Rosemount 751 Field Signal Indicator



Similar documents
Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

Rosemount 1199 Submersible Seal

Rosemount 1199 Submersible Seal

Model 3051 Pressure Transmitter with HART Protocol

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Rosemount 708 Wireless Acoustic Transmitter

Rosemount 248 Wireless Temperature Transmitter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

Emerson Smart Wireless Gateway Solutions

Compact pressure switch Flameproof enclosure Ex d Model PCA

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued

Technical Information RIA14

3DLevelScanner II TECHNICAL DATA SHEET

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Rosemount 248 Temperature Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter

TEIP11 I/P signal converter for standard signals. Measurement made easy

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Replacing Displacers with Guided Wave Radar

Explosion proof enclosures

Micro Motion Model D and DL Coriolis Flow and Density Meters

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Instruction Manual. T3111 T3111L T3111P T3111Ex

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Duct Humidity Transmitter

Technical data sheet TDS0070

S-series Mass Connection Solutions

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter

Terminal Boxes Series 8146

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Import the Gateway Certificate to the Browser

Micro Motion 3098 Gas Specific Gravity Meter

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Microcor Wireless Transmitter (MWT)

How To Make A Smart Transmitter

Flameproof Audible Signal 115 db (A) Series YA90

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

2.12. page Products for Explosion hazardous Environment

Differential-Hall-Effect based Sensors Series A5S Overview

Mobrey Hydrastep and Hydratect

Triple Waveband Infra-Red Flame Detection

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Fisher 846 Electro-Pneumatic Transducer

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 644 Temperature Transmitter

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

3500/93 System Display

Plastic tube flowmeters Series PT/PS

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Technical Data Sheet. 3DLevelScanner

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Scraper Passage Indicator. Electrical Indicator. Features

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Rosemount 214C Temperature Sensors

How To Use A Flowmeter

Operating Instructions

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Micro Motion Model 2200S Transmitters

Rosemount 3144P Temperature Transmitter

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

and Accelerometers

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Digital inductive conductivity transmitter

Thermatel Model TA1 Mass Flow Transmitter

TorqPlus TM Electric Valve Actuators and Controls

Rosemount 702 Wireless Discrete Transmitter

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Toroidal Conductivity Sensor

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Mobrey open channel flow measurement systems

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Lockout Specification BW Clip Maintenance-free single gas detector

Precision digital pressure gauge Model CPG1500

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Inductive sensor NI10-M18-Y1X-H1141

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Plug and Socket Devices SolConeX 16 A Series 8570

Emerson Smart Wireless Gateway

Transcription:

Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available with explosion-proof and intrinsic safety certifications Provides flexible mounting options

Rosemount 751 August 2014 Transcend Your Integral Meter Display with the Rosemount 751 The Rosemount 751 Field Signal Indicators provide a means of displaying important process variables. These devices operate with any two-wire transmitter that measures input variables such as pressure, flow, liquid level, or temperature. Rosemount indicators are ideal for installations where an integral meter would be difficult to view. The large, 2 1 /4-in. diameter meter face has a 2-in. long scale for easy readability. A zero adjustment is located on the meter faceplate (accessible with the housing cover removed). The meter can be rotated within the enclosure for convenient viewing in 90-degree increments. Rosemount 751 Indicators are designed for use in industrial environments where all-weather performance is necessary. These units are vibration- and corrosion-resistant, and explosion-proof or intrinsically safe. An LCD display meter or analog meter may be ordered to meet specific application requirements. LCD display meter The LCD display meter may be configured from a 4 ma point of 999 to a 20 ma point of 9999 with a linear or square-root response. A 20-segment bar graph at the bottom of the display directly represents the 4 20 ma signal. Changing the 4 ma and 20 ma points is easy. Just remove the housing and meter covers, and press the meter faceplate buttons. The meter can be rotated in 90-degree increments within the enclosure for convenient viewing. Analog meter With the analog meter, several meter scaling options are available to suit special application requirements with ±2 percent of calibrated span accuracy. Linear 0 to 100 percent meter scaling is adequate for the majority of measurement applications. With a flow transmitter, a logarithmic 0 to 100 percent flow scale is available. As an option, the user can specify special meter scaling for direct readout in psi, gph, F, C, or other convenient engineering units. Content Ordering Information............................... 3 Specifications...................................... 5 Product Certifications............................... 7 Dimensional Drawings.............................. 10 2

August 2014 Rosemount 751 Ordering Information Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 5 for more information on Material Selection. Table 1. 751 Field Signal Indicator Ordering Information The Standard offering represents the most common models and options. These options should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product description 751 Remote Signal Indicator Input signal A 4 20 ma dc B 10 50 ma dc (not available with LCD display meter) C 40 200 mv dc (not available with LCD display meter) Meter scale M1 Linear Analog Meter, 0 100% Scale M2 Square Root Analog Meter, 0 100% Flow M6 Square Root Analog Meter, 0 10 M4 (1) Linear LCD display Meter, 0 100% Scale M7 (1) Special Scale LCD display Meter (specify range, mode, and engineering units) M8 (1) Square Root LCD display Meter, 0 100% Flow M9 (1) Square Root LCD display Meter, 0 10 Product certificates NA No Approval Required E2 INMETRO Flameproof I2 INMETRO Intrinsic Safety K2 INMETRO Flameproof, Intrinsic Safety E3 NEPSI Flameproof E5 FM Explosion-Proof E6 CSA Explosion-Proof E7 IECEx Flameproof E8 ATEX Flameproof I5 FM Intrinsic Safety and Non-incendive I6 CSA Intrinsic Safety I7 IECEx Intrinsic Safety I8 ATEX Intrinsic Safety N1 ATEX Type N Non-incendive C6 CSA Intrinsic Safety, Non-incendive, and Explosion-proof approval combination K5 FM Intrinsic Safety, Non-incendive, and Explosion-proof approval combination KM Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety IM Technical Regulations Customs Union (EAC) Intrinsic Safety EM Technical Regulations Customs Union (EAC) Flameproof NM Technical Regulations Customs Union (EAC) Type N 3

Rosemount 751 August 2014 Table 1. 751 Field Signal Indicator Ordering Information The Standard offering represents the most common models and options. These options should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Options (include with selected model number) Mounting bracket B Mounting Bracket for Flat Surface or 2-in. Pipe Reducer C Stainless Steel Reducer ¾- to ½-in. for Conduit Connection (see Figure 1 for reference) Bar code tag BT Customer Specified Barcode Tag Extended Product warranty WR3 3-year limited warranty WR5 5-year limited warranty Typical model number: 751 A M1 NA BC (1) May be reconfigured in the field. 4

August 2014 Rosemount 751 Specifications Housing specifications Physical specifications Material selection Emerson provides a variety of Rosemount product with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product, materials, options and components for the particular application. Emerson Process Management is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product, options, configuration or materials of construction selected. Conformance to specifications [±3σ (Sigma)] Technology leadership, advanced manufacturing techniques, and statistical process control ensure specification conformance to at least ±3σ. Materials of construction Enclosure Low-copper aluminum Paint Polyurethane O-rings Buna N Meter mounting materials GE polyphenylene oxide plastic Electrical connections 3-pole terminal block with 8 32 nickel-plated brass screw terminals, with 3 /4 14 NPT conduit (stainless steel 3 /4- to 1 /2-in. reducer available as an option). Enclosure rating NEMA Type 4x. CSA Type 4x. IP66 Weight Indicator only: 1.8 kg (4 lb) Indicator with optional mounting bracket: 2.27 (5 lb) LCD display meter specifications Functional specifications Input signal 4 20 ma dc Display 4 ma point limits 999 to 1000 Span limits 200 to 9999 The sum of the 4 ma point and span must not exceed 9999. Adjustments are made using non-interactive zero and span buttons. Display options Standard display response is linear with ma input. Optional square root or filtered response may be selected. Overload limitations 666 ma, maximum Temperature limits Storage 40 to 85 C ( 40 to 185 F) Operating 40 to 70 C ( 40 to 185 F) (1) (1) For temperatures below -20 C or above 60 C the LCD display may not be readable, but the loop will remain intact and the LCD display will not be damaged. Humidity limitation 0 to 95 percent non-condensing relative humidity Update period 750 ms Response time Responds to changes in input within a maximum of two update periods. If the filter is activated, then the display responds to the change within nine update periods. Voltage drop 0.7 Vdc typical, 1.0 Vdc maximum Tagging The indicator will be tagged, at no charge, in accordance with customer requirements. All tags are stainless steel. The standard tag is permanently attached to the indicator. Tag character height is 1 /16 in. (1.6 mm). A wired-on tag is available upon request. 5

Rosemount 751 August 2014 Performance specifications Digital display resolution 0.05 percent of calibrated range ± 1 digit Analog bar graph resolution 5.0 percent of calibrated range Indication accuracy 0.25 percent of calibrated range ± 1 digit Stability 0.1 percent calibrated range ± 1 digit per six months Temperature effect 0.01 percent of calibrated range per C on zero 0.02 percent of calibrated range per C on span over the operating temperature range Power interrupt All calibration constants are stored in EEPROM memory and are not affected by power loss. Failure mode LCD display meter failure will not affect transmitter operation. Under/Over range indication Input current < 3.5 ma: Display blank Input current > 22.0 ma: Display flashes 112.5 percent of full scale value or 9999, whichever is less Physical specification Meter size 2 1 /4-in. diameter face with four 1 /2-in. high characters Analog meter specifications Functional specifications Input signal 4 20 ma dc 10 50 ma dc 40 200 mv Note Maximum series resistance is ten ohms for ammeters. Meter indication 0 to 100 percent linear scale 0 to 100 percent flow scale Special optional ranges Overload limitation 150 percent of rated end scale value for two minutes Temperature limits -40 to 65 C ( 40 to 150 F) Humidity limits 0 to 100 percent relative humidity Zero adjustment Adjustment screw on face of meter Performance specifications Indication accuracy ±2 percent of calibrated span Temperature effect Less than 2 percent of full scale at any point within the temperature limits Physical specification Meter size 2 1 /4-in. diameter face with 2-in. long scale 6

August 2014 Product Certifications Approved manufacturing locations Rosemount Inc. Chanhassen, Minnesota USA Emerson Process Management GmbH & Co. Wessling, Germany Emerson Process Management Asia Pacific Private Limited Singapore Emerson Process Management India PVT LTD - Daman, India European directive information The EC declaration of conformity can be found on 00825-0100-4378. The most recent revision can be found at. Ordinary location certification for FM approvals As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM Approvals, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Electro Magnetic Compatibility (EMC) EN 61326:2006 ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. Hazardous locations certifications North American certifications Factory Mutual (FM) approvals E5 I5 Certificate Number: 0T2H8.AE Standards: FM3600-1989, FM3615-1989 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition Proof for Class II, Division 1, Groups E, F, and G. Dust-ignition Proof Class III, Division 1 Indoor and outdoor use, NEMA Type 4X Certificate Number: 0T9H2.AX Standards: FM3600-1989, FM3610-1988, FM3611-1986, FM3810-1989 Intrinsically safe for Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1. Nonincendive for Class I, Division 2, Groups A, B, C, and D. Entity Parameters: V max = 40 V I max = 165 ma I max = 225 ma C i = 0 L i = 0 Rosemount 751 1. When connected per Rosemount drawing 01151-0214 (I.S.). K5 Combination of E5 and I5 NEMA Enclosure Type 4X Canadian Standards Association (CSA) approvals Certificate Number: 1718395 E6 Explosion-Proof for Class I, Division 1, Groups C and D; Standards: C22.2 No. 25-1966, C22.2 No. 30-M1986, C22.2 No. 94-M1991, C22.2 No. 142-M1987 Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Dust-Ignition Proof for Class III, Division 1, Groups A, B, C, and D. CSA Enclosure type 4X I6 Intrinsically safe Standards: C22.2 No. 157-1992, C22.2 No. 213-M1987, Class I, Division 1, Groups A, B, C, and D CSA enclosure type 4X 1. When connected per Rosemount drawing 00751-0068 with approved barrier system (I.S.). C6 CSA: Explosion-proof; Intrinsically Safe Combination of E6 and I6 International certifications E7 IECEx Flameproof Certification IECEx DEK 11.0082X Standards: IEC 60079-0:2007, IEC 60079-1:2007 Ex d IIC T5/T6 Gb T5 (-20 C T amb 70 C) T6 (-20 C T amb 40 C) IP66 V max = 60V 1. Transmitters have an NPT cable entry thread; A certified flameproof thread adapter or cable gland must be used to maintain type of protection. Contact manufacturer for flame path dimensions. Cable glands and wiring must be suitable for greater than 80 C. I7 IECEx Intrinsic Safety Certification IECEx BAS 11.0064X 7

Rosemount 751 August 2014 Standards: IEC 60079-0:2007-10, IEC 60079-11:2006 Ex ia IIC T5/T6 Ga T5 (-60 C T amb 80 C) T6 (-60 C T amb 40 C) IP66 Entity Parameters: U i = 60 V I i = 200 ma L i = 0 C i = 0 1. The enclosure is made of aluminum and finished with a protective paint finish; care should be taken to protect it from impact or abrasion when installed in a zone 0 environment. European certifications E8 ATEX Flameproof Certificate Number: DEKRA11ATEX0240X Standards: EN60079-0:2008, EN60079-1:2009, Ex II 2 G Ex d IICT5/T6 Gb T5 (-60 C to 80 C) T6 (-60 C T amb 40 C) IP66 V max = 60 V 1. Transmitters have an NPT cable entry thread; A certified flameproof thread adapter or cable gland must be used to maintain type of protection. Contact manufacturer for flame path dimensions. Cable glands and wiring must be suitable for greater than 80 C. I8 ATEX Intrinsic Safety Certificate Number: Baseefa03ATEX0448X Standards:EN60079-0:2009, EN60079-11:2007 Ex II 1 G Ex ia IIC T5/T6 T5 (-60 C T amb 80 C); T6 (-60 C T amb 40 C) IP66 Input Parameters: U i = 60 V I i = 200 ma L i = 0 C i = 0 1. The enclosure is made of aluminum and finished with a protective paint finish; care should be taken to protect it from impact or abrasion when installed in a zone 0 environment. N1 ATEX Type N Certificate Number: Baseefa03ATEX0454 Standards: EN60079-0:2009, EN60079-15:2010 Ex II 3G Ex na II T6 Gc T6 (-40 ºC T amb 70 ºC) IP66 Rated Voltage = 5 V Technical Regulations Customs Union (EAC) EM, IM, EM, NM Contact an Emerson Process Management representative for additional information Brazilian approvals E2 Brazil INMETRO Flameproof Certificate number: NCC 5486.09X Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC 60079-1:2009 Ex d IIC T6 Gb IP65 Input parameters: U n = 12-45 Vcc U max = 60 Vcc I n = 4-20 ma I max - 666 ma 1. Transmitters have an NPT cable entry thread; A certified flameproof thread adapter or cable gland must be used to maintain type of protection. I2 Brazil INMETRO Intrinsic Safety Certificate number: NCC 7013.10X Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC 60079-11:2009, ABNT NBR IEC 60079-26:2008 Ex ia IIC T5/T6 Ga T5 (-60 C T amb 80 C); T6 (-60 C T amb 40 C) Input Parameters: U i = 60 V I i = 200 ma P i = 2.4 W L i = 0 C i = 0 8

August 2014 Rosemount 751 1. The enclosure is made of aluminum and finished with a protective paint finish; care should be taken to protect it from impact or abrasion when installed in a zone 0 environment. K2 INMETRO: Flameproof; Intrinsic Safety Combination of E2 and I2 Chinese approvals E3 China (NEPSI) Flameproof Certificate Number: GY071011 Standards: GB3836.1-2000, GB3836.2-2000 Ex ia IIC T5/T6 (except acetylene) Ex ia IIC T5/T6 I3 China (NEPSI) Intrinsic Safety Certificate number: GY091234X Standards: GB3836.1-2000, GB3836.4-2000 Ex ia IIC T5/T6 T5 (-60 C T amb 80 C); T6 (-60 C T amb 70 C) Input Parameters: U i = 60 V I i = 200 ma C i = 0 L i = 0 1. The transmitter must be installed to minimize the risk of impact or friction with other metal surfaces. T6 (-20 C T amb 60 C) 1. Transmitters have an NPT cable entry thread; A certified flameproof thread adapter or cable gland must be used to maintain type of protection. Contact manufacturer for flame path dimensions. The earth connection should be connected reliably. 9

Rosemount 751 August 2014 Dimensional Drawings Figure 1. Rosemount 751 Field Signal Indicator F G B D C E H A I J L K N M O A. Terminal Screws B. Housing O-Ring C. Field Wiring Terminals D. Loop Protection Diode E. Mounting Boss (tapped) F. Mounting Bracket (optional) G. Mounting Bolt with Washer H. U-Bolt for 2-In. Pipe I. Cover Clamp J. Housing K. Optional 3/4- to 1/2-In. Conduit Reducing Bushing (if required) L. Meter M. Cover Bushing N. Cover Foam Spacer O. Housing Cover 10

August 2014 Rosemount 751 Figure 2. Rosemount 751 Dimensional Drawing 3.75 (95) 2.8 (71) 4.2 (107) 7.0 (178) 1.0 (25) A A 4.1 (104) 5.0 (127) 6.0 (152) B 1.1 (28) 3.0 (76) 4.0 (102) Dimensions are in inches (millimeters). A. Optional Mounting Bracket B. Permanent Tag C. 0.37 (9.4) Diameter Holes (typically four places) C D E D. FM or CSA Tag (if required) E. 3/4-14 NPT Conduit Connection F. 2-in. Pipe F 11

Rosemount 751 00813-0100-4378 Rev FA Product Data Sheet August 2014 Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 906-8889 Emerson Process Management Blegistrasse 23 P.O. Box 1046 CH 6341 Baar Switzerland T +41 (0) 41 768 6111 F +41 (0) 41 768 6300 Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Signapore 128461 T +65 6777 8211 F +65 6777 0947 Service Support Hotline: +65 6770 8711 Email: Enquiries@AP.EmersonProcess.com Emerson Process Management Latin America 1300 Concord Terrace, Suite 400 Sunrise Florida 33323 USA T + 1 954 846 5030 Standard Terms and Conditions of Sale can be found at \terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. All other marks are the property of their respective owners. 2014 Rosemount Inc. All rights reserved. 00813-0100-4378, Rev FA, 08/14