OKU SOLAR HEATING FOR SWIMMING POOLS



Similar documents
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

SWIMMING POOL HEAT PUMP Owners Manual

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Cooling system components, removing and installing

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Failure code manual. content

Installation and maintenance instructions. Danfoss Vent

REMOVAL AND INSTALLATION

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Battery Backup Sump Pump System

H41 Electrical Stage Aft Air Conditioner Unit Installation

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

RESIDENTIAL INSTALLATION MANUAL HELIOCOL SOLAR POOL HEATER

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

Laddomat Charging unit

ECOCIAT. Domestic hot water heat recovery unit

SunMaxx Solar Filling Station Operating Instructions

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

swimming pool accessories

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Zenith Solar thermal 4.5m pump station Installation manual

Lawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version Roseland Drive Macedonia, Ohio

VOYAGER 570G. 744A Sprayer Control

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

Constructing Cistern Installations

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

UNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT

RESERVDELSLISTA NORMFINISH DP14

Portable Air Conditioner

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Spare Parts List M96A.24SM/B M96A.28SM/B

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

ALTRA 400 Operator Manual. Planographs and Wiring Diagrams

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

SHOWERS SHOWERS

Installation instruction of the flat solar collectors models ES1V2.0, ES1V2.65, ES2V/2.0 AL, EM2V/2.0, ES2V/2.65, ES2H/2.65 on the inclined tile roof.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Making Your Home Ready For Solar Water Heating

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

ATTIX 350, 360, 8 GALLON

Electric Instantaneous. Water Heaters. Service manual

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

Hydraulic control unit series

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

INSTALLATION INSTRUCTIONS

SHOT BLAST CABINET MODEL NO: CSB20B

SELECTION, APPLICATION AND MAINTENANCE

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

CHEMICAL CLEANING UNIT Product number:

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

LED MOTION ACTIVATED FLOOD LIGHT

Oil and Coolant Circulating Heating System. Model - OCSM

Solar Collector Series. Product List

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

SMD Rework Station TABLE OF CONTENTS

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

AIR LINE VALVES AND GAUGES

AFE424 SERVICE PARTS

Description of functions

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

FullFloXF. 2-Way and 3-Way Diverter Valve and Check Valve. Installaton and Operation Instructions

Backup Sump Pump Systems. 1 NEXT

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV

Finding and Fixing Leaks

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Please also see 10 golden rules for correct Saniflo installation on

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Duct Humidity Transmitter

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

2003 ACCORD - Automatic Transmission Removal

SCC 101 E Valid as of E11SE0404 up to E11SE... SCC 101 E

GENERATOR MODEL NO: FG3050 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0310

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Air Vantage 500 Kubota

HERZ-Thermal Actuators

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

MDT5N25 & MTD5N40 SERVICE PARTS

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Transcription:

OKU SOLAR HEATING FOR SWIMMING POOLS Instruction for installation an operating Introduction Solar heating for swimming pools with OKU-Absorbers normally will be operated with a direct circuit. The water from the pool will be pumped dir ectly through the absorbers. You don t have to interpose a heat exchanger. Different configurations of OKU swimming pool solar heat ing. Operation with filter pump via three-way motor ball valve with difference-temperature regulation This configuration can usually be selected if the absorbers are not to be set up higher than 6 m abov e the surface of the water. The threeway motor ball valve is integrated into the pressure line of the filter installation. Because of the difference-temperature regulation the ball valve is changed over when the absorber temperature is higher than the temperature of the water of the swimming pool. The f ilter stream is then pumped thr ough the absorbers. The warmed water flows back into the filter circuit by way of a Tee.. Operation with own pump an difference temperature regulation integrated into the filter circuit In many cases it may be sensible or even necessary to install a separate pump for the solar heating. For example when the deliv ery head from the water level to the absorber panel is more than 6 m. The water is diverted from the filter installation by way of a Tee and pumped through the absorbers by the auxiliary pump. This pump is switched by the difference-temperature regulation to ens ure that it only runs to actually win energy. The filter and solar pump are separately regulated. It is usually advisable to integrate non-return valves in both the solar and the filter circuit.. Operation with own pump and difference-temperature regulation - piping independent of filter circuit This configuration is chosen when the filter piping is difficult of access. The water is sucked out of the swimming pool by an immersion pipe, pumped thr ough the absorbers, and the warmed water is conducted back into the swimming pool. Her e too the difference temperature regulation ens ures that the pump only r uns to win energy. If the pump is mounted abov e the water level and the delivery head is more than 5 m, a non- return valve should be incorporated. ) OKU-Absorber 5) Three-way motor ball valve 9) Stop cock (downdraft brake) ) Difference-temperature regul ation OE 6) Temperature sensor, absorbers 0) Drain cock ) Filter installation 7) Temperature sensor, swimming pool ) Pump for solar circuit ) Solar circuit forward and return 8) Vent valve ) Non-return valve The water of the swimming pool c an flow through the oku absorbers in either direction, so they can be mounted both lengthwis e and side by side. The individual rows of absorbers are connected on a Tichelmann principle (same routes for each row). It is not advisable to connect more than ten absorbers in series.

We recommend to r ead the following instruction thoroughly before starting the installation an to mak e a plan of how to connect the absorbers in case your arrangement of absorbers differs from the example s hown below. This example represents a system with 6 OKU abs orbers in lines at items. Depending on the s ize of your swimming pool and the ar ea available for the absorbers numerous other schemes of installation are also possible. 6 8 0 5 9 7 Operation with filter pump via three-way motor ball valve with difference-temperature regulation ) OKU absorber 5) Three-way motor ball valve 9) Stop cock (downdraft brake) ) Difference-temperature regul ator OE 6) Temperature sensor, absorbers 0) Drain cock ) Filter installation 7) Temperature sensor, swimming pool ) Pump for solar circuit ) Solar circuit forward and return 8) Vent valve ) Non-return valve USE ISO VALVE AFTER SOLAR PUMP AS A FLOW RESTRICTOR..TURN / TURN OFF NOTE:A FLEXIBLE HOSE IS NEEDED BET WEEN THE PUMP AND T HE FLOW/RETURN PIPING CONNECTIONS This applies to BADU pump onl y check with Alpha Energy for changes

Installation of the system. OKU-Absorbers are supplied with connecting pieces that are opened diagonally. If further connections ar required to connect the absorbers in series only the cap has to be cut off.. Place the OKU-Absorbers on the designated areas in the arrangement that is desired and connect them with hos e connections and hose saddles according with the the scheme of connection. In case of steeper sloping roofs roof fastenings must be carried out simultaneously to prevent absorbers from slipping away during installation. It is recommended that you us e a TEK screw type fixing for fitting the panel to the r oof, a flat washer is needed under neath the TEK head and a silicone washer is required between the bottom of the panel and the top of the roof to make water proofed.. To make circuit points for supply and return lines connect the 5mm PVC joiner into the hose fitting and add it with the hos e coupling on the abs orber. If you take a pipe dia. 5 mm or bigger you have to glue a 5 x 0/50/65 PVC Inc reasing bush or valve socket to convert to another type of pipe.. Vent valve (8): The vent valve must be installed vertically. Glue in connection correspondingly and screw in vent valve. 5. Install -way valve (5) behind filter pump (). to the absorbers 5 back to the swimming pool 7 out of the swimming pool The iso valve installed after the so lar pump is to be used as a flow restrictor as well, turn the valve / turn off 6. Put tee for collector forerun into pipe leading to the pool. Glue Stop c ock (9) - downdraft brake into forerun pipe

7. Construct and fix forerun and return travel of collector (). If for winter a drain cook is needed glue a reducing tee with reducing piece /" for the drain cook. 8. Regulation: Pleas e take a look at the instruction for installation and oper ating for the difference-temperature regulation and the thr ee-way motor ball valve respectively the pump. Attention should be paid to the ac complishment of electrical installation. Swimming pools systems have to be equipped with a ear th leakage circuit breaker. Fasten collector sensor (6) to absorber with clamp. Glue reducing tee with nipple /" f or swimming pool sensor (7) into pipe coming from the pool and s crew in sensor. Fix the difference-temperature regulator and fasten it like the wiring diagram. Use wires with cross-section x mm² to lengthen sensor adaptors. If you take a pump with mor e than 600 W charging rate or three-phase pumps, you have to install a contactor. Operating Instruction To start the system adjust the difference temperature to approx. or C and plac e the hand switch on automatic. In systems working with filter pumps adjust the filter cycle to the hours of sunshine. Installations with own pump wor ks independent f rom the filter circuit. If after a few minutes the system works still with air in it, close the stop cock (downdraft brake) a little until the water escape at the intake nozzle is majority free of air. The stop cock now always stay this way. Additionally you can close the cover cap of the vent valve. Operating the system in winter OKU-Absorbers are frost resistant. Due to the pipes the system must be emptied in winter nevertheless. Usually systems which emptied when they re switched off, don t need any precaution. Advice to glue pvc pipes Glue pvc pipes only if they re absolutely dry. Water, condensates and humidity pr event a good connection. Don t glue under a Temperature of 5 C. The time f or drying is circa hours, do not use it with pressure before. Clean ends and fittings with a cleaner. Glue both parts the same way. Take a flat brush. It s important to disperse the glue lengthwis e from the inside to the outside. Directly after apply the glue you hav e to plug ends and fittings together. Take of the surplus glue. Clean the br ush with cleaner.

How to fasten on a pantiles tiled roof. Hook for pantiles tiled roof Art.N. Screw-in pipe clamp /" zinc plated with a gum inlay Ar t.n. Perforated tape zinc plated x Art.N 0 with a s crew 5 x 6 Art.N,5 - m

Pantiles OKU-Absorber Art. N 000 and Art. N 00 Rafter How to fasten on a flat roof On a flat roof you have to safe the OKU-Absorbers against the wind. Therefore you can stretch a wire rope or a perlon-hurry against the absorber field at intervals of circa m and anc hor it on the edge of the roof. You also can weigh the abs orbers down directly or you can fasten them with gar den-plates and U-profiles. Take a look at the diagram below.

How to fasten it on a sloping roof (slated roof or cement asbestos roof) The fastening on a slated or cement asbestos roof is comparable with the fastening on a tiled r oof. But you have to screw-in the ring-screw through the roofing into the foundation. If you have a wooden foundation screw it into the boar ding or battens. If you bore slate or cement asbestos you have to do it without the slugging device to get around splitting the plates. After screw-in the screw you have to seal it up with silicone or another sealing compound like this.