Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories



Similar documents
Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE

Seismic Isolation Retrofitting of Japanese Wooden Buildings

Seismic performance evaluation of an existing school building in Turkey

REVISION OF GUIDELINE FOR POST- EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN

Seismic Risk Evaluation of a Building Stock and Retrofit Prioritization

Seismic Risk Prioritization of RC Public Buildings

SEISMIC CAPACITY OF EXISTING RC SCHOOL BUILDINGS IN OTA CITY, TOKYO, JAPAN

EARTHQUAKE DISASTER MITIGATION USING INNOVATIVE RETROFITTING METHOD

EFFECT OF POSITIONING OF RC SHEAR WALLS OF DIFFERENT SHAPES ON SEISMIC PERFORMANCE OF BUILDING RESTING ON SLOPING GROUND

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

Specification for Structures to be Built in Disaster Areas

SEISMIC DESIGN OF MULTI-STORY BUILDINGS WITH METALLIC STRUCTURAL FUSES. R. Vargas 1 and M. Bruneau 2 ABSTRACT

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY

Seismic Analysis and Design of Steel Liquid Storage Tanks

Development of Seismic-induced Fire Risk Assessment Method for a Building

Earthquakes and Data Centers

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

NONLINEAR BEHAVIOR AND FRAGILITY ASSESSMENT OF MULTI-STORY CONFINED MASONRY WALLS UNDER CYCLIC LOADS

Optimum proportions for the design of suspension bridge

Methods for Seismic Retrofitting of Structures

Guidelines for Promotion of Earthquake-resistance School Building July 2003

EXAMPLES OF SEISMIC RETROFITTING IN JAPAN

STRUCTURAL DAMAGE OF A 5-STOREY BUILDING: DIFFERENTIAL SETTLEMENT DUE TO CONSTRUCTION OF AN ADJACENT BUILDING OR BECAUSE OF CONSTRUCTION DEFECTS?

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

BLIND TEST ON DAMAGE DETECTION OF A STEEL FRAME STRUCTURE

SEISMIC DESIGN OF HIGHWAY BRIDGES

Hybrid simulation evaluation of the suspended zipper braced frame

ABSG Consulting, Tokyo, Japan 2. Professor, Kogakuin University, Tokyo, Japan 3

VERIFICATION OF THE METHOD FOR IMPROVING ACCURACY OF SIMPLIFIED SEISMIC RESPONSE ANALYSIS OF STEEL RIGID FRAME VIADUCTS

REPAIR AND RETROFIT OF BRIDGES DAMAGED BY THE 2010 CHILE MAULE EARTHQUAKE

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

SEISMIC TESTING OF NON-STRUCTURAL COMPONENTS AND ASSESSMENT OF THE PRESCRIBED RESPONSE SPECTRUM

Module 7 (Lecture 24 to 28) RETAINING WALLS

Seismic Isolated Hospital Design Practice in Turkey: Erzurum Medical Campus

THE REPORT ON THE INVESTIGATION OF THE REACTORS AT FUKUSHIMA DAIICHI NUCLEAR POWER STATION (NO. 1)

Rehabilitation of a 1985 Steel Moment- Frame Building

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

DESIGN SPECIFICATIONS FOR HIGHWAY BRIDGES PART V SEISMIC DESIGN

Strength Evaluation by Load Testing

G. Michele Calvi IUSS Pavia

SIMULATING THE DYNAMIC RESPONSE OF DIVINE BRIDGES

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

SEISMIC RETROFITTING OF REINFORCED CONCRETE BUILDINGS USING TRADITIONAL AND INNOVATIVE TECHNIQUES

SEISMIC RETROFITTING OF STRUCTURES

MODELLING OF AN INFILL WALL FOR THE ANALYSIS OF A BUILDING FRAME SUBJECTED TO LATERAL FORCE

Comparison of Seismic Performance of D-region of Existing RC Structures Designed with Different Recommendations

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Chapter 15 Collision Theory

3. Observed Damage in Railway Viaducts

(1) Minami Nagamachi and Naka Nagamachi viaducts between Shiraishi Zao and Sendai Stations on the Tohoku Shinkansen line

Reinforced Concrete Design

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

DESIGN DRIFT REQUIREMENTS FOR LONG-PERIOD STRUCTURES

9.3 Two-way Slabs (Part I)

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

bi directional loading). Prototype ten story

Scope of Insurance Premium for Residential Houses against Seismic Risk in Japan

Chapter. Earthquake Damage: Types, Process, Categories

Rehabilitation of Existing Foundation Building to Resist Lateral and Vertical Loads

CLASSIFICATION BOUNDARIES FOR STIFFNESS OF BEAM-TO- COLUMN JOINTS AND COLUMN BASES

STUDY OF DAM-RESERVOIR DYNAMIC INTERACTION USING VIBRATION TESTS ON A PHYSICAL MODEL

NIST GCR Applicability of Nonlinear Multiple-Degree-of-Freedom Modeling for Design

Nonlinear Static Procedures on the Seismic Assessment of Existing Plan Asymmetric Buildings

METHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION

ANALYSIS AND DESIGN OF RC TALL BUILDING SUBJECTED TO WIND AND EARTHQUAKE LOADS

Prelab Exercises: Hooke's Law and the Behavior of Springs

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

INFLUENCE OF ENERGY DISSIPATING SYSTEMS ON THE SEISMIC RESPONSE OF CABLE SUPPORTED BRIDGES

Advanced Retrofitting Methods and Techniques for RC Building: State of an Art

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Building a simple seismometer

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

SEISMIC APPROACH DESIGN COMPARISON BETWEEN

ASSESSMENT AND RETROFITTING OF EXISTING RC BUILDINGS IN VIETNAM IN TERMS OF EARTHQUAKE RESISTANCES

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

Numerical modelling of shear connection between concrete slab and sheeting deck

New approaches in Eurocode 3 efficient global structural design

Technical Notes 3B - Brick Masonry Section Properties May 1993

SEISMIC DESIGN PROVISIONS FOR PRECAST CONCRETE STRUCTURES. S.K. Ghosh, Ph. D. President S.K. Ghosh Associates Inc. Northbrook, IL BACKGROUND

Cover. When to Specify Intermediate Precast Concrete Shear Walls Rev 4. White Paper WP004

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

2016 IDEERS Rules for Graduate Teams. The List of Rule Revisions

Technical Assignment 2 TABLE OF CONTENTS

Aim : To study how the time period of a simple pendulum changes when its amplitude is changed.

Concrete Frame Design Manual

Chapter 2 Basis of design and materials

How To Test For Earthquake Safety

Reinforced concrete moment-resisting frames are structural systems that work to

The Basics of FEA Procedure

SMIP05 Seminar Proceedings VISUALIZATION OF NONLINEAR SEISMIC BEHAVIOR OF THE INTERSTATE 5/14 NORTH CONNECTOR BRIDGE. Robert K.

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

CRACK DETECTION METHODS USING RADIO FREQUENCY IDENTIFICATION AND ELECTRICALLY CONDUCTIVE MATERIALS

A NUMERICAL ANALYSIS BASED SUBSTITUTE METHOD FOR SHAKING TABLE TEST IN CONSIDERING OF THE SOIL-STRUCTURE INTERACTION

Transcription:

Earthquake Yoshimura: Engineering Control and of Engineering Seismic Drift Seismology Demand for Reinforced Concrete Buildings with Weak First Stories 7 Volume 4, Number, September 3, pp. 7 3 Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories ) Manabu Yoshimura ) Department of Architecture, Tokyo Metropolitan University, Minamiosawa -, Hachioji, Tokyo, 9-3, Japan. ABSTRACT This paper studies seismic drift demand for RC buildings with weak first stories, the potential seismic vulnerability of which has been revealed in many past earthquakes including the 99 Kobe and 999 Chi-Chi earthquakes. In a building that collapsed during the Kobe earthquake the strength balance between the first story and the upper stories is shown to have had a significant effect on the collapse of this building. Nonlinear dynamic analyses are then conducted for a model representing weak-first-story buildings to study the first story drift demand, where the first-story strength and the strength balance along the height are taken as analysis variables. Based on the results, conditions that the two parameters should satisfy for controlling the first-story drift demand within an allowable level are discussed. INTRODUCTION Many RC buildings damaged in the 99 Kobe earthquake were constructed before 98, when Japanese building code requirements for the seismic design were extensively revised. However, even amongst RC buildings constructed after this code revision, some suffered severe damage, and most of them were weak-first-story buildings. In this type of building, few or no walls are provided at the first story, while many are placed in the upper stories. In consideration of the still remaining vulnerability of those weakfirst-story buildings, complementary provisions were added to the code requirements as an appendix in 997. The provisions require that weak-first-story buildings shall not suffer a first-story collapse. Such provisions lead to unreasonably large columns for the first story, nearly prohibiting the construction of such buildings. As recommended by many researchers, a total collapse mechanism design is desirable to control drift demand. However, it is unrealistic to design weak-first-story buildings so that the total collapse mechanism may result. To resolve this situation, development of a more rational design method is needed. Formation of the first-story collapse mechanism may be permitted as long as the first-story drift demand is controlled within an allowable level. A primary factor governing the first-story drift demand is the first-story strength itself. However, the strength balance between the first story and upper stories is also known to affect the first-story drift demand significantly [].

8 Earthquake Engineering and Engineering Seismology, Vol. 4, No. The first part of this paper introduces an example of a weak first-story building that collapsed during the Kobe earthquake, and highlights significant effects of the strength balance along the height on the first-story drift demand. In the second part, nonlinear dynamic analyses are conducted for a model representing weak-first-story buildings, where the first-story strength and strength balance along the height are taken as analysis variables. Presented also are conditions that the two parameters should satisfy for controlling the first-story drift demand within an allowable level..6 Slits 6.3.6 Y Y4 Y Y Y4.9 COLLAPSE OF WEAK-FIRST-STORY BUILDING DURING THE KOBE EARTHQUAKE.6 Building The building was a RC seven-story apartment complex without a basement. The first story was used exclusively for parking lots. Figures and show the plan views and framing elevation views 6.4. 4.6 Y Y Y4 : Slits Y. 7.3 Y Y3 Fig. Framing elevation views (X direction) Slits (a) First story (b) Second story and above Fig. Plan views of the north-south (X) direction, for which major damage occurred. The first story was nearly a pure moment-resisting frame, including only a short wall in the X3 plane. In contrast, the second story and above included two long walls in the X and X3 planes. In addition, they had a wall in the X plane that was designed as a nonstructural wall by being separated from the edge columns using slits. Details of the slit are shown in Fig. 3. The slit, although called so, did not perfectly separate the nonstructural wall from the edge column: the slit thickness, mm, was merely one third of the wall thickness, mm. It is widely acknowledged that slits whose thickness is less than half the wall thickness are ineffective, which implies that this nonstructural wall behaved as a structural wall. As will be discussed later, the existence of the nonstructural wall had a crucial effect on the seismic drift demand, and hence on the collapse of this building.

Yoshimura: Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories 9 X Plane [Unit: mm] Fig. 3 Observed Damage Details of slit Figure 4 shows residual lateral drifts and axial shortening observed at the first-story columns. The arrow in the figure indicates the amplitude and direction of the lateral drift. All columns were observed to move nearly to the north with extremely large lateral drifts ranging from 6 to 3mm (3mm on the average). The axial shortening was much larger for the north columns than for the south columns, apparently corresponding with the residual lateral drifts to the north. Photo shows observed damage to some of the first story members, where C and C8 represent the north and south columns. C crashed at the top while C8, although seriously damaged, avoided failure. The difference in the degree of damage between the two columns is related to the larger axial shortening sustained by the north columns relative to the south ones. The first-story wall in the X3 plane completely [Unit: cm] Upper number: Lateral drift Under number: Axial shortening Fig. 4 Observed Residual displacement of first story columns crashed at mid-height along with the edge column. On the other hand, practically no damage existed in members above the second-floor level, including the slits in the X plane. Thus, a first-story mechanism was formed for the X direction. Computed Drift Demand Nonlinear dynamic drift demand of this building was evaluated using the ground motions recorded near the building site. In the analysis, the X plane above the second floor level was modeled in two ways: first as the structural wall (Case ), where the slits were assumed ineffective, and then as the moment-resisting frame (Case ), where the slits were assumed effective. Analysis methods similar to those stated in later parts were (a) C (East face) (b) C8 (East face) (c) First story wall and C3 (West face) Photo Observed damage

used []. Maximum interstory drifts along the building height are compared in Fig.. The two results are quite different. For Case, almost all the drift concentrated in the first story, with a maximum story drift of mm (drift angle of 7.9%), while for Case such extreme concentration in the first story did not occur, with a maximum story drift of mm (drift angle of 3.%). The first story strength was the same for both cases, while the strengths in upper stories were larger for Case than for Case. These observations clearly indicate that the strengths of the second-story and above, or the strength balance between the first-story and upper stories, had a crucial effect on the seismic drift demand of this building. This issue is a major focus in a later section. It is also apparent from the above results that Case reproduced the damage observations reasonably, while Case underestimated the first-story drift demand significantly. This suggests that the building collapsed (at least partly) because the slits were ineffective. Problems in nonstructural walls are often addressed in view of their failure or their effect on the behavior of adjoining structural members. However, the existence of nonstructural walls can even affect the overall behavior of the building. CONTROL OF FIRST-STORY DRIFT DEMAND [3] Model Building and Analysis Methods The effect of the first-story strength and the strength balance on the first-story drift demand was examined for a model building, and conditions that these two parameters should satisfy for controlling the first-story drift demand within an allowable level are discussed. The model building was a 4-story RC wall-frame. Figures 6 and 7 show the plan views and framing elevation views of the X direction. This direction consisted of three cantilever walls (X, X4 and X8) continuous from the base to the top of the building and five weak-first-story frames (X, X3 and X to X7) with no wall at the first story but with walls in all upper stories. The model building, deemed a typical weak-first-story building in Japan, was designed according to pre-kobe (before 997) code requirements. The analysis methods were as follows. () The building was represented by a twodimensional plane frame comprising three cantilever walls and five weak-first-story frames. Each column was idealized as a line member, and each wall was modeled as a deep column located at the wall centerline. 7 X X X3 X4 X X6 X7 X8 Story 6 4 3 Case Case. 6.3 6.3 6.3 6.3 6.3 6.3 6.3 (a) First story Y X direction Y Y 3 Interstory drift (cm) Fig. Maximum interstory drift. 6.3 6.3 6.3 6.3 6.3 6.3 6.3 (B)(b) Second (B) story Floor and 階 以 above and 上 Fig. 6 Plan views Y

Fig. 7 Yoshimura: Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories 3 37.8 4. X そ Y Y Y Y Y Y X and X8 X4 Others Framing elevation views (X direction) () For columns, flexural nonlinearity was considered using two springs placed at both ends, the hysteresis of which was represented by the Takeda model [4]. For walls, flexural and shear nonlinearities were considered; flexural nonlinearity was represented by the Takeda model, and the shear nonlinearity by a origin-oriented model []. (3) Two ground-motion records were used for the dynamic analyses: the 99 Kobe (NS) record and 94 El Centro (NS) record. For both records, the ground-motion level was adjusted so that the maximum ground velocity would be m/s. This level is often used to represent severe earthquakes in Japanese seismic design. Damping was assumed to be of viscous type and proportional to the instantaneous stiffness with a damping ratio of 3% with respect to the fundamental natural frequency. The fundamental natural period of the building was sec. Analysis Variables The first-story strength and the strength balance between the first story and upper stories were taken as analysis variables. The first-story strength of the model was computed by adding up the smaller of the flexural or shear strength of each column or wall. Wall flexural strength was estimated by assuming a point of contra-flexure lying at the mid-height of the building. The same point of contra-flexure was used to estimate wall shear strength. The obtained story strength was expressed as the first-story shear coefficient (C ). Note that this procedure is adopted in the second level procedure for the seismic evaluation of existing buildings in Japan [6]. The strength balance of the model was expressed as the Strength Balance (SB) index, as defined below. First, the strength of each story was computed using the procedure stated above, and the respective story shear coefficients (C i, i = to n, n: number of stories; fourteen in this study) were obtained. Here the coefficient is defined as the strength divided by the weight that the concerned story carries. Second, C i is divided by the design shear coefficient distribution factor (A i, A =.) of the corresponding story. The factor, called the A i distribution and prescribed in the Japan s seismic code, specifies the design story strength distribution, given as the coefficient relative to the weight that the concerned story shall sustain. Third, SB is determined, given as a ratio of C / A at the first story to the minimum of all C i /A i at the second story and above. Note that SB is smaller than unity for ordinary weakfirst-story buildings and that C i / A i is generally minimal at the second story among the upper stories. With these in mind, SB is commonly expressed as: C / A SB = min( C / A ) i i i= n C / A = C / A () The mode of wall yielding, either shear or flexure, values of C i, A i, C i / A i for all stories, and the resultant SB are shown in Table. Here, C and SB were 7 and.89, respectively. Table Structural properties of model building Story Wall yielding C i A i C i / A i SB mode 4 Shear.36.76 3.7 3 Shear 4...3 Shear 3..86.6 Shear.7.69.34 Shear.8.7. 9 Shear.6.48.9 8 Shear.36.4.97 7 Shear.8.33.8.89 6 Shear.9.7 Shear 8..6 4 Shear 4..64 3 Shear..64 Shear.67..64 Flexure 7. 7

3 Earthquake Engineering and Engineering Seismology, Vol. 4, No. Parametric studies were carried out for different C and SB values. For each case, the member strength was determined to be equal to that of the original model multiplied by a factor of (C / 7) for members associated with the first story, and a factor of (C / 7) (.89 / SB) for the members for the upper stories. All other structural properties, such as the member stiffness and story mass, were assumed to be the same as those of the original model. Hence, the fundamental period was the same for all cases. Note also that the A i distribution was assumed to be the same for all cases. Effect of Strength Balance on First-Story Drift Demand To study the effects of the strength balance on the first-story drift demand, nonlinear dynamic analysis was conducted for cases with C being a constant value of.3 and SB ranging from to.. The maximum first-story drift, the sum of the maximum interstory drifts at the second story and above, and the maximum roof floor drift are shown in Fig. 8 for the El Centro record. As SB increases, the drift demand tends to decrease at the first story but increase at the upper stories. This trend is most pronounced for SB.8. The maximum roof floor drift demand is nearly unchanged with about mm or a slightly larger for SB.9. Pushover analysis was also conducted for comparison between the dynamic and static analyses. Lateral load distribution was taken to correspond to the A i distribution. The results attained up to a roof floor drift of mm are shown in Fig. 9 in the same form as for the dynamic results (Fig. 8). The static results were similar in trend to the dynamic ones; with the increase in SB, the drift demand tends to decrease at the first story but increase at the second story and above. Further, the trend is most pronounced for SB.9. The discussion to follow refers to the static results. Interstory drift versus story shear relations and associated yield conditions obtained from the pushover analysis are shown in Fig. for SB = and.8. For SB = (Point A in Fig. 9), the first-story drift demand is not reduced, while Story 層 せん shear 断 力 (kn) (kn Story 層 せん shear 断 力 (kn (kn) 4 3 3 4 3 3 Drift (cm) First story drift Sum of interstory drift at second story and above Roof floor drift 3 C =.3= El Centro.6.8.9 SB Fig. 8 Dynamic analysis (Maximum drift) First story drift Sum of intertstory drift at second story and above Roof floor drift Drift (cm) 3 CC=.3 =.3.6.8.9 SB A:SB = First story Second story and above 3 Interstory 層 間 変 drift 形 (%) (%) X, X4 and X8 Others :Flexure :Shear (a) SB = (Point A) B:SB = Second story First story Third story and above A Fig. 9 Pushover analysis (Roof floor drift = cm) 3 Interstory 層 間 変 drift 形 (%) B (b) SB =.8 (Point B) X, X4 and X8 Others :Flexure :Shear Fig. Pushover analysis (SB = and.8)

Yoshimura: Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories 33 for SB =.8 (Point B in Fig. 9) reduction is significant. For SB =, a complete first story mechanism was formed, with neither shear nor flexural yielding occurring at the upper stories, resulting in an extreme drift concentration on the first story. For SB =.8, a collapse mechanism was also formed above the third-floor level after the formation of the first-story collapse mechanism. This resulted in a drift on the first story remaining significantly smaller than that corresponding to SB =. Be reminded that the first-story strength was the same for both cases (C =.3). This reduction in drift indicates that the strength balance can have a significant effect on the first-story drift demand. Conditions Required to Control First-Story Drift Demand Within an Allowable Level To further study the effects of the two parameters, nonlinear dynamic analysis was carried out for various C and SB values. Relations between C, SB and the maximum first story drift are shown in Fig. for the El Centro record. As expected, the first-story drift demand decreases as C and/or SB is increased. The allowable first-story drift is commonly assumed to be % or %. Those values can be achieved if sufficient lateral reinforcement is placed at the first-story columns and walls. A set of C and SB values corresponding to the allowable drift can be obtained from Fig.. Resulting C -SB relations are shown in Fig.. Using these relations, we can determine C if SB is given, or vice versa, and the obtained set ensures that the first-story drift demand is within the allowable limit. However, the C -SB relations are not necessarily explicit in that SB itself includes C. For design purposes, relationships between C and C (required C -C relations) are much more practical. The relations between C and SB defined by Eq. () are shown in Fig. as a set of straight lines for various C values. The required C -C relations are obtained as the intersection of the required C -SB relations and these straight lines. For example, for the % drift, if C is., C is given as (C should be more than to meet the allowable drift requirements). Similarly if C is, C is given as.9 (C should be less than.9). Drift (%) C 4 3.3.4 C.8.6 C=.4.6 Fig. C -SB-first story drift relations (El Centro) C =..4.3....9 % %.3.6.8.9 Fig. Required C -SB relations (El Centro) SB.9 C=.9 4 3 SB Results of the required C -C relations are shown in Fig. 3 for the two ground-motion records and two allowable drifts. It turns out that C tends to decrease as C decreases, or C tends to increase as C increases, except for the case with the Kobe record and % drift, where C is nearly constant regardless of C. C determined from a given C value and C determined from a given C value are shown in Figs. 4 and for the % drift. It proves from Fig. 4 that C is as large as.67 for C =. (high), a slight reduction to.63 for C =. (medium), but becomes as small as.44 for C = (low). If only the first-story drift demand is of concern, apparently stories above the first should not be excessively strong. Figure also proves that C is as low as for C = (low), increasing to.9 for C =.6 (medium), and becoming as high as. for C = (high). In.8.6

34 Earthquake Engineering and Engineering Seismology, Vol. 4, No. this way, we can determine the required first-story strength from the given second-story strength and vice versa if the allowable drift is specified. C determined from a given C value is shown in Fig. 6 for % drift. C values are, and.39 for C =.,. and, respectively which are considerably smaller than those determined for the % drift. Naturally, the required first-story strength decreases for a large story drift. % % C El Centro Kobe......8.9.9. C = C =.6 C = Fig. C determined from C (Allowable drift = %).6. El Centro Kobe C C.4.4.34.39.4.3..3..9. C =. C =. C = C (a) El Centro Fig. 6 C determined from C (Allowable drift = %).6 CONCLUSION C C..8.6.4...4.3..3 Fig. 3 Required C -C relations.67.66. C (b) Kobe El Centro.6.63.9 Kobe.37.44 C =. C =. C = Fig. 4 C determined from C (Allowable drift = %) This paper examined the first story drift demand for weak-first-story buildings, the vulnerability of which was revealed during many past earthquakes, including the 99 Kobe and 999 Chi-Chi earthquakes. The major findings obtained from the studies are as follows. () The first story drift demand is governed not only by the first story strength but also by the strength of the upper stories and the strength balance between the first story and upper stories. () The first-story strength (in terms of the shear coefficient) required to limit the maximum first-story drift demand within % is.67,.63 and.44 for second-story strengths (also in terms of the shear coefficient) of.,. and, respectively. The required first- story strength decreases as the second-story

Yoshimura: Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories 3 strength decreases. If only the first story drift demand is of concern, excessive strength of the second story and above is not desirable for effective design. (3) When an allowable first-story drift of % is adopted, the required first-story strength is reduced to, and.39 for secondstory strengths of.,. and, respectively. REFERENCES. Yoshimura, M. and Kihara, S. (997). Displacement control of RC building with soft first story during severe earthquakes, Proceedings of the Japan Concrete Institute, Vol. 9, No.. pp. 8 86 (in Japanese).. Yoshimura, M. (997). Response of reinforced concrete building with soft first story subjected to 99 Kobe Earthquake, Proceedings of the Seventh International Conference on Computing in Civil and Building Engineering, Vol., pp. 8 9. 3. Iwase, H. and Yoshimura, M. (). Evaluation of seismic drift demand for RC buildings with weak first story based on story strength ratio, Proceedings of the Eleventh Japan Earthquake Engineering Symposium, pp. 67 7 (in Japanese). 4. Takeda, T., Sozen, M.A. and Nielsen, N.N. (97). Reinforced concrete response to simulated earthquakes, Journal of Structural Division, ASCE, Vol. 96, No. ST, pp. 7 73.. Hisada, T., Nakagawa, K. and Izumi, M. (96). Earthquake response of structures having various restoring force characteristics, Proceedings of the Japan Earthquake Engineering Symposium, pp. 63 68. 6. The Japan Building Disaster Prevention Association (). Seismic evaluation standards for existing reinforced concrete buildings (in Japanese).