTE: - All cut outs, excepted the drillings for the lighting tube (E2.1 and E2.2), need to have a diameter of 68mm for the one-gang boxes for cavity installation - The drillings for E2.1 and E2.2 need to have a diameter of 25mm - The cut out on the infrastructure panel is only neccessary, if a computer screen for cavity installation is used Building panel Mobility panel Infrastructure panel Energy Generation panel Q1.1 Q1.2 Q4.1 E4.1 E4.2 E2.1 E2.2 Q4.2 E4.3 Q2.1 E4.4 E1.1 E1.2 Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 4 v. Fax: +3226755028 Ang.-r.:

Outlet from booth Distribution Box Overview wiring egend Power KX TP Xa VGA 3 Computer KX TP VGA OTE: The computer is necessary for the presentation about the KX city benefits. The computer screen has to be mounted on the infrastructure panel. The concerning drillings for cables can be done on site. Building panel Mobility panel Infrastructure panel Energy Generation Panel Q4.1 Q1.1 Q2.1 Q4.2 Computer screen Q1.2 E2.1 E4.1 E2.2 E4.2 E1.1 E4.3 E1.2 E4.4 Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 5 v. Fax: +3226755028 Ang.-r.:

,, B16/0,03 1 One pole electrical drawings (without KX) Fa 2 OTE: - A RCD including circuit breaker MUST be used - The circuit breaker shall be not bigger than 13A, B characteristics - Cable diameter shall be E1.1 E1.2 E2.1 E2.2 E4.1 E4.2 E4.3 E4.4 Building panel Mobility panel Energy Generation panel 3 Xa Outlet for computer and concerning screen Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 6 v. Fax: +3226755028 Ang.-r.:

Three pole electrical drawings OTE: - The use of a RCD including cxircuit breaker is a MUST due to safety reasons of booth visitors - The distribution box must have a closable front cover to pretend the touching of energized electrical contacts - A Striebel & John A654T distribution box can be used - For the wiring clamps are neccessary. The neccessary space in the distribution box has to be considered - If a plug is used for feeding the box, the phase of the outlet has to be connected to the phase of the distribution box AD OT to the EUTRA - Please avoid the use of open busbars as cable bridges for or. It is too dangerous due to the fact, that and could be changed by turning the plug and the open busbar would be energized Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 7 v. Fax: +3226755028 Ang.-r.:

z. 9.14 KX+ KXz. 9.14 B13/0,03 1 Indiv. Adr.: 1.1.2 Indiv. Adr.: 1.1.3 KX USB Interface ABB Typ:USB/S1.1 USB - Bus + EIB/KX KX-a KX ogic Module ABB Typ:M/S1.1 - Bus + EIB/KX KX-b 2 Fa S. 9/14 S. 9/14 z. 9.14 USB USB I/O Acess KX programming device KX- KX+ KX I/O KX TP (panels) 3x1,5 X1 Power supply 230V AC Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 8 v. Fax: +3226755028 Ang.-r.:

v. 8.13 KX+ KXv. 8.13 Indiv. Adr.: 1.1.1 Indiv. Adr.: 1.1.4 KX Power Supply ABB Typ:SV/S30.640.5 230V AC 30V DC BUS + - + - EIB/KX KX-c 1 Kanal A 2 3 Kanal B 4 5 Kanal C 6 KX Switching Actuator 8-channel ABB Typ:SA/S8.16.6.1 7 Kanal D 8 9 Kanal E 10 11 Kanal F 12 13 Kanal G 14 15 Kanal H 16 - Bus + EIB/KX KX-d S. 8/11 S. 8/11 v. 8.13 9 3x1,5 X10 Xa 8 3x1,5 X9 E4.4 7 3x1,5 X8 E4.3 6 3x1,5 X7 E4.2 5 3x1,5 X6 E4.1 4 3x1,5 X5 E2.2 3 3x1,5 X4 E.2.1 2 3x1,5 X3 E1.2 1 3x1,5 X2 E1.1 Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 9 v. Fax: +3226755028 Ang.-r.:

KX programming Building panel Q1.1 E1.1 E1.2 0 x x 1 toggle toggle Q1.2 E1.1 E1.2 0 x x 1 x toggle Mobility panel Q2.1 E2.1 E2.2 I 0 0 II 1 0 III 1 1 Rotary switch positions Q2.1: I = (expensive tariff level) II = (normal tariff level) III= (cheap tariff level) Energy Generation panel Q4.1 Q4.2 E4.1 E4.2 E4.3 E4.4 I I 0 0 1 0 I II 0 1 1 0 I III 1 1 1 0 II I 0 1 1 0 II II 1 1 1 0 II III 1 1 1 1 III I 1 1 1 1 III II 1 1 1 1 III III 1 1 1 1 Rotary switch positions Q4.1: I = less renewable generation II = middle renewable generation III= high renewable generation Rotary switch positions Q4.2: I = (expensive tariff level) II = (normal tariff level) III= (cheap tariff level) OTE: - This configuration is only a recommendation - The Energy Generation panel needs to be implemented with KX light scenes and the logic module Projekt: KXcity Panels KX Association cvba Projekt.-r.: Bl. 10 v. Fax: +3226755028 Ang.-r.: