SHG-AF Series (Spherosyn Absolute) Linear Encoder



Similar documents
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Absolute Rotary Encoder E6CP

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Color Mark Sensor with Red or Green LED E3S-VS

Series 6000 Torque measured metal bellow coupling

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Series 7500 Torque Sensor

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

In-Sight Hardware specifications

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Givare NC-SRS 280 och 880

intelligent solutions

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Description. Dimensions. Features. precision works better

Speed sensor MiniCoder GEL 247

MULTI-BEAM LS10 Light Screen System

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

D.C. Motors. Products and specifications subject to change without notice.

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PLUTO Safety-PLC. Manual Absolute Encoders

ATL Fuel Level Sender Probes

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Original instructions Tina 3A/Aps Adaptor unit

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Electronic Pressure Switch EDS 3000

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

How To Read A Pipe From A Sensor

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Power Supplies 3. SDN-P DIN Rail Series

Speed Control Relays SX2

PROXIMITY CARD READERS C-10, C-20, C60, C70

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Adjustment functions for both span and shift have been incorporated

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Electronic Pressure Switch EDS 300

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Technical Data. back-up time in minutes 100% load % load

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

QR12 (1.22 ) Diameter Optical Encoder

LUT Luminescence scanners: Seeing what no-one else can

Low Frequency Velocity Sensor

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Relative pressure transmitter type 520

Allen-Bradley/Rockwell

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

Talon and Talon SR User Manual

Tina 2A/B Adaptor unit

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

D. PARAMETER SPECIFICATION Measured Variable: Displacement

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

I STAR COMPUTER CO., LTD

PIEZOMETER AIRFLOW MEASURING RING

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Capacitive Prox E2K-X

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

- 1 - Eddy Current. Eddy current distance and displacement transducer

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

connecdim Gateway G1 Ethernet TCP/IP to DALI

How To Use A Flowmeter

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Cable Plug acc. to DIN EN , Form A

Inductive sensor NI10-M18-Y1X-H1141

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Manual for Fire Suppression & Methane Detection System

Turbine Flow Sensor Series VTR

PCS0100en Persy Control Services B.V. Netherlands

Automation Solutions. LÜTZE LCOS empty housing for Industrial Automation

Transcription:

Newall Measurement Systems SHG-AF Series (Spherosyn Absolute) Linear Encoder. Fanuc Serial Protocol

SHG-AF SERIES (SPHEROSYN ABSOLUTE) LINEAR ENCODER WITH FANUC SERIAL INTERFACE (Revision 01.04.05) REQUIREMENTS Fanuc CNC control with SDU1 encoder interface module. Ensure the ground terminal connection on the SDU1 module is connected to the machine ground or equipotential terminal. Ground Wire Connection Note: There is a screw terminal connection on the main PCB of the Encoder interface module that should be connected to Ground. If not then the display may show jitter (instability), particularly when the machine is in E-STOP. (Grounding of the module is not detailed in the Fanuc installation instructions. See Fanuc drawing No: A-65434EN for details). It is recommended that n-pulse suppression is enabled (set to 1) SPECIFICATION Power Requirements 5Vdc +-5% < 350mA Shock (11ms) 100g / 980m/s-2 (IEC 69-2-6) Vibration (55-2000Hz) 30G / 294m/s-2 (IEC 68-2-27) Ingress Protection Level IP67 Operating Temperature Range 0 to 55 deg. C (32 to 131 deg. F) Storage Temperature Range -20 to 70 deg. C (-4 to 158 deg. F) Scale Material 316 Grade Stainless Steel Scale (Tube) OD 15.25mm (0.601 ) Moving Force 20N Standard Cable 15-core Cable with PUR Max Cable Length 20m (65ft) Cable Bend Radius (PUR) Static: 12.7mm (0.5 ) Active: 50.8mm (2 ) Cable Bend Radius with Armor 50.8mm (2 )

CONNECTIONS Function Colour Pin (Honda PCR-E20FA) Fanuc RQ+ Light Green 5 +5VDC Black 9, 18, 20 Fanuc RQ- Light Green + White 6 Fanuc Data+ Brown 1 Fanuc Data- Brown + White 2 0V White 12, 14, 16 PC Orange 12 Connector used is part number: PCR-E20FA by Honda Tsushin Kogyo SIGNAL LED The status of the encoder is shown by the Signal LED. On power up the Signal LED is red to indicate that the absolute position is being acquired, and then after a short time interval changes to green to indicate that valid position data is available. During normal operation the signal LED changes to red if an error is detected. ALARM SIGNAL DESCRIPTIONS The Spherosyn Absolute Encoder can activate three types of alarm signal: Phase Alarm, Count Miss Alarm, and Pulse Miss Alarm. The conditions necessary to activate these alarms are described in the table below. ALARM LINE ALARM ALARM TYPE FANUC ALARM DESCRIPTION NEWALL ALARM DESCRIPTION B7 OHAL Over heat Temperature in the encoder is too high. Not implemented B6 LDAL LED LED is not working. Not implemented B5 BLAL Battery low Battery voltage is low. Not implemented B4 PHAL Phase Miss detection occurs by noise Activated by a or other causes. discrepancy between the accumulated pitch number and the continuously sampled pitch number obtained from the hall sensors during slow traverse speeds. B3 CMAL Count miss Absolute position is abnormal Not implemented by miscounting position. B2 BZAL Battery zero B1 PMAL Pulse miss Battery voltage had been lower than minimum operating voltage. Trouble is detected in the interpolation circuit by noise or other causes. B0 PCAL Logical sum (OR) of B7(overheat) and B1(pulse miss). Not implemented 1. Activated by detection of an invalid pitch count that is sampled on power up. 2. Activated by an error in the accumulated pitch number that is continuously updated. 3. Activated by travelling below the scale zero position. PCAL is activated by the logic sum of all of the other alarms (b1 to b7) NEWALL ALARM FLAGS 02(hex). 04(hex) power up. 01(hex) pitch no. error 01(hex) pitch no. error. 04(hex) power up.

ZERO POINT MARKER The scale is marked with an arrow and a line at the position where the position data is zero. This point is 55mm in from the end of the scale. If the encoder travels between the end of the scale and the zero point (below zero) then the position data remains fixed at zero. Assuming that the RQ and data lines are connected to the Fanuc control, the LED on the front of the encoder changes from green to red and the Count Miss alarm is activated to indicate that the encoder is positioned below zero. The Count Miss alarm can be cleared by issuing an alarm reset when the encoder is positioned at zero or above. Encoder serial number Encoder Zero point INSTALLATION Install the scale and reader head hardware as described in the Spherosyn Absolute (SHG-A_), Distance Coded (SHG-TC), and Digital SP (SHG-TS & SHG-VS) Encoder Hardware Installation Manual (Code LEHM). It is important to ensure that the scale and reader head are rotationally aligned before operation. There is an arrow etched into the tube that needs to be aligned with the notch in the reader head. Once aligned the scale brackets are tightened as detailed in the installation manual. Align arrow with notch Apply power to the reader-head. The Signal LED on the front of the reader-head will go RED and then GREEN as it establishes position and performs its self-diagnostics. Move the reader-head along the full length of travel from the scale (taking care not enter the extreme 50mm at either end of the scale). The reader-head LED should stay GREEN during the full period of movement. If the LED changes to RED then the scale is not correctly aligned. If this occurs loosen the scale and rotate the scale in the brackets by approximately 2-3 degrees. Secure the scale and repeat the process until the signal LED remains GREEN for the full period of travel. Your installation is now complete.

NEWALL MEASUREMENT SYSTEMS Technology Gateway. Cornwall Road. South Wigston Leicester. LE18 4XH. England Tel: (+44) 0116 264 2730. Fax: (+44) 0116 264 2731 E-mail: sales@newall.co.uk NEWALL FRANCE SARL 63 Rue Victor Hugo. F-59200. Tourcoing. France Tel: 03 20 01 03 13. Fax: 03 20 26 13 41 E-mail: sales@newall.co.uk NEWALL ELECTRONICS INC 1778 Dividend Drive. Columbus. Ohio. 43228. USA Tel: (+1) 614 771 0213. Fax: (+1) 614 771 0219 E-mail: sales@newallusa.com Website: www.newall.com Issue Date: January 2005