PSI-DATA/FAX-MODEM/RS232



Similar documents
Telephone- and leased line modem for industrial applications TD-36

Rack mounted telephone- and leased line modem for industrial applications

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PHOENIX CONTACT - 03/2007

PSI-REP-PROFIBUS/12MB

Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS Wire Bus Systems PSI-WL-RS232-RS485/BT

MINI MCR-SL-R-UI(-SP)

Waveguide Access Point WGA631. Product Guide

Redundancy Module QUINT-DIODE/40

PCS0100en Persy Control Services B.V. Netherlands

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Digital input modules

Speed sensor MiniCoder GEL 247

TX OPEN RS232/485 module

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

PHOENIX CONTACT Features

Extract from the online catalog

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Quick Connect. quick - simple - efficient.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Voltage Regulator SPAU 341 C. Product Guide

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Communication Unit 560CMU05 Data sheet

PHOENIX CONTACT - 01/2007

RM4TG20 three-phase network control relay RM4-T - range V

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Disturbance Recoder SPCR 8C27. Product Guide

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Date Rev. Details Author

is then retained absolutely without interruption.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Safety technique. Emergency stop module BO 5988 safemaster

OZW30. Central Unit SYNERGYR

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

1701/22 FieldMonitor Management Interface Module

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

Modular I/O System Analog and Digital Interface Modules

3500/22M Transient Data Interface

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

80 Series - Modular timers 16 A. Features

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Three-phase monitoring relay CM-PFE

FOM-5A, 6A. Asynchronous Fiber Optic Modem

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

38 Series - Relay interface modules A

Foxboro Evo Process Automation System

R60 USB to CAN interface Manual (1.5 EN)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Agilent 87421A/87422A Power Supply

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Manual Serial PCI Cards

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

PSI-MOS-RS485W2/FO 850 T

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

DC Electronic Loads 8500 series

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

MagIC Installation Manual. Point of Sales Terminals TD06014B

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

AC3200 INTELLIGENT BROADBAND AMPLIFIER

IntesisBox KNX Mitsubishi Heavy Industries AC

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

DMX2PWM 9 Channel Dimmer Setup Manual

38 Series - Relay interface modules A

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Remote Monitoring and REC 501 Control Unit Product Guide

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

USB VoIP Phone Adapter. User s Manual

RealSSD Embedded USB Mass Storage Drive MTFDCAE001SAF, MTFDCAE002SAF, MTFDCAE004SAF, MTFDCAE008SAF

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Transcription:

Industrial analog modem INTERFACE Data sheet 100500_en_01 PHOENIX CONTACT - 10/2008 1 Description The DIN rail-mountable PSI-DATA/FAX-MODEM/RS232 is specifically designed to meet industrial requirements for remote maintenance. It provides global access to machines and systems via permanent and dial-up line connections according to the V.34 standard. A wide range of security functions, such as adjustable selective call acceptance, connection establishment with password protection, and call-back function, protect the system against unauthorized access. One particularly useful feature for remote system monitoring is the configurable warning or alarm input. If this input is activated, the modem calls a user-defined number and sends a stored text message by fax or SMS. To ensure interference-free operation even in harsh EMC conditions, the device has high-quality 3-way isolation and integrated surge protection. The modem also features an integrated automatic "Sleep" function to increase battery life and an extremely wide supply voltage range of 10 V to 60 V, making it suitable for universal use. Modem startup is very easy using plug and play and user-friendly configuration software. The modem is approved for use in public telephone networks in Europe, the USA, and Canada. Additional approvals can be provided on request. ATTENTION: The PSI-DATA/FAX-MODEM/RS232 is designed exclusively for SELV operation according to IEC 60950/EN 60950/VDE 0805. The modem must only be connected to devices, which meet the requirements of EN 60950 ("Safety of Information Technology Devices"). If you have any technical problems, which you cannot resolve with the aid of this documentation, please contact us during the usual office hours at: Phone: +49-52 35-31 98 90 Fax: +49-52 35-33 09 99 E-mail: interface-service@phoenixcontact.com Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.com. This data sheet is valid for all products listed on the following page:

2 Ordering data V.34 modem: Industrial analog modem, DIN rail-mountable, dial-up and permanent line operation in Europe, USA, Canada, V.24 (RS-232) interface, 3-way isolation, alarm I/O, 24 V AC/DC supply voltage Scope of supply: Modem, CD with configuration software and user manual, and RJ12 cable PSI-DATA/FAX-MODEM/RS232 2708203 1 General accessories DIN rail bus connector (3 required) ME 17,5 TBUS 1,5/ 5-ST-3,81 GN 2709561 1 System power supply unit Primary-switched Input voltage range Nominal output voltage Nominal output current 45 Hz... 65 Hz 85 V AC... 264 V AC 24 V DC ±1% 1.5 A Surge protection for analog telecommunications interfaces, DIN railmountable PSI-MODEM-SPLITTER, switching module to access two control systems via one modem MINI-SYS-PS-100-240AC/24DC/1.5 2866983 1 MT-2FM-RJ12 2838937 1 PSI-MODEM-SPLITTER 2708766 1 Cables/conductors Connecting cable, 9-pos. D-SUB to USB, with 9-pos. D-SUB to 25-pos. D-SUB adapter Short V.24 (RS-232) flat-ribbon connecting cable between modem and PSI-MODEM-SPLITTER V.24 (RS-232) cable, 0.5 m, 9-pos. D-SUB female connector to 9-pos. D-SUB female connector V.24 (RS-232) cable, 2 m, 9-pos. D-SUB female connector to 9-pos. D-SUB female connector CM-KBL-RS232/USB 2881078 1 PSI-CA-MODEM-SPLITTER 2311425 1 PSM-KA9SUB9/BB/0,5METER 2708520 1 PSM-KA9SUB9/BB/2METER 2799474 1 Adapters PSM-AD-D9-NULLMODEM, RS-232 (V.24) null modem connector, 9-pos. D-SUB female connector to 9-pos. D-SUB male connector Adapter cable for connecting the IB IL RS232 and IB IL RS232-PRO Inline communication terminals MPI adapter for coupling to the programming interface of a SIMATIC S7-300/400 controller PSM-AD-D9-NULLMODEM 2708753 1 PSM-KAD-IL RS232/9SUB/B/0,8M 2319200 1 PSI-MPI/RS232-PC 2313148 1 Documentation User manual for the industrial analog modem PSI-DATA/FAX-MODEM/RS232 UM E 2699354 1 100500_en_01 PHOENIX CONTACT 2

3 Technical data Power supply Supply voltage 1 10 V DC... 60 V DC, 16 V AC... 40 V AC Via COMBICON plug-in screw terminal block Frequency DC or 50 Hz... 60 Hz Supply voltage 2, alternative or redundant 24 V DC ±5% Via backplane bus contact and system power supply Current consumption Nominal operation Sleep mode (can be configured via software) LED indicator < 100 ma at 24 V < 40 ma at 24 V VCC (green LED): Steady light: Operation Flashing: Sleep mode V.24 (RS-232) interface Connection 9-pos. D-SUB pin strip Device type Data Communication Equipment (DCE) Data format Serial asynchronous UART/NRZ Encoding 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length Serial transmission speed Automatic data rate detection (default) or fixed setting at 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (adjustable via software) Data flow control LED indicator/data indicator LED indicator/control signal indicator Software handshake: Xon/Xoff Hardware handshake: RTS/CTS No handshake or 3964R TD (green LED), data to modem (dynamic) RD (yellow LED), data from modem (dynamic) DTR (yellow LED), Data Terminal Ready DCD (yellow LED), Data Carrier Detect PSTN port (a/b line) Connection RJ12, 6-pos., or COMBICON plug-in screw terminal block Shield DC coupled to DIN rail Operating modes Dial-up modem, 2-wire half/full duplex Fax modem, 2-wire half duplex Permanent line, 2-wire full duplex Dialing procedure Multiple frequency/pulse dialing, configuration via software Transmission speed DCE/DCE Fax Automatic adjustment according to V.8 300 baud to 33.6 kbaud 2400 baud to 14.4 kbaud Compatibility ITU V.42bis, V.42, V.34 extended, ITU V.32bis, V.32, V.21, V.22bis, V.22, V.23, Bell 212A and 103, ITU V.17, Group 3 T.4, T.30, and EIA TR-29 Fax compatibility EIA TR-29 Class 2, CCITT V.17, Group 3, V.29, V27ter Command set compatibility AT standard command set and extended, V.250 basic command set Error correction V.42 (LAP-M or MNP 2 to 4) Data compression V.42bis (throughput 4:1), MNP 5 (throughput 2:1) 100500_en_01 PHOENIX CONTACT 3

PSTN port (a/b line) (continued) LED indicator/data indicator Acoustic signaling Startup diagnostics Adaptive line test Telecommunications approvals Hardware settings Green LED (OH), off the hook Yellow LED (AA), automatic answer, flashes during selective call acceptance Yellow LED (FAX), fax mode active Yellow LED (EC), error correction in V.42 mode, flashes when data compression is active Integrated piezo Power on selftest, visualization via LEDs (controller, SRAM, EEPROM, DSP) Dial tone test, pulse dial ring test via additional function in configuration software TBR21, TBR15, TIA/EIA/IS-968 for Europe, USA, and Canada 4-pos. DIP switch for dial-up and permanent line operation (under removable cover) Switching input and output Switching input Switching output Signaling U N 24 V DC/5 ma, 9 V DC... 48 V DC input voltage range, floating, activates one or more of the following: Message to the local V.24 (RS-232) interface SMS (only in dial-up operation) Fax (only in dial-up operation) Output control at the remote station (via SMS) 60 V DC/1 A or 42 V AC/1 A miniature switching relay, N/O contact, activated by: Input control at the remote station SMS (only in dial-up operation) Local AT command AT command at the remote station ALR (red LED) Flashing: SMS/FAX error message to be sent Steady light: Alarm has been triggered ERR (red LED) Steady light: Alarm cannot be triggered Reset (acknowledgment) by: SMS (remote) AT command (local + remote) Button (local) Text and telephone number memory Text memory SMS Fax Telephone number memory 160 characters 480 characters, 30 KB 20 telephone numbers with a maximum of 36 digits 100500_en_01 PHOENIX CONTACT 4

General data CE conformance EMC directive 89/336/EEC Approvals u Ex: u Ambient operating temperature range 0 C 55 C Housing ME 35 with 5-pos. bus contact and ground contact Material Dimensions (H x W x D) Weight of device Functional earth ground ABS-V0, green 99 x 35 x 114.5 mm 165 g Housing contact with DIN rail Vibration resistance According to DIN EN 60068-2-6 5g, 1.5 h each in x, y, and z direction Shock test Operation Storage Free fall Degree of protection 3-way electrical isolation Test voltage According to DIN EN 60068-2-27 15g, 11 ms, half-sine shock pulse 30g, 11 ms, half-sine shock pulse According to IEC 60068-2-32 from a height of 1 m (without packaging) IP20 Power supply // PSTN // V.24 (RS-232) 1.5 kv AC, 50 Hz, 1 min. between all ground levels according to EN 50178 and EN 61131-2 Electromagnetic compatibility Noise immunity according to EN 61000-6-2 1 Electrostatic discharge (ESD) EN 61000-4-2 Criterion B 2 Electromagnetic HF field Amplitude modulation Pulse modulation Fast transients (burst) Signal Power supply 8 kv air discharge 6 kv contact discharge EN 61000-4-3 Criterion A 3 EN 61000-4-4 10 V/m 10 V/m Criterion A 3 1 kv/5 khz Criterion A 3 2 kv/5 khz Surge current load (surge) Signal Power supply EN 61000-4-5 Criterion B 2 1 kv 2 kv Conducted interference EN 61000-4-6 Criterion A 3 10 V Noise emission EN 55022 Limiting curve B 1 EN 61000 corresponds to IEC 1000 2 Criterion B: Temporary adverse effects on the operating characteristics which the device corrects automatically. 3 Criterion A: Normal operating behavior within the specified limits. 100500_en_01 PHOENIX CONTACT 5

4 Features For universal use Password-protected access/ call-back function/selective call acceptance Configurable input and output Alarm sent directly by SMS or fax via the integrated switching input (or via AT commands) Sends, receives, and evaluates SMS messages Wide supply voltage range of 10 V DC... 60 V DC or 14 V AC... 40 V AC Power-saving sleep mode High-quality three-way isolation (VCC // V.24 (RS-232) // PTSN) Integrated surge protection Easy startup using plug and play and user-friendly configuration software 3964R-compatible 5 Application The PSI-DATA/FAX-MODEM/RS232 modem can be used universally and internationally for all popular modem applications in the following operating modes: Dial-up modem Fax modem Permanent line modem For remote monitoring of systems and machines For remote control For system diagnostics For production data acquisition For automatic alarm generation This device is approved for operation in the following public telephone networks: Belgium Denmark Germany France Finland Greece Great Britain Italy Ireland Canada Luxembourg The Netherlands Norway Austria Portugal Sweden Switzerland Spain USA Approvals for other countries are available on request. 100500_en_01 PHOENIX CONTACT 6

Telephone network (PSTN) Figure 1 Dial-up operation 20 km Figure 2 Permanent line operation Telephone network (PSTN) Figure 3 Alarm generation 100500_en_01 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany Phone: +49-52 35-30 0 7 PHOENIX CONTACT P.O.Box 4100 Harrisburg PA 17111-0100 USA Phone: +717-944-1300 www.phoenixcontact.com