B-Series Temperature Switches

Similar documents
B-Series Switches Pressure, Differential Pressure & Hydraulic

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Compact pressure switch Flameproof enclosure Ex d Model PCA

Electronic, Digital and Mechanical Vibration Switches

In-Line Electronic Flow Switches

Electronic Flow Switches

Explosion-Proof Electric Unit Heaters

Scraper Passage Indicator. Electrical Indicator. Features

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Sanitary Type Electronic Flow Switches

P70, P72, and P170 Series Controls for Dual Pressure Applications

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

! WARNING. Before using product, read and understand instructions.

Flow switches Series AD/VH

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

8146/5 Series Breaker Panelboards

Thermometer in stainless steel with capillary and switch contacts

Centro-Matic Automatic Lubrication Systems System Controls

Pressure Switch for gas and air

Commercial Gas Cooking Thermostats

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

In-Line Electronic Flow Switches

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Worcester DS/DM Series UltraSwitch Switch box

Microcor Wireless Transmitter (MWT)

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

Electric Process Heaters & Engineered Systems

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

V47 Series Temperature Actuated Modulating Water Valves

Plastic tube flowmeters Series PT/PS

Part I - Installation

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Product Brochure. Certified Mining Motors

DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

T7079A,B Solid State Remote Temperature Controllers

Linear Luminaire with LED Series EXLUX 6402/2

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Explosion proof enclosures

Screw Plug Immersion Heaters

Micro Motion Model D and DL Coriolis Flow and Density Meters

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Honeywell Pressure Switches Line Guide

REGULATORS 175/153 Series

VIBRATION SWITCHES SOLID STATE

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

9000 Series Accelerometers Specifications

Thermostatic valve Type AVTA

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

OPTIMASS 6000 Technical Datasheet

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Technical Information RIA14

COMBIMASS. Technical Data COMBIMASS eco-bio +

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

SITRANS F flowmeters SITRANS F M

Electronic Pressure Switches

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Flameproof Audible Signal 115 db (A) Series YA90

36T Series Snap-Action Temperature Controls

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Control and Distribution Boxes made of Stainless Steel Series 8150

Rosemount 751 Field Signal Indicator

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

4 Posiflow Proportional Solenoid Valves

OPTIMASS 1400 Technical Datasheet

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Liquid Level Limit Switch liquiphant T FTL 20

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

SECTION MORTUARY REFRIGERATORS

A99B Series Temperature Sensors

B40 Liquid Level Switch

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

Pipe Temperature Sensors

Bimetal thermometer Model 52, industrial series

PIEZOMETER AIRFLOW MEASURING RING

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI

Flow Monitoring System

Terminal Boxes Series 8146

FCI ST75 Series Flow Meters

Heating, air-conditioning, cooling

Transcription:

FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment plants Other corrosive environments Ashcroft Inc. supplies highly reliable Ashcroft switches and controls for industrial and process applications. We begin with rock-solid designs, matching the most appropriate technology with the safety and reliability requirements of the applications. The materials of construction are specified to Ashcroft s exacting standards, and product is built to last in the toughest applications. Our modern, responsive manufacturing facility is supported by an extensive network of stocking distributors and factory sales offices located in virtually every part of the world. Special application assistance is always just a telephone call away. The Ashcroft B-Series switch line is designed to satisfy most switch requirements. Materials of construction have been selected for long life. A wide variety of precision switch elements are available to meet every application requirement, including hermetically sealed contacts for added reliability and safety. The actuators we use have been proven in more than 20 years of service in the world s plants and mills. Special designs are available for fire safety, NACE, limit control and other more stringent requirements. Simplicity and ease of use are stressed to improve reliability of the installation. Applications include: pumps, compressors, washers, filters, degreasers, evaporators, recovery systems, food processing, ground support equipment, reverse osmosis systems, heat exchangers, hydraulic systems, lubrication systems, marine equipment, textile machinery, heating and air conditioning equipment. Thermowells Thermowells must be used on any application where the stem of the temperature switch may be exposed to pressure, corrosive fluids or high velocity. Additionally, the use of a thermowell permits instrument interchange or calibration check without disturbing or closing down the process. Ashcroft temperature switches have bulb diameters to match 3 8 nominal bore thermowells. The bulbs have a sensitive portion length of 2 which can be used with 2 2 U dimensioned thermowells or longer. For maximum accuracy, a thermowell s U dimension should be selected to permit complete immersion of the sensitive portion plus when measuring the temperature of liquids; an extra 3 should be allowed when measuring the temperature of gases. Thermowell bushings should be used with remote mount temperature switches. We recommend the standard 3 bulb and code 69 Series bushings for use with any thermowell U dimension. A split rubber grommet allows easy installation and S dimension adjustment. All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc. 204 0/4 Ashcroft Inc., 250 East Main Street, Stratford, CT 0664 USA Tel: 203-378-828 Fax: 203-385-0408 email: info@ashcroft.com www.ashcroft.com

Temperature Switches B-Series temperature switches feature a SAMA Class II vapor pressure thermal system. This system provides quick, accurate response to process temperature changes with negligible ambient temperature effects. This is inherent in the design due to the precise relationship that exists between temperature and pressure according to the vapor pressure laws. A wide selection of sensing bulb and armored capillary lengths is available. The vapor pressure system design features small bulb sizes, making installation easy and cost-effective. All models feature ±.0% percent of span setpoint repeatability with very high overtemperature ratings. These standard designs perform well in applications where shock and vibration could be a problem and should be used with Ashcroft thermowells for bulb protection and ease of installation and maintenance. STANDARD TEMPERATURE RANGE SELECTION Nominal Range (),(5) Maximum Temperature Approximate Deadband () Switch Element (4) F C F 20, 26, 27 2, 24, 3 50 22 32, 42 40 to 60 40 to 60 400.0-2.0 3.0-8.0.5-5.5.4-6.0 8.0-6.0 0 to 00 20 to 400 400.5-3.0 5.0-2.0 2.2-8.5.5-7.5 9.0-20.0 75 to 205 20 to 95 400.5-3.5 8.0-6.0 2.5-2.0 2.0-9.0 0.0-24.0 50 to 260 65 to 25 400.5-3.0 5.0-2.0 2.2-8.5 2.0-9.0 0.0-24.0 235 to 375 0 to 90 500.5-3.5 5.0-2.0 2.5-8.5 2.0-9.0 0.0-24.0 350 to 525 (3) 75 to 275 700 2.0-4.5 8.0-6.0 3.2-2.0 2.5-0.0 5.0-34.0 500 to 750 (2) 260 to 400 900 4.0-8.0 6.0-30.0 7.2-24.0 5.0-23.0 30.0-50.0 NOTES: All deadbands given in F. 2 Available with remote mount thermal systems only. 3 Not available with 2 3 4 stem. 4 Dual switch element multiply single switch element value by.6 for approximate deadband. 5 Set and reset points must fall within the adjustable range.

B-SERIES TEMPERATURE SWITCH MODEL NUMBER: To specify the exact switch desired, select entries from appropriate tables as shown in example below. 2 3 4 T 4 2 0 T 0 5 030 5 X N H 6 50 to 260 F T4 T7 ENCLOSURE Temperature switch, Type 400, watertight enclosure meets NEMA 3, 4, 4X, 3 and IP66 requirements. Temperature switch, Type 700, explosion-proof enclosure meets Div. & 2, NEMA 7, 9 and IP66 requirements. 2 SWITCH ELEMENT SELECTION Order Switch Elements Code UL/CSA Listed SPDT 20 (7) Narrow deadband ac 5A, 25/250 Vac 2 Ammonia service 5A, 25/250 Vac 22 (6) Hermetically sealed switch, 5A, 25/250 Vac narrow deadband 23 Heavy duty ac 22A, 25/250 Vac 24 () General purpose 5A, 25/250/480 Vac 2A, 25 Vdc 4A, 250 Vdc; 6A, 30 Vdc 25 Heavy duty dc 0A, 25 Vac or dc, 8 HP, 25 Vac or dc 26 (7) Sealed environment proof 5A, 25/250 Vac 27 High temperature 300 F 5A, 25/250 Vac 28 (5) Manual reset trip on 5A, 25/250 Vac increasing 29 (5) Manual reset trip on 5A, 25/250 Vac decreasing 3 Low level (gold) contacts A, 25 Vac 32 Hermetically sealed switch, A, 25/250 Vac general purpose 5A, 30 Vdc 42 Hermetically sealed gold A, 25 Vac contacts 50 Variable deadband 5A, 25/250 Vac UL/CSA Listed Dual (2 SPDT) 6 (7) Dual narrow deadband 5A, 25/250 Vac 62 (7) Dual sealed environment 5A, 25/250 Vac proof 63 Dual high temp. 300 F 5A, 25/250 Vac 64 Dual general purpose 5A, 25/250/480 Vac 2A, 25 Vdc 4A, 250 Vdc 65 Dual ammonia service 5A, 25/250 Vac 67 (4,6) Dual hermetically sealed 5A, 25/250 Vac switch, narrow deadband 68 (4) Dual hermetically sealed A, 25/250 Vac switch, general purpose 5A, 30 Vdc 70 Dual low level gold contacts A, 25 Vac 7 (4) Dual hermetically sealed A, 25 Vac switch, gold contacts 3 THERMAL SYSTEM SELECTION Direct Mount Order Code System Material Style TS 3l6 SS Rigid Remote Mount Order Code System Material Line Length Style T05 36 SS 5 Capillary T0 36 SS 0 with T5 36 SS 5 302 SS T20 36 SS 20 Spring T25 36 SS 25 Armor 4 BULB SELECTION Direct Mount Minimum Order S Thermowell Code Dimension U Dimension 027 (8) 2 3 4 040 4 2 2 060 6 4 2 090 9 7 2 20 2 0 2 Remote Mount 030 3 2 2 5 OPTIONS Use table on page 7 6 STANDARD TEMPERATURE RANGE SELECTION Adjustable Range F C 40 to 600 40 to 60 0 to 00 20 to 400 75 to 205 20 to 95 50 to 260 65 to 25 235 to 375 0 to 90 350 to 525 75 to 275 500 to 750 (2) 260 to 400 NOTES: Standard switch. 2 Available with remote mount thermal systems only. 3 Dual switches are 2 SPDT snap-action switches, not independently adjustable. 4 Wires cannot be terminated inside T400 switch enclosure. 5 Not available with Type 700 enclosure. 6 Estimated dc rating, 2.5A, 28 Vdc (not UL listed). 7 Estimated dc rating, 0.4A, 20 Vdc (not UL listed). 8 Not available on 350 to 525 F. 9 Consult factory on remote mount for bulb lengths other than 3.

B-Series Switches Temperature OPTIONAL FEATURES AND ACCESSORIES B-SERIES SWITCH OPTIONS Appicable Switch Series Temperature Code Description All Ranges Notes XBX 2 Male NPT Bushing XCH Chained Cover XC8 CSA Approval XCN ATEX Directive 94/9/EC 2 XFP Fungus Proofing XFS Factory Adjusted Setpoint 3 XJK Left Conduit Connection 4 XJL 3 4 to 2 Reducing Bushing XJM Metric Electrical Conduit Connection M20 x.5 XK3 Terminal Block (700 Series only) 5 XLE 6 foot Leads on the Micro Switch XNH Tagging Stainless Steel XNN Paper Tag XPK Pilot Light(s) Top Mounted 6 XPM 3 4 Sealed Conduit Connection with 6 Lead Wires XTM 2 Pipe Mounting Bracket XUX IECEx Rating (700 Series only) NOTES: Standard on 400 Series. 2 700 Series only. 3 Advise static or working pressure for differential pressure switches. 4 Standard on 700 Series. N/A with DPDT element on 400 Series. 5 Terminal Blocks standard with 700 dual switches. 6 N/A on 700 Series. II 2GD Ex d IIC T6 Gb Ex t IIIC T85 C Db IP 6X (Ta = 20 C to +60 C)

Dimensions 400 Series Temperature switch direct mount Temperature switch remote mount 0.22 (6) 4.03 (02) Ø 0.28 (7) X 3 HOLES 2.27 (58).25 (32) 0.25 (6) 0.22 (6) 4.03 (02) Ø 0.28 (7) X 3 HOLES 2.27 (58).25 (32) 0.25 (6) 4.6 (7) 3.32 (84) 2.77 (70) 3/4 NPT 2.00 (5) 4.6 (7) 3.32 (84) 2.77 (70) 3/4 NPT 2.00 (5) 7/8 HEX Ø 3.26 (83) /2 NPT MALE.3 (33) S Ø 2.50 (64) L Ø 0.37 3.26 (83) Ø 0.37 3.00 (76) Temperature switch direct mount Temperature switch remote mount Ø 0.28 x 3 HOLES (7) 5.23 (33) 3.60.37 (35) 5.20 (32) 2.8 (55) 0.32 (8) Ø 3.90 (99) 3/4 NPT 2 HOLES.22 (3) 3.58 0.03 () 0.3 (8) Ø 0.28 x 3 HOLES (7) 3.6 (92) 5.23 (33) 5.20 (32) 2.8 (55) 0.32 (8) Ø 3.90 (99) 3.58.22 (3) 0.03 () 0.3 (8) 4.37 ().93 (49) 7/8 HEX /2 NPT MALE 0.37.3 (33) S.37 (35) 4.37 ().93 (49) 3/4 NPT 2 HOLES 2.50 (64) L 3.00 (76) Ø 0.37

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc. 204 0/4 Ashcroft Inc., 250 East Main Street, Stratford, CT 0664 USA Tel: 203-378-828 Fax: 203-385-0408 email: info@ashcroft.com www.ashcroft.com