User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01)



Similar documents
BNC, N, TNC Connectors

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

ULTIMATE SNAP-N-SEAL

Termination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D , D

INSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX

Balun Bulletin- CCTV Systems- Termination

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

Reasons for reissue are in Section 6, REVISION SUMMARY.

SPIR-110: U of S RG174 Cable Assembly for CAEN 792AA QDC

How to choose the very best connectors for your speaker cables and enjoy superb sound from your music system

A better way to install PL-259 connectors on RG-8X type coax Dan Richardson, K6MHE

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Connecting the Channel A

Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

Bill Conkling July 2012

Position Cat5e (EMT) Modular Plug Connectors. Application Specification

SMA Series Subminiature RF Connectors

POWERPOLE CONNECTOR GENERAL INSTALLATION TIPS

LED Wiring and Connections

Name: Bicycle Cellphone Charger Circuit Assembly Manual Device: Nokia/Blackberry List of Components:

MDU SC Connector Termination Procedure

Coaxial Cable Performance and Application Guide

Anderson Powerpoles. Powerpole Assembly Instructions for SCOUT, NAVIGATOR AND RANGER ROV s

Directory chapter 04

TELECOM The Newsmagazine of the Industrial Telecommunications Association, Inc.

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

Assembly Guide FOR LED NEON FLEX

MT-RJ Connectors Termination Procedure

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

AMPSEAL* Automotive Plug Connector and Header Assembly

T.V. & VIDEO CONNECTORS

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house

Figure 1-A This end of the cable is the side that will be plugged into the power adapter and DVR Card.

Data Highway/Data Highway Plus/ Data Highway II/Data Highway 485 Cable Installation Manual

Replacing a Faulty Hall Sensor* Cable (Cause of No-Start)

COAXICON Contacts. RF Coax Connectors. Product Facts

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

Standards Affecting a Premise T-1 Installation

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

System Wiring Design Guide

ATL Fuel Level Sender Probes

with installation dynafact boost GAUGE this manual is for use with systems

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

SMA Connectors. RF Coax Connectors. Product Facts

Cabling Specifications

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

Malibu Monte Carlo El Camino

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

I Click on a link tab to jump to that page. Cover Page

RS232/DB9 An RS232 to TTL Level Converter

IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide

Times Microwave Systems Hermetically Sealed Assemblies

Quick Connect Boxes Inside Gloveboxes

PARTS & INSTALLATION INSTRUCTIONS MEYER SNOW PLOW LIGHTS

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

DIRECTCONNECT SERVICE

2 Meter Half-Wave J-Pole Antenna From 450 Ohm Ladder Line

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

Operating Instructions

HARAX circular connector

I NTERFACE CABLE ADAPTER MODULE

RF cables. Edition 2015

EH-20 20m antenna. By VE3RGW

Assembly and User Guide

KTM AC to DC Stator Conversion Instructions (Floating the ground)

TECHNICAL GUIDE. For Self-Shielded Guns - 300, 400 and 500 amp SAFETY AND WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA OPTIONS

How To Power A 12 Volt Relay On A Car Or Truck

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

Cover Page. Factory Radio Other Documents Available For This Vehicle:

Rural Training Center-Thailand: EmComm Paper Simple Coax Testing 2011, All rights reserved.

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Build- It- Yourself: So2ware Oscilloscope and Func:on Generator

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

Assembly Instructions: Shortwave Radio Kit

" EXCEEDING EXPECTATIONS WITH PERFORMANCE "

Installation & Weatherproofing Guide for ENCOM Broadband Radios

Nevco, Inc. Installation Manual

Time needed: ~3h for lid replacement only. Add 1h for operation harness in lid and ~2h more for installing drive unit and cable harness in trunk.

NELSON HEAT TRACING SYSTEMS

INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION.

Fakra. Coaxial connectors. DC 6 GHz

SC, FC and ST * Hot Melt Fiber Optic Connectors

The range of rail-mounted terminal blocks. for a perfect electrical installation.

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Advantium 2 Plus Alarm

FREEBIRD THE ORIGINAL D.I.Y. ORNITHOPTER! Tools and Glue. Required Materials

Discover. TIMES MICROWAVE SYSTEMS A Smiths Industries company

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

Our full line of JS Popper test products enables you to monitor circuits without taking them offline

Using and Wiring Light Emitting Diodes (LEDs) for Model Railroads

CUSTOM AUXILIARY FORWARD LIGHTING KIT

3M Scotchcast Mine and Portable Cable Splice Kit

LOW LOSS CABLE PAG. 1

Transcription:

User s Manual BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01)

BNC Termination Kit Instructions This document is a compilation of Extron s instructions, together with copies of AMP Instruction booklets that are provided with each of the AMP tools included in this kit. 1 Extron Mini-High-Res Cable-to-BNC Instructions Parts included in Kit Pre-cut Heat shrink insulation: Red 3/8 diameter Green 3/8 diameter Blue 3/8 diameter Yellow 3/8 diameter Black 3/8 diameter 3 AMP Coaxial Cable Stripper Instructions (4100-0632) 5 AMP 75-Ohm BNC Plug Instructions (408-9088) Parts included in Kit BNC connectors for cable ends: Male plug bodies Center contacts Tube for insulation Step-down Ferrule 7 AMP Pro-Crimper II Hand Tool & Die Assembly Instructions (408-4218) 8 AMP Pro-Crimper II Hand Tool Application & Maintenance (408-9930) 89-04 68-197-02 Rev. B Written & printed in USA 10 AMP Series BNC Solder Receptacle Jacks (IS 2858)

Introduction Use these instructions to install BNC connectors on Extron s 75 ohm Super High- Resolution coax cable. The kit includes the following required tools: AMP Coaxial Cable Stripper AMP Pro-Crimper (with dies to crimp both center contacts and the ferrules) Wire Cutters/Strippers Before using each of the AMP tools, go to the appropriate section of this document for instructions. Cable-Stripping Procedure Use the AMP Coaxial Cable Stripper and the copy of the instruction sheet provided on pages 3 and 4 to make the three-step strip. One blade cuts the outer jacket, the next one cuts the jacket and wire braid and the third blade cuts the jacket, the wire braid and the insulation (dielectric). It may be necessary to try some sample cuts and adjust the tool to get the proper depth for each cut. Installation Procedure Use the illustration to the right to identify the cable parts and dimensions of each cut. When the cable has been stripped and ready to install the BNC connector, use the illustration on the facing page and these steps as a guide for installing the connector. Additional instructions can be found on pages 5 and 6. 1. Identify the parts required. Cut 1.5 inches of the chosen colored heat shrink insulator and slip it over the cable far enough to be out of the way of other components. 2. Slide the small end of the ferrule over the cable, pushing it back from the end. (The large end will go toward the BNC connector.) Slide the plastic tube over the insulating dielectric, but under the wire braid. When finished, the wire braid will make contact with BNC body, but NOT with the center conductor. (The braid may appear to be bare wire strands.) 3. Push the center contact over the center conductor. When the center conductor slides all the way into the hole, it should no longer be exposed. 4. Use the AMP Pro-Crimper tool to crimp the center contact onto the conductor. Check that the connection is secure. (Detailed instructions for using this tool are included on pages 5 and 6.) 5. Push the plug body over the center contact and over the dielectric insulator with the plastic sleeve inside the wire braid. 6. Push the ferrule against the plug body. It should cover the exposed wire braid and part of the outside insulation. 7. Crimp the ferrule in place. Trim any exposed wire braid if necessary. 8. Slide the Color-Coded Heat Shrink sleeve toward the connector, covering the Ferrule. Use a heat source to shrink the sleeve tightly in place. Repeat this procedure for each BNC cable connector. When fully inserted, the center contact should extend into the plug body, as shown at the bottom of the next page. The illustration to the right shows the parts of the coaxial cable, with the Ferrule and Tube added. BNC Connector Installation 1 Extron 75 Ohm BNC Termination Kit User s Guide

Extron 75 Ohm BNC Termination Kit User s Guide 2

Mini coax 3 Extron 75 Ohm BNC Termination Kit User s Guide

If setup is required, use RG174 side of the red gauge block. Mini Hi-Res Extron 75 Ohm BNC Termination Kit User s Guide 4

5 Extron 75 Ohm BNC Termination Kit User s Guide

Extron 75 Ohm BNC Termination Kit User s Guide 6

7 Extron 75 Ohm BNC Termination Kit User s Guide

Warning: The die retaining pins must be in place or the connector may skew and jam. Extron 75 Ohm BNC Termination Kit User s Guide 8

9 Extron 75 Ohm BNC Termination Kit User s Guide

Extron 75 Ohm BNC Termination Kit User s Guide 10

BNC Connector Installation 11 Extron 75 Ohm BNC Termination Kit User s Guide