Fire Extinguishers Water Extinguishers



Similar documents
GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

EACH CLASS of fire A, B, C, or D has a different source. Some

PORTABLE FIRE FIRE SOLUTIONS 1. Portable Fire Equipment Solutions COPY ONLY

All You Ever Wanted to Know About Fire Extinguishers...

FIRE EXTINGUISHER TRAINING

Class A - Wood, paper, cloth, trash, plastics Solid combustible materials that are not metals. (Class A fires generally leave an Ash.

Portable Fire Extinguisher Presentation

EXTINGUISHER. The purpose of this module is to sensitize firefighters on the subject of extinguishers.

Fire Extinguishers. A Health and Safety Guideline for Your Workplace. Fire Extinguishing Methods. Introduction. Types of Extinguishers

On-Line Fire Extinguisher Training

Vehicle Fire Suppression Systems COPY ONLY

FIRE SAFETY FOR OFFICE WORKERS

exit routes and fire protection

and Extinguisher Training

FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

HISTOLOGY LABORATORY EMERGENCY PROCEDURES

San josé OWNER S MANUAL

orlando OWNER S MANUAL

INFORMATION BULLETIN Bulletin No Bureau of Fire Prevention Date: June 10, 2005 Revised: March 8, 2007

FIRE SAFETY HANDBOOK

UL 300 Standard. RS 1021 (9/13) 2013 Nationwide Mutual Insurance Company Page 1 of 6 All Rights Reserved

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

HELI-DECKS & HELI-PORTS

Forename: Surname: School / College/ Institution. Course date: / / RDTHSC:

LPG, Flammable Liquids, Toxic and Corrosive Substances

Annual Fire Safety Training Module

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

MATERIAL SAFETY DATA SHEET

Fire Evacuation Procedures Network Building, 97 Tottenham Court Road, London, W1

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

Question: How effective is Tundra Fire Extinguishing Spray vs. a Traditional Fire Extinguisher?

MATERIAL SAFETY DATA SHEET Product Code: 10033

MATERIAL SAFETY DATA SHEET

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

TWO BURNER PROPANE CAMPING STOVE

Natural Gas Emergencies

Greenhouse gas emissions from direct combustion of various fuels (e.g. grain dryer)

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

Swallowed Do not induce vomiting give 250 ml water to drink. Seek immediate medical attention.

WHMIS After GHS: Preparing for Change. Canadian Centre for Occupational Health and Safety

Fire Safety and Extinguishers

WELDING & CUTTING MAIN EQUIPMENT

HEALTH AND SAFETY REDUCING ACCIDENTS IN KITCHENS

Material Safety Data Sheet

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Pressure Vessels (Air Compressors) and LPG Tanks

Fire Protection and Prevention

Compressed Gas Cylinder Program

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Fire & Safety. Fire Safety Training For FHSc Staff and Students in Health Care Facilities

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

MOTOR FUEL DISPENSING SAFETY

- Save lives and reduce material damage

Nonrenewable Natural Gas. Natural Gas Basics. How Was Natural Gas Formed?

CAMPING STOVES. Spirit stove with gas adaptor - simple and well shielded.

Safety Data Sheet. MAPP Gas. Page 2 / 6. According to regulation (EC) 1907/2006. ROTHENBERGER Werkzeuge GmbH Industriestr.

Presented by: Rich Perry Marsh Risk Consulting

Confined Space Entry Procedure Worksheet

MATERIAL SAFETY DATA SHEET

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

LESSON PLAN 1. Fire Science. Key Terms and Concepts. ash chemical reaction combustion Consumer Product Safety Commission endothermic exothermic

Name Of Occupancy Date. Yes No Describe

Cleaning of floor coverings. Vacuum Cleaners Brush-Type Vacuum Cleaners Spray Extractors Single Disc Machines Cleaning Machines - Cleanser

Orange County Fire Rescue Division Fire Loss Management Bureau 109 East Church Street Lower Level Orlando, Florida

UNDERSTANDING CENTRAL HEATING SYSTEMS

CO 2. fire extinguishing systems

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

1. PRODUCT AND COMPANY IDENTIFICATION

What is Dry Ice? Dry Ice Company Safety Rules: DRY ICE: SAFETY DATA SHEET & RISK ASSESSMENT

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

Formal Interpretation NFPA 10. Portable Fire Extinguishers Edition

CeramClean II Aluminum Safe

System Accessories Pricing. Page 0 Effective 7/02

THE WHOLE WORLD OF GAS SAFETY ENGINEERING. MINISPRAYJET Flame spraying gun

Foam Recycling is Viable. A Profitable Industry in the Making

Natural Gas Information Contents

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

BLACK JACK ALL WEATHER ROOF COATING

Material Safety Data Sheet

1.0 Purpose Definitions Hot Work Operations. 5

Ingredient % content Hazard data Cross linked Sodium Polyacrylite CAS No: Non chemical fillers Zeolite 1-10

SHINKOLITE, Mitsubishi Rayon Co., Ltd, June 22, 2015 Page 1/5 SAFETY DATA SHEET

I.CHEM.E. SYMPOSIUM SERIES NO. 97

The Fire Safety Manager at (FAX ) can answer any questions or provide a set of fire code information.

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Dry Chemical Systems TWIN AGENT CAPABILITY

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

Material Safety Data Sheet

One Seven... the future of firefighting

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

FIRE PREVENTION PLAN

Transcription:

Water Extinguishers Water extinguishers are suitable for Class A fires caused by combustion of solid materials such as wood, paper, straw, textiles and coal etc. Water additive extinguishers use an environmentally friendly additive that greatly enhances the performance against Class A fires Typical applications for these extinguishers include commercial offices, public places, restaurants, hotels, schools, industrial units and many others. Robust design Controlled discharge High quality epoxy resin finish (weather resistant) Fully BS-EN3 approved Quality lining Minimum space required Rapid deployment External thread Quality at the right price Model Capacity Type Fire Rating WSP 9/2 9 litre Stored WSP 6/2 6 litre Stored Weight of Exting agent 21A 13.4 kg Water 9 bar 45 secs. 7-8 m -5 o C to +60 o C 605H x 180D 13A 9.2 kg. Water 9 bar 30 secs. 4-6 m -5 o C to +60 o C 549H x 160D WASP 6/2 6 litre Stored WASP 3/2 3 litre Stored 21A 9.2 kg. Water + additive 13A 6.7 kg. Water + additive 9 bar 30 secs 4-6 m -5 o C to +60 o C 549H x 160D 9 bar 30secs. 4-6 m -5 o C to +60 o C 445H x 160D

Foam Extinguishers Foam spray extinguishers, (AFFF-Aqueous Film Forming Foam), are ideal for multi-risk situations where both Class A combustible materials and Class B flammable liquid risk are likely to be found, or where Class B risks represent a direct hazard. Foam spray extinguishers are especially suitable for Class B fires involving flammable liquids such as oils, spirits, fats and certain plastics. The blanketing effect of foam spray gives rapid knock down which smothers the flame and prevents reignition of flammable vapours by sealing the surface of the solution. Available in Slimline design Easy to handle Effective spray application Replaces bulkier 9 litre water extinguishers Higher performance Now available without torque Uses 1% AFFF Reduced service time Reliability Knockdown performance FSP 2/1 2 litre Stored FSP 3/2 3 litre Stored 8A/55B 3.2 kg. 12 bar 6secs 2 m -5 o C to +60 o C 430H x 108D 13A/55B 6.1 kg. 9 bar 18 secs 2-4 m -5 o C to +60 o C 450H x 160D FSP 6/2 6 litre Stored FSP 9/2 9 litre Stored 13A/113B 9.5 kg. 9 bar 30 secs 4-6 m -5 o C to +60 o C 549H x 160D 21A/183B 13.5 kg. 9 bar 45 secs 4-6 m -5 o C to +60 o C 605H x 180D

Carbon Dioxide Extinguishers Carbon Dioxide extinguishers are suitable for fires involving flammable liquids and electrical hazards. The non conductive qualities of carbon dioxide make it an ideal choice for dealing with fires involving electrical equipment and machinery. The carbon dioxide used in these extinguishers is a recovered industrial bi-product, thereby reducing the carbon levels that can contribute to the greenhouse effect. Typical applications can be found in hospitals, supermarkets, hotels and restaurants, paint shops, fast food chains, clothing and fabric industries, industrial units, offices, etc.. Robust design Safe and easy to handle Hose and horn or swivel horn Lightweight aluminium cylinder or lightweight steel Higher performance Excellent fire ratings Powerful extinguisher Reduced service time High reliability High fire fighting performance Ideal for industry Model Capacity Fire Rating Weight of Exting agent CD 2/2 2 kg. 34B 5.0 kg. CO 2 6 secs. -20 o C to +60 o C 502H x 118D CD 2/3 2 kg. 55B 5.0 kg. CO 2 6 secs. -20 o C to +60 o C 502H x 118D CD 5/2 5 kg. 55B 11.4 kg. CO 2 9secs. -20 o C to +60 o C 677H x 152D

Dry Powder Extinguishers Powder Extinguishers are suitable for use on Class A, B and also Class C type fires involving flammable gases such as propane and butane. They are also highly effective for electrical hazards. This multipurpose extinguisher interferes with the combustion process and provides rapid fire knock down. They are ideal for mixed fire risk environments and especially suited for the protection of flammable liquids, storage of liquid gases and heating oils used for industry, garages and workshops, etc.. Squeeze grip operation Controlled discharge Pressure gauge Compact design Ease of use Easy to service and maintain Unique valve system Covers many types of risk Rapid knockdown PSP/GP 1/3 1 kg. Stored PSP/GP 2/3 2 kg. Stored Exting agent (Glutex) 5A/34B 2.1 kg. ABC 13A/70B 3.7 kg. ABC 12 bar 6 secs >4 m -20 o C to +60 o C 340H x 86D 12 bar 6 secs >4 m -20 o C to +60 o C 415H x 110D PSP/GP 4/2 4 kg. Stored PSP/GP 6/2 6 kg. Stored PSP/GP 9/2 9 kg. Stored 21A/113B 6.7 kg. ABC 34A/113B 9.3 kg. ABC 55A/183B 13.1 kg. ABC 12 bar 9. secs >4 m -20 o C to +60 o C 445H x 160D 12 bar 12 secs >6 m -20 o C to +60 o C 549H x 160D 12 bar 15 secs. >6 m -20 o C to +60 o C 605H x 180D

Type F Wet Chemical Extinguisher These extinguishers have been specifically designed for Class F fire risks involving cooling oils. The wet chemical agent rapidly knocks down the flames, cools burning oil and seals the surface to extinguish the fire and prevent re-ignition. Long discharge hose with controlled discharge Effective spray application High performance Minimum space required Rapid deployment Knockdown performance of applied like foam Saves time/money WCSP 6 litre Stored Pressure Approvals:, PED CE 05PED4667 13A/113B 9.5 kg. 9 bar >30 secs. 4-6 m 5 o C to 60 o C 549H x 160D