XV.Quality Assurance in the Blood Bank



Similar documents
JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

CHAPTER 7 QUALITY ASSESSMENT

Blood, Plasma, and Cellular Blood Components INTRODUCTION

DEPARTMENT OF CLINICAL LABORATORY SCIENCES SCHOOL OF HEALTH TECHNOLOGY AND MANAGEMENT THE UNIVERSITY AT STONY BROOK STONY BROOK, NEW YORK

LABORATORY TECH IV POSITION DESCRIPTION

Transfusion Medicine: Checklists and Challenges

Cold Agglutination Titer detecting Cold Reacting Antibodies

A Roadmap for Competency Assessment ASCLS-NJ Spring Seminar April 24, 2014

Document Review: Centers for Medicare and Medical Service (CMS) What Do I Need to Do to Assess Personnel Competency?

Answers to Your Questions About Blood Bank Proficiency, Competency and QC Follow Up to April 28, 2016 Webinar

Cellular Therapy Liaison Meeting 10 September 2009 BECS. M. Allene Carr-Greer, MT(ASCP)SBB Director, Regulatory Affairs AABB

NEW JERSEY STATE SANITARY CODE CHAPTER 8 ( N.J.A.C. 8:8-1 et seq.) COLLECTION, PROCESSING, STORAGE AND DISTRIBUTION OF BLOOD

CHAPTER 13. Quality Control/Quality Assurance

CHAPTER 8 COLLECTION, PROCESSING, STORAGE AND DISTRIBUTION OF BLOOD. Authority. N.J.S.A. 26:1A-7 and 26:2A-7. SUBCHAPTER 1. GENERAL PROVISIONS

LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

EFI ACCREDITATION PROGRAM. INSTRUCTIONS TO APPLICANT - PACKET A and C: APPLICATION FOR ACCREDITATION AND RENEWAL OF ACCREDITATION

Direct Antiglobulin Test (DAT)

University of Colorado Hospital Policy and Procedure Transplant and Implant Tissue Storage and Issuance

Introduction. Laboratory Procedure Manual

Jennifer Collins, RN Quality Liaison Ann & Robert H. Lurie Children's Hospital of Chicago

Table of Contents. September 2012 Page 1 of 1

Response to Public Comments for the 7 th edition of Standards for Cellular Therapy Services

BLOOD BANK ANNUAL STATISTICS (HOSPITALS)

Content Sheet 4-1: Purchasing and Inventory Overview

PACT Web Seminar July 19, 2007

Direct Antiglobulin Test (DAT)

Document and Record Control in a Hospital Clinical Laboratory

5th Edition NetCord-FACT International Standards for Cord Blood Collection, Banking, and Release for Administration. Summary of Changes

Quality Assurance Guidelines for Testing Using Rapid HIV Antibody Tests Waived Under the Clinical Laboratory Improvement Amendments of 1988

Procedure: Quality Assurance Policy Version 5 Quality Assessment Policy Version 3

Prepublication Requirements

PROCEDURES FOR HANDLING OOS RESULTS

Standards for Laboratory Accreditation

NC SBI QUALITY ASSURANCE PROGRAM

ILLINOIS DEPARTMENT OF CENTRAL MANAGEMENT SERVICES CLASS SPECIFICATION CLINICAL LABORATORY TECHNICIAN SERIES

TRANSFUSION MEDICINE

State Water Resources Control Board Environmental Laboratory Accreditation Program

Role of the Medical Director

AUTOLOGOUS BLOOD DONATION

LABORATORY PROCEDURE MANUAL

Northern Ireland Blood Transfusion Service

APPENDIX H VISTA BLOOD BANK USER MANUAL SOFTWARE REQUIREMENTS SPECIFICATIONS

BLOOD BANK SPECIMEN COLLECTION PROCEDURE

Standardization and Evaluation of IgA and IgM Gel Column Agglutination for Direct Antiglobulin Testing

Table of Contents. FACT Quality Handbook, Second Edition. Table of Contents

Apheresis Program Management. Laura Collins BSN HP(ASCP) Assistant Manager DeGowin Blood Center University of Iowa Healthcare

ST. VINCENT'S. MEDICAL CENTER St. Vincent's Healthcare

Edwin Lindsay Principal Consultant. Compliance Solutions (Life Sciences) Ltd, Tel: + 44 (0) elindsay@blueyonder.co.

Flow Cytometry. CLIA Compliance Manual*

Time Frame 15 minutes. Student should strive to be able to perform multiple procedures simultaneously.

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

State Meat and Poultry Inspection (MPI) Program Laboratory Quality Management System Checklist

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

LIAISON XL HCV Ab Accurate diagnosis of the early stage of HCV infection

Position Classification Standard for Medical Technician Series, GS-0645

Blood System Inventory Management Best Practices Guide

Unit 8 Pretransfusion Compatibility Testing

Diagnosis of HIV-1 Infection. Estelle Piwowar-Manning HPTN Central Laboratory The Johns Hopkins University

Medical Cannabis Laboratory Approval Program

Northern Ireland Blood Transfusion Service

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

LAP Audioconference How to Prepare and Comply with Your Quality Management Plan* February 18, 2009

PERSONNEL: TRAINING PROCEDURE. C. Quality Management Systems (QMS) Manager:

The Role of the Laboratory in Clinical Trials. Basma Elgamal, M.D. Professor of Clinical Pathology National Cancer Institute, Cairo University

CAP Accreditation Checklists 2015 Edition

BLOOD DONOR TESTING & LOOKBACK STUDIES Shan Yuan, MD Last Updated 2/8/ ABO Typing: Performed each time with each donation

Preparing for the Pre-Approval Inspection What to do Before the FDA Arrives. Barry A. Friedman, Ph.D. Consultant

Red Blood Cell Transfusions for Sickle Cell Disease

STANDARD OPERATING PROCEDURE FOR THE DIRECT ANTIGLOBULIN TEST

2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests

STANDARD OPERATING PROCEDURE FOR RESOLVING ABO & Rh BLOOD GROUP DISCREPANCIES

GLOBAL FUND QUALITY ASSURANCE POLICY FOR DIAGNOSTICS PRODUCTS. (Issued on 14 December 2010, amended on 5 February 2014)

Welcome to Hibbing Community College s Online MLT Brochure!

VI. ABO and H Blood Groups

Design, Operation and Management of GTP/GMP Cell Engineering Facilities

Chapter. Guaiac Screening CHAPTER 4: GUAIAC TESTING SCREENING FOR OCCULT BLOOD. Page 1 of 5 Guaiac doc 6/24/2005

ABO-Rh Blood Typing Using Neo/BLOOD

How Does a Doctor Test for AIDS?

UCLA PATHOLOGY & LABORATORY MEDICINE QUALITY MANAGEMENT PLAN

LANE COUNTY B065 (Medical Assistant 1) Established: 4/13/05 B060 (Medical Assistant 2) Updated: 4/13/05 (Previous title: Medical Assistant)

Laboratory Procedure Manual. Rh Phenotyping

OSHA Compliance Checklist ASC

College of American Pathologists Accreditation for Public Health Laboratories

RTP s NUCLEAR QUALITY ASSURANCE PROGRAM

Content Sheet 3-1: Equipment Management Overview

Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians

Laboratory Accreditation. Personnel Qualifications. What s New? March 17, 2010

MEDICAL ASSISTANT 1 - Bilingual MEDICAL ASSISTANT 2 - Bilingual

New York State Department of Health Wadsworth Center Clinical Laboratory Reference System Clinical Laboratory Evaluation Program

THE PREPARATION OF SINGLE DONOR CRYOPRECIPITATE

CORD BLOOD EVALUATION

4A. Types of Laboratory Tests Available and Specimens Required. Three main types of laboratory tests are used for diagnosing CHIK: virus

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

Blood Typing Laboratory Exercise 40

MANAGING BLOOD AND BLOOD PRODUCT INVENTORY

Equipment Qualification

US Environmental Protection Agency Office of Pesticide Programs

Laboratory Director Responsibilities

SUBPART 58-5 Hematopoietic Progenitor Cell Banks

EDUCATIONAL COMMENTARY ANTIBODY TITRATIONS

Transcription:

XV.Quality Assurance in the Blood Bank A. Overview 1. Goals 2. Terms B. Record Keeping a. Safe transfusion b. Careful adherence to SOPs by trained personnel c. Develop comprehensive guidelines to be in compliance with JCAHO, FDA, AABB and CAP a. Quality control is the management of the testing process itself. 1) Monitoring of equipment and instruments 2) Determining that reagents are reacting appropriately. b. Quality Assurance includes the entire process of providing patient care, from the time the physician orders the test until treatment of patient based on results of test. 1) Were appropriate lab tests ordered to determine the need for transfusion. 2) Did the transfusion service perform appropriate testing of patient specimen and preparation of the appropriate component 3) Was the transfusion administered properly. 4) Did the patient obtain the anticipated benefit. c. Utilization review is the process of monitoring the appropriateness of transfusion. d. Continuous quality improvement involves reviewing the process of providing patient care with the goal of reducing rework, waste and inappropriate care. 1. Documentation is critical and must include: a. Quality monitoring standards based on regulatory and accrediting agencies b. Written plan and documentation of testing and review must be available to inspectors. c. Design forms for recording QC and quality assessment activities to provide an audit trail. d. Values obtained. e. Conclusions. f. Corrective actions taken. MLAB 2431 Unit 15 Quality Assurance in the Blood Bank 164

C. Procedure Manuals 1. SOPs are required for all laboratory and administrative procedures. 2. Procedures for blood bank slightly different than those for chemical based assays. 3. CLSI has recommended elements of a procedure manual. 4. Administrative policies and technical procedures should be maintained separately. B. Quality Assessment of Supplies and Reagents 1. Reagents may be made on site or purchased from a manufacturer. 2. Because of additional quality assessment requirements, most blood banks purchase reagents. 3. The following reagents must be tested each day of use: a. antihuman globulin serum b. blood grouping anti-serums c. lectins d. antibody screening cells e. reverse grouping cells f. enzymes 4. For donor collection facilities the following must be tested with each run: a. hepatitis testing reagents b. HIV testing reagents c. HTLV-I/II reagents d. ALT testing reagents e. syphilis serology reagents. 5. When reagents and supplies are received each of the following must be documented during the log in process: a. date of receipt b. manufacturer c. lot number d. expiration date e. review of manufacturer's circular for changes f. leaking or damaged containers 6. Before being placed in use reagents are tested for sensitivity and specificity. 7. Daily testing is required to ensure the reagent has not lost potency or reactivity. a. Can use a form and procedure created in-house or utilize QC kit provided by a manufacturer. b. Lot numbers and expiration date of all reagents tested must be on the form. c. Graded reactions recorded. d. Special typing sera need only be QCd when used. 8. Final disposition of damaged or unsatisfactory reagents must be documented. MLAB 2431 Unit 15 Quality Assurance in the Blood Bank 165

C. Equipment 1. Documentation must be made of routine maintenance, repairs and testing performed on instruments from date of receipt to date instrument is permanently removed from service. 2. Temperature monitoring is critical for refrigerators, freezers, incubators and waterbaths. D. Components a. Must be manually recorded daily. b. Refrigerators and freezers must have a device to record the temperature 24 hours a day. c. When temperature is out of range must have documentation of reason or corrective action taken. d. Alarms on refrigerators and freezers must be tested periodically to make sure they will sound at the appropriate temperature. 1. Each step of the preparation of components must be documented. 2. Periodically a unit is sacrificed to test for potency, efficacy and purity. a. At least four components are tested month. b. Three of the four must meet minimum requirements. E. Personnel 1. Personnel who perform tests and prepare components must have adequate education and training. 2. Must define tasks performed and levels of competence needed. 3. Must have a job description which should include the following: a. Title b. Brief description of general functions and responsibilities. c. Description of specific duties. d. Supervision e. Qualifications f. Special factors g. See page 548 for MT job description 4. Once job is defined can then determine level of education and training required. 5. Potential employees are interviewed and it will be determined if they are qualified based on the job description. 6. Must have a written training program and assessment to determine competency of the employee. a. Observation of the employee during job performance. b. Checklist to document employees progress. c. Procedures and policies change frequently so training is an ongoing process. MLAB 2431 Unit 15 Quality Assurance in the Blood Bank 166

7. Competency can be assessed by proficiency testing. a. Observing employee performing assigned tasks. b. Reviewing documentation. c. Assigning external proficiency testing samples on a rotating basis. d. Paper and pencil testing. e. Proficiency testing is used by accrediting and regulatory agencies to assess laboratory competency. F. Quality Assessment and Utilization Review 1. Most facilities use the 10 step process outlined by JCAHO. a. Assign responsibility b. Delineate the scope of care c. Identify the most important aspect of care d. Identify indicators e. Establish thresholds f. Collect and organize data g. Evaluate data h. Take corrective action i. Assess actions and document improvement j. Communicate. 2. Transfusion Committee a. Medical staff responsible for assessing adequacy of transfusion services and proper use of blood components. b. Reviews usage of all components for appropriateness. c. Reviews records of all transfusion reactions. d. Reviews order practices. 3. Quality Assessment Plan G. Utilization Review a. coordination of quality assessment activities. b. Select appropriate quality assessment indicators. c. Indicators are a reliable measure of the quality of service provided. d. Indicators selected to monitor high volume or high risk activities. 1. Required by JCAHO 2. Used to assess the blood ordering and transfusion practices of the medical staff. 3. Crossmatch:transfusion ratio a. Number of units crossmatched divided by the actual number transfused. b. Used as an indicator that too much blood is being requested to be on hold. c. Could result in high outdate or waste. 4. Number of autologous transfusion. MLAB 2431 Unit 15 Quality Assurance in the Blood Bank 167

5. Number of emergency releases. 6. Calculate statistics by physician. 7. Review of records to determine if transfusion was justified. 8. Audit criteria for transfusion must be defined: a. Hematocrit less than 24% b. Hemoglobin of less than 8 gm/dl c. Symptoms due to anemia d. Recent estimated blood loss of greater than 10% of total blood volume. e. If audit reveals unjustified transfusion physician is notified and asked to respond. The End MLAB 2431 Unit 15 Quality Assurance in the Blood Bank 168