Protec. Protec Algo-Tec TM 6300 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable



Similar documents
FIREDEX Conventional Fire Panels

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Repeaters and Mimics Data Sheet

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

CB200W Water Leak Detection Panel Application Guide

MINERVA MX MX Virtual Multi-Sensor Detectors

VEGA Analogue Addressable Control Panels

Analogue addressable devices

Fire detection equipment

Premier M Plus & Infinity 8

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

PROTEC CIRRUS HYBRID ASPIRATING SMOKE DETECTION SYSTEMS

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

welcome to our world fire alarm systems - series 600

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

conventional system operation

Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Conventional Fire Detection and Extinguishant Control System Specification

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

SECTION DETECTION AND ALARM

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

Triple Waveband Infra-Red Flame Detection

The supplier and installer of the system should be approved by the local civil defence authority.

Fire Detection Product Range

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

Standard the the Raising

HART HSSD High Sensitivity Smoke Detection

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Fire Alarm system Installation Guide

BS5839 Part 1:2002 Overview

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Software Release For DF6000/CF3000/FX6000. Site Installer Network Card

D200+ Auto-Dialler Installation/Operators Manual

GST301. (Single Protection Zone) Operation Manual

DTW Works Master Specification Version 2006

Advanced Intelligent Modules. Overview. Description

Always on the Lookout Perfect Protection against Burglary

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

OPAL TM Detector range

Product Information Fire alarm panel 8000 C

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Overview of Fire Alarm Systems and Maintenance

ACTIVE 5 ENGINEERING MANUAL

TS510 & TS500. Installation & User Guide. Compatible Equipment

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CB Zone Conventional Control Panel

Global System Technology(UK) PLC The Intelligent Solution

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

3. MOUNTING THE FIRE ALARM PANEL PLANNING CABLE ENTRY 3.2 FIXING THE BACKBOX TO THE WALL

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Emergency voice communications Product Name

Addressable Fire Alarm Systems

AlarmSense 2-wire detection and alarm system. Product Guide

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

How To Use A Ds340 (Dsp)

4 Loop Analogue Addressable Control Panels

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

I.S :2013 Fire Detection & Alarm Systems

GSM Alarm System User Manual

TMS TANK MANAGEMENT SYSTEM

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

2.24. Pump Controller 704. Data Sheet

500r+ Installation and User Guide

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

ALARMLINE ANALOGUE Linear Heat Detection System

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

FIRERAY 2000 Installation Guide

JUNIOR V3. Fire Alarm Control Panel INSTALLATION & COMMISSIONING MANUAL GLOBAL REVISION 2.3 FIRE EQUIPMENT QUEUE REVIEW STATUS ZONES

Remote Monitoring and REC 501 Control Unit Product Guide

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Drayton Digistat +2RF/+3RF

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Thyristor-controlled power supplies and battery chargers

QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2

9452/9453 Installation and User Guide

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

Consultant s Guide for Fire Detection & Alarm Systems for Buildings

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual. Man-1055 Issue 21 September 2010

Fire Detection Systems

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

PLAN REVIEW GUIDE FOR FIRE ALARM

Temperature & Humidity SMS Alert Controller

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Hand-held thermometer Model CTH7000

Transcription:

Protec Protec Algo-Tec TM 6300 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE

CAUTION Protec Protec Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM The Protec Algo-Tec 6300 Interactive Digital Addressable System unwrapped: The Protec Algo-Tec TM 6000 protocol developed by Protec s in-house Research and Development team is utilised by the Protec Algo-Tec TM 6300 interactive digital addressable fire control systems. Immunity to false alarms, more responsive fire detection, and ease of use has all been achieved to develop one of the most reliable systems available. Protec Algo-Tec 6300 The name Algo-Tec TM is a derivative of Protec algorithms. Algorithms are logical mathematical procedures for solving problems. Protec have developed fire detection algorithms coupled with fuzzy logic specifically designed to reduce unwanted fire alarms and to enhance the sensitivity of the system to true fire phenomenon. The Algo-Tec TM algorithms are exclusively utilised by the Protec Algo-Tec TM 6400 and 6300 Interactive Digital Addressable Fire Control Systems. Interactive Algo-Tec TM evaluates the data of each fire sensor and is able to learn from the information received. This may simply be to recognise that a sensor is becoming contaminated or in a dirty environment and to automatically increase the alarm threshold to compensate for the background levels (Threshold Compensation). More complex Algo-Tec TM functions include the ability to discriminate between certain fire and non-fire conditions, filtering out certain environmental stimuli, and increasing the sensitivity of a sensor when an increase in temperature is detected. The net effect of the interaction between the sensors and the Algo-Tec TM decision making is enhanced performance, through immunity to false alarms and more responsive fire detection. Digital Addressable The data communication between the sensors and the control equipment is Digital. The Algo-Tec TM protocol utilised by the 6000 system enables high levels of data to be transferred, providing far more detailed information than was previously achievable with analogue addressable systems. It should however be noted that many analogue addressable systems use digital communication but do not transfer the high levels of data associated with the Algo-Tec TM protocol. Speed, stability, excellent EMC and security all serve to enhance the Algo-Tec TM Digital signalling. Why go analogue addressable when you can now choose Algo-Tec TM Digital Addressable. Algo-Tec 6000PLUS Interactive Decision Making Algorithms - Typical Applications Office Mode (High Performance) Computer Fire Day/Night Mode Offices DISCRIMINATING ALGORITHM Cigarette Smoke Day Mode: Office mode (high performance) Offices Night Mode: Clean mode (Extra high performance) Bin Fire Factory Loading Bay Clean Mode (Extra High Performance) Printer Paper Fire Day Mode: Heat detection only (6000PLUS/OPHT) Factory Loading Bay Night Mode: Smoke & Heat detection Bedroom Mode Computer Room Fire Chemical Fire DISCRIMINATING ALGORITHM Steam From Bathroom DISCRIMINATING ALGORITHM Aerosols in Bedroom Smoldering Fire NOTE: The above examples give an indication of system reaction to intermittent contaminants and typical fire sources in a correctly designed BS5839 system. They by no means detail the full complexity of the systems decision making algorithms. Examples are for 6000PLUS/OPHT. A D D R E S S I N G S A F E T Y S Y S T

Total Loop Load in Alarm (ma) Guide to loop cable conductor sizing for the Protec 6300 system. 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Loop Length (Metres) 500 550 600 650 700 750 800 850 900 950 1000 6000/MCP FAST TM Addressable Manual Call Point - Key operated test facility, a loop short circuit isolator is incorporated. 6000PLUS/UG4DP Ventilation Duct Smoke Sensor Assembly - Single pipe air sampling unit for air speeds from 0.5 to 20m per sec. supplied with 6000PLUS/ BASE suitable for use with 6000PLUS/OP FAST TM interactive optical smoke sensor. 6000/FIREBEAM FAST TM Addressable Loop Powered Beam Detector - Combined transmitter/receiver unit and separate low level controller. With a beam range of 5-100 metres. 6000/SSR FAST TM Addressable Loop Powered High Output Electronic Sounder - utilises a Piezo driver unit to enable high sound output and very low current consumption. Total Loop Load in Alarm (ma) 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Loop Length (Metres) 1050 1100 1150 1200 1250 1300 1350 1400 1450 1500 Table detailing the loop standby and alarm load for typical Algo-tec 6000 devices. The conductor size required as follows: 1.0mm 2 1.5mm 2 2.5mm 2 MAXIMUM LOOP RESISTANCE 16 OHMS PER CONDUCTOR Product Description No of Addresses Note: The following Loop Parameters should be observed 1) The total number of addressable devices should not exceed 191 per loop. 2) Add 20mA to total loop alarm load to allow for fire indicator LED s on devices 3) The total loop alarm load should not exceed 600mA per loop. Loop Standby Load ma Loop Alarm Load ma 6000/MCP Manual Call Point 1 0.45 0.85 6000/FIREBEAM Loop Beam 1 3.65 7 6000PLUS/HT Heat Sensor 1 0.2 0.2 6000PLUS/HT/S Heat Sensor c/w Sounder 1 0.4 5.4 6000PLUS/OPHT Optical Smoke and Heat Sensor 1 0.2 0.2 6000PLUS/OPHT/S 6000PLUS/OPHT/SVAD 6000PLUS/OPHT/TSVAD Optical Smoke and Heat Sensor c/w Sounder Optical Smoke and Heat Sensor c/w Sounder and Visual Alarm Device Optical Smoke and Heat Sensor c/w Talking Sounder and Visual Alarm Device 1 0.4 5.4 1 0.55 24 1 0.55 25 6000PLUS/OPHTCO Optical Smoke, Heat, and CO Sensor 1 0.45 0.45 6000PLUS/OPHTCO/S Optical Smoke, Heat, and CO Sensor c/w Sounder 1 0.45 5.45 6000/VAD/W Loop Visual Alarm Device 1 0.8 19 6000/SSR Loop Sounder 1 0.7 5 6000/SSR/VAD Loop Sounder Visual Alarm Device 1 0.7 24 6000/LCM Local Control Module 1 0.7 5 6000/MICCO Monitored Input CC Output 1 0.55 5 6000/VAD/W/RED FAST TM Addressable Loop Powered High Intensity VAD - Approved to EN54-23 the wall mounted VAD has a unique lens that distributes the white light in a cuboid pattern to achieve 7.5m x 7.5m coverage @ 2.4m high. 6000/VAD/C/RED FAST TM Addressable Loop Powered High Intensity VAD - Approved to EN54-23 the ceiling mounted VAD has a unique lens that distributes the white light in a cylindrical pattern to achieve 7.5m dia coverage @ 3m high. 6000/SSR/VAD 6000PLUS/TSR2 6000/FIU Flush Mounted Short Circuit Isolator Unit - To isolate a short circuit fault on either the incoming or outgoing loop cables. Suitable for a 30mm deep electrical mounting box. 6000/LPZA FAST TM Addressable Flush Mounted Loop Powered Zone Alarm Interface Unit - With a monitored detection circuit suitable for use with Protec 3000 series detection devices. Line continuity maintained. Monitored alarm output circuit rated at 24Vdc 50mA max. Suitable for a 45mm deep electrical mounting box. A loop short circuit isolator is included. 6000/LCM FAST TM Addressable Loop Powered High Output Electronic Sounder with VAD - Approved to EN54-3, 17 & 23 the wall mounted combined sounder/vad has a sound output of 100dB(A) @ 1m plus VAD light output of 7m x 7m coverage @ 2.4m high. FAST TM Addressable Loop Powered Talking Sounder - The 6000PLUS/TSR2 voice enhanced talking sounder is available with seven voice messages plus bell sound in addition to the three fire alarm tones compatible with the Protec range of electronic sounders. FAST TM Addressable Flush Mounted Local Control Module - Allows easy integration of Protec addressable fire detection systems into houses of multiple occupany and offers novel features to reduce false alarms. The interface drives a zone of 3000 series detection devices and provides a supply to a local alarm circuit. 6000/MICCO FAST TM Addressable Flush Mounted Loop Powered Monitored Input, Clean Contact Output Interface Unit - With a monitored input circuit suitable for use with simple switch devices and the output is a clean changeover contact 5amp rated at 240V ac. A link can be cut to provide a 7-second delay to the input. Suitable for a 45mm deep electrical mounting box. A loop short circuit isolator is incorporated. Multi-way Input/Output Interfaces - A range of 16 way input/ output interfaces are available with monitored alarm outputs or clean changeover contacts. All interfaces are FAST TM addressable. E M S W I T H I N T E L L I G E N C E

Protec Protec Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM CONTROLS & DISPLAYS System Features The Protec Algo-Tec TM 6300 is an interactive digital addressable fire detection and alarm system ideally suited for small, medium & large sized buildings such as nursing homes, hotels and offices. The control panel is designed and manufactured by Protec to comply with EN 54-2 & 4. The control panel is available as surface or recessed mounted with a moulded polycarbonate hinged door finished in storm grey, or optionally with polished solid brass or brushed stainless steel finish for recess mounting only. Secure Network Up to 32 Algo-Tec TM 6300 control and repeat panels and illuminated zonal mimics can be interconnected using the optional add in 6300 network card. Wired as a loop the networks dual channel fault tolerant RS485 ensures that no single fault can disable the system. In the event of multiple faults, each panel will function independently. The network can be wired using copper or fibre optic cables. Non Networked Stand Alone System For small single panel systems, the serial communication link can be utilised to signal, up to 4 repeat panels using a 4 core screened cable. A network card is not required. Loops Each 6300 control panel is equipped with 1, 2 or 4 high capacity Algo-Tec TM digital addressable data loops, with up to 191 address capacity per loop. Total panel devices is restricted to 512 inputs to comply with EN54 part 2. In addition to sensors, interfaces and manual call points the loop can also support loop powered SOUNDERS, VISUAL DEVICES and OPTICAL BEAM DETECTORS. Loop powered sounder bases adopt the sensor address to increase the capacity of the loops still further, resulting in reduced cabling requirements, simplified installation and associated cost savings. Alarms In addition to loop powered sounders and Visual Alarm Devices (VAD s), 4 programmable fully monitored alarm outputs are provided at the panel for alternative wiring arrangements. Auxiliary Contacts One set of double pole changeover contacts, which are programmable. 6300 Loop LCD Display Zoned Mimic Panel 6300 Loop Powered LCD Repeat Display The 6300/LOOP/LCD can be connected directly to the local Algo-Tec TM digital addressable data loop and takes up just one address. The facia displays power, fire, fault, disablement and more alarms. Fire and fault events are displayed on the 2x40 character LCD display and automatically scroll. A backlight ensures that the events can be read in all lighting situations. Fire events have highest priority and inhibit the display of fault events. A new event initiates the internal buzzer and a mute button allows the internal buzzer to be muted. Loop standby/alarm load 60mA. 6300 Illuminated Zonal Mimic The Protec 6300 customised, illuminated zonal mimic can be connected to the 6300 control panel in the same way as the 6300 repeat panel. The Illuminated mimic is housed in a matching enclosure to the control and repeat panels. The fascia is manufactured from Kemco finished in anodised aluminium effect and can be engraved to our clients scaled drawing typically detailing the building outline and zonal areas and has a viewing area of 360(W)mm x 340(H)mm. Up to 32 LED s can be placed on the fascia and will be illuminated by the appropriate zone activation. The illuminated mimic is available as surface or recessed mounted with a hinged door finished in storm grey, or optionally with a polished solid brass or brushed stainless steel finish recess mounting enclosure and an engraved Kemco fascia in anodised aluminium or brushed brass effect finish. A D D R E S S I N G S A F E T Y S Y S T

Controls and Display All the functions of the Control Panel are accessed via a modern styled hinged lockable door, moulded from polycarbonate with a clear display viewing window. When opened the door reveals the panel controls and easy to follow operating instructions. These controls are SILENCE, SOUND S, RESET and ACCEPT plus a MENU push button to enable access to the user menu facilities. The control panel display consists of an 80 large character liquid crystal display, twin common fire LED indicators, 32 separate zonal fire LED s, power on, pre-alarm, system fault, common fault, test and disablement LED s. An optional integral low noise thermal printer is also available. Liquid Crystal Display The 80, large character liquid crystal display will under normal quiescent conditions display the current date and time with the option to also display a 40-character user s message such as site name. In an alarm or fault condition the LCD will display the device loop, address and zone number and up to 40 characters of user definable location text, programmable on site using Protec 6300/WINTEXT windows based software. Device Location Text Windows based text software is supplied free of charge to our clients to enable you to enter the location text on to the disk supplied and hand to our commissioning engineer for loading into the panel during commissioning. This simple process allows you more flexibility enabling you to make any last minute changes & speed up the entire process. Repeat Panel 6300 Hercules Colour Graphics System Printer The integral printer is a 40-character low noise thermal printer. In operation the printer will provide on demand real time data of fire and fault conditions including time and date of events along with the device number and location text. By accessing the appropriate function from the user menu facility a variety of reports can be printed including the previous 100 incidents from the event log, the system devices configuration and programming matrix, devices which are becoming due for cleaning and the current status of all devices. 6300 Repeat Panel The Protec 6300 repeat panel can be connected to the 6300 control panel s serial communications link connection, using a 4-core screened cable. If the 6300 secure network is utilised then the repeat panel should be connected to the secure network by adding the integral 6300 network card. The repeat panel has an identical display to the control panel including 80 character LCD and 32 zone fire LED s. Full control of silence, accept, sound alarms and reset is included and can be disabled. The repeat panel is available as surface or recessed mounted with a moulded polycarbonate hinged door finished in storm grey, or optionally with polished solid brass or brushed stainless steel finish for recess mounting only. 6300 Hercules Colour Graphics System The Protec Colour Graphics System is a Windows based PC package providing a graphical representation of large sites enabling the precise location of an incident to be readily identified enabling a prompt response. Using touch screen or mouse, the operator can track an incident and zoom from a site plan to intermediate plan listing floor levels, then zoom to a specific floor plan and if necessary then zoom to a specific detailed area within the floor plan showing the device in question. Colour prints of the maps can be printed automatically or on demand. Power Supply The 6301, 6302 and 6304 control panels can be supplied with an integral 3A dc switch mode charger and a 24V 10Ah sealed lead acid battery. The system is also available, suitable for use with Protec 9000/BC range remote power supplies with an extensive range of battery and charger sizes. On Site Programming The Protec Algo-Tec 6300 system is on site programmable. All of the commissioning configuration data can be entered and/or backed up using the Protec 6300/WINPROG windows based programming software via a PC. This feature enables the system to be re-configured and checked prior to attending site simplifying commissioning works on site, enabling text amendments to be carried out whilst on site and providing an invaluable remote backup should the need arise. The system configuration data can also be printed using the control panels optional in-built thermal printer. E M S W I T H I N T E L L I G E N C E

Protec Protec Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM Loop Devices The Protec Algo-Tec 6000PLUS protocol utilises FAST addressing (Firmware Addressed Secure Technology). Every FAST device is manufactured with a unique serial number. FAST addressing ELIMINATES troublesome and time consuming address cards and DIL switching whilst being far more secure than soft addressing. The Protec Algo-Tec 6000PLUS sensor range has been developed to incorporate advanced fire sensing technology, electronic sounders, high intensity visual alarm and speech enhanced talking sounder capability, all integrated within the sensor head and powered from the loop. Typical Sensor Variants 6000PLUS/OPHT/S = c/w Sounder 6000PLUS/OPHT/VAD = c/w Visual Alarm Device 6000PLUS/OPHT/S VAD = c/w Sounder and Visual Alarm Device 6000PLUS/OPHT/TS = c/w Talking Sounder 6000PLUS/OPHT/TS VAD = c/w Talking Sounder and Visual Alarm Device 6000PLUS/HT FAST TM Interactive Heat Sensor - Interactive addressable heat sensor with low thermal mass thermistor, giving fast response to temperature increases. Other Heat Sensor variants include: 6000PLUS/HT/S, 6000PLUS/HT/SVAD 6000PLUS/HT/TSVAD 6000PLUS/OP FAST TM Interactive Optical Smoke Sensor - Interactive addressable high performance optical smoke sensor provide efficient reliable detection using the light scatter sensing principle with rapid response to a fire signal. Other Optical Sensor variants include: 6000PLUS/OP/S 6000PLUS/OPHT FAST TM Interactive Optical Heat Sensor - Interactive addressable high performance optical smoke and heat multi-sensor. Other Optical Heat Sensor variants include: 6000PLUS/OPHT/S, 6000PLUS/OPHT/VAD, 6000PLUS/OPHT/SVAD, 6000PLUS/OPHT/TS, 6000PLUS/OPHT/TSVAD 6000PLUS/OPHTCO FAST TM Interactive Optical Heat CO Sensor - Interactive addressable high performance optical smoke heat and carbon monoxide multi-sensor. Other Optical Heat Sensor variants include: 6000PLUS/OPHTCO/S, 6000PLUS/OPHTCO/L, 6000PLUS/OPHTCO/SL, 6000PLUS/OPHTCO/TSL 6000PLUS/BASE Low Profile Common Mounting Base - Compatible with the above range of Algo-Tec TM 6000PLUS Sensors. Plant shutdown interface 6000/MICCO Heavy duty plant shutdown signal (Rated at 240V 5A) Zone circuit Single 2 wire loop cable Optional RS232 port: Hercules colour graphics pager or BMS interface KEY: LOOP 1 LOOP 2 EOL EOL Alarm circuit 6000/LPZA Loop powered zone alarm interface 4 Core serial communications link (up to 4 Repeaters) 6300 Serial Communication Link 6300 Loop repeater Sprinkler delay interface 6000/MICCO Zone circuit 6000/LCM Local Control Module Supply EOL 2 Core RS485 Network using 6300 Netcard in each panel/repeater (up to 32 panels) 6300 Secure Network Option 1 OR Option 2 } EOL 4 Programmable monitored alarm outputs Monitored fire station output } 2 Auxiliary fire C/O contacts Fault C/O contacts 24V Aux. Output Plant shutdown output (Rated at 240V 5A) Alarm circuit Bomb alert/class change input NOTE: The Serial Communication Link cannot be used if the secure network (option 2) is chosen. Heat Sensor Local Control Module Monitored Input CC Output Interface Optical Smoke and Heat Sensor Electronic Sounder 6000PLUS/FFBASE Fast Fixed Base - Fast fixed recessed base is designed to recess the sensor into a false ceiling to give a lower profile view of the sensor. Optical Smoke, Heat and CO Sensor Duct Probe Unit c/w Smoke Sensor Electronic Sounder VAD Visual Alarm Device (VAD) 6400/LOOP/LCD Repeater - Connected directly to the local data loop and takes up just one address. The 2 x 40 character LCD Display provides clear text location of fire and fault events. Manual Call Point Beam Detector Loop Powered Zone Alarm Interface 6300 Loop LCD Display 6300 Zonel Mimic 6300 Repeat Panel A D D R E S S I N G S A F E T Y S Y S T

Typical 6300 Network System FEATURES & BENEFITS Cost Effective - High specification interactive digital addressable fire detection and alarm system, providing a cost effective solution for small, medium and large sized buildings and sites. Design Flexibility - Up to 32 control panels, repeats and illuminated zonal mimics can be networked enabling system design and expansion to be easily achieved to suit the site for economic wiring and operational convenience. Secure Network - Wired as a loop, the network s dual channel RS485 link ensures that no single fault will affect the system. BUILDING 3 BUILDING 4 Up to 32 panels on a network Easy to Install - An extensive range comprising Loop Powered Alarm Sounders, Visual Alarm Devices, Interfaces, Manual Call Points and Sensors can all be connected to the nearest control panel using a single 2-core cable for each of the high capacity Loops (up to 4), accommodating up to 191 devices per Loop, 512 maximum per panel. Reduced False Alarms - The Protec Algo-Tec TM 6000 interactive fire sensors utilise advanced discriminating algorithms for maximum reliability and immunity to false alarms. BUILDING 2 BUILDING 5A Enhanced Performance - The Protec Algo-Tec TM 6000 sensors learn from their environment, applying interactive decision making algorithms to provide stability, threshold compensation and optimised performance. 2 Core RS485 Secure Network Secure Detection Loops - Many Protec Algo-Tec TM 6000 devices incorporate built-in short circuit isolator units. These can be located as required. BUILDING 1 BUILDING 5B Easy to Address - FAST addressing (Firmware Addressed Secure Technology) ELIMINATES troublesome and time consuming setting of address cards and DIL switches. Devices Display Address Number - RVAV Remote Visual Address Verification. Confirmation of the correct location of each device can be easily identified, using the devices in-built LED to indicate the device address number. Colour Graphics System 24V dc From Panel or P.S.U. On Site Flexibility - Configuration of all system functions is fully site programmable. Reduced Maintenance Costs - Early indication and reporting of sensors approaching contamination level reduce false alarms and enable dirty sensors to be cleaned or replaced. Optional RS232 Port - Typically used to connect to a colour graphics system, pager system or BMS interface. Allows PC connection for backup and programming. Designed to EN 54-2 & 4 E M S W I T H I N T E L L I G E N C E

Technical Specification 6300 Control Panel Complies with EN 54-2 & 4 Models:- 6301 - Single Loop Panel 6302-2 Loop Panel 6304-4 Loop Panel Specification:- Power Supply Mains nominal ± 10%. Working Voltage 21.5-30V dc. Temperature Range 0-40 C. Maximum Humidity 85% Non-condensing. Panel Model 6301 6302 6304 Standby Load (Mains Fail Condition) 90mA 115mA 170mA Alarm Load (Mains Fail Condition) 210mA 260mA 345mA MANAGEMENT SYSTEMS LPCB ref. no. 201ad Display Backlit liquid crystal display 2 lines of 40 characters. Digital Addressable Loops 1,2 or 4 loops, each with 191 address capacity. Total panel capacity is restricted to 512 Input addresses to comply with EN 54-2. Algo-Tec 6000 Protocol. Total Loop Load 600mA per loop including all loop connected devices. Zones 32 Zone LED s plus twin red common fire indicators. Integral Charger 3A dc Switch-mode. Integral Battery 10Ah 24V sealed lead acid. Remote Power Supply The Protec 9000/BC range of power supplies are compatible with the 6300 panels. Dual path outputs and fault signalling, (4 wire plus 2 wire, 2 primary power, 2 signals, 2 secondary power). Programmable Alarm Outputs 4 Monitored - Internal sounder circuits (1A rated @ 24V). 1 Set of non-monitored double-pole changeover contacts (1A rated @ 24V). Up to 191 alarm outputs per loop with the use of additional loop O/P devices. Alarm Load Maximum 3A with integral power supply unit. Fault Monitoring Fully fault monitored to EN 54-2. Fault Output Single pole changeover contacts (1A rated @ 24V). Serial Communications Interface 4 wire (2 power, 2 data) for up to 4 repeat/mimic panels. Secure Network To replace above serial interface when optional 6300 network card fitted to allow up to 32 panels / repeaters to be securely networked (2 wire loop). Auxiliary Output Supply 24V dc fused at 250mA. Common Fire Output (fire station) 24V dc fully monitored output rated at 20mA. 1K EOL. Common Fault Output (fire station) 24V dc fully monitored output rated at 20mA. 1K EOL. RS232 Communications Interface 9 way D type connector (Male). For program/text software upload/download. Optional Integral Printer 40 character low noise thermal printer. Dimensions (mm) 440(W) x 385(H) x 144(D). Approvals (6301) LPCB Certificate No: 201ad/07, EC Certificate No: 0832-CPD-1474, Relevant Standard: EN 54-2 & 4. (6302) LPCB Certificate No: 201ad/08, EC Certificate No: 0832-CPD-1475, Relevant Standard: EN 54-2 & 4. (6304) LPCB Certificate No: 201ad/09, EC Certificate No: 0832-CPD-1476, Relevant Standard: EN 54-2 & 4. Programmability 96 Input Groups System Wide First 32 have an independent programmable time-out delay. 96 Output Groups per Panel First 32 have an independent programmable delay for first 32 input groups. Each is programmable as an alarm or control output. 32 Zonal Output Groups per Panel Each is activated by a separate zone input for zones 1 to 32. Programmable master time-out. Selectable coincidence detection. 24 programmable Non-latching addresses. 24 programmable Non-latching Fire addresses. 6300 Repeat Panel/ 6300 Illuminated Zonal Mimic Power Supply Standby Load Alarm Load Serial Communications Link Secure Network Dimensions (mm) 24V dc from local power supply or internal charger and battery ( required). 50mA. 50mA. 4 wire (2 power, 2 data) for up to 4 repeat/mimic panels. To replace above serial interface when optional 6300 network card fitted to allow up to 32 panels/repeats to be securely networked (2 wire loop). 440(W) x 385(H) x 144(W). 6300 Netcard Optional network card fitted to each control panel and repeat to be networked. The network card replaces the serial communication link. Up to 32 panels/repeats can be securely networked (2 wire loop). Standby/Alarm Load 70mA per network card. Protec 2010-2016 Protec: Scotland Tel: 0845 456 5390 Fax: 0845 456 5391 Protec: North East Tel: 0845 456 5396 Fax: 0845 456 5397 Protec: Yorkshire Tel: 0845 456 5388 Fax: 0845 456 5389 Protec: Midlands Tel: 0845 456 5398 Fax: 0845 456 5399 Protec: South East Tel: 0845 456 5394 Fax: 0845 456 5395 Protec: South West Tel: 0845 456 5392 Fax: 0845 456 5393 Company Policy is one of continuous improvement, we reserve the right to change specification without prior notice Protec Fire Detection Plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT Tel: 01282 717171 Fax: 01282 717273 Web: www.protec.co.uk Email: sales@protec.co.uk MED1509 Issue 4 N 92-048-61C