JDSU PathTrak. HCU200 Install User s Guide



Similar documents
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Pathtrak Return Path Monitoring System

How to Set Up Your NSM4000 Appliance

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

User Manual. EtherUSB

Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Disclaimers. Important Notice

Wi-Fi Setup Guide USING YOUR DMX PROFUSION is FOR

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

MultiVOIP FX SIP Gateways

HP UPS R1500 Generation 3

Welch Allyn Vital Signs Monitor 300 Series

5330 IP Phone Quick Reference User Guide

BACnet Automation Interface Module (Network Version)

WD Sentinel DX4000. Small Office Storage Server Administrator s Quick Install Guide

WD Sentinel DX4000. Small Office Storage Server. Administrator s Quick Install Guide

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

NetClock 9400 SeriesTM

User Manual. EtherUSB

BX7000 Multi-Access Gateway Getting Started Guide

The SYSTIMAX ipatch System

MultiVOIP FX FXS-Only SIP Gateways

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

Chapter 1 Installing the Gateway

GV-Data Capture V3 Series User's Manual

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Amcrest 960H DVR Quick Start Guide

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

SNMP Web Management. User s Manual For SNMP Web Card/Box

Chapter 1 Connecting the Router to the Internet

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

IP DSLAM IDL Quick Installation Guide

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Notice. Reverse engineering and disassembly are prohibited.

USB Ethernet Connectivity Kit

How To Set Up A Gxp280 Ip Phone On A Cell Phone On Your Computer Or Ip Phone (Siphone) On A Sim Sim Sim Or Ipro (Cell Phone) On Your Ipro Or Ipo (Cellphone) On

SMAC SM Status Monitoring and Control Quality of Service (QoS) Diplex Switch Test Gear. Installation & Operation Manual

P Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address Password Version /2007 Edition 1

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

INSTALLATION INSTRUCTIONS

NeoGate TA Series Installation Guide

Energy Communication Unit (ECU)

The power module is Feature Number 8800-F2-901.

Configuring an A Series LED Sign Controller for your Network

Quick Installation Guide. Overview. GULFSIP ATA-G1S Quick Installation Guide

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Crow Limited Warranty. Print Version 017

Setting Up the Cisco IP Phone

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

HP Port Switches Quick Setup Guide

SOYO G668 VOIP IP PHONE USER MANUAL

Acano solution. Acano Solution Installation Guide. Acano. January B

Internet Telephony PBX System. (30/100 SIP Users registrations) IPX-330 / IPX Quick Installation Guide

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

C24-CAMANL Video Server/Encoder

Infinity C Reference Guide

Introducing Your Cisco IP Phone

ilan Ethernet Box for 9100 Installation Manual

STAGE SETTER-8. User Instructions. Elation Professional

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Connecting to the Internet

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

3.5 EXTERNAL NETWORK HDD. User s Manual

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400

Inter-Tel IP Phone Quick Reference Guide

StereoBrain. Network Interface Set-up

UDS2100 Quick Start Guide

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Wash Select II to WashPay Integration Field Retrofit Installation Guide

P-660HNU-Tx. Wireless N ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v1.02 Edition 1, 11/2011. IP Address:

8-Port PoE Network Switch

HWg-STE HWg-STE PoE MANUAL

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

JDSU HST-3000 RFC-2544 Ethernet Testing Guide

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

GBIC-Optical SX 850nm (Multi Mode) GBIC-Optical LX 1310nm (Single Mode) GBIC-Electrical TX 1000 BaseT (RG-45)

MVP-200 Digital Video Probe JDSU PathTrak Video Monitoring

Setting Up the ZigBee Ethernet Gateway

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

Foglight Experience Monitor and Foglight Experience Viewer

KNX IP INTERFACE IN00A02IPI. Operating and installation manual

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

OPT SERIAL TO FIBER OPTIC CONVERTER

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

User Manual Revision English

Installation Manual Premier Elite ComIP

CallFinder. Model CF220 DID Adapter Quick Start Guide

Welcome. Unleash Your Phone

Transcription:

JDSU PathTrak HCU200 Install User s Guide

Notice Copyright System Requirements The information contained in this document is the sole property of JDSU and may not be reproduced, copied, or communicated to third parties without written notice and permission by JDSU. This material will be given to direct partners and developers working with JDSU who have signed non-disclosure agreements. Such second parties may freely copy and distribute this information within their organizations but agree to keep such communications restricted to their internal employees on a need-to-know basis. Copyright 2010 JDSU. All rights reserved. HCU200 Module -48V DC Power Supply (+/- 5%, 1A max current) 10/100 BaseT Ethernet connection with static IP RF Feed(s) (0-50 dbmv input level) PathTrak Server/Client Software Version 2.6 or higher Server PC (See "PathTrak and WebView System Requirements" for details) CAUTION Be sure that power is off on the -48V DC power source before connecting or disconnecting power leads to the HCU200. Do NOT install HCU200 modules unless properly trained in handling ESD-sensitive materials like the HCU200. Any damage caused by improper or incorrect handling voids the entire PathTrak system warranty. PathTrak HCU200 Install User s Guide Rev. 000 i

ii PathTrak HCU200 Install User s Guide Rev. 000

Table of Contents Section 1 Getting to know the HCU200 1 Section 2 HCU200 Unpacking and Setup 2 Section 3 Related Information 8 Section 4 Technical Assistance 9 Section 5 Warnings 11 Section 6 Equipment Ratings 12 PathTrak HCU200 Install User s Guide Rev. 000 iii

iv PathTrak HCU200 Install User s Guide Rev. 000

Section 1: Getting to know the HCU200 Section 1: Getting to know the HCU200 The front panel consists of: The power button The 4 cursor or arrow keys The "Enter" or "Accept" button The "Exit or "Cancel" button The information LCD PathTrak HCU200 Install User s Guide Rev. 000 1

Section 2: HCU200 Unpacking and Setup Section 2: HCU200 Unpacking and Setup 1 Remove HCU200 from box and carefully remove all packaging material. 2 Mount HCU200 module in rack using the four holes provided on the front panel. 3 Connect grounding strap of chassis to Earth Grounding termination screws on the rear panel of the HCU200. 4 Remove the protective cover over the DC power lugs on the rear panel of the HCU200. a If using an existing -48VDC power supply double-check that power is turned off. Connect the -48V and RTN leads from the power supply to the appropriate power lugs on the rear panel of the HCU200. b If using the JDSU-supplied optional AC power adaptor, connect the adaptor terminals to the appropriate HCU200 power lugs. Black wire goes to -48VDC lug, white wire goes to RTN lug. 5 Replace the clear plastic cover over the power lugs. 6 Connect jumpers from the RF source (commonly 8- way splitter off of return optical receiver) to the appropriate ports on the rear of the HCU200. 7 If using an HSM-1000 for Field View capability please see Document 6710-30-0005 (HSM-1000 Install Guide) for details of HSM installation and configuration. 8 Connect Ethernet feed to RJ45 connector socket on the rear of the HCU200. 9 Apply power to the HCU200. Once power is applied to the HCU200 the LCD will display: 2 PathTrak HCU200 Install User s Guide Rev. 000

Section 2: HCU200 Unpacking and Setup Figure 1 LCD Display Screen and Keypad Figure 2 LCD Display at Start-Up NOTE The actual IP address that appears may be different than shown below. 10 After approximately 20 seconds the LCD will display: Figure 3 IP Address of HCU200 Figure 4 explains what each line and/or symbol on the LCD is showing. Figure 4 Explanation of LCD Fields PathTrak HCU200 Install User s Guide Rev. 000 3

Section 2: HCU200 Unpacking and Setup There are five different fields that may be viewed on the LCD by using either the up or down arrow keys to scroll. Three may be edited, the other two which are for informational purposes only. Shown below are the three fields which may be edited: (All field values may be different from what is shown) Figure 5 IP address of the HCU200 Figure 6 Subnet mask of the HCU200 Figure 7 Default gateway of the HCU200 Figure 8 and Figure 9 show the remaining two fields that are informational only and cannot be edited from the HCU200 front panel. The horizontal line immediately below the down arrow is not present in these two fields indicating that they cannot be edited via the front panel. 4 PathTrak HCU200 Install User s Guide Rev. 000

Section 2: HCU200 Unpacking and Setup Figure 8 Physical (MAC) address of the HCU200 Ethernet adapter Figure 9 IP address of the PathTrak server that this HCU200 is connected to (This will change/ update when the HCU200 is added to a new server) CAUTION Before setting any IP address information in the HCU200, please confirm with your network administrator that the IP addresses you have are valid for your network configuration and will not cause any conflicts on your local area network. 11 Using the keypad and display on front panel or PathTrak Client software, IP address of HCU200 to appropriate value. Setting the IP address information on the HCU200 is a simple process done completely from the front panel of the unit. 12 To set the IP address of the HCU200, use the up or down arrow keys to scroll to the IP address field on the LCD and press the "Enter" button. The horizontal line that indicates that this is a field that may be edited drops to the bottom of the first digit in the IP address field becoming a cursor and indicating that the HCU is now in "edit mode" (Figure 10). PathTrak HCU200 Install User s Guide Rev. 000 5

Section 2: HCU200 Unpacking and Setup Figure 10 IP Address in Edit Mode 13 Use the up or down arrow keys to set the first number of the first IP address octet (range blank thru 2). If the first octet is less than 100, scroll until the digit is blank. Once the first number is set, use the right arrow key to move the cursor to the second number of the first IP address octet (Figure 11). Figure 11 IP Address in Edit Mode (1st Octet) 14 Use the up or down arrow keys to set this number to the proper value (range 0 thru 9). Once this number is set, use the right arrow to move the cursor to the next digit. 15 Follow the same process until the correct IP address shows on the display and then press "Enter". This will save the address information and place the unit back in normal operation mode. 16 Now, press the down arrow to go to the subnet mask field and repeat the process used to set the IP address. When the subnet mask is correct, press the down arrow and repeat once more for the default gateway. 6 PathTrak HCU200 Install User s Guide Rev. 000

Section 2: HCU200 Unpacking and Setup 17 There is no need to reboot the HCU200. Once you press the "Enter" button at the end of each field, the address is set and applied. When all the addresses are set, verify network connectivity from the Path- Trak server to the HCU200. 18 The PathTrak Server AND Client must be at least version 2.6 to recognize the HCU200. 19 Proceed with adding the HCU200 to a PathTrak Server per instructions documented in Chapter Three of document 6510-00-0430. Figure 12 HCU200 Rear Panel PathTrak HCU200 Install User s Guide Rev. 000 7

Section 3: Related Information Section 3: Related Information Use this guide in conjunction with the following information: JDS Uniphase Corporation DSAM Product Family Series Server/Client Complete DSAM Meter Functionality Installation Guide (P/N 6510-30-0416) JDS Uniphase Corporation DSAM Product Family Series RPM1000 Installation Guide (P/N 6510-30-0415) JDS Uniphase Corporation DSAM Product Family Series RPM2000 Installation Guide (P/N 6510-30-0423) JDS Uniphase Corporation DSAM Product Family Series RPM3000 Quick Start Guide (P/N 21121380-001) 8 PathTrak HCU200 Install User s Guide Rev. 000

Section 4: Technical Assistance Section 4: Technical Assistance If you need assistance or have questions related to the use of this product, call or e-mail JDS Uniphase Corporation s Technical Assistance Center for customer support. Table 1 Region Technical assistance centers Phone Number Cable TV/Multimedia Products Europe, Africa, and Mid-East 1 800 428 4424 Ext. 8350 (America) 1 317 788 9351 Ext. 8350 (World Wide) +49 (0) 7121 86 1345 (Europe) +800 882 85822 (European Freephone) +49 (0) 6172 59 11 00 (JDS Uniphase Corporation Germany) +33 (0) 1 39 30 24 24 (JDS Uniphase Corporation France) catv.support@jdsu.com hotline.europe@jdsu.com support.uk@jdsu.com hotline.germany@jdsu.com hotline.germany@jdsu.com Asia Pacific +852 2892 0990 (Hong Kong) +86 10 6655 5988 (Beijing-China) All others 1 866 228 3762 tac@jdsu.com PathTrak HCU200 Install User s Guide Rev. 000 9

Section 4: Technical Assistance During off-hours, you can request assistance by doing one of the following: leave a voice mail message at the Technical Assistance number in your region; e-mail North American Technical Assistance Center, tac@jdsu.com, or European Technical Assistance Center, support.uk@jdsu.com; or submit your question using our online Technical Assistance Request form at www.jdsu.com. 10 PathTrak HCU200 Install User s Guide Rev. 000

Section 5: Warnings Section 5: Warnings The HCU200 is a Measurement Category I device for measurements on circuits and SHOULD NOT be used for measurements within measurement categories II, III and IV circuits*. WARNING If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. WARNING Do not disassemble the HCU. Do not attempt to service this product yourself. There are no user-serviceable parts inside. Contact the appropriate JDSU representative for HCU repair or calibration. * Measurement Category I: Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. PathTrak HCU200 Install User s Guide Rev. 000 11

Section 6: Equipment Ratings Section 6: Equipment Ratings Input Connection Description 16 RF Input Ports, 75 ohm, dynamic voltage range 0-50 dbmv 1 Serial RS232 port 1 10/100 baset Ethernet port 1 USB port 1 Trigger I/O port 2 Earth Grounding Termination screws Environmental Conditions Operating Temperature: 5 C (41 F) to 45 C (113 F) 12 PathTrak HCU200 Install User s Guide Rev. 000

Test and Measurement Regional Sales North America Toll Free: 1 800 638 2049 Tel: +1 240 404 2999 Fax:+1 240 404 2195 Latin America Tel: 954-688-5660 Fax:954-846-8856 Asia Pacific Tel: +852 2892 0990 Fax:+852 2892 0770 EMEA Tel: +49 7121 86 2222 Fax:+49 7121 86 1222 www.jdsu.com Doc. 21155873-001 Rev. 000 September- 2010 English