Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description



Similar documents
Sprinkler Identification Numbers

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Model/Sprinkler Identification Numbers

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Sprinkler Identification Numbers (SINs) Technical Data

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model KFR56 Series Quick Response Standard Spray

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Quick response concealed horizontal sidewall sprinkler

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

Model F1FR Series Quick Response Glass Bulb Sprinklers

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

esfr pendent sprinkler vk510 (k25.2)

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

Viking Residential Sprinkler Installation Guide

Sprinkler Guards Model C Model D

Technical Data. Installation

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the

Extended Coverage Sprinklers

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

Price Book - Section 20 Miscellaneous

Submersion/Insertion Toroidal Sensor

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

Toroidal Conductivity Sensor

Viking Residential Sprinkler Installation Guide

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Antifreeze Solutions in Residential Fire Sprinkler Systems

Select Radiators Installation Guide

Stainless Steel Single and Dual Circulation Kits

TECHNICAL DATA. Dry 122a. November 12, 2013

HIGH VELOCITY WATER SPRAY NOZZLE

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Easy Tool Retracting System CMC-SR2159ER36

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

! WARNING. Before using product, read and understand instructions.

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Your safety and the safety of others are very important.

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Engineering Specifications

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

James M. Pleasants Company

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

MODEL J SERIES CONVERTER

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

PGL5/6 - Parking Garage Luminaire Installation Instructions

Fighting Fire in Sprinklered Buildings. Student Guide

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Submersion/Insertion Toroidal Sensor

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

Installer s Guide 18-AH39D1-13

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

INSTALLATION INSTRUCTIONS BL-8704

Grade Level Spill Containment Manholes

INSTALLATION INSTRUCTIONS MK-8704

Float and Thermostatic Traps Series H, C and X

Installation Instructions

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

08.08 Vic-Check Valves

Wet alarm valves. Wet alarm valves. FM trim

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

5800 Temperature Sensor Cable Assembly

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

The cylinder head bolts tightening stages have been updated as listed in Table 1.

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

LPM-06 CONVERSION KIT

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

BOWIE PUMPS OPERATION - MAINTENANCE

Transcription:

Worldwide Contacts www.tyco-fire.com Series 2.8,.2,.6, 8.0 K-Factor Upright, Pendent, Recessed Pendent Sprinklers Quick Response, Stard Coverage General Description The TYCO Series, 2.8,.2,.6, 8.0 K-factor, Upright, Pendent, Recessed Pendent Sprinklers described in this data sheet are quick response, stard coverage, decorative mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls. The recessed version of the Series Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 0 (/ inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to / inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 0 (/ inch NPT) Recessed Escutcheon with 1/ inch (6, mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to hling installation of sprinkler systems components. Improper hling installation can permanently damage a sprinkler system or its components cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. when exposed to corrosive atmospheres. Although corrosion-resistant coated sprinklers have passed the stard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series Pendent Sprinklers is detailed in Technical Data Sheet TFP6, Sprinkler Guards are detailed in Technical Data Sheet TFP780. NOTICE The Series, 2.8,.2,.6, 8.0 K-factor, Upright, Pendent, Recessed Pendent Sprinklers described herein must be installed maintained in compliance with this document with the applicable stards of the National Fire Protection Association, in addition to the stards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY111 - Upright 2.8K, 1/2 NPT TY121 - Pendent 2.8K, 1/2 NPT TY211 - Upright.2K, 1/2 NPT TY221 - Pendent.2K, 1/2 NPT TY11 - Upright.6K, 1/2 NPT TY21 - Pendent.6K, 1/2 NPT TY11 - Upright 8.0K, / NPT TY21 - Pendent 8.0K, / NPT TY81 - Upright 8.0K, 1/2 NPT TY91 - Pendent 8.0K, 1/2 NPT Page 1 of 10 NOVEMBER 201 TFP171

Page 2 of 10 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. ESCUTCHEON SEATING 1 - Frame 2 - Button - Sealing - Compression Assembly Screw - Bulb 6 - Deflector * 7 - Bushing 7 7/16" (11,1 mm) NOMINAL MAKE-IN 2-/16" 1-9/16" (9,7 mm) 2-1/" 1/2" NPT** STYLE 10 or 20 2-7/8" DIA. FLATS ESCUTCHEON CROSS SECTION FIGURE 1 QUICK RESPONSE (TY111) AND (TY121) S 2.8 K-FACTOR, 1/2 INCH NPT 1 2 6 * * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. ESCUTCHEON SEATING 1-2 - Frame Button - Sealing - Compression Assembly Screw - Bulb 6 - Deflector * 1 7/16" (11,1 mm) NOMINAL MAKE-IN 2-/16" 1-1/2" (8,1 mm) 2-/16" 2 1/2" NPT** STYLE 10 or 20 2-7/8" DIA. FLATS ESCUTCHEON CROSS SECTION FIGURE 2 QUICK RESPONSE (TY211) AND (TY221) S.2 K-FACTOR, 1/2 INCH NPT 6 * * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. ESCUTCHEON SEATING 1 - Frame 2 - Button - Sealing - Compression Assembly Screw - Bulb 6 - Deflector * 1 7/16" (11,1 mm) NOMINAL MAKE-IN 2-/16" 1-1/2" (8,1 mm) 2-/16" 2 1/2" NPT** STYLE 10 or 20 2-7/8" DIA. FLATS ESCUTCHEON CROSS SECTION FIGURE QUICK RESPONSE (TY11) AND (TY21) S.6 K-FACTOR, 1/2 INCH NPT 6*

Page of 10 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. ESCUTCHEON SEATING 1 - Frame 2 - Button - Sealing - Compression Assembly Screw - Bulb 6 - Deflector * 1 1/2" (12,7 mm) NOMINAL MAKE-IN 2-1/" 1-9/16" (9,7 mm) 2-/16" (8,7 mm) 2 /" NPT** STYLE 0 or 0 2-7/8" DIA. FLATS ESCUTCHEON CROSS SECTION FIGURE QUICK RESPONSE (TY11) AND (TY21) S 8.0 K-FACTOR, / INCH NPT 6 * 1/2" NPT ** 7/16" (11,1 mm) NOMINAL MAKE-IN 2-/16" FLATS CEILING SEATING 1-9/16" (9,7 mm) 2-1/" CROSS SECTION 1 2 6 * 1 - Frame 2 - Button - Sealing Assembly - Bulb * ** - Compression Screw 6 - Deflector * Temperature rating is indicated on Deflector. Pipe thread connections per ISO 7-1 can be provided on special request. FIGURE QUICK RESPONSE (TY81) AND (TY91) S 8.0 K-FACTOR, 1/2 INCH NPT RECESS (END "A" USED FOR 1/2" NPT MODELS) RECESS RECESS (END "B" USED FOR /" NPT MODELS) FIGURE 6 W-TYPE 6 PUSH IN TO ENSURE ENGAGEMENT WITH ING AREA FIGURE 7 W-TYPE 7

Page of 10 Technical Data Approvals UL C-UL Listed FM, LPCB, NYC Approved Refer to Table A B for complete approval information including corrosionresistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 gpm/psi ½ (0, lpm/bar ½ ) K=.2 gpm/psi ½ (60, lpm/bar ½ ) K=.6 gpm/psi ½ (80,6 lpm/bar ½ ) K=8.0 gpm/psi ½ (11,2 lpm/bar ½ ) Temperature Rating Refer to Table A B. Finishes Sprinkler: Refer to Table D. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame............................Bronze Button...................... Brass/Copper Sealing Assembly..Beryllium Nickel w/teflon Bulb............................... Glass Compression Screw.................Bronze Deflector................... Copper/Bronze Bushing (K=2.8).....................Bronze Operation The glass bulb contains a fluid that exps when exposed to heat. When the rated temperature is reached, the fluid exps sufficiently to shatter the glass bulb, allowing the sprinkler to activate water to flow. Design Criteria The TYCO Series, 2.8,.2,.6, 8.0 K-factor, Upright, Pendent, Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 1, FM Approval is based on the requirements of FM s Loss Prevention Data Sheets). Only the Style 10, 20, 0, or 0 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series, 2.8,.2,.6, 8.0 K-factor, Upright, Pendent, Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1 F (7 C) /2 inch (2, mm) for the 286 F (11 C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 1 ft.-lbs. (9, to 19,0 Nm). A leak tight / inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.- lbs. (1, to 26,8 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutcheon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series Upright Pendent Sprinklers The Series Pendent Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, htighten the sprinkler into the sprinkler fitting. Step. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 6). With reference to Figures 1 through, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series Recessed Pendent Sprinklers The Series Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. After installing the Style 10, 20, 0, or 0 Mounting Plate, as applicable, over the sprinkler threads with pipe-thread sealant applied to the pipe threads, h-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 7). With reference to Figures 1 to, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation finishing, slide on the Style 10, 20, 0, or 0 Closure over the Series Sprinkler push the Closure over the Mounting Plate until its flange comes in contact with the ceiling.

Page of 10 FINISH (See Note ) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME D POLYESTER*** (TY121) (TY111) 1, 2,, 2.8 (TY121)* Figure 8 (TY121)** Figure 9 1, 2, (TY221) (TY211).2 (TY221)* Figure 10 1, 2 (TY221)** Figure 11 NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers.. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.. Approved by the City of New York under MEA -01-E.. Where Polyester Coated Sprinklers are noted to be UL C-UL Listed, the sprinklers are UL C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10 () or Style 0 (/ NPT) / Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 () or Style 0 (/ NPT) 1/2 Total Adjustment Recessed Escutcheon, as applicable. *** Frame Deflector only. N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND.2 K-FACTOR S

Page 6 of 10 FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME D POLYESTER*** LEAD COATED (TY21) (TY11) 1, 2,,,, 6, 7 1, 2,,.6 (TY21)* Figure 12 1, 2,, N/A (TY21)** Figure 1 1, 2,,, N/A (TY21) (TY11) 1, 2,,,, 6, 7 1, 2, 8.0 / NPT (TY21)* Figure 1 1, 2, N/A (TY21)** Figure 1 1, 2,, N/A 8.0 (TY91) (TY81) 1, 2,,, 6 1, 2, NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers.. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/0) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers.. Approved by the City of New York under MEA -01-E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherls, Tel. 1--28-/Fax 1--28-77.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 09a/06) as Quick Response Sprinklers. 8. Where Polyester Coated Lead-Coated Sprinklers are noted to be UL C-UL Listed, the sprinklers are UL C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 () or Style 0 (/ NPT) / Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 () or Style 0 (/ NPT) 1/2 Total Adjustment Recessed Escutcheon, as applicable. *** Frame Deflector only. N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR.6 AND 8.0 K-FACTOR S

Page 7 of 10 FINISH K FACTOR TYPE NATURAL BRASS CHROME D POLYESTER LEAD COATED 2.8 (TY121) (TY111) (TY121) 17 PSI (12,1 BAR) N/A.2 (TY221) (TY211) (TY221) 17 PSI (12,1 BAR) N/A.6 (TY21) (TY11) 20 PSI (17,2 BAR) OR 17 PSI (12,1 BAR) (SEE NOTE 1) (TY21) 8.0 / NPT (TY21) (TY11) (TY21) 17 PSI (12,1 BAR) 17 PSI (12,1 BAR) N/A 8.0 (TY91) (TY81) 17 PSI (12,1 BAR) 17 PSI (12,1 BAR) NOTES: 1. The maximum working pressure of 20 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL);, the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE Care Maintenance The TYCO Series must be maintained serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, maintenance of their fire protection system devices in compliance with this document, as well as with the applicable stards of the National Fire Protection Association (e.g., NFPA 2), in addition to the stards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, maintained by a qualified Inspection Service in accordance with local requirements /or national codes. Care must be exercised to avoid damage to the sprinklers -before, during, after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial frequent visual inspections of rom samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 2 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprinkler condition the long-term integrity of the corrosion-resistant material, which can be affected by the corrosive conditions present.

Page 8 of 10 /8±1/" (1,9±6, mm) 1/2± (12,7±,2 mm) 1/2" (12,7 mm) 1-/16" (, mm) 1/16" (20,6 mm) FIGURE 8 WITH TWO-PIECE / INCH TOTAL ADJUSTMENT STYLE 10 ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 1-/16" (, mm) 1-1/16" (27,0 mm) FIGURE 9 WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT /8±1/" (1,9±6, mm) 1/2± (12,7±,2 mm) 1/2" (12,7 mm) 1-1/" (1,8 mm) FIGURE 10 WITH TWO-PIECE / INCH TOTAL ADJUSTMENT STYLE 10 ESCUTCHEON.2 K-FACTOR, 1/2 INCH NPT 1-1/" (1,8 mm) 1" (2, mm) FIGURE 11 WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 ESCUTCHEON.2 K-FACTOR, 1/2 INCH NPT

Page 9 of 10 /8±1/" (1,9±6, mm) 1/2± (12,7±,2 mm) 1/2" (12,7 mm) 1-1/" (1,8 mm) FIGURE 12 WITH TWO-PIECE / INCH TOTAL ADJUSTMENT STYLE 10 ESCUTCHEON.6 K-FACTOR, 1/2 INCH NPT 1-1/" (1,8 mm) 1" (2, mm) FIGURE 1 WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 ESCUTCHEON.6 K-FACTOR, 1/2 INCH NPT /8±1/" (1,9±6, mm) 1/2± (12,7±,2 mm) 1/2" (12,7 mm) 1-/16" (, mm) 1/16" (20,6 mm) FIGURE 1 WITH TWO-PIECE / INCH TOTAL ADJUSTMENT STYLE 0 ESCUTCHEON 8.0 K-FACTOR, / INCH NPT 1-/16" (, mm) 1-1/16" (27,0 mm) FIGURE 1 WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 0 ESCUTCHEON 8.0 K-FACTOR, / INCH NPT

Page 10 of 10 P/N 7 XXX X XXX SIN FINISH TEMPERATURE RATINGS 0 2.8K (1/2 NPT) TY111 1 NATURAL BRASS 1 1 F (7 C) 1 2.8K (1/2 NPT) TY121 PURE WHITE POLYESTER (RAL9010) 1 1 1 F (68 C) 0.2K (1/2 NPT) TY211 SIGNAL WHITE POLYESTER (RAL900) 17 17 F (79 C) 1.2K (1/2 NPT) TY221 JET BLACK POLYESTER (RAL900) 2 200 200 F (9 C) 70.6K (1/2 NPT) TY11 71.6K (1/2 NPT) TY21 7 LEAD COATED 9 CHROME D 286 286 F (11 C) 90 8.0K (/ NPT) TY11 91 8.0K (/ NPT) TY21 NOTES: 1. Eastern Hemisphere sales only. 2. Available in only 2.8K,.2K, 8.0K, 1 F (68 C) 200 F (9 C); requires lead time to manufacture. 60 8.0K (1/2 NPT) TY81* 61 8.0K (1/2 NPT) TY91* TABLE D AND S PART NUMBER SELECTION Limited Warranty For warranty terms conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 0, or 0) Recessed Escutcheon with (specify*) finish, P/N (specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 6-000-6-87 Specify: W-Type 7 Sprinkler Wrench, P/N 6-80--001 * Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 100 Pennbrook Parkway, Lansdale, PA 196 Telephone +1-21-62-0700 Copyright 201 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation.