Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications



Similar documents
Tel.X Ni-Cd battery. The compact solution for stationary applications

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Sunica.plus Ni-Cd batteries. The robust daily cycling solution for off-grid solar PV systems

Saft stationary batteries. A wide offer of reliable, long-life solutions

Saft railway batteries. Solutions for a world in motion

Optimising the daily operation of industrial trucks

Evolion Li-ion battery. Saft s proven ultra-compact solution for telecom applications

Intensium Max. A range of ready-to-install containerised energy storage for renewable energies and grid management

Saft Li-ion battery systems for hybrid and electric vehicles. Increasing energy efficiency and meeting environmental challenges

How To Make A Train Power Battery System For The Railways

Energy Storage Systems. New solutions for a new energy environment

ULM Ultra Low Maintenance batteries for aircraft. Because you have a choice.

NP Series VALVE REGULATED LEAD-ACID BATTERIES

Thyristor-controlled power supplies and battery chargers

SPH Ni-Cd battery Instant power

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

EssPro Energy Storage Grid Substation The power to control energy

Saft Reliable energy for the internet of things. A wide range of energy solutions for sensing devices

Height w/o Terminals (in)

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

Industrial Batteries System solutions for railways.

SELECTION GUIDE FIFTH EDITION

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

Height w/o Terminals (in)

Carefree Sealed Lead Acid (SLA) MSDS

Maintenance-free sealed lead accumulators. HAGEN drysafe

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Remote Monitoring and REC 501 Control Unit Product Guide

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

stored energy solutions for a demanding world

Battery Model: 25 Part Number: Nominal Voltage: 12 volts NSN: Number applied for, product currently available

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

875 Dearborn Drive Columbus, Ohio Tel: (614) Fax: (614)

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Krav til sikkerhed for sekundære batterier og installationer af batterier Del 2: Stationære batterier

Phase Modular Finally the benefits of Modular ups are for all

Fire Protection of Data Centres

Industrial Batteries Network Power Sonnenschein Solar Safe storage capacity for renewable energy. Specifications

EGSTON Standard E2xFxWx 12W

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Small Traction powerbloc powerbloc dry Hawker XFC TM

Industrial Batteries North America

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

IT S TIME TO EXPECT MORE FROM AN ENERGY STORAGE SOLUTION

Product Environmental Profile Step Down Transformers

Using battery test equipment with asset management software. Megger is a registered trademark

ISO/VDMA Actuators. Engineering GREAT Solutions

OPzS Vented Lead-Acid STANDBY POWER BATTERIES

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

Mobile Data Power Model: MDP-25

GTEC transfer switch open transition

Dlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION

Recycling Material Identification Guide

RiMatrix S Make easy.

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Engineering & Support Services

The Future of Battery Technologies Part I

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

EXCERPT - THE DATA CENTER BATTERY DILEMMA

Primary lithium battery LST 14250

Heat Treatment Process

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

Which switchboards equip your building facilities for the future?

2. Add the following definitions to 3.3 General Definitions and renumber 3.3 as required:

LITHIUM-ION ENERGY MODULES HEM & HPM SERIES

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

MOBILE DC POWER SYSTEMS FOR SUBSTATION APPLICATIONS

Ultrasonic Load Monitoring

The kva RAnge

DRAFT REGULATORY GUIDE DG-1154 (Proposed Revision 2 of Regulatory Guide 1.128, dated October 1978)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

HIGH FREQUENCY RECTIFIERS 24 & 48 VDC

Golf / Utility Vehicles

PHOENIX CONTACT Features

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

For every mission, there is a Vector. VECTOR

MNS is Switchgear System Technical Overview

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

3M Quick Connect System (QCS) 2814

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Our Vector range is growing, so can your profit. Vector Vector 1850

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Medium voltage arc flash eliminator units VAM 3ED,

Explosion proof enclosures

MPR-Systems. Mini Power Racks 1200 W W

Substation Battery & Charger Maintenance

Fuel Cell solutions for maritime and harbour applications Proton Motor Fuel Cell GmbH. Sebastian Dirk Venice, 14th of June

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Screw Compressors 11-22kW

FIREDEX Conventional Fire Panels

Canadian Regulatory Compliance for Stationary Battery Systems North American Update

Engineered Solutions

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

Transcription:

NiCd battery Maintenancefree solution for backup power applications

The ideal choice for total security and availability Saft your trusted battery partner for stationary applications Saft has over 100 years of experience working in partnership with leading industrial customers to deliver wellproven NiCd battery solutions optimized to ensure the total security and availability of stationary applications including power backup, engine starting and bulk energy storage. Our R&D and engineering philosophy is focused on continual improvement of every aspect of our technologies and industrial processes, ensuring that all Saft products and components are designed and manufactured to the very highest quality standards. Saft s comprehensive global service provides expert support throughout every stage of your battery s life from initial concept through volume supply, installation and training to end of life recycling. Uptimax New Generation ensures total reliability and long life even at high temperatures Saft s robust NiCd technology set the benchmark for industrial batteries operating in difficult and demanding conditions. It has established a reputation for performance, reliability and a long, totally predictable, service life with no risk of sudden death failure. Uptimax New Generation builds on this heritage by ensuring a 20year plus service life at + 25 C (+ 77 F). Even at + 35 C (+ 95 F), its lifetime falls by just 20% compared with a 50% reduction for a leadacid battery. Percentage of + 25 C (+ 77 F) lifetime 100 90 80 70 60 50 40 30 20 10 0 25 77 Effect of temperature on lifetime 30 86 35 40 45 95 104 113 Temperature Nickelcadmium Leadacid 50 122 55 C 131 F 2 Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications

Developed for demanding industrial installations Uptimax New Generation: The maintenancefree (1) battery for stationary applications Uptimax New Generation is Saft s latest development in NiCd pocket plate battery technology. It combines maintenancefree (1) operation with total reliability to provide the ideal backup power solution for industrial installations. Together with other key features such as its low pressure flame arresting vent, improved electrical performance and enhanced chargeability, Uptimax New Generation delivers an optimized TCO (Total Cost of Ownership). Uptimax New Generation: Vital support for critical systems Uptimax New Generation batteries are at the heart of power backup systems throughout the oil & gas exploration and production, utility and manufacturing industries. If mains power is lost, Uptimax New Generation delivers the vital power to ensure the continuity of missioncritical loads, facilitate safe shutdown processes, bridge to standby power and safeguard computer data. Typical power backup applications include: UPS, substation switchgear, process control systems, emergency lighting, fire alarms and security systems. (1) The term maintenancefree means that no addition of water is necessary during the life time of the product when operating under Saft s recommended conditions. Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications 3

Delivering enhanced performance and maintenancefree operation Maintenancefree (1) design reduces battery service costs Uptimax New Generation is maintenancefree (1) thanks to a new hightech design concept. Uptimax never needs water to be added throughout its entire service life (under Saft s recommended operating conditions from 20 C ( 4 F) to + 40 C (+ 104 F), at 1.42 V/cell with temperature compensation) Maintenance is reduced to a minimum: only preventive maintenance is necessary The high level of gas recombination is beyond the requirements of IEC 62259 (recombination level higher than 95%), and reduces water consumption and gas emissions Uptimax is equiped with a new low pressure flame arresting vent which operates as a valve regulated vent Enhanced performance optimizes battery life cost Uptimax New Generation offers enhanced performance compared with the original Uptimax. This enables installers to specify a battery optimized for their specific application, saving on initial purchase costs. The new design improves the battery's electrical performance by up to 10%, depending on the required discharge time Commissioning is simple and easy, even after 6 months of storage it can still be carried out using any commercially available charger Good chargeability minimizes battery downtime Uptimax New Generation features fast and simple charging, within a narrow voltage window, for minimal downtime and maximum availability. Single or twolevel charging regimes are possible: Single level charge 1.42 ± 0.01 V/cell Two level charge Float level: 1.42 ± 0.01 V/cell High level: 1.45 ± 0.01 V/cell More than 90% of capacity becomes available, at + 20 C (+ 68 F), after a constant voltage charge at 1.42 V/cell for 15 hours with an available charge current of 0.1 C5A (1) The term maintenancefree means that no addition of water is necessary during the life time of the product when operating under Saft s recommended conditions. 4 Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications

Total reliability ensures the safe operation of your industrial equipment, in even the most demanding operating conditions Uptimax New Generation provides complete peace of mind, whatever the application, whatever the location. Total reliability is based on a unique NiCd electrochemistry/technology combined with the well proven Saft Nife pocket plate design It enables a long service life of over 20 years at + 25 C (+ 77 F) Robust construction eliminates risk of sudden death failure Uptimax delivers long life and outstanding performance in temperatures up to + 40 C (+ 104 F) and tolerates 40 C ( 40 F) to + 70 C (+ 158 F) for short durations Available capacity after constant voltage charge Available charge current 0.1C 5 A or 0.2 C 5 A for L type cell % of the rated capacity % of the rated capacity 100 80 60 40 20 0 0 2 1.42 V per cell at + 20 C (+ 68 F) 0.1C5A 4 6 8 10 12 14 16 18 Charging time (hours) 1.45 V per cell at + 20 C (+ 68 F) 0.1C5A 20 22 24 1.45 V per cell at + 20 C (+ 68 F) 0.2C5A Available capacity after constant voltage charge Available charge current 0.1C 5 A for M type cell 100 80 60 40 20 0 0 2 4 6 8 10 12 14 16 18 Charging time (hours) 20 22 24 1.42 V per cell at + 20 C (+ 68 F) 0.1C5A 1.45 V per cell at + 20 C (+ 68 F) 0.1C5A 1.45 V per cell at + 20 C (+ 68 F) 0.2C5A Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications 5

Modular approach based on flexible block configurations Facilitates ease of handling, installation and operation Uptimax New Generation batteries make transportation, installation and operation fast and easy. Batteries are only delivered filled with electrolyte and in electrically charged condition Storage for up to 2 years in normal conditions is possible and in some circumstances also at higher temperatures Design enables batteries to be assembled in blocks of up to 10 cells connected in series Flexible block configuration makes the battery easy and fast to install Uptimax construction features Low pressure vent Terminal pillars protected by covers in line with EN 502722 / IEC 624852 (safety) with IP2 level Plate group bus bar Plate tab Polypropylene cell container Pocket plate Polypropylene fibrous separators Cells are welded together to form a rugged block up to 10 depending on cell size and type 6 Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications

Flexible configuration based on cell blocks With single pole bolts L (4) L (5) L (6) L (7) L (8) L (9) L (10) UP1 L 1562, UP1 L 95, UP1 L 140280 UP1 M 848, UP1 M 70 UP1 L 1562 UP1 M 848 With double pole bolts L (2) L (3) L (4) L (5) L (6) L (7) UP1 L 325470 UP1 M 245445 UP1 L 75, UP1 L 110 UP1 M 65 With 26 bolts per pole, crosswise mounted on racks L (1) L (1) L (1) L (1) L (1) UP1 L 515560 UP1 L 610840 UP1 M 490640 UP1 L 8901120 UP1 M 690885 UP1 L 12201400 UP1 M 9351030 UP1 L 15001700 UP1 M 11301330 Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications 7

Easy to operate and install A wide choice of capacity and performance Uptimax New Generation cells are available in capacities from 8 1700 Ah in a choice of two ranges: UP1 L energy range, optimized for long discharge periods with a relatively low current UP1 M medium power range, specifically designed for mixed loads with varying current Uptimax New Generation UP1 L L type cell Range of 34 cells 15 1700 Ah For low rate discharges over long periods between 1 and 100 hours Uptimax New Generation UP1 M M type cell Range of 38 cells 8 1330 Ah For varied loads with low and high discharge rates, between 30 minutes and 3 hours Temperature derating factors for L type cell Temperature derating factors for M type cell 1.2 1.1 Derating factor 1.0 0.8 0.6 0.4 Derating factor 1.0 0.9 0.8 0.7 0.6 0.5 0.2 20 4 10 14 0 32 10 20 30 40 50 68 86 104 Temperature 5 hour rate 1 hour rate C F 0.4 20 4 10 14 0 10 20 30 40 32 50 68 86 104 Temperature 5 hour rate 1 hour rate 30 mn rate C F 8 Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications

batteries are designed in full compliance with the highest quality, safety and environmental standards Electrical characteristics: Certified IEC 62259 Secondary cells and batteries containing alkaline or other nonacid electrolytes Nickelcadmium prismatic secondary single cells with partial gas recombination. Uptimax New Generation exceeds gas recombination requirements. Certified IEC 60623 Secondary cells and batteries containing alkaline or other nonacid electrolytes Vented nickelcadmium prismatic rechargeable single cells. Safety: Complies with EN 502722/ IEC 624852 Safety requirements for secondary batteries and battery installations Part 2: Stationary batteries The protective covers for terminals and connectors, the insulated cables are compliant with IP2 level protection against electrical shocks according to safety standard. Quality: ISO 9001 and ISO 14001 Saft world class continuous programme Environment & Recycling: Fully recyclable RoHS Although batteries and accumulators are not within the scope of the RoHS directive, Saft has taken voluntary measures to make sure that the substances forbidden by RoHS are not present in the battery, with the exception of the electrochemical core. REACH The Saft Group has adopted internal procedures to ensure conformity with the European REACH (Registration, Evaluation, Authorisation and Restriction of Chemical Substances) Regulation. Saft offers total end to end application support Saft s stationary battery experts can call upon a comprehensive range of skills and expertise to help our global customer specify the ideal battery solution for their particular application. Our end to end support starts at the design stage, such as advice on battery sizing, and carries customers through installation and commissioning. Saft aftersales cover support, maintenance, diagnostic services as well as end of life recycling. Saft organizes battery training seminars for consultants, engineering and maintenance departments. To ensure that our customers receive the optimum service, wherever they are in the world, Saft is continuing to expand and enhance its network of approved service stations in the Middle East, Asia and North America. Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications 9

Physical properties L range Cell type Capacity Height Width Length per block 4 cells 5 cells 6 cells 7 cells 8 cells 9 cells 10 cells Approx. weight per cell Internal resistance (1) C5 Ah mm in mm in mm in mm in mm in mm in mm in mm in mm in kg lb mohm Cell connection bolt per pole UP1 L 15 15 153 6,0 181 7,1 210 8,3 239 9,4 268 297 11,7 1,10 2,42 12,1 UP1 L 30 30 143 5,62 177 6,96 211 8,30 245 9,65 279 11,0 313 12,3 347 13,7 1,80 3,96 6,03 UP1 L 47 47 191 7,51 237 9,33 283 11,1 329 13,0 375 1 467 18,4 2,50 5,51 3,85 UP1 L 62 62 239 9,40 297 11,6 355 13,9 413 16,3 471 18,5 529 20,8 587 23,1 3,20 7,05 2,92 UP1 L 75 75 329 12,9 409 16,1 490 19,2 571 22,5 4,30 9,47 2,41 2x UP1 L 95 95 156 6,14 192 7,55 228 8,97 4,90 10,8 2,55 M8 UP1 L 110 110 425 16,7 529 20,8 634 24,9 739 29,1 5,70 12,5 1,65 2x UP1 L 140 140 204 8,03 252 9,92 300 11,8 6,70 14,7 1,73 UP1 L 185 185 252 9,92 312 12,2 372 14,6 8,40 18,5 1,31 UP1 L 235 235 304 11,9 377 1 450 1 9,90 21,8 1,03 UP1 L 280 280 437 17,2 11,5 25,3 0,86 Cell type Capacity Length per block Approx. Internal Height Width weight resistance (1) 1 cell 2 cells 3 cells per cell C5 Ah mm in mm in mm in mm in mm in kg lb mohm Cell connection bolt per pole UP1 L 325 325 228 8,97 336 13,2 15,1 33,2 0,74 UP1 L 375 375 252 9,92 372 14,6 16,8 37,0 0,65 UP1 L 420 420 278 10,9 411 16,1 18,3 40,3 0,58 UP1 L 470 470 304 11,9 450 1 19,8 43,6 0,51 UP1 L 515 515 171 6,73 21,4 47,1 0,47 UP1 L 560 560 183 7,20 23,0 50,7 0,43 UP1 L 610 610 207 8,14 26,5 58,4 0,40 UP1 L 650 650 219 8,62 28,2 62,1 0,37 UP1 L 700 700 232 9,13 29,7 65,4 0,35 UP1 L 750 750 243 9,56 31,4 69,2 0,32 H UP1 L 800 800 256 10,0 32,9 72,5 0,3 UP1 L 840 840 268 10,5 34,5 76,0 0,29 UP1 L 890 UP1 L 940 890 940 291 304 11,4 11,9 38,1 39,6 83,9 87,3 0,27 0,26 W L UP1 L 980 980 315 12,4 41,2 90,8 0,25 UP1 L 1030 UP1 L 1120 UP1 L 1220 UP1 L 1300 UP1 L 1400 1030 1120 1220 1300 1400 327 387 412 437 12,8 15,2 16,2 17,2 42,9 46,0 51,3 54,4 57,5 94,5 101,4 113,0 119,9 126,7 0,23 0,22 0,20 0,19 0,17 5x 5x 5x The block length and weight are determined by the number of cells in the block. All tabulated dimensions are maximum values. UP1 L 1500 1500 472 18,5 62,8 138,4 0,16 6x UP1 L 1600 1600 497 19,5 65,9 145,2 0,15 6x UP1 L 1700 1700 69,0 152,1 0,14 6x (1) Rigid connector included 10 Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications

Physical properties M range Cell type Capacity Height Width Length per block 4 cells 5 cells 6 cells 7 cells 8 cells 9 cells 10 cells Approx. weight per cell Internal resistance (1) C5 Ah mm in mm in mm in mm in mm in mm in mm in mm in mm in kg lb mohm Cell connection bolt per pole UP1 M 8 8 153 6,0 181 7,1 210 8,3 239 9,4 268 297 11,7 1,10 2,42 12,5 UP1 M 16 16 4 152 5,96 181 7,12 210 8,27 239 9,41 268 297 11,7 1,50 3,30 6,25 UP1 M 24 24 143 5,62 177 6,94 211 8,30 245 9,65 279 10,9 313 12,3 347 13,6 1,80 3,96 4,17 UP1 M 32 32 191 7,51 237 9,31 283 11,1 329 13,0 375 1 467 18,4 2,50 5,51 3,13 UP1 M 40 40 239 9,40 297 11,6 355 13,9 413 16,3 471 18,5 529 20,8 587 23,1 3,20 7,05 2,50 UP1 M 48 48 239 9,40 297 11,6 355 13,9 413 16,3 471 18,5 529 20,8 587 23,1 3,30 7,27 2,08 UP1 M 65 65 377 1 469 18,4 562 22,1 655 25,8 5,00 11,0 1,54 2x UP1 M 75 75 156 6,14 192 7,55 228 8,97 4,90 10,8 1,52 M8 UP1 M 100 100 186 7,32 230 9,03 273 10,7 6,30 1,14 M8 UP1 M 125 125 228 8,97 282 11,1 336 13,2 7,60 16,7 0,91 UP1 M 150 150 252 9,92 312 12,2 372 14,6 8,40 18,5 0,76 UP1 M 170 170 304 11,9 377 1 450 1 9,90 21,8 0,67 UP1 M 437 17,2 11,5 25,3 0,58 UP1 M 220 220 437 17,2 12,0 26,4 0,52 Cell type Capacity Length per block Approx. Internal Height Width weight resistance (1) 1 cell 2 cells 3 cells per cell C5 Ah mm in mm in mm in mm in mm in kg lb mohm Cell connection bolt per pole UP1 M 245 245 228 8,67 336 17,2 15,2 33,5 0,47 UP1 M 240 9,44 354 13,9 16,0 35,2 0,42 UP1 M 295 295 252 9,92 372 14,6 16,8 37,0 0,39 UP1 M 320 320 278 10,9 411 16,1 18,3 40,3 0,36 UP1 M 345 345 304 11,9 450 1 19,8 43,6 0,33 UP1 M 370 370 328 12,9 486 19,1 21,4 47,1 0,31 UP1 M 395 395 23,0 50,7 0,29 UP1 M 420 420 23,5 51,8 0,27 UP1 M 445 445 24,0 52,9 0,26 UP1 M 490 490 219 8,62 28,2 62,1 0,23 UP1 M 540 540 243 9,56 31,4 69,2 0,21 H UP1 M 590 590 268 10,5 34,5 76,0 0,19 UP1 M 640 640 268 10,5 35,5 78,2 0,18 UP1 M 690 UP1 M 740 690 740 304 327 11,9 12,8 39,6 42,9 87,3 94,5 0,17 0,15 W L UP1 M 785 785 46,0 101,4 0,15 UP1 M 835 UP1 M 885 UP1 M 935 UP1 M 985 UP1 M 1030 835 885 935 985 1030 340 412 437 412 13,3 16,2 17,2 16,2 45,9 48,0 54,4 57,5 56,4 101,1 105,8 119,9 126,7 124,3 0,14 0,13 0,12 0,12 0,11 5x 5x 5x The block length and weight are determined by the number of cells in the block. All tabulated dimensions are maximum values. UP1 M 1130 1130 497 19,5 65,9 145,2 0,10 6x UP1 M 0 0 491 19,3 67,6 149,0 0,09 6x UP1 M 1330 1330 72,0 158,7 0,09 6x (1) Rigid connector included Uptimax New Generation NiCd battery Maintenancefree solution for backup power applications 11

Saft is committed to the highest standards of environmental stewardship As part of its environmental commitment, Saft gives priority to recycled raw materials over virgin raw materials, reduces its plants air and water releases year after year, minimizes water usage, reduces fossil energy consumption and associated CO2 emissions, and ensures that its customers have recycling solutions for their spent batteries. Regarding industrial nickelbased batteries, Saft has had partnerships for many years with collection companies in most EU countries. This collection network receives and dispatches our customers batteries at the end of their lives to fully approved recycling facilities, in compliance with the laws governing trans boundary waste shipments. This collection network meets the requirements of the EU batteries directive. A list of our collection points is available on our web site. In other countries, Saft assists users of its batteries in finding environmentally sound recycling solutions. Please contact your sales representative for further information. Saft 12, rue Sadi Carnot 93170 Bagnolet France Tel. : +33 1 49 93 19 18 Fax : +33 1 49 93 19 64 www.saftbatteries.com Document N 2181720613 Edition: June 2013 Data in this document is subject to change without notice and becomes contractual only after written confirmation. Photo credits: Saft, Fotolia. Rouge 485 D085 Printed on FSC paper by GMK, an Imprim Green member Saft Société par Actions Simplifiée au capital de 31 944 000 RCS Bobigny B 383 703 873