Proximity Transmitters and Seismic Vibration Transmitters



Similar documents
Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

and Accelerometers

9000 Series Accelerometers Specifications

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Velomitor Piezo-velocity Sensor

Electronic, Digital and Mechanical Vibration Switches

Portable and Online Condition Monitoring System

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

VIBRATION SWITCHES SOLID STATE

Low Frequency Velocity Sensor

3500/40M Proximitor* Monitor

IMVIB. Online vibration monitoring for Ariel compressors

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Dynamic Pressure Charge Amplifier

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

SEISMIC VELOCITY TRANSDUCER T1-40

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

2100 Eddy Current Probe Systems Specifications

1701/22 FieldMonitor Management Interface Module

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

3500/25 Enhanced Keyphasor*Module

SKF Machine Condition Transmitters (MCT) Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

Inductive sensor NI10-M18-Y1X-H1141

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Contents. Document information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Differential Charge Amplifier

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Power Supplies 3. SDN-P DIN Rail Series

3300 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

1900/65A General Purpose Equipment Monitor

3500/93 System Display

Differential-Hall-Effect based Sensors Series A5S Overview

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

1900/65A General Purpose Equipment Monitor

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

3DLevelScanner II TECHNICAL DATA SHEET

Duct Humidity Transmitter

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

DS 600. A contact free flux gate based current measurement sensor 600A rms

Description. Dimensions. Features. precision works better

Vibration Sensors. SKF Condition Monitoring

Description. Specifications and Ordering Information 3300 Proximity Transducer System Patents: 5,016,343; 5,126,664; 5,351,388; and 5,685,884

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Instruction Manual. T3111 T3111L T3111P T3111Ex

Series 6000 Torque measured metal bellow coupling

Application Note TMA Series

Regards from the Team at Rheology Solutions.

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Reaction Torque Sensor

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

TEIP11 I/P signal converter for standard signals. Measurement made easy

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Givare NC-SRS 280 och 880

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Rosemount 333 HART Tri-Loop

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring

Differential-Hall-Effect based Sensors Series A5S

Product Overview 9100D

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

3500/62 Process Variable Monitor

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

2002 IS Catalog. Page

TX2123 RS485 TO ETHERNET ADAPTOR

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Voltech DC1000. Precision DC Bias Current Source

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Fluxi 2000/TZ Turbine Gas Meter

3-Component Measuring System

Asset Condition Monitoring Solutions

Open channel & partially filled pipe Ultrasonic flow meters

How To Make An Ultrasonic Sensor

PART 1 - INTRODUCTION...

40.3. Control Relays and Timers

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Analog signal converters CC-E I/I Current / current isolators

Magnetic proximity switches

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

with Electronic Assistant

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Rosemount 333 HART Tri-Loop

Technical Data Sheet. 3DLevelScanner

3500/22M Transient Data Interface

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

COMBIMASS. Technical Data COMBIMASS eco-bio +

Transcription:

Proximity Transmitters and Seismic Vibration Transmitters TR1101 Seismic Vibration Transmitter The TR1101 is a cost-effective solution for monitoring case vibration on balance of plant machines. The TR1101 conditions the signal from an accelerometer or velocity transducer and provides a 4-20mA output in acceleration, velocity or displacement. Features Measures machinery case vibration 4-20mA output in acceleration, velocity or displacement Buffered output up to 300 meters (1,000 feet) Compatible with other manufacturers sensors (accelerometer or velocity sensor) Aluminum casted (copper free) case with epoxy potting for better environmental protection and reliability Compact size DIN Rail Mount Specifications Electrical Power Supply: 22-30VDC, 100mA (Non isolated) Frequency Response (±3dB): Acceleration: 2.0-10 KHz Velocity: 2-10 KHz (velocity sensor) Velocity: 10-5 KHz (accelerometer) Displacement: 10-3 KHz (velocity sensor) Acceleration (low frequency): 1.0-100Hz Velocity (low frequency): 1.0-100Hz (TM079VD) Displacement (low frequency): 1.0-100Hz (TM079VD) Sensor Interface: Sensitivity: 100mV/g nominal for accelerometer or 4.0mV/mm/sec (100mV/in/sec) nominal for velocity sensor 40mV/mm/sec (1000mV/in/sec) nominal for velocity TM079VD or 4mV/um (100mV/mil) nominal for displacement TM079VD Current Source: Nominal 4mA@24VDC Connectors: GAP/Buf: gap and buffered output SIG: sensor signal COM: signal com 4-20mA: 4-20mA output PREDICTECH Plate Mount 2 ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com

Proximity Transmitters and Seismic Vibration Transmitters Electrical Specifications Continued Buffered Output: Original vibration, un-filtered Impedance: 100Ω Maximum cable distance: 300m (1,000ft) Sensitivity: same as the sensor Overall Vibration: 4-20mA, source Driving load resistance up to 750Ω System Self-test: System OK: output 4-20mA System Not OK: output < 3.0mA Physical Height: 75mm (2.95 ) Weight: 1.0kg (2.0 lbs) Environmental Temperature: Operation: -40 o C to +70 o C Storage: -40 o C to +100 o C Humidity: 90% non-condensing Order Information *Factory Default TR1101-AXX-EXX-GXX AXX: Full Scale A00*: 0-200um pk-pk A01: 0-500um pk-pk A02: 0-100um pk-pk A03: 0-10mil pk-pk A04: 0-25mil pk-pk A05: 0-5.0mil pk-pk A06: 0-50mm/s pk A07: 0-100mm/s pk A08: 0-20mm/s pk A09: 0-2.0ips pk A10: 0-4.0ips pk A11: 0-1.0ips pk AXX: Full Scale Continued A12: 0-5.0g pk A13: 0-10g pk A14: 0-5.0g pk (low frequency) A15: 0-10g pk (low frequency) A16: 0-50mm/s pk (low frequency, E01, E04) A17: 0-100mm/s pk (low frequency, E01, E04) A18: 0-500um pk-pk (low frequency, E04) A19: 0-200um pk-pk (low frequency, E04) A20: 0-2.0ips pk (low frequency, E04) A21: 0-4.0ips pk (low frequency, E01, E04) A22: 0-20mil pk-pk (low frequency, E04) A23: 0-10mil pk-pk (low frequency, E04) A24: 0-2.0ips (50 mm/s) rms A25: 0-1.0ips (25 mm/s) rms A26: 0-0.8ips (20 mm/s) rms A27: 0-0.5ips (12.5 mm/s) rms EXX: Sensor Type (not included) E00*: Accelerometer TM0782A, TM0783A, TM0784A, TM0785A, TM0786A or any current mode accelerometer with 100mV/g E01: Velocity sensor TM0793V, TM0796V or any current mode velocity sensor with 4mV/mm/sec E02: 330500, 330525 velocity sensor E03: 330750 velocity sensor E04: TM079VD low frequency sensor GXX: Mount G00*: DIN rail mount G01: Plate mount TR1101 Accessories The TR1101 requires an external accelerometer or velocity sensor to work as a system. TM0782A, TM0783A, TM0784A, TM0785A, TM0786A: Accelerometer TM0793V, TM0796V: Velocity sensor TM079VD: Low frequency velocity and displacement sensor TM900: Power converter TM0200: 3-1/2 digit display unit ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 3

Proximity Transmitters and Seismic Vibration Transmitters Field-Wiring Diagram Accelerometer PLC/DCS Power From PLC/DCS or TM900 SIG COM 4-20mA POWER BUF Accelerometer 3+ TM0401 1+ 4- (MTL787SP+) 2- Barrier PLC/DCS SIG COM 4-20mA POWER BUF Power From PLC/DCS or TM900 Note: Other barriers available: TM0402: (STAHL 9001/51-280-091-141) TM0407: (STAHL 9160/13-11-11) 4 ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com

Proximity Transducers, Seismic Sensors and Accessories Accelerometer TM0782A General Purpose, Industrial Piezoelectric Accelerometers The TM0782A-K accelerometer kit consists of one accelerometer and one 5 meter cable. This accelerometer kit directly interfaces with ProvibTech s signal conditioners: distributed transmitter monitors (DTM), transmitters (TR), dual monitors (DM) and PT580 vibration switches to measure case vibration in acceleration or velocity. Specifications Electrical Sensitivity: 100mV/g, @ 25 o C, ±10% Frequency Response: 0.5-10,000Hz (±3dB) Acceleration Range: 50g Isolation: Fully isolated Electrical Noise: 0.0007g Power Requirement: 2-10mA constant current 18-30VDC Bias Voltage: 10-14VDC 2-pin connector 50(1.97") 1/4-28" 1/4-28" M6 or 1/4-28" 25(0.98") Resonance Frequency: 30 khz Maximum Transmission Distance: 300 meters (1,000 feet) Environmental and Physical Temperature Range: -50 o C to +120 o C Environmental Protection: IP67 Weight: 90 grams Case Material: Stainless Steel Mounting: 1/4-28UNF tapped hole Installation Torque: 29N x M Hazardous Area Approval: ATEX: II 1 G, Ex ia IIC T4 CSA: Class l, Div. 1, Groups A, B, C and D PCEC, Ex ia IIC T4 Connection A: Power (red) B: COM (white) Shield 16 ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com

Proximity Transducers, Seismic Sensors and Accessories Order Information TM0782A-M Accelerometer with mounting screw 1/4-28 to M6 1 TM0782A-E Accelerometer with mounting screw 1/4-28 to 1/4-28 TM0782A-M-S Accelerometer with mounting screw 1/4-28 to M6 1 Hazardous area approval TM0782A-E-S Accelerometer with mounting screw 1/4-28 to 1/4-28 Hazardous area approval TM0782A-K-M Accelerometer kit includes: TM0782A accelerometer Mounting screw (1/4-28 to M6 1) TM0702-05 TM0782A-K-E Accelerometer kit includes: TM0782A accelerometer Mounting screw (1/4-28 to 1/4-28 ) TM0702-05. Accessories: (Standard cable length is 5 meters. XX = 05) TM0702-XX: Aluminum MIL connector with XX meters cable, 6.35mm diameter. < 120 o C (250 o F) TM0703-XX: Seal tight boot connector with XX meters cable, 6.35mm diameter. < 120 o C (250 o F) TM0704-XX: Stainless steel MIL connector with armored XX meters cable, 4.83mm diameter. < 150 o C (300 o F) TM0705-XX: Cornered MIL connector with XX meters cable, 6.35mm diameter. < 120 o C (250 o F) TM0710: Mounting screw 1/4-28 - M6 1 TM0711: Mounting screw 1/4-28 - 1/4-28 TM0712: Mounting screw 1/4-28 - M8 TM0713: Mounting screw 1/4-28 - M10 ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 17