Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors



Similar documents
Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

P66 Series Electronic Fan Speed Controls

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

P70, P72, and P170 Series Controls for Dual Pressure Applications

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

V46 Pressure-Actuated Water-Regulating Valve

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

A99B Series Temperature Sensors

G670 Intermittent Pilot Ignition Controls

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

T5000 T000 LCD Digital Fan Coil Thermostat

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Operating instructions

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

ECOCIAT. Domestic hot water heat recovery unit

FX07 Field Controller

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Electronic Pressure Switch EDS 300

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

! WARNING. Before using product, read and understand instructions.

Proportional pressure regulators VPPE

Digital Controllers ACTUATOR COMPATABILITY

D A T A S H E E T. PS3 Pressure Switch. Alco Controls PS3

Duct Humidity Transmitter

Cisco TelePresence MCU 4500 Series safety and compliance information

IntesisBox KNX Mitsubishi Heavy Industries AC

AIR-CONDITIONER SPLIT TYPE

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Electronic Control Devices The European Product Catalogue 2007

IntesisBox Modbus Server SAMSUNG Air Conditioners

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

ST Series POWER SUPPLIES USER INSTRUCTIONS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

IntesisBox KNX LG Air Conditioning

Micro Motion 3098 Gas Specific Gravity Meter

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

V47 Series Temperature Actuated Modulating Water Valves

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

aseries A13B Mini Bullet Camera User Manual

FX07 Field Controller

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Proximity Switches RS (Reed Switch)

Agilent 87421A/87422A Power Supply

Pressure Switch for gas and air

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

3 Port Solenoid Valve

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

VG2000 Series Cast Iron Flanged Globe Valves

Digital inductive conductivity transmitter

, User s Manual

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

RRV934. Multi-controller. Synco living

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

New XUY roller sensors

4 Posiflow Proportional Solenoid Valves

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

MP8000 Series Pneumatic Valve Actuators

How To Use A Flowmeter

How To Read A Pipe From A Sensor

A project to optimise quality and energy efficiency must include metering

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

SunMaxx Solar Filling Station Operating Instructions

KNX Panasonic Air Conditioners

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Operating Manual UWAPS-TINY Series

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Thyristor-controlled power supplies and battery chargers

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Description. Dimensions. Features. precision works better

Original instructions Tina 3A/Aps Adaptor unit

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

GenStore Archive Cabinet

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

System 350 A350E Electronic Cooling Control

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

Transcription:

European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors Introduction The Series P215PR/RM direct-mount and remotemount pressure-actuated condenser fan speed controllers are designed for speed variation of singlephase motors. Head pressure control of a refrigeration system, through speed variation of the fan on an air-cooled condenser, results in optimum performance throughout the year. Once the output drops below 30%, the fan is cut off. The Series P215PR/RM controllers are designed for noncorrosive refrigerant systems. See Table 1 for a list of features and benefits. A pressure-actuated control provides the most direct and fastest response to pressure variations in the refrigerant system. The controller varies the supply voltage to the motor from 30% to at least 95% over the proportional band using the phase-cutting principle. This principle provides speed variation of a permanent split capacitor or shaded pole motors that do not draw more than 4 A (RMS) full-load current. The motor manufacturer should have approved the product for this speed control principle. We recommend confirming with the electric motor manufacturer that the motor can be used with a controller, using the phase-cutting principle for speed variation. You can also provide a copy of this product data sheet to the motor manufacturer or supplier for review. Figure 1: P215PR Direct-Mount Pressure- Actuated Condenser Fan Speed Controller Figure 2: P215RM Remote-Mount Pressure- Actuated Condenser Fan Speed Controller Table 1: Features and Benefits Feature Fan Speed Variation Condenser Pressure Control Pressure Input Direct Mount Option Remote Mount Option Setpoint Screw Location on Top of Device Built-in Suppression Filter IP65 Enclosure Compact Design Attractive Styling Quick Connector Plug Included Style 5 Remote Mount Pressure Range 5-42 bar Benefit Creates optimum condenser pressure control all year round and reduces noise during colder periods (such as nights). Allows direct and fast response to pressure variations. Allows for easy installation. Creates flexibility in mounting location. Allows for easy setpoint adjustment after installation. Meets electro-magnetic compatibility requirements. Allows for controller mounting outdoors. Fits into small units and has a small turnaround circle. Upgrades your equipment. Allows for easy wiring and quick replacement. Enables direct connection with flexible refrigeration hose. Allows compatibility with all HFC types from R134a to R410a. 2013 Johnson Controls, Inc. Catalogue Section 4 Order No. PD-P215PR-E

IMPORTANT: Use this Series P215PR/RM Pressure Actuated Condenser Fan Speed Controller only as an operating control. Where failure or malfunction of the P215PR/RM could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the P215PR/RM Controller. Installation The controller must be mounted in an upright position on the refrigerant line, preferably at the condenser outlet side, to reduce pressure pulsation as much as possible. Mount the controller within a 45 angle on both sides of the top of the high pressure line to avoid accumulation of oil inside the controller bellows and maintain the class IP65 rating. See Figure 3. If you are using a pump-down system, the controller connection must be made at the high-pressure side of the system and upstream from the solenoid valve to avoid low pressure during pump-down. The controller (IP65) can be mounted outdoors. When mounted inside a cabinet, holes for air circulation must be provided. Figure 4: Wiring Details! WARNING: Risk of Electric Shock. Disconnect or isolate all power supplies before making electrical connections. More than one disconnect or isolation may be required to completely de-energize equipment. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death.! CAUTION: Risk of Property Damage. Do not apply power to the system before checking all wiring connections. Short circuited or improperly connected wires may result in permanent damage to the equipment. Figure 3: Mounting Position Range Wiring The built-in EMC filter is designed for a maximum distance of 2 meters between the controller and the motor. Non-shielded cable must be used. The rubber gasket must be placed between the quick connector plug and the controller terminals to keep the IP65 protection class. See Figure 4 for wiring details. Electro-Magnetic Capability The controller includes a built-in suppression filter and meets required (EC) directives. However, when two or more Electro-Magnetic-Compatibility (EMC) compliant components are combined, the entire system may not be compliant. It is the end user s responsibility to make the entire system compliant. Multiple motors can be wired in parallel, provided that the total current does not exceed the maximum limit. Measuring Use a True RMS meter for measuring amperes or volt values. 2 P215PR/RM Series Pressure Controllers

Adjustments The setpoint is defined at 90% output value. The fixed cut-off value is 30% of the supplied voltage. Both the load and the supply voltage can affect the controller characteristic. Setpoint The pressure setpoint at which your equipment operates can be adjusted by using the setpoint adjusting screw. See Figure 6. Figure 6: Setpoint Adjustment Screw The setpoint is factory set at the values shown in the following table. Control Range Range 5 to 15 bar Range 10 to 25 bar Range 22 to 42 bar Factory Setpoint 9 bar 19 bar 26 bar Figure 5: VDC Output Relative to Pressure Input The proportional band is fixed and defined as the pressure difference between the points where the output values are 30% and 90% of the supply voltage. See Figure 5. Proportional Band Range (bar) 5 to 15 10 to 25 22 to 42 3.0 ± 0.7 4.5 ± 1 5.5 ± 1.5 Repair Information If a Series P215PR/RM Condenser Fan Speed Controller fails to operate within its specifications, replace the unit. For a replacement Series P215PR/RM, contact the nearest Johnson Controls representative. Provide the model number of the control when ordering a replacement. This number is found on the data plate. See Table 2 on page 4 for the Product Selection Chart. The values indicated are shown at 50 Hz power supply. At 60 Hz power supply, the cut-off and proportional band values decrease by 15%. A built-in (fixed) hysteresis is included in the controller. This hysteresis is not indicated in the control characteristic, but is included in the proportional band. P215PR/RM Series Pressure Controllers 3

Table 2: Product Selection Chart Product Code Number Range (bar)* Element Style Setting (bar) Prop. Band (bar) Minimum Shipping Quantity Additional Features P215PR-9200 10 to 25 47 19 4.5 1 P215PR-9202 22 to 42 47 26 5.5 1 P215PR-9203 5 to 15 47 9 3.0 1 P215PR-9800 10 to 25 28 19 4.5 1 P215PR-9230 10 to 25 47 19 4.5 25 Bulk Pack P215PR-9232 22 to 42 47 26 5.5 25 Bulk Pack P215PR-9233 5 to 15 47 9 3.0 25 Bulk Pack P215PR-9250 10 to 25 47 19 4.5 15 P215RM-9700 10 to 25 5 19 4.5 1 P215RM-9702 22 to 42 5 26 5.5 1 P215RM-9703 5 to 15 5 9 3.0 1 *1 bar = 100 kpa 14.5 psi Pressure Connections and Dimensions There are three types of pressure connections available. See Figure 7. Bulk Pack, 2 m cable connector included Turnaround Circle 65 Turnaround Circle 65 Turnaround Circle 100 117 196 166 26 14 30 75 106 30 15 109 Ø4.5 HEX 19 42.5 Figure 7: Pressure Connection Types: Style 47 (Left), Style 28 (Middle), Style 5 (Right), Dimensions, mm 4 P215PR/RM Series Pressure Controllers

Technical Specifications P215PR/RM Pressure Actuated Controllers Product P215PR/RM Pressure-Actuated Condenser Fan Speed Controllers Pressure Range 5 to 15 bar 10 to 25 bar 22 to 42 bar Maximum Overrun Pressure 5 to 15 bar = 25 bar 10 to 25 bar = 40 bar 22 to 42 bar = 48 bar Pressure Connection Style 5 (7/16-20 UNF male for 1/4 in. flared tubing connection) Style 47 (7/16-20 UNF female including valve depressor) Style 28 (with 100 mm tube, 6 mm ODM) Control Action Direct Maximum Output Voltage 95% of Supply Voltage Maximum Current 4 A RMS (at maximum voltage output) Operating Ambient Temperature -40 to 55 C Minimum Current 200 ma Residual Current Motor 25 ma Power Factor (cosϕ) Motor 0.6 Main Supply Voltage 230 VAC + 8% / -15% Main Supply Frequency 50/60 Hz Cut-off Point 30% of Supply Voltage Proportional Band (Range) at 50 Hz* *Approximately 15% less at 60 Hz 5 to 15 bar = 3.0 ± 0.7 bar 10 to 25 bar = 4.5 ± 1 bar 22 to 42 bar = 5.5 ± 1.5 bar Storage Ambient Humidity Storage Ambient Temperature 10 to 98% Relative Humidity (RH) -40 to 85 C Enclosure IP65 Material Top/Bottom Polycarbonate (glass filled) Heat Sink Aluminium Pressure Connection Brass Bellows Phosphor Bronze Shipping Weight 0.3 kg (Individual Pack) Wiring Connections Screw Terminals 1-1/2 mm 2 maximum Quick Connector Plug PG9 (6 to 7 mm cable) Compliance CE Mark Johnson Controls, Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC. RoHS Directive 2002/95/EC; WEEE Directive 2002/96/EC. The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office or representative. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. Johnson Controls International, Inc. Headquarters: European Headquarters: European Factories: Branch Offices: This document is subject to change Milwaukee, WI, USA Westendhof 8, 45143 Essen, Germany Lomagna (Italy), Leeuwarden (The Netherlands) and Essen (Germany) Principal European Cities. Printed in Europe P215PR/RM Series Pressure Controllers 5