CLEAR COLLECTION FOR CLEAR ALIGNERS CLEAR SOLUTIONS FOR CUSTOMIZED EFFICIENCY



Similar documents
Clear Collection instruments for clear aligner. Innovation is taking two things that already exist and putting them together in a new way.

Molar Uprighting Dr. Margherita Santoro Division of Orthodontics School of Dental and Oral surgery. Consequences of tooth loss.

BASIC ORTHODONTICS. And why we believe in THE TIP EDGE TECHNIQUE (Differential Straight Arch)

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

Implants in your Laboratory: Abutment Design

Use of variable torque brackets to enhance treatment outcomes

Table of Contents Section 6 Table of Contents

Removable Partial Dentures 101 Back to the Basics. Luther A. Ison, CDT University of Minnesota School of Dentistry

Orthodontic mini-implants, or temporary anchorage devices

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Universal Crown and Bridge Preparation

The Lower Free End Saddle (distal extension saddle)

CLASSIFICATION OF CARIOUS LESIONS AND TOOTH PREPARATION.

Denture Trouble Shooting Guide

CLASSIFICATION OF REMOVABLE PARTIAL DENTURES

TAD Clinical Reference Guide

Classification of Malocclusion

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

Introduction to Charting. Tooth Surfaces: M = mesial D = distal O = Occlusal B = buccal F = facial I = incisal L = lingual

Healing Abutment Selection. Perio Implant Part I. Implant Surface Characteristics. Single Tooth Restorations. Credit and Thanks for Lecture Material

The American Board of Orthodontics (ABO) Digital Model Requirements Original Release Last Update

porcelain fused to metal crown

Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6

Headgear Appliances. Dentofacial Orthopedics and Orthodontics. A Common Misconception. What is Headgear? Ideal Orthodontic Treatment Sequence

Introduction to Dental Anatomy

PREPARATION OF MOUTH FOR REMOVABLE PARTIAL DENTURES Dr. Mazen kanout

stone model bonding tray improve the accuracy

Page 1 of 10 BDS FINAL PROFESSIONAL EXAMINATION 2007 Prosthodontics (MCQs) Model Paper SECTION I

In Class IV arch: Fulcrum line passes through two abutments adjacent to single edentulous space.

Technically Beautiful TM

2 Single Use Only. Guidance System Manual. Part Art. Part Science. All Orthodontics.

Principles of Partial Denture Design

General Explanation of the Straight Wire Appliance in the Treatment of Young People and Adults Publication for the Journal du Dentiste in Belgium

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

Full Crown Module: Learner Level 1

Prosthodontist s Perspective

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

CLASS II AMALGAM. Design Principles

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Ando A., Nakamura Y., Kanbara R., Kumano H., Miyata T., Masuda T., Ohno Y. and Tanaka Y.

In the past decade, there has been a remarkable

How to Achieve Shade Harmony With Different Restorations

Full Crown Module: Learner Level 3

Removable Partial Denture Manual. Robert W. Loney, DMD, MS 2011

ABSTRACT INTRODUCTION. Facial Esthetics. Dental Esthetics

3.60 CEREC CONNECT INTERNET PORTAL EXPORT

MEDICAID DENTAL PROGRAMS CODING, POLICY AND RELATED FEE REVISION INFORMATION

Nobel Clinician - Quick Guide

DENTAL ADVANTAGE HELPFUL HINTS FOR THE RDA PRACTICAL EXAM

Attachments And Their Use In Removable Partial Denture Fabrication

Dr. Park's Publications

Microimplant Anchorage in Orthodontics

IMPRESSION TECHNIQUE AND MATERIALS

There When You Need Them: 10 Principles of Successful RPD Treatment

Universal Screw Removal System (USR)

Introduction of Removable Partial Denture - Design and Retention

The Dahl principle in everyday dentistry

Cross-sectional. Translate Lp3 after. Translate Lp3 after. Tipping Up3 after. ext Up2. ext Lp2. ext Lp2. Bur buc-ling with flap

Seminar 10 expectations

DEVELOPMENT AND GROWTH OF THE MANDIBLE

Angulation Torque Distal Offset Width Headgear Right/Left On Bases On Bands On Bases On Bands

portion of the tooth such as 3/4 Crown, 7/8Crown.

Boston College, BS in Biology University of Southern California, Doctor of Dental Surgery, DDS, 1990.

POWER SCALING AIR-FLOW AIR POLISHING SOLUTIONS

Removable appliances II. Functional jaw orthopedics

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

Treatment planning for the class 0, 1A, 1B dental arches

Topics for the Orthodontics Board Exam

Relative position of gingival zenith in maxillary anterior teeth- a clinical appraisal

Periodontal Consideration Before and After Orthodontic Treatment Tsung-Ju Hsieh, D.D.S., M.S.D.

A BIOMETRIC APPROACH TO PREDICTABLE TREATMENT OF CLINICAL CROWN DISCREPANCIES

Hu-Friedy PERMA SHARP SUTUREs

The Successful Crown Delivery

Periodontal surgery report for crown lengthening of tooth number 24,25

Unless a prosthetic replacement is inserted soon

ball abutment overdenture: chairside pick-up using existing denture

Basic Training 101 TRAINING FOR THE CLINICAL TEAM WITH CONCENTRATION ON COMMUNICATION SKILLS AND CLINICAL SYSTEMS. By: Charlene White, President

Dental Bridges. What are they? What are the parts of a typical dental bridge (fixed)? When are dental bridges needed?

Fast and Predictable Tooth Extraction Technique

screw-retained crown using a PEEK temporary abutment

HermanMiller Aeron Posturefit Installation AE905A AE905B AE905C

Orthodontic treatment of gummy smile by using mini-implants (Part I): Treatment of vertical growth of upper anterior dentoalveolar complex

Zirconium Abutments for Improved Esthetics in Anterior Restorations

SYSTEMATIC APPROACH TO ORTHODONTIC DIAGNOSIS DENT 656

POLICY HOLDER/SUBSCRIBER INFORMATION

Implant Abutments and Crowns on your CEREC. Welcome

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Dell E Series Monitor VESA Mounting Bracket Installation Instructions

The Attractive Glass Abutment System (ZX-27) HANDOUT

prosthetic technique manual

In the Spring of 2010, the American Academy of Cosmetic

Removing fixed prostheses using the ATD automatic crown and bridge remover

Three-Dimensional Analysis Using Finite Element Method of Anterior Teeth Inclination and Center of Resistance Location

In 1999, more than 1 million people in

2016 Buy Up Dental Care Plan Procedure List

your talent. our technology. the perfect fit.

Transcription:

CLEAR COLLECTION FOR CLEAR ALIGNERS CLEAR SOLUTIONS FOR CUSTOMIZED EFFICIENCY

Hu-Friedy s CLEAR COLLECTION Hu-Friedy s Clear Collection consists of innovative instruments designed to accent, individualize and optimize the biomechanics of the invisible aligner experience with no heat required. THE TEAR DROP 678-800 An instrument created to add a notch at the gingival margin of clear aligners anywhere elastic hooks are required within the arch. The Tear Drop provides a reservoir to hold the elastics in place as the aligner is seated. This permits easier manipulation of elastics by the patient. The Tear Drop elastic hooks can be used in tandem with bonded attachments to direct eruption of teeth into aligners. The Tear Drop is positioned at an angle to the force that will be applied to the clear aligner by the elastics and the depth of the reservoir cut can be adjusted to need. The Tear Drop elastic hook can be used to hook-up elastics of all types from Class II, Class III, Delta, Class I intraarch, for connection to TADS, and to produce extrusive forces for specific teeth.

THE HOLE PUNCH 678-803 The Hole Punch is used to create half-moon cutouts for relief of clear aligners around bonded buttons used for elastics. No need to attempt to attach buttons to plastic trays. In addition, the Hole Punch can nip away plastic to provide soft tissue clearance to prevent aligner impingement of tissue. The Hole Punch can also be used to relieve marginal plastic impingement or irritation of soft tissue anywhere along the aligners such as the incisive papilla. The Hole Punch is positioned at the gingival margin with one-half of the circle of the punch over the plastic of the aligner. The half moon cutout can be placed on any tooth where bonded buttons or brackets are added for elastics or other biomechanics.

THE VERTICAL 678-801 Correcting rotations is often a challenge with aligners. The Vertical emphasizes overcorrection of rotations by producing an indentation at the mesial or distal line angles on the facial and/or lingual of a specific tooth. As an option, a rotational couple can also be created using vertical indents on facial and lingual surfaces on opposing sides of a tooth. The Vertical can also be used to produce an indent to produce a mild nudge to enhance resolution of in-and-out discrepancies. Impress an indentation with The Vertical along the mesial or distal line angle of a tooth to enhance rotational control.

THE HORIZONTAL AFTER 678-802 The Horizontal instrument produces an indentation to accent individual root torque. It also serves a second purpose by enhancing retention of either clear aligners or retainers by placing an indent into a tooth s undercut or below a bonded attachment. WHITE Accent individual root torque by producing an indent at the gingival margin on either the buccal or lingual for any tooth in the arch form. Increase clear aligner or retainer retentiveness by producing a horizontal indent into the undercut of specific teeth or just under an attachment.

Hu-Friedy s Clear Collection was designed by S. Jay Bowman, DMD MSD. Jay is a Diplomate of the American Board of Orthodontics, a member of the Edward H. Angle Society of Orthodontics, and on faculty of four universities. He has published numerous articles and book chapters, developed several orthodontic inventions, and provided lectures on orthodontics around the world. Jay has maintained a clinical practice in Kalamazoo/Portage, Michigan for over 28 years. CLEAR COLLECTION FOR CLEAR ALIGNERS The Tear Drop 678-800 The Vertical 678-801 The Hoizontal 678-802 The Hole Punch 678-803 INSTRUMENT MANAGEMENT For more information about Hu-Friedy s Total Solutions visit HU-FRIEDY.COM Hu-Friedy Mfg. Co., LLC: 3232 N. Rockwell St. Chicago, IL 60618 U.S.A. Telephone: 1-800-Hu-Friedy (1-773-975-6100) Website: Hu-Friedy.com 2015 Hu-Friedy Mfg. Co., LLC. All rights reserved. HFO-2713/1115