Colorful Iron Complexes



Similar documents
Tin Man Electrolysis

Target Mole Lab. Mole Relationships and the Balanced Equation. For each student group Hydrochloric acid solution, HCl, 3 M, 30 ml

Dry Ice Color Show Dry Ice Demonstrations

Lab #13: Qualitative Analysis of Cations and Anions

Reaction in a Bag. Scientific Method Demonstrations

Petri Dish Electrolysis Electrolysis Reactions

Properties of Acids and Bases

Wet Dry Ice Lab Phase Changes and Phase Diagrams

Prussian blue and cyanotype printing

Stoichiometry. Can You Make 2.00 Grams of a Compound?

Food Dye Chromatography Student Laboratory Kit

The Determination of an Equilibrium Constant

To determine the mass of iron in one adult dose of either a ferrous sulfate or. ferrous gluconate iron supplement using a colorimetric technique.

Experiment #8 properties of Alcohols and Phenols

Teacher Demo: Turning Water into Wine into Milk into Beer

1. Qualitative Analysis of Chromium, Iron, and Copper

DYES AND DYEING 2003 by David A. Katz. All rights reserved. Permission for classroom use provided original copyright is included.

80. Testing salts for anions and cations

Micro Mole Rockets Hydrogen and Oxygen Mole Ratio As adapted from Flinn ChemTopic- Labs - Molar Relationships & Stoichiometry

Chemistry 111 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium

Teacher Demo: Photosynthesis and Respiration: Complementary Processes

JUNIOR COLLEGE CHEMISTRY DEPARTMENT EXPERIMENT 21 SECOND YEAR PRACTICAL. Name: Group: Date: THE CHEMISTRY OF COPPER AND IRON

hij Teacher Resource Bank GCE Chemistry PSA10: A2 Inorganic Chemistry Carry out a redox titration

Lab #11: Determination of a Chemical Equilibrium Constant

Chapter 16: Tests for ions and gases

Reaction Stoichiometry and the Formation of a Metal Ion Complex

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET TOILET BOWL SANITIZER

Acid Base Titrations

The Determination of an Equilibrium Constant

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

The Empirical Formula of a Compound

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

Whoosh Bottle Safe Laboratory Practices

Experiment 8 - Double Displacement Reactions

Ingredient CAS Number Weight % ACGIH TLV PEL STEL Phosphoric Acid mg/m3 1 mg/m3 3 mg/m3

HOW TO MAKE STANDARD SOLUTIONS FOR CHEMISTRY

Sodium Aluminum Tetrafluoride

The Great Peanut Problem

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

EXPERIMENT 12: Empirical Formula of a Compound

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

Paper Chromatography: Separation and Identification of Five Metal Cations

Biogas. Biology Teams of 2 or 3. Grade LEARNING OUTCOMES DESCRIPTION MATERIALS READINESS ACTIVITIES. Science

SAFETY DATA SHEET West Skyhawk Drive West Jordan, UT U.S.A. Phone

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Properties of Alcohols and Phenols Experiment #3

Lewis Dot Structures of Atoms and Ions

Santa Monica College Chemistry 11

Evaluation copy. Case File 9. A Killer Cup of Coffee? GlobalTech manager dies

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

Lesson 4. Temperature change

Kinetics of Crystal Violet Fading AP* Chemistry Big Idea 4, Investigation 11 An Advanced Inquiry Lab

Upon completion of this lab, the student will be able to:

Building Electrochemical Cells

GlobalTech manager dies

Designing An Experiment Using Baking Soda and Vinegar

MATERIAL SAFETY DATA SHEET

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

SAFETY DATA SHEET FERRIC CHLORIDE SOLUTION 15%

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

TiO 2. : Manufacture of Titanium Dioxide. Registered charity number

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET In accordance with CE Regulation n 1907/2006. Annex II.

Unit 2: Quantities in Chemistry

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

CONTROL: For staining fungus; use a known positive such as those used for the GMS. Use skin, aorta or normal liver for positive PAS staining.

Juice Titration. Background. Acid/Base Titration

One problem often faced in qualitative analysis is to test for one ion in a

TRICHLOROACETIC ACID SOLUTION Department of Pharmacy Duke University Medical Center Box 3089 Durham, NC

Electron Configurations, Isoelectronic Elements, & Ionization Reactions. Chemistry 11

Chemistry 2351: Inorganic Chemistry I Laboratory Manual

Solubility Curve of Sugar in Water

Austin Peay State University Department of Chemistry CHEM 1021 TESTING FOR ORGANIC FUNCTIONAL GROUPS

Section 1 - Chemical Product and Company Identification

Summer Holidays Questions

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

Material Safety Data Sheet

WHAT S NEW, CO? Thanks for the opportunity to work with your students. Our goal is to teach developmentally TEACHER S GUIDE

MATERIAL SAFETY DATA SHEET

Saturated NaCl solution rubber tubing (2) Glass adaptor (2) thermometer adaptor heating mantle

Household Acids and Bases

Safety data sheet for product

Material Safety Data Sheet

Honors Chemistry: Unit 6 Test Stoichiometry PRACTICE TEST ANSWER KEY Page 1. A chemical equation. (C-4.4)

MATERIAL SAFETY DATA SHEET Complies with ANSI Z400.1 Format SECTION 1: PRODUCT IDENTIFICATION

Number of moles of solute = Concentration (mol. L ) x Volume of solution (litres) or n = C x V

IB Chemistry. DP Chemistry Review

EXPERIMENT 8: Activity Series (Single Displacement Reactions)

Magnesium Carbonate, Lite, Powder USP

Sugar or Salt? Ionic and Covalent Bonds

Emergency Phone Numbers: P.O. Box 1950 CHEMTREC: 800/ Brewster, New York POISON CENTER: 800/ /

Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions

EXPERIMENT FIVE. Preparation of Cyclohexene from Cyclohexanol: an Elimination Reaction DISCUSSION

The Electrical Control of Chemical Reactions E3-1

This compound, which contains two carbon atoms with a C-OH structure on one end of the molecule is ethanol, commonly called ethyl alcohol.

MATERIAL SAFETY DATA SHEET

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

Acids, Bases, and ph

Transcription:

elearning 2009 Introduction Colorful Iron Complexes Transition Metal Complex Ions Publication No. 91857 Easily distinguish between solutions of iron(ii) and iron(iii) ions by performing re-dox reactions between iron s two oxidation states. Simply add various complex ions to solutions of iron(ii) or iron(iii) observe formation of the beautifullycolored Prussian blue precipitate or of the deep blood-red complex, the confirming test for iron(iii). Concepts Complex ions Oxidation numbers Oxidation reduction Transition metals Materials solution, 0.02 M, H 2 O, 0 ml solution, 0.02 M, 7H 2 O, 0 ml Colorful Iron Complexes Worksheet Graduated cylinder, 25-mL ferricyanide solution, 0.1 M, K 3, 10 drops Stoppers to fit tubes, ferrocyanide solution, 0.1 M, K 4 3H 2 O, 10 drops Test tubes, 25 150 mm, thiocyanate solution, 0.1 M, KSCN, 10 drops Test tube rack Water, distilled or deionized, 120 ml Safety Precautions This activity requires the use of hazardous components and/or has the potential for hazardous reactions. ferricyanide, potassium ferrocyanide, and potassium thiocyanate are dangerous if heated or in contact with concentrated acids since toxic hydrogen cyanide gas may be liberated. thiocyanate is moderately toxic by ingestion. ferricyanide, potassium ferrocyanide, and ferrous sulfate are slightly toxic by ingestion. is corrosive to skin, eyes, and mucous membranes. may be a skin and tissue irritant. Avoid body contact with all chemicals. Wear chemical splash goggles, chemical-resistant gloves, and a chemical-resistant apron. Please review current Material Safety Data Sheets for additional safety, handling, and disposal information. Wash hands thoroughly with soap and water before leaving the laboratory. Pre-Demonstration Activity 1. Copy enough worksheets for the class using the provided Colorful Iron Complexes Worksheet master. 2. Before performing the demonstration, write the chemical formulas for each of the five solutions on the chalkboard. 3. Have students determine the oxidation number of the iron atom in each compound using rules for assigning oxidation numbers in any standard chemistry text. Procedure 1. Place six test tubes in a test tube rack. Label the tubes 1 and then label tubes 1 3 as Fe 2+ and tubes 4 as Fe 3+. 2. Add approximately 20 ml of 0.02 M iron(ii) sulfate solution and 20 ml of distilled or deionized water to test tubes 1 3. Stopper the tubes and invert to mix. Flinn Scientific Teaching Chemistry elearning Video Series 91857 011509

3. Add approximately 20 ml of 0.02 M iron(iii) chloride solution and 20 ml of distilled or deionized water to test tubes 4. Stopper the tubes and invert to mix. Part A. Ferrocyanide ions, Fe(CN) 4 [Iron in the oxidation state] 4. Add 5 drops of 0.1 M potassium ferrocyanide solution to Tube 1. Since both sources of iron are in the state, the notable deep-blue precipitate does not form. Instead a light blue precipitate of potassium iron(ii) hexacyanoferrate(ii), K 2 Fe[ ], forms according to Equation 1. Fe 2+ + 2K + + [ ] 4 K 2 Fe[ ](s) Equation 1 Light blue ppt 5. Add 5 drops of 0.1 M potassium ferrocyanide solution to Tube 4. A deep-blue precipitate will form according to equation 2, due to the presence of both iron(ii) and iron(iii) ions. This resulting deep blue precipitate is iron(iii) hexacyanoferrate(ii), Fe 4 [, or Prussian blue. Have students determine the oxidation number of each iron atom in the complexes in Equations 1 and 2. 4Fe 3+ + 3[ [ Equation 2 Prussian blue Upon standing for 5 10 minutes, the solution in Tube 1 will turn darker blue as the iron(ii) is slowly oxidized to iron(iii) by atmospheric oxygen to form the same Prussian blue precipitate as in equation 2. Part B. Ferricyanide ions, Fe(CN) 3 [Iron in the oxidation state]. Add 5 drops of 0.1 M potassium ferricyanide solution to Tube 2. A deep-blue precipitate will form with the iron(iii) sulfate. In this reaction, the ferricyanide ions, [, oxidize iron(ii) to iron(iii) forming ferrocyanide ions, [ ] 4, according to Equation 3: Fe 2+ + [ Fe 3+ + [ ] 4 Equation 3 The products of equation 3, the iron(iii) ions and ferrocyanide ions, then combine to form iron(iii) hexacyanoferrate(ii) or Prussian blue, according to equation 2 above. 7. Add 5 drops of 0.1 M potassium ferricyanide solution to Tube 5. A brown solution is observed, indicating no reaction since both iron sources are in the oxidation state, as shown below: Fe 3+ + [ No Reaction Part C. Thiocyanate ions, SCN 8. Add 5 drops of 0.1 M potassium thiocyanate solution to Tube 3. Some light red-brown coloring may appear due to slight oxidation of Fe 2+ to Fe 3+, but no visible reaction is observed. Fe 2+ + 3SCN No Reaction 9. Add 5 drops of 0.1 M potassium thiocyanate solution to Tube. A deep-red complex will form with the iron(iii) sample according to Equation 4. This is a positive indicator test for the iron(iii) ion. Fe 3+ + 3SCN Fe(SCN) 3 Equation 4 Blood-red complex Disposal Please consult your current Flinn Scientific Catalog/Reference Manual for general guidelines and specific procedures governing the disposal of laboratory waste. Dispose of the solutions in the test tubes down the drain with excess water according to Flinn Suggested Disposal Method #2b. Flush any excess potassium thiocyanate, iron(ii) sulfate, or iron(iii) chloride solution down the drain according to Flinn Suggested Disposal Method #2b. Dispose of excess ferricyanide and ferrocyanide solution according to Flinn Suggested Disposal Method #14. 2

Tips It is very helpful to write Fe 2+ and Fe 3+ on the appropriate test tubes and to have the students fill in the provided worksheet as the demonstration is performed. Even the most skilled students (and teachers) may find it hard to keep track of which form of iron is in the tube and which is being added. The demo will have the greatest effect if this confusion is removed. Use this demonstration during the oxidation reduction unit when teaching students about oxidation numbers. Have students perform the pre-demonstration activity to assure that they can determine the oxidation number for iron in each compound. After performing the demonstration, you may wish to use the tests to determine if an unknown contains iron(ii) or iron(iii) ions. You can use a few milliliters of either the iron(ii) sulfate solution or the iron(iii) chloride solution as the unknown. Or you can test any iron solution in your chemical stockroom. Enough of the testing reagents are provided for testing unknowns in each class. Discussion Many transition metals exhibit the ability to exist as relatively stable ions in different oxidation states. Iron can be found as the Fe 2+ ion [iron(ii)] in some compounds. Iron is also found as the Fe 3+ ion [iron(iii)] in other compounds. The variable valence states can be explained by looking at the electron configuration of iron, which is [Ar]4s 2 3d. When transition metal atoms form positive ions, the outer s electrons are lost first because the inner d sublevels are lower in energy (more stable) than the outer s sublevels. In the iron(ii) ion, the two 4s electrons have been lost, leaving [Ar]3d. In the iron(iii) ion, the two 4s electrons and one 3d electron have been removed, leaving [Ar]3d 5. The iron(iii) ion is more stable than the iron(ii) ion since its d orbital is half-filled, containing five electrons, while that of iron(ii) is one more than half-filled. Half-filled orbitals (and filled orbitals) have been shown to have greater stability. Therefore, a compound or a solution containing the iron(ii) ion will slowly oxidize to the iron(iii) state on exposure to air due the greater stability of the Fe 3+ ion. In order to distinguish between iron(ii) and iron(iii) ions, potassium ferrocyanide [K 4 3H 2 O] and potassium ferricyanide [K 3 ] complexes are used in this experiment. The cyano group in each complex has a charge of 1 and potassium has a charge of +1. Thus, the complex ferrocyanide, Fe(CN) 4, contains iron in the oxidation state while the complex ferricyanide, Fe(CN) 3, contains iron in the oxidation state. A deep-blue (Prussian blue) precipitate results when either complex ion combines with iron in a different oxidation state from that present in the complex. The deep-blue color of the precipitate is due to the presence of iron in both oxidation states in the cyano complex. This provides a means of identifying either iron ion. Thus, when a solution of iron(ii) is mixed with ferricyanide [iron(iii)], a deep-blue precipitate is formed; likewise, when a solution of iron(iii) is mixed with ferrocyanide [iron(ii)], a deepblue precipitate is formed. The deep-blue precipitate, Prussian blue, has the composition of Fe 4 [. Prussian blue has been used as a pigment in printing inks, paints, cosmetics (eye shadow), artist colors, carbon paper, and typewriter ribbons. The thiocyanate ion, SCN, provides an excellent confirming test for the Fe 3+ ion. The soluble, blood-red Fe(SCN) 3 complex is formed from the Fe 3+ ion, while no complex is formed with the Fe 2+ ion. Connecting to the National Standards This laboratory activity relates to the following National Science Education Standards (199): Unifying Concepts and Processes: Grades K 12 Systems, order, and organization Evidence, models, and explanation Content Standards: Grades 9 12 Content Standard B: Physical Science, structure and properties of matter, chemical reactions 3

Answers to Colorful Iron Complexes Worksheet Test Tube 1 2 3 4 5 References Solution #1 (Name & Formula) Oxidation # of Iron Solution #2 (Name & Formula) ferrocyanide Oxidation # of Iron Observations Reaction Blue ppt Fe 2+ + 2K + + [ ] 4 K 2 Fe[ ] K 4 Deep-blue ppt Fe 2+ + [Fe(CN) ferricyanide Fe 3+ + [ ] 4 (Prussian blue) K 3 Fe(CN) 4Fe 3+ + 3[ [ thiocyanate KSCN ferrocyanide K 4 ferrocyanide K 3 thiocyanate KSCN Lt. red-brown solution Fe 2+ + 3SCN NR Deep-blue ppt (Prussian blue) 4Fe3+ + 3[ [ Deep reddishbrown solution Fe3+ + [ NR Deep-red solution Fe 3+ + 3SCN Fe(SCN) 3 NR = No Reaction Bilash, B.; Gross, G.; Koob, J. A Demo A Day: Another Year of Chemical Demonstrations, Vol 2; Flinn Scientific: Batavia, IL, 1998; pp 244 24. Tzimopoulos, N. D.; Metcalfe, H. C.; Williams, J. E.; Castka, J. F. Modern Chemistry Laboratory Experiments; Holt, Rinehart and Winston: New York, 1990; p 3. Flinn Scientific Teaching Chemistry elearning Video Series A video of the Colorful Iron Complexes activity, presented by Peg Convery, is available in Transition Metal Complex Ions and in Oxidation States, part of the Flinn Scientific Teaching Chemistry elearning Video Series. Materials for Colorful Iron Complexes are available from Flinn Scientific, Inc. Materials required to perform this activity are available in the Colorful Iron Complexes Chemical Demonstration Kit available from Flinn Scientific. Materials may also be purchased separately. Catalog No. Description AP594 Colorful Iron Complexes Chemical Demonstration Kit F009 Iron(III) Chloride Solution, 1.0 M, 100 ml F001 Iron(II) Sulfate, 500 g P015 Ferricyanide Solution, 0.1 M, 500 ml P0220 Ferrocyanide Solution, 0.1 M, 500 ml P0178 Thiocyanate Solution, 0.1 M, 500 ml Consult your Flinn Scientific Catalog/Reference Manual for current prices. 4

Colorful Iron Complexes Worksheet Test Solution #1 Oxidation Solution #2 Oxidation Tube (Name & Formula) # of Iron (Name & Formula) # of Iron Observations Reaction 1 2 3 4 5 2009 Flinn Scientific, Inc. All Rights Reserved. Reproduction permission is granted only to science teachers who have purchased Transition Metal Complex Ions in the Flinn Scientific Teaching Chemistry elearning Video Series. No part of this material may be reproduced or transmitted in any form or by any means, electronic or mechanical, including, but not limited to photocopy, recording, or any information storage and retrieval system, without permission in writing from Flinn Scientific, Inc. 91857