AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS



Similar documents
THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

PRESSURE REDUCING VALVES

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Assisted lift operated 2/2-way solenoid valves Type EV250B

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Automatic control equipment for HVAC systems

Float and Thermostatic Traps Series H, C and X

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

APCO SLOW CLOSING AIR/VACUUM VALVES

PRESSURE REDUCING CONTROL VALVE

Stainless Steel Single and Dual Circulation Kits

4/2-Way Pneumatic Solenoid Valve

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

Cooling system components, removing and installing

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

stainless steel pre-assembled manifolds

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

NFPA31FuelOilPiping 1 Revised

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

James M. Pleasants Company

Model 5600SE Downflow

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Automatic Control Valves WATTS EU 100 Series

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

MFP14, MFP14S and MFP14SS Automatic Pumps

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

1805 Series Relief Valves

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

HS-901(A) BASIC STEAM HEATING SYSTEMS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Direct steam injection humidifiers

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Operators manual Basic water heater

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Unit 24: Applications of Pneumatics and Hydraulics

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Model 43AP Pneumatic Controller, Style B

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

AIR LINE VALVES AND GAUGES

Hydraulic control unit series

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

TECHNICAL DATA. Dry 122a. November 12, 2013

Spare Parts List M96A.24SM/B M96A.28SM/B

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

1 DESCRIPTION OF THE APPLIANCE

Installation Instructions S

Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized

Accessories. Fittings 2. Products assembly 4. Tube Spike 3/5 mm 8 T.N.L. 9. Vacuum Breaker 10. Line Flush Valve 11. Pressure Indicator 12

GS-General Service Control Valves

Laddomat Charging unit

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

RUBBER SLEEVE KNIFE GATE VALVE

VSO MAX HP High Flow Proportional Valve

TN2000 Series Pneumatic Piston Actuators for DN125 to DN300 SPIRA-TROL Series Control Valves

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Assembly instructions VOSS quick connect system 246 NX

CHEMICAL CLEANING UNIT Product number:

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Baumann Flexsleev Sanitary Control Valve

V47 Series Temperature Actuated Modulating Water Valves

3/2-way Solenoid Valve, direct-acting, NC or NO

Pressure regulating valve with modulating kit, type DRV

API Flanged Safety Relief Valves Series 526 CATALOG

3217 North Pulaski Road Chicago, Illinois Phone: (773) Fax: (773)

System 8. ü ( System 8

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Your safety and the safety of others are very important.

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Type 3353 Angle Seat Valve

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

Transcription:

01B101-GB AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS MAIN FEATURES ADVANTAGE OF BUILT-IN MANUAL DISCHARGE - Provision for controlling operation of the automatic discharge by pressing the manual discharge pin. - By holding down the manual discharge, water flows through the orifice thus facilitating cleaning of the automatic discharge mechanism. - Rapid venting of air when filling the system. MANUAL DISCHARGE AUTOMATIC DISCHARGE

DESCRIPTION The MAXIVENT valves are inspectable thanks to the opening left by the cover after unscrewing it from the tank; therefore it is also possible to clean the internal parts (float and lever) in case of ingress of foreign matter in the valve. Tight seal between the tank and cover is thanks to the presence of an seal. Long-term efficiency and performance of the vent movement is ensured by the valve design features. The seal system is designed to withstand vibrations, therefore it is unaffected by any external vibrations. APPLICATION Thanks to its particular size, the MAXIVENT valve finds application of automatic venting of air in large size water distribution pipes (e.g. distribution manifolds in the central system) and in all cases where it is necessary to eliminate large quantities of air from the system. The MAXIVENT valve is provided with manual air vent. Valve opening and closing is determined by the float movement (up-down). When there is air in the MAXIVENT, the force of the float weight acts on the lever which is integral with the plug, thus causing it to move down. In such situation the seat is free and allows the air to be vented outside. When filling the system with water, the air entrapped in the water circuit is pushed towards the outside via the MAXIVENT valve. As soon as all the entrapped air is discharged, the water, entering the tank, pushes the float up. Consequently the lever moves the plug to press against the seat thus ensuring tight sealing of the system. INSTALLATION The MAXIVENT valve is normally installed: - In the highest point of the air separator - At the top of the columns installed in heating systems with expansion vessel - In all points where there is risk of air building up - At the top of the manifolds. After installation, in order to allow perfect air venting, unscrew the protective cap by at least two turns (such condition ensures the vent characteristics as given in the previous diagram). MXV MAXIVENT. Large capacity automatic air vent valve. 023020 3/4 02302 1 023032 1.1/4 Body Cast iron G2 entirely coated with epoxy resin Cover Cast iron G2 entirely coated with epoxy resin Manual vent valve Chrome-plated brass OT Lever Plug Float High density expanded polyethylene Seals Cap Brass OT Inlet connection F 3/4" - 1" - 1 1/4" DIN-ISO 22/1 Outlet connection F 3/" DIN-ISO 22/1, brass Air discharge rate - Operating pressure 00 00 600 00 400 300 200 100 0 0 1 2 3 4 6 Operating pressure (bar) MXV - 3/4-1 - 1.1/4 MAINTENANCE Normally the MAXIVENT valve does not require routine maintenance. Max. discharge pressure 6 bar 12 bar Min. seal pressure 0.1 bar Max. operating temperature 11 C

DESCRIPTION The DUOVENT valves are inspectable by unscrewing the cover from the tank. Tight seal between the tank and cover is thanks to the presence of an O-ring; therefore it is also possible to clean the internal parts (float and lever) in case of ingress of foreign matter in the valve. Long-term efficiency and performance of the vent movement is ensured by the valve design features. The seal system is designed to withstand vibrations, therefore it is unaffected by any external vibrations. MVD DUOVENT. Valve with double possibility of venting air from the system, either automatically or manually. The manual discharge also allows checking for correct operation and cleaning the automatic discharge orifice. 02060 1/4 020610 3/ 02061 1/2 APPLICATION The DUOVENT valve is a development on the automatic MINIVENT valve. In fact DUOVENT has the same functions as MINIVENT, i.e. it is used for automatic venting of air in water distribution pipes in order to avoid certain phenomena of damage (corrosion processes, cavitation) and loss of efficiency (air pockets in radiators) of the heating system, but it is provided with an additional device allowing manual air venting. The manual air vent device offers the following advantages: a) It allows checking the valve for correct operation b) It allows reducing times for discharging air from the system by increasing the discharge flow rate c) Easier cleaning of the orifice by forcing water to flow through it. The DUOVENT MVDR valve is provided with an automatic shut-off valve (Art. RIA) which allows removal of the vent valve without having to empty the system. During automatic operation, valve opening and closing is determined by the float movement (up-down). When there is air in the DUOVENT, the force of the float weight acts on the lever which is integral with the plug, thus causing it to move down. In such situation the seat is free and allows the air to be vented outside. When filling the system with water, the air entrapped in the water circuit is pushed towards the outside via the DUOVENT valve. As soon as all the entrapped air is discharged, the water, entering the tank, pushes the float up. Consequently the lever moves the plug to press against the seat thus ensuring tight sealing of the system. Manual venting is actuated by pushing down button (10); this can be done by exerting a pressure on the surface, for example with a screw driver. Such operation shifts head (9) integral with O-ring (12) to a position lower than the seat, thus allowing air and/or water to flow along stem. When water flows both from orifice (A) and (B), this indicates that all the air has been discharged from the system. Nominal pressure 12 bar bar Max. operating temperature 11 C MVDR Like MVD but with automatic shut-off valve RIA. (comparison between manual and automatic venting) Air discharge rate - Operating pressure 0200 1/4 02010 3/ 0201 1/2 Body Brass OT Cover Brass OT Plug EPDM rubber Spring Cap Polyamide Lever Float High density expanded polyethylene Seals Plug head Plug button Spring Connections M 1/4" - 3/" - 1/2" DIN - ISO 22/1 The automatic venting characteristics are similar to MINIVENT. The following diagram shows the automatic and manual venting curves in relation to pressure, assuming a manual plug movement of 1. mm. It is clear that the manual venting allows an appreciable increasing in the discharge rate of DUOVENT. 400 360 320 20 240 200 160 120 0 40 Manual air venting (plug movement of 1. mm) Manual air venting 0 0 1 2 3 4 6 Operating pressure (bar)

INSTALLATION The DUOVENT valve is normally installed: - In the highest point of the air separator - At the top of the columns installed in heating systems with expansion vessel - In all points where there is risk of air building up In order to ensure maximum air venting efficiency, it is advisable to install the DUOVENT valve in those points where water speed is relatively low. After installation, in order to allow perfect air venting, unscrew the protective cap by at least two turns (such condition ensures the vent characteristics as given in the previous diagram). MAINTENANCE Normally the DUOVENT valve does not require maintenance. If maintenance is required, remove the valve; the presence of shut-off valve RIA allows this operation without emptying the system. Air discharge rate - Operating pressure (Pressure equal to 3 bar) The flow rate in manual air venting varies according to the down movement of the plug, as shown in the following diagram, at a system pressure of 3 bar. 10 120 90 60 30 0 0 0, 1 1, 2 2, 3 3, Manual venting plug movement (mm) MVD 12 11 B A A. Automatic vent B. Manual vent 1. Body 2. Cover 3. Plug 4. Spring. Cap 6. Lever. Float. Seals 9. Plug head 10. Button 11. Spring 12. Seals 2 9 1 6 4 3 SIZE 1/4 3/ 1/2 CH 22

DESCRIPTION The MINIVENT valves are inspectable by unscrewing the cover from the tank. Tight seal between the tank and cover is thanks to the presence of an O-ring; therefore it is also possible to clean the internal parts (float and lever) in case of ingress of foreign matter in the valve. Long-term efficiency and performance of the vent movement is ensured by the valve design features. The seal system is designed to withstand vibrations, therefore it is unaffected by any external vibrations. APPLICATION The MINIVENT valve is used for automatic venting of air in water distribution pipes in order to avoid certain phenomena of damage (corrosion processes, cavitation) and loss of efficiency (air pockets in radiators) of the heating system. The MINIVENT MVR valve is provided with an automatic shut-off valve (Art. RIA) which allows the vent valve to be removed without having to empty the system. The MINIVENT valve is used in independent, central, radiant panel heating systems, etc. Valve opening and closing is determined by the float movement (up-down). When there is air in the MINIVENT, the force of the float weight acts on the lever which is integral with the plug, thus causing it to move down. In such situation the seat is free and allows the air to be vented outside. When filling the system with water, the air entrapped in the water circuit is pushed towards the outside via the MINIVENT valve. As soon as all the entrapped air is discharged, the water, entering the tank, pushes the float up. Consequently the lever moves the plug to press against the seat thus ensuring tight sealing of the system. INSTALLATION The MINIVENT valve is normally installed: - In the highest point of the air separator - At the top of the columns installed in heating systems with expansion vessel - In all points where there is risk of air building up In order to ensure maximum air venting efficiency, it is advisable to install the MINIVENT valve in those points where water speed is relatively low. After installation, in order to allow perfect air venting, unscrew the protective cap by at least two turns (such condition ensures the vent characteristics as given in the previous diagram). MAINTENANCE Normally the MINIVENT valve does not require maintenance. If maintenance is required, remove the valve; the presence of shut-off valve Art. RIA allows this operation without emptying the system. Body Brass OT Cover Brass OT Lever Float High density expanded polyethylene Plug EPDM rubber Spring Seals Cap Polyamide Connections M 1/4" - 3/" - 1/2" DIN-ISO 22/1 Air discharge rate - Operating pressure MV MV MINIVENT. Automatic valve with vertical air vent. MVR Like MV but with automatic shut-off valve RIA. 12 bar Max. operating temperature 11 C 0 6 60 0 4 40 3 30 2 20 1 10 0 0 1 2 3 4 6 9 10 11 12 Operating pressure (bar) 02000 1/4 020010 3/ 02021 1/2 02010 1/4 020110 3/ 02011 1/2 1. Body 2. Cover 3. Lever 4. Float. Plug 6. Spring. Seals. Cap 2 1 3 4 6 SIZE 1/4 3/ 1/2 CH 22

DESCRIPTION The MICROVENT valves are inspectable by unscrewing the cover from the tank. Tight seal between the tank and cover is thanks to the presence of an O-ring; therefore it is also possible to clean the internal parts (float and lever) in case of ingress of foreign matter in the valve. Longterm efficiency and performance of the vent movement is ensured by the valve design features. The seal system is designed to withstand vibrations, therefore it is unaffected by any external vibrations. The MICROVENT valve is provided with a vacuum breaker tongue (close to the connection) designed for improving the air venting characteristics. However such vacuum breaker tongue is not fitted when the MICROVENT valve is supplied with shut-off valve which already incorporates the tongue. APPLICATION The MICROVENT valve is used for automatic venting of air in water distribution pipes in order to avoid certain phenomena of damage (corrosion processes, cavitation) and loss of efficiency (air pockets in radiators) of the heating system. The MICROVENT MKVR and MKLR valves are provided with an automatic shut-off valve (Art. RIA) which allows the vent valve to be removed without having to empty the system. Valve opening and closing is determined by the float movement (up-down). When there is air in the MICROVENT, the force of the float weight acts on the lever which is integral with the plug, thus causing it to move down. In such situation the seat is free and allows the air to be vented outside. When filling the system with water, the air entrapped in the water circuit is pushed towards the outside via the MICROVENT valve. As soon as all the entrapped air is discharged, the water, entering the tank, pushes the float up. Consequently the lever moves the plug to press against the seat thus ensuring tight sealing of the system. INSTALLATION The MICROVENT valve is normally installed: - In the highest point of the air separator - At the top of the columns installed in heating systems with expansion vessel - In all points where there is risk of air building up MKV MICROVENT. Automatic valve with vertical air vent. MKVR Like MKV but with automatic shut-off valve RIA. MKL MICROVENT. Automatic valve with side air vent. MKLR Like MKL but with automatic shut-off valve RIA. 021210 3/ Body Brass OT Cover Brass OT Float High density expanded polyethylene Plug Polyphenylene oxide End cap Polyphenylene oxide, glass fibre reinforced Lever Polyphenylene oxide, glass fibre reinforced Seals Spring Vacuum breaker Connections M 3/" DIN - ISO 22/1 10 bar Max. operating temperature 110 C 021310 3/ 022210 3/ 022310 3/ In order to ensure maximum air venting efficiency, it is advisable to install the MICROVENT valve in those points where water speed is relatively low. After installation, in order to allow perfect air venting, unscrew the protective cap by at least two turns (such condition ensures the vent characteristics as given in the previous diagram). When it is necessary to mount a MICROVENT valve provided with vacuum breaker tongue on a RIA shut-off valve, merely lift out the tongue with two fingers. MAINTENANCE Normally the MICROVENT valve does not require maintenance. If maintenance is required, remove the valve; the presence of shut-off valve Art. RIA allows this operation without emptying the system. 1. Body 2. Cover 3. Float 4. Plug. End cap 6. Lever. Seals. Spring 9. Vacuum breaker 2 1 6 9 4 3

Air discharge rate - Operating pressure 0 4 40 3 30 2 20 1 10 0 MKV MKL 0 1 2 3 4 6 9 10 Operating pressure (bar) MKV - MKL Automatic shut-off valve RIA allows the air vent valves (MINIVENT, DUOVENT, and MICROVENT) to be removed without having to empty the system. The RIA shut-off valve is fitted with a device for quick total emptying of the water from the valve. RIA Automatic shut-off valve. 02900 1/4 x 1/4 029010 3/ x 3/ 02901 1/2 x 1/2 RIA Body Brass OT Lever Polyphenylene oxide, glass fibre reinforced Plug with O-ring Spring Connections M/F 1/4" - 3/" - 1/2" DIN - ISO 22/1 SIZE 1/4 3/ 1/2 B C 11 11 11 CH 24 Body Screw O-ring Brass OT, chrome-plated Brass OT, chrome-plated SMM Manual valve for venting air from radiators with adjustable discharge nozzle, manual discharge opening with handwheel. 02106 1/ 0210 1/4 02110 3/ 0211 1/2 10 bar Max. operating temperature 9 C

Body Screw Discharge nozzle and handwheel O-ring Brass OT, chrome-plated Brass OT, chrome-plated Polyamide, reinforced with glass fibre 10 bar Max. operating temperature 9 C The components and dimensional characteristics of the valves allow a perfectly tight seal associated with very easy operation. VMM Manual valve for venting air from radiators with adjustable discharge nozzle, manual discharge opening either screw driver or coin or wrench CH. PMC Manual valve for venting air from radiators with adjustable discharge nozzle, manual discharge opening either screw driver or coin or wrench CH to avoid manual tampering. RSR Radiator drain valve for quick and easy emptying of the water contained in the radiator, without requiring emptying the entire system. 026206 1/ 02620 1/4 026210 3/ 026306 1/ 02630 1/4 026310 3/ 02631 1/2 02600 1/4 026010 3/ 02601 1/2 VMM CH Wrench for valves RSR, VMM, PMC. 026101 Inlet hole smaller than the outlet hole to avoid ingress of particles which could block air discharge. O-ring for easy assembly and perfectly tight seal on the radiator. Handwheel designed for manual opening with screw-driver, coin or wrench CH/VP. Limit stop on the screw to avoid the handwheel coming out from the valve body. Adjustable discharge nozzle, glass fibre reinforced nylon body. PMC Valve handwheel PMC with opening by screw-driver, coin or wrench CH/VP. Slot for opening valves PMC, RSR Slot for opening valve VMM. CH/VP Wrench flat for adjusting discharge nozzle body. Wrench CH/VP can be left inserted on the body. The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. WATTS CAZZANIGA reserves the right to carry out any technical and design improvements to its products without prior notice. G1- MVD - GB - 01/ 02 WATTS Cazzaniga S.p.A. Via Parco, snc - 20046 Biassono (MI) - Italy Phone ++39 039 49.6.1 - Fax ++ 39 039 49.6.2 www.wattseurope.com e-mail: info@wattscazzaniga.it