Innovation with CFD. Solutions and Equipment

Similar documents
Introduction to Computational Fluid Dynamics (CFD) for Combustion. (801)

THE OPTIMISATION OF BIOMASS COMBUSTION IN SMALL BOILERS

ME6130 An introduction to CFD 1-1

GT ANALYSIS OF A MICROGASTURBINE FED BY NATURAL GAS AND SYNTHESIS GAS: MGT TEST BENCH AND COMBUSTOR CFD ANALYSIS

Assignment 8: Comparison of gasification, pyrolysis and combustion

Latest Low-NOx Combustion Technology for Pulverized-coal-fired Boilers

Graduate Certificate Program in Energy Conversion & Transport Offered by the Department of Mechanical and Aerospace Engineering

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Continuous flow direct water heating for potable hot water

The soot and scale problems

CFD Analysis of a MILD Low-Nox Burner for the Oil and Gas industry

SULFUR RECOVERY UNIT. Thermal Oxidizer

Assessing the Changes Required by the Industrial Boiler MACT Regulations

Waste to Energy. Anders Damgaard. Thanks to Jiri Hyks and Thomas H Christensen DTU for some slides

Efficiency on a large scale CFB Steam Boilers

Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology

Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi

Waste Incineration Plants

2nd IEA Oxyfuel Combustion Conference

Developments and trends shaping the future for Waste-to- Energy technology suppliers

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

Stora Enso Fors Ltd Sweden

RESEARCH PROJECTS. For more information about our research projects please contact us at:

CFD Simulation of Biofuel and Coal Co-Combustion in a Pulverized Coal Fired Furnace

CONVERGE Features, Capabilities and Applications

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

High Flux Steam Reforming

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

of 11,000 households Steam temperature, boiler 400 C Steam pressure, boiler Incineration temperature 1,100 C

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

VALIDATION, MODELING, AND SCALE-UP OF CHEMICAL LOOPING COMBUSTION WITH OXYGEN UNCOUPLING

Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics

Part IV. Conclusions

International Master of Science Degree Program

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

NAWTEC CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY

Weiss A/S Presentation. by Bo Johansen

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

IMPROVING ENERGY EFFICIENCY IN CEMENT PLANTS

Investigating the Impact of Boiler Aging In Replacement Decisions

Biogas. creating the future

CFD Grows Up! Martin W. Liddament Ventilation, Energy and Environmental Technology (VEETECH Ltd) What is Computational Fluid Dynamics?

CFD MODELLING OF TOP SUBMERGED LANCE GAS INJECTION

Lecture 3 Fluid Dynamics and Balance Equa6ons for Reac6ng Flows

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

COKE PRODUCTION FOR BLAST FURNACE IRONMAKING

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

Pros and Cons. of CFD and Physical Flow Modeling. A White Paper by: Kevin W. Linfield, Ph.D., P.E. Robert G. Mudry, P.E.

CFD STUDY OF TEMPERATURE AND SMOKE DISTRIBUTION IN A RAILWAY TUNNEL WITH NATURAL VENTILATION SYSTEM

ERK Eckrohrkessel GmbH (2016) 1. Powerful First-Class Boiler and Combustion Systems & Complete Engineering Services

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Basic Equations, Boundary Conditions and Dimensionless Parameters

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

6 CONSIDERATION OF ALTERNATIVES

HYBRID ROCKET TECHNOLOGY IN THE FRAME OF THE ITALIAN HYPROB PROGRAM

Gasification as means of Waste-to-Energy - Main Parameters and application -

THERMAL STRATIFICATION IN A HOT WATER TANK ESTABLISHED BY HEAT LOSS FROM THE TANK

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Biogas as transportation fuel

CFD Application on Food Industry; Energy Saving on the Bread Oven

Aerodynamic Department Institute of Aviation. Adam Dziubiński CFD group FLUENT

Waste a source of energy. Regional Solid Waste Management Plan Review: Engaging solutions for tomorrow. Incineration. Incineration

ENHANCED PROBLEM SOLVING; THE INTEGRATION OF CFD AND OTHER ENGINEERING APPLICATIONS

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

HEAT TRANSFER IM LECTURE HOURS PER WEEK THERMODYNAMICS - IM _1

Safety aspects of solid biomass storage, transportation and feeding. Jaap Koppejan (Task 32)

New Burner Technology for Low Grade Biofuels

ATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

Technical Solutions for Emissions Reduction

Introduction to Waste Treatment Technologies. Contents. Household waste

CFD Beyond the Whitespace. Datacentres Central & Eastern Europe

SBi 2013:12. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

Introduction to CFD Analysis

TODAY S THERMAL OXIDIZER SOLUTIONS TO MEET TOMORROW S CHALLENGES

Basic Principles in Microfluidics

A Review of Biomass Boiler Technologies. Fernando Preto CanmetENERGY, Natural Resources Canada

Haldor Topsøe Catalysing Your Business

Maximization versus environmental compliance

Boiler efficiency measurement. Department of Energy Engineering

EVALUATION OF PHOENICS CFD FIRE MODEL AGAINST ROOM CORNER FIRE EXPERIMENTS

Using OpenFOAM to model of complex industrial devices

Euler-Euler and Euler-Lagrange Modeling of Wood Gasification in Fluidized Beds

Babcock & Wilcox's IR-CFB Boiler Technology. S. P. Ganeshan. Papertech -2010, Hyderabad. Divisional Manager, Thermax Limited, Boilers & Heaters Group

The Fate of Ammonia and Mercury in the Carbon Burn-Out (CBO ) Process

CFD SIMULATION OF NATURAL GAS COMBUSTION AND IST APPLICATION TO TUNNEL KILN FIRING

WASTES INCINERATION PLANTS

INITIAL ASSESSMENT OF THE IMPACT OF JET FLAME HAZARD FROM HYDROGEN CARS IN ROAD TUNNELS AND THE IMPLICATION ON HYDROGEN CAR DESIGN

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Work and Energy. Work = Force Distance. Work increases the energy of an object. Energy can be converted back to work.

Effect of Aspect Ratio on Laminar Natural Convection in Partially Heated Enclosure

Fired Heater Design and Simulation

Computational Fluid Dynamics (CFD) and Multiphase Flow Modelling. Associate Professor Britt M. Halvorsen (Dr. Ing) Amaranath S.

Energy Saving Fact Sheet Boilers

Transcription:

Innovation with CFD Solutions and Equipment

2 Innovation with CFD

Why our customers choose us According to our customers, we: Possess exceptional experience in our chosen technologies Possess unique abilities in both waste disposal and bio-fuels Understand the details as well as the big picture Have a strong environmental commitment Are honest and openminded partners Never compromise on the end result Never walk away from an unfinished project, no matter how difficult it is Are highly competitive ISO 9001:2008 certified quality system Innovation with CFD Solutions and Equipment Babcock & Wilcox Vølund is one of the world s leading suppliers of equipment and technologies for converting waste and bio-fuels into thermal energy. Our solutions uniquely combine: High-quality products Broad multi-disciplinary experience Use of the latest know-how within heat transfer and combustion Strong project management skills Babcock & Wilcox Vølund 3

Facts at a glance Headquarters in Esbjerg, Denmark and branch office in Copenhagen, Denmark 100% owned by Babcock & Wilcox Power Generation Group, Inc. More than 500 production lines have been built based on our technologies. Many of these are still in use today. Our companies currently employ over 10,000 people worldwide approximately 400 are employed by Babcock & Wilcox Vølund. 4 Innovation with CFD

A pioneer in the industry Babcock & Wilcox Vølund has more than 80 years of experience in designing waste-toenergy and bio-fuel plants. We have been using state-of-the-art CFD design tools since 1996. B&W Vølund uses the CFD software Fluent, which is the CFD software with the most extensive waste incineration and boiler specific reference list. Babcock & Wilcox Vølund has developed submodels to optimise the application of CFD to the waste-to-energy industry. These submodels were developed in co-operation with the Sheffield University Waste Incineration Centre (SUWIC). On-going development of our sub-models is carried out in co-operation with Lunds Technical University, Aalborg University, The Technical University of Denmark and the Danish industrial research centre Force Technology. Babcock & Wilcox Vølund uses CFD analysis to deal with issues such as: LONGER LIFETIME THROUGH OPTIMUM FLOW AND TEMPERATURE CONDITIONS REDESIGN DUE TO CHANGING CALORIFIC VALUES OF FUEL INCREASING PLANT CAPACITY, IN SOME CASES BY AS MUCH AS 25% INJECTION OF COOLING WATER, LEACHING WATER OR SLUDGE OPTIMISATION OF COMBUSTION AIR OPTIMUM BURNER POSITION VERIFICATION OF RESIDENCE TIME EMISSION CONTROL CFD is today one of the major keystones in our technology design. CFD is a simulation tool which uses a number of mathematical methods for handling physical and chemical phenomena. Detailed know-ledge of these methods is required to carry out the analysis. A CFD analysis provides a detailed representation of the combustion process, flow field and heat transfer. The tool is therefore excellent for simulating industrial processes. The detailed chemical and physical information obtained for plants by CFD helps us create the best solution for our customers. CFD gives B&W Vølund the ability to check the design with respect to a large number of critical factors such as velocities, particle impingement, oxygen level, temperature and surface temperature. The customer will therefore receive a plant which is optimised for better environmental performance and which can provide longer and more reliable operation. Factors such as the locations of air injection nozzles, wall heat transfer properties and local geometry features are therefore all investigated thoroughly during the design phase. Babcock & Wilcox Vølund 5

Flow from first to second pass in boiler New plant CFD simulations are carried out, when designing a new plant, to determine the geometry of the furnace and boiler, positions of air inlet nozzles and burners and the expected temperature distribution. Using CFD analysis ensures very high quality design, which B&W Vølund is recognized for. Secondary air is added via nozzles in the furnace front and back ceiling and at one or more levels in the first boiler pass. The nozzles in the first boiler pass generate the VoluMix system. The VoluMix system generates the micro and macroscopic mixing which is required to ensure final burn-out of CO and particles. We place great emphasis in the design phase on achieving uniform flow through the boiler, as this gives the most efficient heat transfer, lowest wear and corrosion risk and optimum retention time in which combustion can take place. VoluMix seen from the furnace 6 Innovation with CFD

Service Case When a plant needs to be upgraded, we combines CFD analysis with the experience available at B&W Vølund to provide solutions to the many technical problems in the wasteto-energy and biomass combustion industry. CFD is a very efficient method for evaluating different design alternatives which otherwise are too expensive, too time consuming or impossible to test in an operating plant. We, working with the customer, analyse the present situation at the plant and verify solutions to ensure we arrive at optimised plant operation. For example, optimal design of the secondary air system will solve problems such as high emission levels or poor particle combustion. Optimisation of the secondary air system in many cases will also increase capacity. The location of secondary combustion air nozzles and air jet velocity are the two major design parameters for the secondary combustion air system. Secondary air nozzles before optimisation. The air is distributed across four locations and injected at relatively low velocities. One row of nozzles in the front ceiling, one row in the top ceiling and four nozzles on each side over the last grate. Secondary air nozzles in the optimised case. Air is injected through two high speed nozzles in the front ceiling. Vectors indicate the direction of secondary air flow and the location of nozzles. Babcock & Wilcox Vølund 7

The velocity distribution before (left side) and after (right side) optimisation. Velocity vectors before optimisation (left) indicate bulk flow heading directly from the grate to the entrance of the boiler. A large recirculation zone occupies the front of the furnace. The entire furnace volume is therefore not used for combustion. After optimisation (right), the gas mixture leaving the grates is drawn towards the front of the furnace and mixed with air from the ceiling nozzles and burned, before leaving the furnace. Before optimisation (left), CO combustion is not completed at furnace outlet. After optimisation (right), the secondary air system creates a vortex which draws the CO into the front of the furnace, thus enabling complete CO burnout. Temperature distribution ( C) for the same furnace. Comparison of the temperature distributions shows that heat is concentrated at the front of the furnace (right) due to CO combustion. This further accelerates waste drying. Waste load may therefore be able to be increased, depending on the capacity of the rest of the plant. 8 Innovation with CFD

Numerical Laboratory A CFD model is based on control volumes. The furnace and boiler which are to be modelled are divided into small volumes. These volumes adjoin each other or the wall, the outlet or the inlet. The momentum, the mass and the energy conservation equations are solved for each control volume. The quality of the solution is therefore to a great extent dependent on the number, shape and position of the control volumes. In addition to solving the momentum (Navier- Stokes), mass and energy conservation equations, the equations describing turbulence, chemical reactions, transport of particles and radiation are also solved. A large proportion of the energy recovered from waste (between 30% to 50%) is released as combustible gases (CO, H 2, CH 4, etc.) in the furnace. Gas phase combustion is therefore also modelled to describe the entire combustion process. Incineration in the solid fuel bed is simulated using a separate empirical model that is based on test data. Radiation contributes more than 90% of heat transfer in the furnace and the first pass of the boiler. Radiation modelling is therefore essential if a correct image of temperature and flow are to be obtained. describes how impulse, pressure and viscosity forces influence the fluid in the cell. The impulse momentum equation for fluids is known as the Navier-Stokes equation. Mass conservation is the other basic equation. Mass neither arises nor disappears in a control volume unless otherwise specified by the user. Combining the impulse momentum equation with the mass conservation equation allows us to create an expression for the three velocity vectors and the pressure for each cell. Turbulence Turbulence plays a major role in flow. When the viscous stresses in the fluid reach a specific level, the laminar flow pattern will break up and small vortexes are formed. New vortexes are formed and broken down to even smaller vortexes. The majority of these vortexes are considerably smaller than the cells in the CFD model. Turbulence in the CFD model is therefore described using a separate model. Particles contribute to the heat release and heat transfer. Depending on the type of feeding and grate system the heat release due to particles vary from 5% - 70% of the total heat release. For a suspension type feeding system the heat release produced by particles is high and for a pusher type system it is low. The transport and combustion of particles are therefore also modelled. Flow Transport of fluid is described by an impulse momentum equation for each dimension (3D) and a mass conservation equation. The impulse momentum equation (Newton s Second Law) Typical computational grid. The grid is refined in areas where there are large changes in the flow field, e.g. at air nozzles and guide vanes. The grid consists of around 250,000 cells. Babcock & Wilcox Vølund 9

Heat transfer Wall boundaries are all modelled as reflective and adjusted to the expected heat transfer, which is dependent on the covering of the boiler walls. Turbulent boundary layer Buoyancy Buoyancy play a important role in thermal flow where there are large temperature differences. The flue gas is cooled as it passes along the walls in the two radiation passes. The cooled flue gas found along the walls is heavier than the flue gas in the middle of the pass. Hot flue gas will rise and cold flue gas will fall. There is therefore a balance between gravity of the cooled fluid and the amount of movement in the hot flue gas. Heat transfer in furnaces and boilers is controlled by radiation. The majority (70-100%) of heat transfer from gas to boiler wall and gas to gas is by radiation. Radiation is modelled using the DO (Discrete Ordinates) model, which is a discrete beam model. The DO model is very suitable for situations where there are large variations in temperature and emissivity. The CFD model also includes convection and heat conduction. Combustion Combustion can be subdivided into a number of different phases: DRYING OUT PYROLYSIS IGNITION GASIFICATION COMBUSTION CARBON COMBUSTION SLAG FORMATION The processes that take place in the fuel layer on the grate are simulated by a special standalone software program developed by B&W Vølund. The effects of the fuel layer processes are included in the model by adjusting the source terms in the modelled fuel layer. Model of solid bed combustion 10 Innovation with CFD

The chemical reaction model must include the main flue gas components (N 2, CO 2, H 2 O and O 2 ) if the thermal properties of the flue gas are to be successfully modelled. Gas phase combustion should contain the primary gasification products. The global reaction scheme in the CFD simulation is divided into the following detailed reaction scheme of three reactions: CH 4 + 1.5 O 2 CO + 2 H 2 O CO + 0.5 O 2 CO 2 CO 2 CO + 0.5 O 2 The first two reactions are limited by the mixing and the reaction rate. The last backward reaction is controlled by the reaction rate alone. Particles Particle substances are carried away from the fuel layer during combustion. These solids or particles contain combustible material which can be seen in the furnace as visible yellow flames. Combustion Air Combustion air is subdivided into four main groups: PRIMARY AIR SECONDARY AIR TERTIARY AIR COOLING AIR The volume of primary air needs to be adjusted so that there is sufficient air at the grate. Secondary air is added via nozzles at the furnace front and back ceiling and in the first boiler pass. The secondary air system must be designed so that it can handle CO released from across the entire grate, because dry fuel will gasify at the front end of the furnace while wet low quality fuel will gasify in the middle of the furnace. It can furthermore be expected that irregularities in the fuel will cause increased short time CO release from all parts of the grate. These particles will follow the flow, combusting and consuming oxygen and releasing heat and combustion products. These particles will also change the radiation properties of the gas. Consequently, the optical thickness of the gas will increase giving higher levels of radiation. Further particles impinging on the heated surface are a corrosion factor. Particle paths from different grate sections Babcock & Wilcox Vølund 11

Gas phase burn-out is principally controlled by four factors: 1. TEMPERATURE 2. CONCENTRATION OF O 2 3. TURBULENCE 4. RETENTION TIME Flue gas temperatures must be above 800 C for high chemical reaction rates for the combustion of CO to be achieved. Turbulence is very often the parameter which has the greatest influence on CO burn-out. CO and O 2 must therefore be brought together for CO combustion to take place. The reaction between CO and O 2 to form CO 2 takes a few milliseconds. Microscopic pockets of CO rich areas, O 2 rich areas and CO 2 -rich areas are created in the flue gas. Both micro and macroscopic mixing is therefore required to bring these pockets of CO and O 2 together. Secondary air nozzles are required to create about this mixing (= turbulence). Secondary air will add mixing energy to the furnace area the more energy added, the better the burnout. The location and the number of nozzles is an important factor, as we want mixing to be carried out in the correct areas. Wood chips burning in suspension. Coloured according to particle diameter and state of combustion 12 Innovation with CFD

As the process requires a certain reaction time, residence time is an important factor in the determination of the degree of burn-out. Residence time however primarily influences processes which are diffusion controlled i.e. particle combustion. After particle gasification, there is a comparatively long sequence in which the remaining solid carbon content is combusted. If oxygen is present, it will diffuse towards the surface of the particle where it reacts with the carbon releasing CO and CO 2. It is therefore important that particles have a long residence time in the presence of oxygen and sufficiently high temperatures (>800 C) if a high degree of burn-out is to be achieved. This is primarily secured by the flow pattern in the furnace and 1. pass of the boiler. Iso surfaces with O 2 coloured by temperature Babcock & Wilcox Vølund 13

Lectures and publications Ole Hedegaard Madsen, Siegfried Binner, Kenneth Jørgensen; THERMAL OPTIMIZATION AND POL- LUTANT CONTROL IN MSW INCINERATION PLANTS, 4th European Conference on Industrial Furnaces and Boilers, INFUB, Espinho, Portugal, 1-4 April 1997. Ole Hedegaard Madsen; NUMERICAL MODELLING OF FURNACES AND BOILERS, Copenhagen Waste & Water 97, Copenhagen, Denmark, 1-4 April 1997. Ole Hedegaard Madsen, Siegfried Binner, Kenneth Jørgensen; MODERN DESIGN TECHNOLOGIES FOR THERMAL OPTIMIZATION AND POLLUTANT CONTROL IN MSW INCINERATION PLANTS, First International Symposium on Incineration and Flue Gas Treatment Technologies, Sheffield University, UK, 7-8 July 1997. Ole Hedegaard Madsen, Siegfried Binner, Jens Christian Jensen; THERMAL OPTIMIZATION AND POLLUTANT CONTROL IN MSW INCINERATION PLANTS, Pollution Control 97, International Conference on Pollution Prevention and Control, Bangkok, Thailand, 12-14 November 1997. Kenneth Jørgensen, Ole Hedegaard Madsen; MODERN CONTROL SYSTEMS FOR MSW PLANTS, Second International Symposium on Incineration and Flue Gas Treatment Technologies, Sheffield University, UK, 4-6 July 1999. Ole Hedegaard Madsen; APPLICATIONS AND EXPERIMENTAL DATA FROM COMPUTATIONAL FLU- ID DYNAMICS, ISWA Seminar, The latest technical Development, Malmö, Sweden, 1999. K. Jørgensen, E. Meier, O. H. Madsen; HIGH EFFICIENCY BIO-MASS BOILER, accepted for presentation at the 5th European Conference on Industrial Furnaces and Boilers, INFUB, Porto, Portugal, 11-14 April 2000. Ole Hedegaard Madsen, Kenneth Jørgensen, Sang Soon Chung; INCREASING THE COMBUSTION CAPACITY AND THE PERFORMANCE OF EXISTING WASTE INCINERATION PLANTS BY MODERN DESIGN TECHNOLOGY, International Conference on Combustion, Incineration/Pyrolysis and Emission Control (ICIPEC), Seoul, Korea, June 8-10 2000. Kenneth Jørgensen, Paw Andersen, Ole Hedegaard Madsen; MODERN TECHNOLOGY FOR BURN- ING RDF WASTE, Third International Symposium on Incineration and Flue Gas Treatment Technologies, Brussels, 2-4 July 2001. Ole Hedegaard Madsen; NEW TECHNOLOGIES FOR WASTE TO ENERGY PLANTS, 4th International Symposium on Waste Treatment Technologies, Sheffield, UK, 29 June 2 July 2003. Per Ankersen, Paw Andersen; IMPROVING THE CAPACITY OF A MSW INCINERATION PLANT, Progress in Computational Fluid Dynamics, vol. 7, no. 5, 2007. Thomas Norman, Paw Andersen, Ole Hedegaard Madsen; DEVELOPMENT OF AN IMPROVED SEC- ONDARY AIR SYSTEM USING CFD, VENICE 2012 4th International Symposium on Energy from Biomass and Waste, Venice, Italy, 12-15 November 2012 14 Innovation with CFD

Long reference list CFD analysis provides a detailed representation of the combustion process, flow field, and heat transfer. The detailed chemical and physical information obtained for plants by CFD helps us create the very best solution for our customers. We have been using the CFD design tool on more than 120 projects since 1996. We use CFD when we design new plants and in our service business when upgrading older plants. Babcock & Wilcox Vølund 15

Babcock & Wilcox Vølund is one of the world s leading suppliers of equipment and technologies designed to convert waste and bio-fuels into thermal energy. Founded in 1898 and headquartered in Esbjerg, Denmark, the company is 100% owned by Babcock & Wilcox Power Generation Group, Inc. in Barberton, Ohio, USA. Our companies currently employ over 10,000 people worldwide of which over 400 are employed by Babcock & Wilcox Vølund. Denmark Babcock & Wilcox Vølund A/S Falkevej 2 DK-6705 Esbjerg Ø Denmark Tel.: +45 7614 3400 Fax: +45 7614 3600 www.volund.dk 541-856 Svanemærket tryksag Babcock & Wilcox Vølund s design, engineering, sales, service, and manufacturing facilities in Denmark: Esbjerg Glostrup/Copenhagen The information contained herein is provided for general information purposes only and is not intended or to be construed as a warranty, an offer, or any representation of contractual or other legal responsibility. 2013 Babcock & Wilcox Vølund A/S. All rights reserved.