Administrative Schritte zu Konformitätsuntersuchungen. in Zeiten der Globalisierung Beispiel China



Similar documents
New OIML Document Surveillance of utility meters in service based on sampling inspections

Experience with taximeters with a look at the corresponding tables

Measuring Instruments Directive (2004/22/EC) Implementation and Application. Christian Mengersen (PTB, Germany, WG Q.31 Legal Metrology )

WELMEC European Cooperation in Legal Metrology

WELMEC European cooperation in legal metrology

Guidelines on the Reporting of Compliance with Specification

Experiences with novel developed secondary conductivity sensors within the German Calibration Service (DKD)

Check-list for auditors. Audit visit at candidate registered laboratories

COOMET REPORT 50 th CIML Meeting October 2015, Arcachon, France

Measuring equipment in a laboratory.

Using Equotip Hardness Test Blocks Abstract 1. Introduction 2. Verification of Leeb hardness testers according to standards

OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

The Radon Calibration Laboratory at the Federal Office for Radiation Protection (BfS)

What is ATEX? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Keywords: Torque, calibration, uncertainty, torque tools, torque testers. Contents

IT Security Standards and Legal Metrology Transfer and Validation

GUIDANCE ILAC-G24 INTERNATIONAL OIML D 10 SERIES Edition 2007 (E) DOCUMENT Edition 2007 (E)

Accreditation according to ISO/IEC in Europe. Historic EA Europeing Accreditation Assessment Experience from Technical assessment

Federal Institute for Materials Research and Testing (BAM) Pyrotechnics Division 2.3 Explosives D Berlin Berlin,

TC TrustCenter GmbH Time-Stamp Practice and Disclosure Statement

Concept for a cryptographic infrastructure for measurement components in smart grids

INDUSTRIAL SERVICES PRESSURE EQUIPMENT CERTIFICATION (PED) Pressure equipment certification. Your key to market access in Europe.

Module Makers Perspective International PV Module Quality Assurance Forum San Francisco, USA

(Uncertainty) 2. How uncertain is your uncertainty budget?

WELMEC. European cooperation in legal metrology

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

Concept for an Algorithm Testing and Evaluation Program at NIST

Calibration method for conductivity cells

Test equipment for temperature and its reduction

TCR easy Plus Alarm. Operating Instructions

Certificate: / 29 April 2014

Calibration Certificate

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19

Technology: Heating, Ventilation and Air Condition (HVAC) Zone Controls

Basic Steps to Establish ISO/IEC Compliant Testing Laboratories

Gas Smart Metering System

Angle metrology at the PTB: current status and developments

Standards for smart grids with emphasis on their realization in remote and rural areas

Measuring instruments in industry.

SCHATZ - TEST Tool testing systems. SCHATZ -certest-w. Dynamic testing of torque tools

NVLAP Assessor Training. Assessor Qualification & Training Requirements

Calibration of flow meters for liquids and gases

Energy Management Systems. Motor Summit 2012

Final Publishable JRP Summary Report for JRP ENG06 Power Plants Metrology for improved power plant efficiency

FACOGAZ Association of European Gas Meter Manufacturers

Technische Universität Braunschweig.

Company name Date submitted. Building address City State ZIP. * Building Sq. Ft.

How To Test A Titrette And Digital Burette

Guidelines on the Calibration of Static Torque Measuring Devices

Negative gauge pressure comparison

Certificate: / 29 April 2014

MEDEA: Metrology Enabling Developing Economies in Asia. Training Course on the Verification of Fuel Dispensers

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications

Ramon 2.2 Radon-Monitor

INTEROPERABILITY UNIT

ramon 2.2 Radon Monitor manual

DENSITY MEASUREMENTS OF LIQUID FUELS TO DETERMINE TEMPERATURE CONVERSION FACTORS FOR LEGAL METROLOGY

Certificate: / 20 August 2013

Measurement Canada. Presentation to Ontario Smart Grid Working Group. Who is Measurement Canada?

Environment-Laboratory Ambient Conditions

USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION

FMC Technologies Measurement Solutions Inc.

WP 5 Pilot projects implementation and evaluation

Standardizing contactless communication between ticketing equipment and fare media Transport Ticketing 2014

Open for BACnet BACnet the global standard

Flow Metrology for Liquefied Natural Gas (LNG)

DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: GM32 ln-situ-gasanalysator model Cross Duct for NO and S02

Certificate: _01 / 29 April 2014

An Introduction to ATEX -

KALIBRERINGSBEVIS. 25 temperature loggers Ecoguard model TS , identification se table of results.

accreditation will it still be needed or will other schemes show up?

RULES FOR THE PARTICIPATION IN INTER- LABORATORY COMPARISONS AND PROFICIENCY TESTING SCHEMES

Maintenance in instrumentation Maintenance with concept and technology focusing on results

NEW AND GLOBAL + OLD APPROACH PRODUCT LEGISLATION: A. Standard questionnaire to be filled for each sector individually:

Method to Calculate Uncertainties in Measuring Shortwave Solar Irradiance Using Thermopile and Semiconductor Solar Radiometers

A Revised EMC Directive from Europe

7 th Conference on Flat Bottom Tanks International

INSTITUTE FOR TESTING AND CERTIFICATION, Inc. ITC Client s Guide. Provision of Gaming Machine Certification Services

Gravimetric determination of pipette errors

NEW AND GLOBAL + OLD APPROACH PRODUCT LEGISLATION: A. Standard questionnaire to be filled for each sector individually:

R&S ZCxxx Millimeter-Wave Converters Specifications

thermal Conductivity Testing in Europe - A Review

Length measuring instruments

TÜV Rheinland Lichttechnik GmbH. Laboratory for testing of lighting devices

PN / Report PER about the mission from 11 th 15 th Nov 2012 at Lima - Peru

Cryptography in Metrology

RESIDENTIAL HEAT PUMPS AS FLEXIBLE LOADS FOR DIRECT CONTROL SERVICE WITH CONSTRAINED PAYBACK

SIMAIN - Energy Optimization. A holistic approach to cut energy costs sustainably. April Siemens AG All Rights Reserved.

Thermostat with display

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

'INSIZE' is becoming an international brand.

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

2.12. page Products for Explosion hazardous Environment

EA Document on. Accreditation. For Notification Purposes

EN Type Approval & Certification of AMS (QAL1)

Traceable cantilever stiffness calibration method using a MEMS nano-force transducer

EUROLAB 25 years. The role of metrology and testing to characterize materials and products. EUROLAB 25th Anniversary Seminar

Transcription:

PTB 18. - 20.9.2013 Seeon 9. Internationale EMATEM Sommerschule Administrative Schritte zu Konformitätsuntersuchungen in Zeiten der Globalisierung Beispiel China Dr. Jürgen Rose Fachbereich Wärme und Vakuum, Leiter AG Messung thermischer Energie juergen.rose@ptb.de

PTB Conformity assessments of heat meters, sub-assemblies and combinations thereof according to European Directive on Measuring Instruments (MID) Dr. Jürgen Rose, Department Heat and Vacuum of PTB, Head of Working Group Thermal Energy Measurement Head of CEN TC 176 WG2, Member TC 11 OIML, WELMEC WG 11 Head of German WG Heat Metering juergen.rose@ptb.de

Topics PTB Presentation I What is National Metrology Institute of Germany Consumption heat meters in Europe Presentation II Trends in heat metering processes Presentation III Basic for selling of consumption meters in Europe: Conformity Assessments according to European Directive on Measuring Instruments (MID) Presentation IV Testing Procedures and Harmonized Standards Estimation of measurement uncertainties Presentation V Notified Bodies in Europe Administrative steps to get EC-Type Examination Certificate for MID - Module B (e.g. at PTB)

http://www.ptb.de/en/org/q/q3/q32/_index.htm Look at PTB internet homepage - Certification body -

Main steps - conformity assessments at Notified Body PTB 1. Fill application for Conformity Assessement according to MID - Module B, formless, with your official signature, signet and with declaration, that only PTB will be charged as Notified Body, briefly introduce the meter All this send through the post to official address: Dr. Harry Stolz Physikalisch-Technische Bundesanstalt, Bundesallee 100 38116 Braunschweig - Germany NOTE: Modul B certificates are not enough to come into EC-market! + Modul D or + Modul F or + Modul H1 needed 2. Wait for hints and instructions, accept PTB s General Terms and Conditions of Certification (AZB) of Physikalisch-Technische Bundesanstalt for product certifications and QA approvals and General Terms and Conditions of Business (AGB) for conformity assessments, testing, measuring and calibration services 3. You will be informed about responsible persons - charged with assessments 4. If they are able to handle, wait for instructions about prepayment with invoice information Please Note Prepayment acc.to PTB s invoice to 100 % is necessary. Consequently it s only allowed, to start conformity assessments, when PTB received prepayment. Calculations: acc.to preliminary estimation of worktime, about 117 /hour (for testing, assessments and inluding MID Type Examination Certificate, if positively examinated) Summarized for Heat meters, max. 25 000, needed time interval about 3 monthes This is only for orientation, no fixed price and without any warranty! PTB will payback money in case of reduced efforts with detailed accountings

Harmonized Standards and Normative Documents

Related aspects of acceptance of test results done by manufacturer opportunities (1)

Related aspects of acceptance of test results, opportunities (2) If sub-assemblies of heat meters have already separated MID Type Examination Certificates - Module B (issued by an European Notified Body, added by MID Conformity based on Production Control - Module D ): -> Then these assemblies will not be subject of conformity assessments. e.g.: temperature sensor pairs Test results done by manufacturer are helpful in principle : There is no must for acceptance by Notified Bodies! Test results, supervised by e.g. ILAC International Laboratory Accreditation Cooperation, added by disclosed measurement uncertainty estimations acc.to ISO/BIPM Guide to Expression of Uncertainty in Measurement (GUM), with conformity assessments acc.to ISO 17025, 9001 series create faithful relation to manufacturer s test results. Please Note: Send all of test results you have, supervised documents, uncertainty estimations as original documentated and signated to your Notified Body. It could be helpful to reduce efforts, money and assessment time.

At first step, manufacturer will get a draft of certificate with possibility to comment this

PTB Conformity assessments of heat meters, sub-assemblies and combinations thereof according to European Directive on Measuring Instruments (MID) Thank you good bye good day Dr. Jürgen Rose, Department Heat and Vacuum of PTB