VIBRATION SWITCHES SOLID STATE



Similar documents
Low Frequency Velocity Sensor

SKF Machine Condition Transmitters (MCT) Series

Electronic, Digital and Mechanical Vibration Switches

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Proximity Transmitters and Seismic Vibration Transmitters

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

9000 Series Accelerometers Specifications

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

and Accelerometers

Centro-Matic Automatic Lubrication Systems System Controls

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Velomitor Piezo-velocity Sensor

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

DUCT SMOKE DETECTOR D4120

Electronic Flow Switches

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

MTII4200 level Transmitter Installation, Operation & Maintenance Instructions

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Troubleshooting accelerometer installations

Sanitary Type Electronic Flow Switches

Duct Humidity Transmitter

38 Series - Relay interface modules A

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

1701/22 FieldMonitor Management Interface Module

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

DPI 260 SERIES: Digital Pressure Indicators

Speed Control Relays SX2

38 Series - Relay interface modules A

In-Line Electronic Flow Switches

3500/62 Process Variable Monitor

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Electronic Control Devices The European Product Catalogue 2007

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Advantium 2 Plus Alarm

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Power Supplies 3. SDN-P DIN Rail Series

DS 600. A contact free flux gate based current measurement sensor 600A rms

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Solid-State Timer H3G

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Contents. Document information

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Solid State Timers Type F

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

IMVIB. Online vibration monitoring for Ariel compressors

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

TC-9102 Series Surface Mount Temperature Controllers

O C M III. Open Channel Flow Monitor

49 Series - Relay interface modules A. Features

Short information Parameters are programmed via front-side membrane keypad

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

In-Line Electronic Flow Switches

Electronic Control Devices The European Product Catalogue 2007

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Pressure Switch for gas and air

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Cost effective Predictive Maintenance solutions

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

B-Series Temperature Switches

NetScanner System. Toronto: , Montreal: , Toll Free: ,

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

MasterINTERFACE 39 Series - Relay interface modules

How To Power A Schen

Rack mounted telephone- and leased line modem for industrial applications

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

LOXONE 12 Channel Amplifier

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

MasterINTERFACE 39 Series - Relay interface modules

SMART SENSOR COLLECTION

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

THERMAL MANAGEMENT SOLUTIONS

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

TC 1818a. Operating Guide. Control Module SWM-015.5

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Antec TruePower User's Manual

Bulletin 150 SMC Flex Smart Motor Controller Specifications

PART 1 - INTRODUCTION...

Research RF Sputtering Packages

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Rosemount 333 HART Tri-Loop

For Multi-Parameter Meters see mvx

SECTION LOW VOLTAGE LIGHTING CONTROLS

Transcription:

SOLID STATE VIBRATION SWITCHES The PMC/BETA electronic vibration switch makes available in a relatively low-cost device many of the benefits formerly found only in high-end protection systems. Model Adjustable time delay High accuracy No false triggering Analog output available Self-test function Built-in or remote transducer SHUTDOWN 8 Test IN/SEC.. Internal View ALARM Test PERCENT 8 9 RESET COMMON SHUT- DOWN INPUT POWER XDUCER XDUCER XDUCER COMMON ANALOG ALARM GROUNDING TERMINAL 8 9 Model

Protect Your Rotating Machinery with Solid State Vibration Switches for Alarm and Shutdown Provide Early Warning Avoid Catastrophic Failure Unique Features Vibration is an excellent early warning of machine deterioration. The PMC/BETA Series vibration switches sense the causes of excessive machine vibration and machine failure. The major causes are: imbalance of a rotating member (about % of the time), misalignment (%), defective bearings (%) and defective belts (%). The PMC/BETA vibration switch responds to destructive vibration by shutting down your machine when the vibration trip level is exceeded, preventing catastrophic damage and extensive repairs and downtime. Small and gradual machine deterioration shows up as significantly increased vibration. Early detection usually permits continued operation until a scheduled shutdown. Built-in time delay, field adjustable. No false triggering. Velocity triggering provides protection at all frequencies. Displacement triggering available for low speed machinery. Sensitivity is not affected by rotating speed of machinery. Calibrated dial for setting limits. Solid state relay contacts used for alarm and/or shutdown. Field settable for N.O. or N.C. Remote reset capability. Provision for self-test and calibration. - ma output proportional to vibration level (on Models SR and DR) can be used for remote readout and trending of vibration levels. Built-in transducer or optional remote transducer. Cast aluminum enclosures meet NEMA,, and standards. Explosion-proof models ( Series) available. Model D, NEMA, Class I, Div., Grps. B,C & D Model D, NEMA, Class I, Div., Grps. B, C & D Model S/S (Single Trip) One limit for alarm or shutdown. Model SR/SR (Single Trip w/- ma output) One limit for alarm or shutdown, and - ma output for remote vibration readout or computer interface. Model D/D (Dual Trip) One limit for alarm, a second limit for shutdown. Model DR/DR (Dual Trip w/- ma output) One limit for alarm, a second limit for shutdown, and - ma output for remote vibration readout or computer interface.

Unique Design Features Built-in piezoelectric transducer module with integral amplifier provides to, CPM capability. Calibrated set point controls enable operator to set specific velocity trip points. VDE approved terminal strip accepts # wire. Screw adjustable clamping yoke rather than screw terminal permits easy, vibration proof connection. All hardware is captive. Light comes on immediately when vibration exceeds set point (alarm or shutdown will trip after second time delay). Adjustable time delay of - seconds. Factory set at seconds. Test position sets in minimum set point so that any vibration will cause trip condition. Light will come on immediately, and trip will occur after duration of the time delay, proving that the complete system is operational. If test position is maintained for less than the duration of the time delay, trip will not occur, thus permitting system test without shutdown. Each solid-state contact is independently field settable to open on alarm (N.C.) or close on alarm (N.O.). Specifications Model No. No. of Trips S SR ONE: for alarm or shutdown. Set in in/sec (velocity model) or mils (displacement model). D DR TWO: One for alarm and one for shutdown. Shutdown set in in/sec (velocity model) or mils (displacement model). Alarm set as percent of shutdown. Analog Output for Remote Indication Velocity Set Point Displacement Model Frequency Range Time Delay N/A ± % accuracy over - ma DC range. ma is vibration; ma is set point; ma is % of setpoint. Termination load resistance, less than ohms N/A ± % accuracy over - ma DC range. ma is vibration; ma is set point; ma is % of setpoint. Termination load resistance, less than ohms. to. in in/sec or. to in/sec peak. Metric ranges: to mm/sec or to 8 mm/sec peak (Select one) to mils or to mils peak to peak. Metric ranges: µm to µm or µm to mm peak to peak (Select one) to Hz ( to, RPM) Field adjustable - sec. Factory set for sec unless specified otherwise Alarm or Shutdown Output(s) Solid state relay (triac). One in S, SR; Two in D, DR Isolated (dry) contact Each triac field settable for close on alarm (N.O.) or open on alarm (N.C.) A continuous, A for msec. Max. off-state leakage current: ma Min holding current: ma typical Max. voltage across SS relay: VAC (8VAC on V input units) NOTE: If the relay output is connecting to a PLC or DCS, DO NOT use A Triac. See options for D & E on Designation page. Remote Reset Set Point Accuracy Vibration Sensitive Axis Temperature Limits Humidity Input Power Enclosure Weight Mounting Terminals Self Test Circuitry Remote Transducer Option Connection between terminals and latches triac output in alarm state after setpoint is exceeded. Opening the connection will reset the output to non-alarm state. ± % of setting with repeatability of ± %. Circuitry utilizes RMS detector Perpendicular to base. Unit can be mounted in any orientation without affecting setting - F to + F (- C to + C) including internal transducer. - F to +9 F (- C to +88 C) for optional external transducer % to % (non-condensing) - VAC / Hz standard. - VAC / Hz optional. DC input power optional. S, Watt, D, Watt Rugged, water-tight, dust-tight, cast aluminum. Meets NEMA,, and standards. Optional explosion-proof Model available.. lbs (. Kg) / hardware, mounting bosses All terminals will accept # AWG wire in clamping type yoke without need for termination hardware. ALL hardware is captive. Test position on set point control and light emitting diode provide functional test of trip circuitry, time delay and triac closure. Also permits on-line calibration of switch. Proprietary hybrid circuitry throughout for minimum size and maximum reliability in vibration environment. The standard includes a built-in transducer. A separate transducer can be specified. Please request separate transducer when placing order. See Designation page. We recommend Model ICP Accelerometer with Cable L-XX, where XX is the length of the cable in feet.

More Features and Benefits Single or Dual Trip Switches Provide Early Warning The S provides a single switch closure which can be used for alarm or shutdown. However, it is often desired to provide a warning before shutdown. The D is ideal for this requirement. It provides two trips: one for alarm and one for shutdown. The first trip is set at a vibration alarm level to provide early warning that the condition of the machine is deteriorating. When the alarm trip occurs, the operator can evaluate the condition and schedule corrective maintenance - at a time that does not interrupt the production schedule. If the machine condition continues to deteriorate, the shutdown trip provides protection against catastrophic failure. The / as a Vibration Transmitter The - ma output available on Models SR and DR can be utilized for remote readout of vibration level or as a transmitter to interface with customer computers and data handling systems presently used with pressure, flow and temperature transmitters, etc. The user can detect vibration levels which may be increasing, but which are not yet serious enough to trip the alarm. How the / Works These electronic switches utilize a solid state crystal accelerometer which provides an electrical output when it is deformed by the vibration forces. The output is electronically converted to a signal proportional to velocity. This signal is compared with a present limit and triggers a solid state relay if the limit is exceeded. There are no moving parts in the vibration switches except when configured with mechanical relays. While the costs more than a mechanical switch, it uses the same technology as sophisticated remote monitoring systems and provides most of the capabilities of these systems at / to / the cost per monitor point. Velocity Trip The different causes of machinery failure (imbalance, misalignment, bearings, etc.) result in increased vibration at different frequencies (CPM) on a given machine. Therefore, it is important that the vibration protection device be equally sensitive to damaging vibration at all frequencies. International standards for rotating machinery (ISO, 9) specify that vibration severity is directly related to vibratory velocity. The PMC/BETA / series electronic vibration switches measure and trip on velocity. In mechanical switches, sensing and tripping are inherently limited to impact/acceleration. Since severity (damage potential) is proportional to velocity, acceleration tripping is oversensitive to some frequencies and not sensitive enough to others - with the result of either false trips in some cases, or not enough protection in others. Built-in Time Delay Avoids False Trips An important feature of PMC/BETA switches is the built-in time delay. This prevents triggering of the alarm or shutdown functions from transient increases in vibration levels. It also avoids shutdown due to transitory vibrations occurring during start-up. Almost all machines experience a few seconds of high vibration during start-up before reaching operating speed. When no time delay function is included, as with mechanical switches, this start-up vibration causes a trip. Frequently, the operator turns the trip setting up until he can get through start-up. The resultant trip level is too high to afford protection at the machine s operating speed. Three-second time delay is provided as standard on all PMC/BETA switches. The time delays are independently adjustable in the field over a range of to seconds. Why Use Remote Sensors Vibration switches can be configured to work with external sensors (accelerometers, velocity pickups or transmitters). When an external sensor is used, the internal accelerometer is not present. Mounting location size, temperature considerations, vibrating environment and application would determine when to use an external sensor. For example, if the vibration switch is too large to fit a machine location, consider using a remote accelerometer and an interconnecting cable.

Notes: Model / Designation Model A - BCDE - FGHI - JKLMN Model A - BCDE - FGHI - JKLMN units, except those w/ mechanical relays and external transducers carry a CSA label. enclosure is coated with epoxy paint. Rated CSA, NEMA, Class I, Grps B, C & D; Class II, Grps, E, F & G Special modifications and options will receive an M number, assigned by the factory. A = Single or Dual Trip/Analog Signal Output S SR D DR = Single Trip = Single Trip, Analog Signal Output = Dual Trip = Dual Trip, Analog Signal Output C = Scale =. -. in/sec =. -. in/sec = - mm/sec = - 8 mm/sec = - mils displacement, pk-pk = - mils displacement, pk-pk = - microns displacement, pk-pk =. - mm displacement, pk-pk 8* = - Impacts 9* = - % of transmitter scale *NOTE: For use with a Vdc loop-powered transmitter. B = Analog Signal Output = None = - ma, dependent = - ma, absolute = - Vdc, absolute = - Vdc, dependent = - Vdc, absolute = - Vdc, dependent D = Shutdown Circuit * = Triac, A, SPST (for switching heavy AC loads) = ma, Volts, Pk, analog, SPST switch, good selection for use with PLC or DCS = OBSOLETE,. Amp SPDT relay (replace w/ x, A SPST relay) = A SPDT relay = A DPDT relay where A = S or SR only = A, V pk, Analog Switch = ma, V, pk, Analog Switch E = Alarm Circuit (Always if A = S or SR) = None = Triac, A Standard = ma, Volts Pk, Analog SPST Switch (Use for PLC or DCS) = OBSOLETE,. Amp SPDT relay (replace w/ x, A SPST relay) = A SPDT relay Alarm Only = OBSOLETE, A DPDT Relay, Internal Xducer only = V, pk, A Analog Switch = ma, V, pk, Analog Switch F = Enclosure 8 = Standard = OBSOLETE, All s have epoxy paint = Pushbutton reset = OBSOLETE, See F = or = OBSOLETE, All s are Grps B,C & D = Velocity signal out via BNC connector, 8 mv, rms/ips, pk = Pushbutton reset and Velocity out = Acceleration signal out via BNC connector, mv/g = Pushbutton reset and BNC Accel. out G = Input Power = Vac, / Hz = Vac, / Hz = Vdc ± % = OBSOLETE, Vdc ± % = OBSOLETE, 8 Vac, / Hz H = Lockout Function = None = Lockout = sec startup, lockout delay = OBOLETE, -9 sec variable startup, lockout delay = OBSOLETE, Vdc enabled lockout, input power must be Vdc I = Configured for which Transducer = Internal = A, FM or E Accelerometer = 8 Velocity Xducer = C Piezo-Velocity Xducer = A-E X-proof Accelerometer = Constant Current Accelerometer = 8E X-proof velocity Xducer = Other Constant Current mv/g Accelerometer 8* = Vdc loop-power transmitter *NOTE: Available with to % of transmitter input range or to impacts. J = Other Special = CE mark for only Leave BLANK if not applicable. K = Type Scale = to pk = RMS = pk to pk L, M, N = External Transducer Sensitivity mv/unit use when applicable Please contact factory for options and pricing.

Remote Readout and Remote Transducer Options Model / Switch Machine Model 8- Meter Machine Transducer Model / Switch Remote indicator with Model / vibration switch. Remote sensors with Model /. The Model 8- meter will provide continuous readings of vibration level from the - ma analog output of the SR or the DR. The meter reads from to % of shutdown setpoint. The - ma output can also be used to drive a strip chart recorder or PLC input. Outline Drawing of Model Dimensions in mm [inches] 89 [.] SENSITIVE AXIS. [.8] 89 [.]. [.] 8 [.] [.] 89 [.]. [.] X.9 [.]. [.] The standard / includes a built-in transducer. For some applications, a remotetransducer is desirable as an option in place of the internal transducer. The can then be mounted in any convenient location up to, feet away. The / can be configured for up to remote sensors with a variety of input sensors and transmitters. Available Transducers SA Accelerometer, available with two pin MS style connector or integrated cable. 8 Velocity Transducer, available with a three pin MS style connector SA High Temp. Accelerometer, available with two pin MS style connector ST8E or VTS Slim design Velocity Transmitter, available with flying leads, terminal blocks or MS connector Available Cables Two () pin socket connector with integral, molded splash proof boot with. mm (. ) diameter polyurethane jacketed cable with twisted shielded pair wires. XXX.X = cable length in meters. P/N 898-- XXXX Splashproof Cable Assembly Two () pin socket connector with integral, molded splash proof boot with. mm (.8 ) diameter, SS armored jacket with cable, twisted shielded pair wires. XXX.X = cable length in meters. P/N 9--XXXX Splashproof Cable Assembly w/ss Armor Two () pin socket connector w/o cable. P/N 898- - Connector Assembly Three () pin socket MS style connector with cable. P/N L-XX. 9. [.] / - NPT Weight:. kg [. lbs] March www.metrix.com Reliability and Innovation since 9 Sales & Service Tel: -- Fax: --8 sales@metrix.com Townhurst Dr. Houston, TX -899