Oil Sight Glass BENEFITS

Similar documents
08.08 Vic-Check Valves

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

introduction to constant level lubrication

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing?

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

NITROUS TRANSFER PUMP INSTRUCTIONS

Select Radiators Installation Guide

PRESSURE REDUCING CONTROL VALVE

V47 Series Temperature Actuated Modulating Water Valves

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

World-Class Oil Sampling It is Possible

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

2010 Residential Water Heater Replacement Check List

Wastewater Capital Projects Management Standard Construction Specification

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Trouble shooting guide

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Watts Pure Water Systems

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

FRL/AirCare Air Controls & Accessories

RUBBER SLEEVE KNIFE GATE VALVE

MUELLER FALLING FILM CHILLERS

CHEMICAL CLEANING UNIT Product number:

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

AIR LINE VALVES AND GAUGES

Diesel Fuel Systems. Injection Nozzles

Float and Thermostatic Traps Series H, C and X

Installation Instructions

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Complete Systems & Parts Automatic Oiler & Grease Bank

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

World Leader in Emergency Eye Care

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

SunMor SM-V30 Solar Water Heater Installation Manual

45 URAI DSL Roots. Quick Specs. Also Available in: Part Number T

Flushing and Cleaning the A/C System

Tube Type Oil Skimmer Comparison

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

Hose Clamps & Fittings

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

What to Expect From the Examination. How to Study the Plumbing Codes

GS-General Service Control Valves

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

HIGH PERFORMANCE FILTERS AND ELEMENTS

PNEUMATIC - HIGH PRESSURE FLAT-FORM HEAVY LIFTING BAGS

GEET Fuel Processor Plans

LEAKAGE ACCEPTANCE RATES COMPARISON METAL & SOFT SEATED VALVES API 598/API 6D/MSS SP-61/FCI 70-2

Selecting TEMA Type Heat Exchangers

15CI and 25CI Reversing Motor Pumpset Owner's Manual

Auto-belay Cable Replacement Process

BERMAD Fire Protection

Visual Index O-Rings and Seals

TYPE E Main Valve Sizes 3 /8 through 12

Scraper Passage Indicator. Electrical Indicator. Features

Morrison Bros. Co. General Product Specifications

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Vacuum Tube Solar Water heater Non-pressure. User manual

CSD WATER REMOVAL FILTERS FOR DIESEL

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

BRAZED PLATE INSTALLATION MANUAL

Chapter 7 Hydraulic System Troubleshooting

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

James M. Pleasants Company

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

Series 510 Submersible Level Transmitters

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

How To Replace A Reverse Osmosis Water Tank

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

High Performance PSA in Sheet Membrane in Water Protection

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Standard Hydraulic Piping Flushing Procedure

Engineering Specifications

Mechanical Seal Piping Plans

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Accumulators and Receivers

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

The Inside Story. Cat Fuel, Oil, and Transmission Filters

Transcription:

8 L-4090 Schroeder es provide maintenance and lubrication management professionals a complete and immediate visual oil analysis. Constructed of durable cast acrylic, they withstand most petroleum products to remain crystal clear. Although easy detection and discharge of water contamination are leading benefits, operators can also visually monitor the oil for discoloration or debris. The drain valve is made from brass with a vulcanized rubber seal. Both materials have excellent resistance to hydrocarbon and petroleum-based products, hydraulic fluids, most silicone fluids, and fuels. A detailed chemical resistance chart is available upon request. Schroeder es are designed for simple installation on most equipment. Our product line includes models for vertical and horizontal mounting, high temperature applications, large volume bowls, level indication and the all-encompassing and Level Monitor. The revolutionary 3-D can replace the problematic, old-fashioned sight plug on your oil reservoir to provide greater visibility. BENEFITS Withstand most petroleum products to remain crystal clear Continuously monitor oil level and condition Extremely low maintenance Low purchase and installation costs Save expensive equipment through early detection & action 580 West Park Road Leetsdale, PA 15056 ph. 724.318.1100 fax 724.318.1200 An ISO 9001:2008 Certified Company

(2 of 6) For many systems the 1 oz. is adequate. The 3 oz. provides additional volume and should be used when the condensation or water spillover is excessive. Schroeder also offers 16 oz. and 32 oz. es for special applications that require the ability to accumulate substantial volumes of water due to large oil reservoirs, high condensation problems or excessive water spillover. Even larger sizes and unique configurations are available for special applications. 1 oz. 3 oz. Outside Diameter: 1.75 2.5 Length: 2.38 2.38 Maximum psi: 225 200 Operating Temperature: -40 F to 165 F -40 C to 74 C Specifications: -40 F to 165 F -40 C to 74 C Commercial grade acrylic Brass drain valve ¼, ⅜ or ½ NPT brass nipples Vertical & horizontal styles Available in 16 oz. & 32 oz. sizes Stainless steel hardware available Horizontal The Horizontal is designed to be installed on equipment that has restricted vertical clearance. The design has the mounting nipple and drain valve eccentrically machined and oriented 180 apart. This provides the same ability to discharge any accumulated water. VERTICAL Part # OSG1X250 OSG1X375 OSG1X500 OSG3X250 OSG3X375 OSG3X500 OSG16X500 OSG32X500 OSG1X250HZ OSG1X375HZ OSG1X500HZ OSG3X250HZ OSG3X375HZ OSG3X500HZ Description Vertical 1 oz 1/4 NPT Vertical 1 oz 3/8 NPT Vertical 1 oz 1/2 NPT Vertical 3 oz 1/4 NPT Vertical 3 oz 3/8 NPT Vertical 3 oz 1/2 NPT Vertical 16 oz 1/2 NPT Vertical 32 oz 1/2 NPT Horizontal 1 oz 1/4 NPT Horizontal 1 oz 3/8 NPT Horizontal 1 oz 1/2 NPT Horizontal 3 oz 1/4 NPT Horizontal 3 oz 3/8 NPT Horizontal 3 oz 1/2 NPT HORIZONTAL

(3 of 6) High Temperature When oil operating temperatures or radiant heat from adjacent equipment are continually in excess of 165 F, you should consider utilizing the Schroeder High Temperature. 1 oz. 3 oz. Outside Diameter: 2.75 3.50 Length: 2.50 2.50 Maximum psi: 225 225 Operating Temperature: Specifications: 450 F 232 C 450 F 232 C Heavy-walled Pyrex glass Teflon end plates Stainless steel nuts & bolts Viton O-rings Brass drain valve ¼, ⅜ or ½ NPT brass nipples Vertical stlye only Stainless steel hardware available HIGH TEMPERATURE Part # OSG1X250HT OSG1X375HT OSG1X500HT OSG3X250HT OSG3X375HT OSG3X500HT Description High Temp 1 oz 1/4 NPT High Temp 1 oz 3/8 NPT High Temp 1 oz 1/2 NPT High Temp 3 oz 1/4 NPT High Temp 3 oz 3/8 NPT High Temp 3 oz 1/2 NPT Magnet Option Any can be equipped with a rare earth magnet that attracts and holds microscopic ferrous particles in your oil. Further analysis of these particles can help determine what component is failing for replacement. The Magnet Drain Valve is easily interchanged with the standard drain valve on any OSG product. MAGNET OPTION

(4 of 6) & Level Monitor When seeing and maintaining the level of oil in your reservoir is critical, the Oil Sight Glass and Level Monitor (OSGL) provides all the benefits of the OSG plus the ability to constantly monitor the level of the reservoir oil. The dual port model has a second 3/8 NPT thread at 180 to allow the installation of a drain valve or access to the oil reservoir utilizing a pilot tube and a pitot sample adapter. This all-in-one product provides continuous monitoring of the clarity, color, sediment, water contamination and level of the oil. Outside Diameter: 1.75 Length: Maximum psi: 225 3, 6, 9, 12, 15, 18, 24, or custom available Operating Temperature: -40 F to 165 F -40 C to 74 C Specifications: Commercial grade acrylic Brass drain valve ⅜ NPT brass nipples Available in dual port version with a second ⅜ NPT port Stainless steel hardware available Part # Description OSGL3 OSG and Level Monitor 3 OSGL6 OSG and Level Monitor 6 OSGL9 OSG and Level Monitor 9 OSGL12 OSG and Level Monitor 12 OSGL3DP OSG and Dual Port Level Monitor 3 OSGL6DP OSG and Dual Port Level Monitor 6 OSGL9DP OSG and Dual Port Level Monitor 9 OSGL12DP OSG and Dual Port Level Monitor 12 OSGL15 OSG and Level Monitor 15 OSGL18 OSG and Level Monitor 18 OSGL24 OSG and Level Monitor 24 OSGL15DP OSG and Dual Port Level Monitor 15 OSGL18DP OSG and Dual Port Level Monitor 18 OSGL24DP OSG and Dual Port Level Monitor 24

(5 of 6) 3-D The 3-D OIl Sight Glass is machined from one solid piece of impact resistant, high strength, stain-resistant cast acrylic. It has excellent resistance to hydrocarbon and petroleum-based products, hydraulic fluids, most silicone fluids, and fuels. Replaces problematic, old-fashioned oil level sight plugs. Fits virtually every oil reservoir. Revolutionary easy view design is visible from virtually any angle, minimizing false positives. NPT: ½, ¾, 1, 1¼, 1½, 2 Outside Diameter: 7/8, 11/8, 1⅜, 1¾, 2 2½ Length: 1, 1⅜, 1⅜, 1⅜, 1⅜, 1½ From last thread. Metric and custom sizes available. Maximum psi: 300 Operating Temperature: 200 F; 93 C At 66 psi. 230 F; 110 C At atmospheric pressure. Part # Description 3DBM10X1.0 Metric 10X1.0 3DBM10X1.5 Metric 10X1.5 3DBM12X1.5 Metric 12X1.5 3DBM16X1.5 Metric 16X1.5 3DBM20X1.5 Metric 20X1.5 3DBM22X1.5 Metric 22X1.5 3DBM24X1.5 Metric 24X1.5 3DBM26X1.5 Metric 26X1.5 3DBM27X1.5 Metric 27X1.5 3DBM30X2.0 Metric 30X2.0 3DBM33X1.5 Metric 33X1.5 3DB0250 3DB0375 3DB0500 3DB0750 3DB1000 3DB1250 3DB1500 3DB2000 1/4 NPT 3/8 NPT 1/2" NPT 3/4" NPT 1" NPT 1 1/4" NPT 1 1/2" NPT 2" NPT BEFORE AFTER

(6 of 6) FAQs Where is the best place to install the? We recommend installing the at the lowest point of the oil reservoir; typically the drain port. Water contamination will separate from high quality oils and migrate to the OSG where it can be purged from the system. Unwanted sediment and particles are visible in the OSG. Upon inspection, the user can determine the appropriate action to initiate. How often should the be replaced? Under normal operating conditions, the life span of the is not limited. Repeated exposure to caustic chemicals can cause staining and small surface cracks called crazes, which can lead to larger cracks and bonding failure. Environmental factors such as long periods of direct sunlight and radical swings in temperature can expedite staining or crazing. Designed to withstand normal industrial lubrication applications, the Schroeder can work for years without failure or degradation, but operators should watch for staining, crazing or microscopic oil seepage that may arise and replace the OSG immediately to insure safe and effective oil management. How do I clean the? Soap and warm water is the best way to clean the. Commercial cleaning products containing alcohol or ammonia (including Windex) should be avoided, as they may cause crazing that can expedite staining and/or compromise the bond strength. Are there any special precautions for extremely cold applications? The materials used can withstand temperatures as low as -40 F or -40 C. It is important that the water accumulation in the is managed to prohibit it from completely displacing all of the oil. As little as a tablespoon (1/4 linear volume) of oil in the chamber will provide for the volumetric expansion required when the water freezes. If enough water accumulates to displace all of the oil from the chamber, the expansion that occurs when it freezes can fracture the OSG. Although Oil Sight Glasses are a valuable, dependable and safe tool to use in extremely cold environments, it is important that they are regularly monitored to avoid excess water accumulation. We do not recommend the installation of OSGs in hard to see places on equipment in freezing environments. I just received my new 3-D. Why does the inside surface look cloudy? Polishing is not necessary for the interior walls of the 3-D BullsEye. Once installed and lubricating fluid is introduced, the view will become crystal clear and the cloudiness will disappear.