IPS e.max CAD C16. Larger Size Block Low translucency Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2 Indicated for single unit restorations



Similar documents
CAD. Abutment Solutions. Instructions for Use. (for USA only) all ceramic all you need

CAD INSTRUCTIONS FOR USE CHAIRSIDE

Implant Abutments and Crowns on your CEREC. Welcome

the new dna of high strength glass ceramics

priti crown Your patients deserve you

Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.

IPS. Special Edition. Press-on-Metal Ceramic. Harald Gritsch Max Wörishofer Christoph Zobler

IPS Empress CAD for CAD/CAM technology Information for Dentists. Confidence. Reliability. Esthetics. Empress CAD. The world s leading all-ceramic

Class I and II Indirect Tooth-Colored Restorations

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

Press Abutment Solutions

Press INSTRUCTIONS FOR USE

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

InLine IPS. InLine. One. InLine. PoM. InLine. Instructions for Use IPS IPS IPS. Press-on-Metal ceramic. One-layer metal-ceramic

FAQs - RelyX TM Unicem 2 Automix/Clicker

WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca

CAD/CAM Block Overview Block-Übersicht

Jacket crown. Advantage : Crown and Bridge

Choosing the right type of abutment

Advances in All Ceramic Restorations. Alaa AlQutub Umm AlQura University, Faculty of Dentistry

Universal Crown and Bridge Preparation

CEREC inlab the multifunctional CAD/CAM system for modern dental restorations.

Your stepping stones to success.

Full Crown Module: Learner Level 1

The Attractive Glass Abutment System (ZX-27) HANDOUT

ZIRCONIA INFORMATION FOR DENTISTS. FAQ S from the dental practice ENGLISH

A complete system geared to your success.

portion of the tooth such as 3/4 Crown, 7/8Crown.

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

American Academy of Cosmetic Dentistry. Laboratory Technician Clinical Case Type II. One or Two Indirect Restorations

VITA YZ T / VITA YZ HT Working Instructions

New features DWOS 3.2

porcelain fused to metal crown

VITA ENAMIC for CEREC / inlab Working Instructions

Seeing CAD/CAM in a new light.

It s the Fuel For Your Success

stone model bonding tray improve the accuracy

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Biodenta CAD/CAM Case Report - Urs Brodbeck, DMD, Zurich, Switzerland. Monolithic Zirconia 12unit full-arch reconstruction

Removing fixed prostheses using the ATD automatic crown and bridge remover

Procedures & Products Powered by Procera. All-on-4

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

Cementation and Sterilization Guidelines for Labs and Dentists. Lava. Zirconia for Implant Abutments. Cementation and Sterilization.

Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy

Treatment planning for the class 0, 1A, 1B dental arches

Projecting a new smile from a facial photograph:

GARDEN WINDOW GLAZING AND DE-GLAZING INSTRUCTIONS

State-of-the-art for your prostheses

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Procedures & Products. NobelEsthetics

Healing Abutment Selection. Perio Implant Part I. Implant Surface Characteristics. Single Tooth Restorations. Credit and Thanks for Lecture Material

áå`çêáë=qwf MOKOMNS kéï=~ë=çñw= båöäáëü

VITABLOCS for CEREC /inlab Working Instructions

Aesthetics meets CAD/CAM in the dental surgery

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

Restoring Central Incisors

all ceramic all options

Increasing. VDO and the Use of CAD/CAM. Prosthodontic Principles and the Full-Mouth Reconstruction. 86 Summer 2013 Volume 29 Number 2

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

CAD/CAM Anterior and Posterior Implant Restorations: Ceramics, Abutments and Design

PureForm Ceramic System. Emulating nature. The perfect disguise.

Dental Bridges. What are they? What are the parts of a typical dental bridge (fixed)? When are dental bridges needed?

October 29, Dear Ms. Hartnett:

Composite artistry- speedy mock up

DLT 123 CROWN AND BRIDGE

CAD/CAM MATERIAL. ALL FROM ONE SOURCE.

VITA SUPRINITY Working Instructions

Build-up System. Color-Chart

Terms and conditions for teeth whitening offers

Telescopic Denture A Treatment Modality for Minimizing the Conventional Removable Complete Denture Problems: A Case Report

Woodlake Dental s Tray set up A Guide on How to Prepare Dental Procedure Trays.

Straumann Dental Implant System. Fax Order Form Collection.*

Managing worn teeth with composites

everstick everstick fibre reinforcements in orthodontics Clinical Guide Reliable anchorage Aesthetic retention everstick ORTHO

A collection of pus. Usually forms because of infection. A tooth or tooth structure which is responsible for the anchorage of a bridge or a denture.

In Class IV arch: Fulcrum line passes through two abutments adjacent to single edentulous space.

Dental Intelligence. dd TECHNIQUE. The Material. First Experiences with the One Body System IQ from GC

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

CAD/CAM. Solutions flexible, economical, future-proof

Precise. Powerful. Pure.

Zirconium Abutments for Improved Esthetics in Anterior Restorations

Restorative Guidelines

Structur 3. Gloss without polishing. Structur 3. Composite material for the fabrication of

Standard Test Procedures Manual

Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6

FORD DENTAL COVERAGE

Do s and Don ts of Porcelain Laminate Veneers

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

Replacement of Missing Teeth with Fixed Prostheses KEN HEMMINGS AND ZOE HARRINGTON

PRESS. Pressable Ceramic System. Perfect shades first time every time. Instruction Manual. Products for better dentistry

Handbook. Your guide to the Alberta Blue Cross. Dental Schedule

Optimet 3D Dental Multi-Facet Scanner Attainable Accuracy for Dental Application Cases

DENTAL ADVANTAGE HELPFUL HINTS FOR THE RDA PRACTICAL EXAM

ADA Insurance Codes for Laboratory Procedures:

Processing instructions Everest ZS-Blank. Always be on the safe side.

Managing a Case of Sensitive Abutment Situations through Use of a Fixed Movable Prosthesis A Clinical Report

Clinical randomized controlled study of Class II restorations of a highly filled nanohybrid resin composite (4U)

Implants in your Laboratory: Abutment Design

Transcription:

IPS e.max CAD C16

IPS e.max CAD C16 Larger Size Block Low translucency Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2 Indicated for single unit restorations Full and partial coverage single units Large canines Restorations over custom abutments

IPS e.max CAD 3-unit bridge

Instructions for Use Ordering # for Flow chart - 662640

Indications / contraindications Indications Up to three-unit bridges up to the second premolar as the abutment tooth Contraindications Inlay bridges Parafunction (e.g. bruxism) Cantilever bridges Maryland bridges Pontic width > 11 mm in the anterior region Pontic width > 9 mm in the premolar region Any other use not listed as an indication for IPS e.max CAD

Connector Dimensions Dimensions: 16 mm 2 Height >= Width Important: Currently, the new CEREC 4.2 software does NOT have a tool to measure the area of the connector The new E4D Software will have a measuring tool

Processing options

Staining technique using IPS e.max CAD Crystall

Staining technique Bridge after CAD/CAM milling approximately 8 minutes per unit = 24 minutes Actual times may vary Smooth out the attachment point and take proximal contacts into account.

Staining technique Do not use diamond discs for finishing, since this may result in predetermined breaking points. Finish interdental areas with fine-grit diamonds (grit size 40 50 µm). Make sure to observe the connector dimensions.

Staining technique Check occlusion, articulation and proximal contacts. Surface-grind the outer surface, particularly the functional areas of the restoration, with a fine diamond to smooth out the surface structure created by the CAD/CAM process.

Staining technique Use the largest possible IPS e.max CAD Crystallization Pin for crystallization. Fill the inside of the crowns of the previously cleaned bridge with IPS Object Fix Putty or Flow and press the appropriate IPS e.max CAD Crystallization Pin deeply into the IPS Object Fix material.

Staining technique Place the bridge on the IPS e.max CAD Crystallization Tray immediately. Smooth out displaced IPS Object Fix Putty or Flow with a plastic spatula from the margin towards the support pin so that the pin is secured in the paste and the crown wall is precisely supported.

Staining technique Clean off any possible residue adhering to the outer surface of the restoration with a brush moistened with water and then dry. Apply IPS e.max CAD Crystall./Glaze paste evenly to the blue restoration. Apply the mixed IPS e.max CAD Crystall./ Shades and Stains into the unfired IPS e.max CAD Crystall./Glaze paste.

Combination Firing Glaze & Crystallize P1 Use Program P1 Place the IPS e.max CAD Crystallization Tray with the glazed and stained restoration in the furnace and conduct the combination firing.

Correction Firing Use P1 Use Program P1 If adjustments are required (shade, glaze, contact points), conduct a separate corrective firing cycle on the IPS e.max CAD Crystallization Tray.

Staining technique Completed IPS e.max CAD LT bridge.

Firing parameters

Cementation

Conditioning of the restoration Do not blast the restorations with Al 2 O 3 or glass polishing beads. Etch with 5% hydrofluoric acid (e.g. IPS Ceramic Etching Gel) for 20 seconds and rinse the acid off with water.

Conditioning of the restoration Allow Monobond Plus to react for 60 s and then blow dry with the air syringe. Silanization is not required for conventional cementation procedures.

Dr. R. Watzke, Liechtenstein

Dr. R. Watzke, Liechtenstein

IPS e.max CAD 3 unit bridge, R. Watzke, Liechtenstein

IPS e.max CAD 3 unit bridge, R. Watzke, Liechtenstein

IPS e.max CAD IPS 3 unit e.max bridge, CAD 3 unit R. Watzke, bridge, Liechtenstein R. Watzke, Liechtenstein

CEREC Owner Needs to do a Bridge Software version 4.2 MCLX Mill

New Blocks for CEREC

all ceramic all options

Available Now New New

Coming

New Blocks for CEREC Key Points C16 & B32 will be at Patterson shortly Owners NEED software version 4.2 to be able to design and mill anterior bridges with the B32 block Stain, Glaze, & Crystallization process is similar to a single unit Crystallize & correction fire on P1 Cementation options

IPS e.max CAD Block Pricing IPS e.max CAD Qty per Refill Whlse Retail I12 5 $104.23 $161.50 C14 5 $104.23 $161.50 C16 5 $132.99 $205.00 B32 3 $214.83 $330.50 B40 current 3 $197.04 $280.00 B40L 3 $230.75 $355.00 A14 5 $199.49 $307.00 A16 5 $232.73 $360.00