BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.



Similar documents
Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

12 Volt 30 Amp Digital Solar Charge Controller

3 WATT LED SPOTLIGHT Model No. SLM

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Installation Instructions for Alarm Module Kit A043F059

400 Amp Rechargeable Jump Start System RAC-HP082

Installation and Operating Instructions (for chargers shown below)

Installation and Operating Instructions (for chargers shown below)

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

INSTRUCTION MANUAL MODEL PCD-88

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

3000W Power Inverter

Seven function digital multimeter

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

TELEDYNE BATTERY PRODUCTS. INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL. For

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS. For use with a Power Wheels vehicle that requires a 12-Volt 9.5 Amp/Hr lead acid battery.

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

How To Use A Power Supply Unit (Upu)

CHARGING SYSTEMS INTERNATIONAL

BATTERY CHARGER OWNER S MANUAL

POWER TO GET THE JOB DONE

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Manual. Solar Fountain Mobile Phone Charger

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Ceiling Mount Air Handler Manual

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

About this Manual. Support for Your Product

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

User s Manual AURORA 1.2K/2.2K

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Li Battery Pack & Charger Safety & Operating Instructions

Copyright. Trademarks

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

DiscovR R134a Refrigerant Identifier

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

900 MHz Lightweight Wireless Stereo Headphones

GAS SAFETY PRECAUTIONS

Standard Operating Procedure (SOP) Car/Truck Battery Safety

Alarm Clock USER GUIDE

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

User Manual (English)

Owner s Manual & Safety Instructions

How To Use A Cdm250 Digital Multimeter

ODYSSEY Battery Heavy Duty Diagnostic Tester User Guide

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

120Volt 60-70A ARC WELDER Rev

Owner s Manual. ULTRA-POWER II ACCU-POWER & ACCU-POWER ONBOARD Solid State Fully Automatic Chargers. Manual Number Edition Code 0493B0101A

7 FUNCTION DIGITAL MULTIMETER

ATS Overhead Table Shelf System INSTRUCTION MANUAL

2/8/12 AMP Smart Charger OWNER S MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Owner s Manual & Safety Instructions

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

User s Manual Before using the inverter, you need to read and save the safety instructions.

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

13 Watt PORTABLE SOLAR POWER KIT

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

i410/i1010 AC/DC Current Clamp

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

StorTrends 3400 Hardware Guide for Onsite Support

2013 VTech Printed in China US

B-AIR BLOWER CUB POWER MODEL # CP-1

If you accidentally get battery acid on your skin, flush it with lots of water

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

601 International Ave. Washington, Missouri (636) (636) (FAX) M REV C

User and Installation Guide

Nokia Bluetooth Headset BH-118 User Guide

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

4 in 1 Air Compressor

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Copyright. Trademarks

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

BroadBand PowerShield. User Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Dual Laser InfraRed (IR) Thermometer with Color Alert

Model 1756 Test Lead Kit

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Battery Replacement Instructions First Alert 148 & 168, Vista- 10, Vista- 20, DSC 1555 and DSC 1616 Residential Control Panels. Battery Safety Warning

Wireless Phone Jack System

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

Thermistor Thermometer MODEL NO

HP UPS R1500 Generation 3

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Mini-led spotlight with magnetic base

Transcription:

BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1

UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping damage is present, stop and contact the shipping company for damage claims information. The box should contain the BC-5000 tester, operators instruction manual, battery disconnect (7017-2), and 2 battery adapter cables. IMPORTANT: Save the shipping box and packaging material. They should be used to re-pack the tester if it needs to be shipped back for warranty or service. 2

INTRODUCTION Congratulations on acquiring your new BC-5000 battery capacity tester. The BC-5000 battery capacity tester has been designed to provide the operator with accurate battery capacity testing and ease of operation. The features of the BC-5000 are: - Adjustable constant current load in 1 Ampere increments. (12V battery 10-50Adc; 24V battery 10 to 55Adc) - Powered by the battery on test operation. No AC power required. - LCD display. - 50mv voltage resolution. - Over temperature protection. - Audio warning when capacity test is complete or malfunction of the unit. - 1 year warranty. Before operating your new BC-5000 battery capacity tester, familiarize yourself with this operators manual and the unit. Questions? Email: Support @cofko.com Thank you, COFKO Manual: BC-5000 Revision: C Date: 12/7/11 Copyright: COFKO 2010 3

CONTENTS PAGE BC-5000 HISTORY OF REVISIONS... 5 BC-5000 SAFETY NOTES.. 6, 7 BC-5000 OPERATION..... 8, 9 BC-5000 CARE.... 10 BC-5000 TECHNICAL DATA... 11,12 BC-5000 WARRANTY.... 13 BC-5000 NOTES....... 14 BC-5000 CERTIFICATION OF FACTORY CALIBRATION...... 15 4

HISTORY OF REVISIONS Revision # Effective Date Description of Change Approval By A 03/09/2009 Initial issue M.C. B 05/12/2011 Phone Number Change M.C. C 09/08/2012 Increase C1 current from 50Ahr to 55Ahr for 24V battery M.C. D 12/07/2012 Increase Maximum Operation Altitude from 6000 to 6500 M.C. D 12/07/2012 Change Description of Box Contents M.C 5

SAFETY NOTES Your new BC-5000 battery capacity tester has been designed with operator safety as a function of its design, construction, and operation. Understanding how to safely operate the BC-5000 battery capacity tester is important. Failure to follow the operation and safety guidelines when using the BC-5000 can result in personal injury to the operator and damage to the BC-5000. Always review the battery manufacturer s battery capacity testing guidelines before testing batteries. Look for this symbol to identify Safety and Danger precautions. Be Alert- Your safety is involved! Personal injury or equipment damage can occur if guidelines are not followed. PRECAUTIONS: Precautions: 1 CAUTION: Aircraft batteries are certified to have certain minimum capacity for emergency operations in the event of an electrical generator system failure. Never jump start an aircraft that has a discharged or dead battery. 2 WARNING: ELECTRIC SHOCK HAZARD. Do not touch un-insulated portion of the connector or the battery terminals. A possibility of serious electrical shock exists. 2 WARNING: ELECTRIC SHOCK HAZARD. Do not lay tools or other metal objects on the battery as arcing or explosion could occur. Remove conductive jewelry before working around battery, charger, or test equipment. 3 CAUTION: ELECTRIC BURN HAZARD. Do not wear conductive rings, belt buckles, or other jewelry when working with batteries, chargers, or test equipment. Do not lay tools or other metal objects on the battery as arcing and severe burns could occur. 4 WARNING: Batteries on charge or discharge produce hydrogen gas, which can explode if ignited. Do not smoke, use an open flame, or cause sparking near a battery. Charge, service or test a battery only in a well ventilated area. The use of exhaust fans may reduce the risk of explosion. 5 WARNING: Batteries contain sulfuric acid which will cause burns. DO NOT TOUCH EYES AFTER TOUCHING BATTERY. Do not get acid in your eyes, on your skin, or clothing. In the event of acid in the eyes, flush 6

thoroughly with clean cool water for several minutes. Get professional medical attention. Refer to battery MSDS for additional information. 6 WARNING: Wear proper eye, face and hand protection at all times when working with batteries. Know the location and use of emergency eyewash and a shower nearest the battery charging area. 7 CAUTION: To prevent damage to the connector, arc burns, or explosion, batteries should never be connected or disconnected while being charged or discharged. Batteries must be connected or disconnected only when the circuit is open. Insure the aircraft battery switch, external power source, or the charger/analyzer is in the OFF position before connecting or disconnecting the battery. Battery terminal protectors should be installed whenever the battery is not connected in the aircraft or to the test equipment. 8 CAUTION: Batteries contain hazardous materials. Know the location and proper use of emergency response materials. Refer to battery Material Safety Data Sheet (MSDS) for additional information. 9 Caution / Warning: Only constant potential charging may be done on the aircraft. DO NOT constant current charge a battery on the aircraft. There could be a serious risk of injury to personnel and / or damage to the aircraft or aircraft systems due to high voltage and generation of explosive gases when charging constant current. 10 DANGER: Never connect or disconnect BC-5000 tester main power connector with the switch on. Connecting or disconnecting the BC-5000 tester with discharge current applied can cause a spark and possible battery explosion. 11 DANGER: Never capacity test batteries without first inspecting all battery wires and connections for condition and tightness. Replace all defective wires and bad connections before capacity testing batteries. Defective wiring and bad connections can cause overheating during a capacity test. 12 DANGER: never connect the BC-5000 capacity tester to batteries with voltage or capacity currents outside the ratings of the tester. The BC-5000 tester is designed for 12 and 24 volt batteries. Connecting the tester to batteries with different voltages can permanently damage the tester and endanger the operator. Any questions that arise about the battery or tester ratings, Email: Support@cofko.com 13 DANGER: never obstruct the BC-5000 tester air intake or hot air exhaust openings. Obstructing either opening can cause the tester to overheat. 7

BC-5000 OPERATION NOTE: Before capacity testing a battery, review all testing procedures as required by the battery manufacturer. Failure to do so can result in inaccurate test date. NOTE: Before capacity testing a battery, RECHARGE THE BATTERY FOLLOWING THE MANUFACTURER S RECHARGING GUIDELINES. 1. Make sure the switch is off before connecting the BC-5000 to the battery to be capacity tested. DANGER: Never attempt to connect the BC-5000 capacity tester to a battery using anything but the proper connector. Doing so can damage the tester, battery, or cause injury to the operator. Capacity testing data will be invalid if incorrect connections are made. 2. Place the OFF/ON power switch to the ON position. The BC-5000 LCD display will flash tester model and software version. 3. Select the correct battery voltage 12 or 24 by pressing the UP or DOWN button located to the right of the display. Pressing the DOWN button will change battery testing voltage to 12 volts. NOTE: If incorrect battery voltage is selected the BC-5000 will show the display below. 4. To select the battery manufacturer s C1 (one hour) battery discharge amperage rate, press the NEXT button located on the left side of the display. To adjust the C1 amperage test rate, press the UP or DOWN buttons. 5. Press the NEXT button to display the start test menu. 8

6. To start the test, press the NEXT button again. If you wish to stop the test before the End Point Voltage (EPV) is reached, press the NEXT button and the BC-5000 will stop testing. If testing is stopped before EPV is reached the battery must be recharged following the battery manufacturer ss recharge procedures before retesting. 7. After pressing the NEXT button to start the test, the BC-5000 cooling fan motor will start and the LCD display will show the C1% reading, battery voltage, flash TESTING, and test amperage. If the BC-5000 COOLING FAN MOTOR FAILS TO START press the NEXT button stopping the test. Place the OFF/ON switch to the OFF position and return the BC-5000 for service. 8. Upon reaching the EPV the BC-5000 test will stop. The cooling fan motor will stop and the audio warning beeper will beep. The display will show C1% battery capacity. Test amperage and Pass or Failed is displayed. Passing is based upon a battery capacity of 85% or greater of its C1 rating. Failing is a battery with less than 85% of its C1 rating. 9. Record test data, then place the Power OFF/ON switch to the OFF position. Disconnect the BC-5000 power connector from the battery. NOTE: When the POWER switch is set to the OFF position or the BC-5000 is disconnected from the battery, all test data will be lost. 10. Before returning the battery to service follow the battery manufacturer s recharging procedure. REMEMBER SAFETY FIRST! 9

BC-5000 CARE Your BC-5000 battery capacity tester should be treated as precision test equipment, misuse will shorten its ability to perform accurate battery testing. Some simple guidelines of care will insure years of trouble free operation. 1. Do not drop the BC-5000 or expose it to rough handling. 2. Do not expose the BC-5000 to water or fluids of any kind. 3. Do not operate the BC-5000 in a closed up area. 4. Do not connect the BC-5000 to batteries of improper voltage ratings. 5. Do not operate the BC-5000 with the air intake or exhaust outlet blocked or restricted. 6. Do not carry the BC-5000 by the main power cable. 7. Do not operate the BC-5000 near flammable materials. 8. Do not expose the BC-5000 to direct sunlight during operation. 9. Do not expose the BC- 5000 to any other heat sources. 10. Always call the technical support line for questions on BC-5000 safety and operation. REMEMBER SAFETY FIRST! 10

TECHNICAL DATA BC-5000 SPECIFICATION: Maximum Battery Input Voltage...... 28.0VDC Minimum Battery Input Voltage....... 9.0VDC Maximum Operating Altitude 1...... 6500ft(1981.2m) End Point Voltage (EPV) 2 12V Battery EPV....... 10VDC IEC 24V Battery EPV.... 20VDC IEC Constant Current Load..... 12 Volt Battery 10 to 50Adc 1A steps(+/- 0.5ADC)... 24 Volt Battery 10 to 55Adc 1A steps(+/- 0.5ADC) Test Operational Temperature 3...... 59 F or higher Case Length...... 12 in(304.8mm) Case Width....... 9 in(228.6mm) 11

Case Height..... 10 in(254mm) Weight...... 10 lbs(4.5kg) Operation Temperature Range...-20 to 50 Deg. C 1. Consult factory for testing above maximum altitude rating. 2. Consult battery manufacturer for End Point Voltage (EPV). 3. Based upon 24 hour battery temperature stabilization in a 59 F or higher environment before capacity testing battery. Consult battery manufacturer for capacity testing at higher or lower temperatures. 12

LIMITED WARRANTY STATEMENT OF WARRANTY COFKO ELECTRONICS warrants to the original purchaser(end user) of the BC-5000 battery capacity tester that it will be free of defects in workmanship and materials. This warranty is void if COFKO ELECTRONICS finds that the BC-5000 battery capacity tester has been subjected to improper care, abnormal operation, or modification. WARRANTY PERIOD: The warranty period covers the original purchaser (end user) from the date of shipping. 1 Year: Covers each BC-5000 battery capacity tester for workmanship, material, and labor. TO OBTAIN WARRANTY COVERAGE: You are required to notify COFKO ELECTRONICS, of any defects within the warranty period. Written notification is recommended. WARRANTY REPAIRS: If upon inspection COFKO ELECTRONICS confirms the existence of a defect covered by this warranty, the defect will be corrected by repair or replacement at COFKO ELECTRONICS option. WARRANTY COST: The purchaser must bear the cost of shipping the BC-5000 to COFKO ELECTRONICS as well as the return shipping cost. IMPORTANT WARRANTY LIMITATIONS: 1. COFKO ELECTRONICS will not accept responsibility for repairs made without authorization. 2. COFKO ELECTRONICS shall not be liable for consequential damages (such as lost business, etc.) caused by a defect or reasonable delay in correcting a defect to the BC-5000 battery capacity tester. 3. COFKO ELECTRONICS liability under this warranty shall not exceed the cost of correcting the defective BC- 5000 battery capacity tester. 4. This written warranty is the only expressed warranty covering the BC-5000 battery capacity tester. All warranties implied by law such as Warranty of Merchantability are limited to the duration of this limited warranty of the BC-5000 battery capacity tester. Check your local legal rights for further rights you may have. 13

BC-5000 NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 14

COFKO ELECTRONICS 5517 RIVERVIEW DR. RIVERSIDE, CA. 92509 WWW.COFKO.COM CERTIFICATION OF FACTORY CALIBRATION EQUIPMENT: MODEL#: BATTERY CAPACITY TESTER BC-5000 Application : Automatic battery capacity tester for 12/24 volt Lead-Acid aircraft batteries with C1 test ratings between 10 to 55 ampere-hour. Specification: Powered by Test Battery. Operation Voltage Range : 9-28Vdc Operator Selected Battery Voltage: 12-24Vdc Operator Selected C1 amperage level: 10-55Adc(12V battery 10 to 50A ; 24V battery 10 to 55A) One Amp Operator Selected Test Amperage Steps. (16X2) LCD Information Display. Displayed Voltage Resolution 50mv Cutoff Voltage 12V Battery 10.00Vdc (IEC 60952-1) +/-100mv Cutoff Voltage 24V Battery 20.00Vdc (IEC 60952-1) +/-100mv Displayed Battery Capacity (C1) Percent % Displayed Pass or Fail Battery Condition Notes: Calibrated with NIST traceable equipment. Test Equipment Manufacturer: Model: Serial# Control# Volt Meter #1 HP 3456A 2015A01818 12617 Volt Meter #2 HP 3455A 1622A11888 12618 Frequency Counter HP 5316A 2632A10545 12693 Shunt Deltec WB100 100 NA. 12619 Product: Model: Calibration Due: Shipped Condition: Procedure: Automatic Battery Capacity Tester BC-5000 Once A Year Calibrated within Specified Tolerance - Passed CF1_FINALCAL COFKO ELECTRONICS CERTIFIES THAT THE ABOVE LISTED TEST EQUIPMENT MEETS OR EXCEEDS ALL SPECIFIED TOLERANCES. THE TESTER STATED ABOVE HAS BEEN CALIBRATED WITH NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY(NIST) TRACEABLE EQUIPMENT LISTED ABOVE. DATE MANUFACTURED: / / S/N: 1 SIGNATURE: ----------------------------------------------------------------------------------------------------------------------------------------------------------------------- Date of First Use: / / Signature: 1. BC-5000 serial number location- Bottom of Case. 15