Synchronization. www.andritz.com/neptun



Similar documents
Excitation.

Power Plant Management

Everything you need for protection scheme testing

ABB PSPS Erich Steinmann; Generator control-2013

Permissible ambient temperature Operation Storage, transport

1.44 kw Programmable DC Power Supplies XLN Series

Test & Data Management Software

TDMS Test & Data Management Software

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Multi-Range Programmable DC Power Supplies 9115 Series

Industrial IT for Substation Automation & Protection

Pow-R-Con Multi Function Control

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Physical Specifications (Custom design available.)

Turbo generators Best quality for thermal power plants

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

High Power Programmable DC Power Supplies PVS Series

Multi-Range Programmable DC Power Supplies 9115 Series

Protection and Substation Automation. Training Programmes

Integrated Power Systems for Data Centers

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Products and solutions for pumping, irrigation and piping

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Latest Power Plant Control System

Safety technique. Emergency stop module BO 5988 safemaster

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

HIGH FREQUENCY TRANSFORMER WITH TRANSFORMER SWITCHOVER

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

NEC Class 2 Power Circuits and Power Supplies

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Disturbance Recoder SPCR 8C27. Product Guide

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Substation Automation Systems. Nicholas Honeth

Basics of Electricity

PowerCommand 3201 digital generator set control

INTRODUCTION TO SYNCHRONIZING AUTOMATIC SYNCHRONIZING CONSIDERATIONS AND APPLICATIONS

Table of Contents. TransformerIQ FAQs 1

The Universal DAQ Device. Connect and measure immediately!

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.

EVAL-UFDC-1/UFDC-1M-16

water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.

SPPA-T3000 Control System The Benchmark in Controls

Research RF Sputtering Packages

Temperature & Humidity SMS Alert Controller

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

Complete fleet management package for Qualitrol Information Products

Quick Connect. quick - simple - efficient.

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Server Technology, Inc.

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Considerations When Specifying a DC Power Supply

Electronic Control Devices The European Product Catalogue 2007

SICAM PAS - the Key to Success Power Automation compliant with IEC and your existing system

SolarMax P series The power package for residential solar plants

Measuring Electric Phenomena: the Ammeter and Voltmeter

Updating to Test Universe 3.0. What s new?

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Thyristor-controlled power supplies and battery chargers

Automation Unit TM 1703 ACP Flexible automation and telecontrol

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

T Substation Maintenance and Commissioning Test Equipment

Smart DeviceNet Remote I/O Terminals

VOLTAGE REGULATOR AND PARALLEL OPERATION

30 ms High Speed Transfer System (HSTS) Product Description

Safety Requirements Specification Guideline

415V DISTRIBUTION FOR GREEN DATA CENTERS

Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Polyphase kwh Electricity Meter

Lab E1: Introduction to Circuits

FREJA Win Software for FREJA relay testing system

WIND Power Technology: IMD Integrated Motor Drive

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

Electronic Control Devices The European Product Catalogue 2007

HDO700 P FIBRE OPTIC TRANSMITTER

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

SNMP Web Management. User s Manual For SNMP Web Card/Box

DME4 V1.23 ( ) V1.30 ( ) V1.31 ( ) V1.32 ( ) V1.33 ( ) V1.34 ( ) V1.35 ( ) V2.00 ( ) V2.

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

Basic RTD Measurements. Basics of Resistance Temperature Detectors

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Transcription:

Synchronization www.andritz.com/neptun

02 NEPTUN Synchronization Synchronization 6 x 140 MVA, Birecik, Turkey Synchronizing with success Paralleling of generators to power or one power to ather is a particularly tricky undertaking. At one time, it took a steady hand and full concentration, and this then set the pulse soaring. Nowadays, you can relax and perform this operation automatically using state-of-the-art, technically mature techlogy. Watch calmly as the needles move over your screen, all to the barely discernible sound of synchronization coming from the machine room. All data are logged, allowing you to analyze even the most complicated sequences afterwards in the office. Safety Everything must run perfectly during synchronization. What would you have done previously at zero beat? Were you able to measure the breaker closing time at each periodic inspection? These demands can only be met with reliable, redundant, and rigorously tested techlogy. Our synchronization equipment combines your stringent reliability demands with our experience of over 40 years in this sector. Convenience What are your visions? Easy-to-learn screen visualizations, measurement of CB closing time, plotting of curves, LAN capability with Ethernet log to the other techlogical, operator control via PC/laptop as well as at the equipment itself? Do you want to simply forget about hex tables, operating manuals, painstaking calibrating, and testing? That s the reason why we ve made it all as easy for you as possible. 2 x 84 MVA, Chimay, Peru 5 x 16.7 MVA, 5 de Noviembre, El Salvador

03 NEPTUN Synchronization Strategic products SYN 3000 SYN 3000 features 5 synchronizing modes: generator to grid or supply line synchrous or asynchrous grids or supply lines synchrous or asynchrous or lines with dead bus or line synchro-check for manual connections synchro-check for high-speed busbar transfer As a special function, the circuit breaker (CB) closing time can be measured and stored as a parameter. The basic design contains numerous internal safety functions (double voltage measuring circuits, fail-safe connections for the CB command outputs). To meet the highest of standards, a 2-channel unit can be used. All operating modes, commands and constraints are shown by means of LEDs and a 4-line LC display. LAN communication is based on IEC 60870-5-104 (in preparation). SYN-WIN With the easy-to-use SYN-WIN software, synchronization processes are displayed online on a computer screen. The synchronizing process can be tracked on analog measuring instruments (double voltmeter, double frequency meter, and synchroscope) overlaid on screen. The entire synchronizing process is logged automatically and can be displayed afterwards graphically for analysis and optimization purposes. This software allows the parameters of the SYN 3000 to be entered, modified and saved with password protection. SICAM 1703 ACP If the Al 6303 automation module from the SICAM 1703 ACP product line is used, the synchronization process can be integrated directly into the automation and control. With the direct transformer signal interface, there is need for an additional interface level. As an integrated component, this synchronization tool has all the properties of the SICAM 1703 ACP product line for project planning and visualization in addition to its own specific features. Product range

04 NEPTUN Synchronization The comprehensive solution SYN 3000 operating modes Synchronizing a generator to a power, supply line or busbars Synchronizing two asynchrous Paralleling of two asynchrous Synchronism check and CB close interlock Monitoring of high-speed busbar transfer energized energized energized Speed control Voltage control CB close command Synchronization time monitoring Frequency comparison Voltage comparison Phase angle check manual manual continuous*) Technical data SYN 3000 Voltage measuring Nominal voltage 100 VAC Voltage measuring range 0-150 VAC Nominal frequency 16.7, 50, 60 Hz, depending on completion Load impedance 1 VA Measuring accuracy Voltage measuring 1 V Frequency measuring 0,005 Hz Setting ranges Selector inputs 2 oder 10, depending on type Difference frequency 0,01-0,25 Hz Supply Voltage Optional Power input Temperature range 90-260 VAC and DC 20-56 VDC 8 W 0-50 C Voltage difference 1-30 VAC Permitted phase angle 0-15/45 deg. Residual voltage for power 0-20 VAC SYN 3000 in use

05 NEPTUN Synchronization Your benefit Optimal use: by meeting high safety standards through ergomic operations with password protection with different equipment models by supporting different configurations Reduced costs: with easy integration into existing plants through highly reliable synchronization based on intelligent algorithm with software support for rapid start-up Increased earnings: through faster synchronization with longer life cycle thanks to equipment-friendly configuration NEPTUN the comprehensive solution for secondary can offer additional table advantages in step-bystep expansion of your plant. This gives you integrated advantages in addition to the current benefits of your synchronization if additional components are used (for example excitation, protection, automation and control). Efficient communication standard (IEC 60870-5-104) Comprehensive concepts for remote functions Central engineering toolkit Simplified plant configuration Less engineering and documentation required Minimum of additional infrastructure for signal communication Minimum of spare parts required Liquidation of previously tied capital Fewer maintenance and service assignments on site

www.andritz.com/neptun ANDRITZ HYDRO GmbH Penzinger Strasse 76 1141 Vienna, P.O.B. 5, Austria Phone: +43 (1) 89100 Fax: +43 (1) 8946046 e-mail: contact-hydro@andritz.com MX6-001-1.71 HP.NEP_SYN 01.e.04.10