American College of Radiology Mammography Accreditation Program



Similar documents
Update on MQSA and ACR Mammography Accreditation

MQSA, FDA Regulations, and Inspections

Annual MQSA Inspection Questions NMQAAC April 19, 2004

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

The American College of Radiology Stereotactic Breast Biopsy Accreditation Program: Frequently Asked Questions (Updated: August 24, 2015)

Quality Control of Full Field Digital Mammography Units

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

Update on ACR Digital Mammography QC Manual

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

Dose Measurement in Mammography; What are we measuring? David E. Hintenlang, Ph.D. DABR University of Florida

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Sustaining a High-Quality Breast MRI Practice

The Mammography Quality Standards Act Final Regulations Document #1

Breast MRI Quality Control

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

MQSA and ACR Digital Breast Tomosynthesis Mammography Accreditation

2/28/2011. MIPPA overview and CMS requirements. CT accreditation. Today s agenda. About MIPPA. Computed Tomography

The American College of Radiology Breast Ultrasound Accreditation Program: Frequently Asked Questions

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D.

Mammography. For 35+ years, screenfilm has been the gold standard for breast cancer detection

Personalized Breast Screening Service

ADMINISTRATIVE RULES OF THE VERMONT BOARD OF RADIOLOGIC TECHNOLOGY

Digital Breast Tomosynthesis QC Requirements

Medicare Part B. Mammograms - Updated Billing Guide for Screening and Diagnostic Tests

Hologic Selenia Dimensions C-View Software Module. October 24, 2012

D. FREQUENTLY ASKED QUESTIONS

How To Compare Mammography To A 3D System

Digital Mammography Update: Design and Characteristics of Current Systems

MAMMOGRAPHY GOALS AND OBJECTIVES

Quality Control and Maintenance Programs

Aspire FCRm/CRm Fujifilm CR for Mammography

Mammography. What is Mammography?

BREAST IMAGING. Developed by the Ad Hoc Committee on Resident and Fellow Education of the Society of Breast Imaging

Radiation Safety Issues for Radiologic Technologists

A Guide to Breast Imaging: The Latest Technology for Screening and Detecting Breast Cancer

Compliance Guidance for QUALITY ASSURANCE MANUAL (2 nd Edition)

AOAC Research Institute PERFORMANCE TESTED METHODS SM PROGRAM. POLICIES and PROCEDURES

Mammography: Dosimetry ACMP Annual Meeting Virginia Beach Saturday, May 2, 2009 Lawrence N. Rothenberg, Ph.D. Department of Medical Physics Memorial

Department of Veterans Affairs VHA HANDBOOK Washington DC April 28, 2011 MAMMOGRAPHY PROGRAM PROCEDURES AND STANDARDS

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration

ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY

BREAST CHARACTERISTICS AND DOSIMETRIC DATA IN X RAY MAMMOGRAPHY - A LARGE SAMPLE WORLDWIDE SURVEY

Digital Mammogram National Database

Coronis 5MP Mammo. The standard of care for digital mammography

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) ACCREDITATION STANDARDS FOR SCHOOLS OF RADIATION THERAPY TECHNOLOGY

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

RADIATION PROTECTION PROGRAM (RPP) GUIDANCE

Radiation Rule Guide. Veterinary Facilities. Hawaii Administrative Rules, Chapter 11-45, Radiation Control. Hawaii State Department of Health

ACR BI-RADS ATLAS MAMMOGRAPHY MAMMOGRAPHY II. REPORTING SYSTEM. American College of Radiology 121

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

PET Accreditation Program Requirements

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Applicable Models ME511L, ME551i2, MS31i2, MS33i2, MS51i2, MS53i2

portable x-ray survey report

Nuclear Medicine Accreditation Program Requirements

2012 LACC Clinical Obligations & Grading System. Attendance Requirement

Agency for Health Care Administration

Transnational Association of Christian Colleges and Schools

Board of Addiction and Prevention Professionals (BAPP)

Radiation safety in dental radiography

VI. FREQUENTLY ASKED QUESTIONS CONCERNING BREAST IMAGING AUDITS

ADMISSIONS AND EDUCATIONAL STANDARDS. Adopted July 2007

Radiology Physician Performance Measurement Set

Compliance Guidance for FLUOROSCOPIC QUALITY CONTROL

STATE OF OKLAHOMA RADIOLOGIST ASSISTANT LICENSURE ACT TITLE 59, SECTIONS

Highmark Provider Privileging Requirements

CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems

Part 89 PRACTICE OF RADIOLOGIC TECHNOLOGY (Statutory authority: Public Health Law, Sections 3504, 3510(1)(g), 3502(4), 3507(2) and (7))

U.S. ELECTION ASSISTANCE COMMISSION

Breast Density Legislation: Implications for primary care providers

QUESTIONS AND ANSWERS LIMITED-SCOPE X-RAY OPERATORS Rules and Regulations Pertaining to Radiation Control (6CCR )

SUBCHAPTER B: ENVIRONMENTAL TESTING LABORATORY ACCREDITATION

MQSA Quality Control Manual for Monochrome Displays for Mammography

X-RAY REGULATORY GUIDE

Quality control tests of diagnostic radiology equipment in Hungary, and its radiation protection aspects

Radiation safety in dental radiography

IAEA-TECDOC-1447 Optimization of the radiological protection of patients: Image quality and dose in mammography (coordinated research in Europe)

Analysis of Causes for Reject X-Ray Films as a Quality Assurance Element in Diagnostic Radiology in Jos University Teaching Hospital(JUTH)

X-ray (Radiography) - Bone

The Regulations on Certification of Civil Aircraft Maintenance Personnel Training Organizations

General requirements. 1. Administrative Controls.

Frequently Asked Questions: The following regulations are provided to answer some of the many questions that are asked of this office.

X-ray (Radiography) - Abdomen

Transcription:

American College of Radiology Mammography Accreditation Program

Objectives Overview of the ACR Mammography Accreditation Program Interrelationship between mammography accreditation, FDA certification and annual inspections How to successfully apply for accreditation What to do if you do not succeed Analysis of accreditation deficiencies

ACR Mammography Accreditation Program Began in 1987 QC Manual first published in 1990 Judy M. Destouet, M.D. chairs Committee on Mammography Accreditation Currently accredit over 12,000 units at 9000 facilities

Facility Requirements Under MQSA All mammography facilities must be Accredited Certified Inspected Complementary, not duplicative

Accrediting Bodies Responsibilities Under MQSA Facility standards review Clinical image review Physics survey review Random clinical image review On-site visits Mechanism to deal with complaints Reporting and record keeping Maintain reasonable fees

ACR has Updated all Application Materials and Final Reports Forms Revised to be consistent with Final Rules (FDA regulates accrediting bodies, too) New personnel sections no longer ask for CV s, training certificates Streamlined: redundant and unnecessary questions eliminated Reports Take advantage of capabilities of ACR s new accreditation software Clear instructions for proceeding after deficiencies

What Must a Facility Do to Pass Accreditation?

Know When Your MQSA and Accreditation Certificates Expire Against the law to perform mammo without a current MQSA certificate Medicare will not reimburse under expired certificate Look for ACR expiration dates on certificate and unit label

Meet All Application Deadlines Renewal notices sent out 8 months prior to accreditation expiration ACR must receive the complete entry application within 6 months prior to expiration You have 45 calendar days to return completed testing to ACR This guarantees completion of the review process before accreditation expiration

Follow Instructions Submitting Clinical Images Images should be negative BI-RADS assessment category 1 nothing to comment on breasts are symmetrical no masses, architectural disturbances or suspicious calcifications BI-RADS assessment category 2 ( benign ) will be accepted with prior approval from ACR Examples of your facility s best work Within 30 days of the phantom image and within the time period on the QC chart Supervising radiologist should review & approve the images

Submit Appropriate Density Images Fatty BI-RADS Composition Cat 1 Composed Almost Entirely of Fat BI-RADS Composition Cat 2 Scattered Fibroglandular Densities Dense BI-RADS Composition Cat 3 Heterogeneously Dense BI-RADS Composition Cat 4 Extremely Dense

Clinical Image Quality Evaluated in Eight Categories Positioning* Compression* Exposure level Contrast Sharpness Noise Artifacts Exam identification Review evaluation criteria in Clinical Image Evaluation section of 1999 QC Manual before submitting images (*Primary reasons for accreditation failure)

Follow Instructions Submitting Phantom Images & Dosimeter Make a test exposure without the dosimeter Dosimeter or disk should not cover fibers, specks or masses Criteria used by ACR Phantom Image Reviewers is in 1999 ACR QC Manual

Phantom Results Have Improved % of films not meeting ACR criteria Approx 11% did not meet criteria between 1993 and 1999 1993 approx 16% 1994 approx 16% 1995 approx 16% 1996 approx 7% 1997 approx 6% 1998 approx 6% 1999 approx 7%

26-50 Fail Rates 50% 45% 40% 35% 30% 25% 20% 15% 10% 5% 0% 43% 51-75 76-100 101-125 126-150 151-175 176-200 201-225 226-250 251-275 276-300 over 300 Total Overall Phantom Fail Rates 1993-1999 28% 16% 11% 8% 6% 6% 8% 8% 16% 17% 18% 11% Average Dose

Other Things to Keep in Mind

Notify ACR When Installing a New Mammography Unit Before use Physicist must conduct Equipment Evaluation Call ACR for instructions to accredit the unit If more than 1 year left on accreditation Full testing (clinical-phantom-dose-processor) Reduced fee If approved, same exp dates as other unit(s) If less than 1 year left on accreditation Early renewal of entire facility (all units) Usual fee If approved, exp date for all units is old +3 yrs

Equipment Evaluation Must be done by qualified medical physicist This evaluation is an acceptance test; evaluates different features in addition to those tested as part of the medical physicist s annual QC survey Must be done (& all problems fixed) before equipment used on patients Must be submitted to ACR during initial application of new (or used) mammo unit

FDA Final Rules Equipment Standards: section 900.12(b) X-ray units (e.g., flat and parallel compression) Film and intensifying screens Film processing Film viewing Quality Assurance - Equipment: section 900.12(e) Facilities must conduct these tests at proscribed intervals and equipment must meet performance standards Different from equipment standards

ACR Has a Form to Help You Supplement Your Annual QC Survey Report for the Equipment Evaluation Section VI (MQSA Requirements for Mammography Equipment) in physicist s chapter of QC Manual Also downloadable from the ACR website Simple Yes/No/NA checklist format

www.acr.org

When Must a Facility Have an Equipment Evaluation Done? After installation of new (or used) x-ray unit or processor After x-ray unit or processor disassembled and reassembled at the same or new location After x-ray tube replacement After collimator replacement After filter replacement After AEC unit or sensor replacement

FDA Policy Guidance Help System Revised May 2001

You Have 2 Attempts at Accreditation Before Failing A first deficiency is NOT a Failure (ACR does not notify FDA) Do NOT have to discontinue mammo Take corrective action on your own Repeat deficient test (if >2 months on MQSA certificate) Reinstate (if < 2 months on MQSA certificate) Appeal Withdraw

A 2 nd Deficiency is a Fail ACR notifies FDA after a 2 nd deficiency FDA sends cease mammo letter Facility may Reinstate by reapplying and retesting in all areas after Submitting corrective action plan to ACR ACR reviews and approves completion ACR sends facility testing materials ACR notifies FDA of Reinstatement FDA sends interim notice and 6-mo provisional certificate (if necessary)

A 3 rd Deficiency is a 2 nd Failure Closer Oversight Necessary ACR notifies FDA after a 3 rd deficiency FDA sends cease mammo letter Facility must have Scheduled On-Site Survey (SOSS) in order to Reinstate Submit corrective action plan to ACR ACR reviews and approves completion SOSS radiologist, medical physicist, ACR staff technologist After SOSS, if no other corrective action needed, facility may reinstate

Accreditation Approval Rates 2000 After Initial or Renewal application 69% approved 31% had a deficiency After Reinstating 90% approved 10% had a deficiency resulting in failure Majority of deficiencies are due to poor clinical image quality

Alex, I ll take RADIOLOGY, please, for $200. OK, John. The American College of Radiology wants increased Medicare reimbursement for this breast imaging procedure.

What is mammography?

www.acr.org