Print Head Recovery Quick Guide with Print Head Doctor 7



Similar documents
FILLING AND PURGING THE SYSTEM

Removing a Clog. Before you begin:

Backflush filter R8-30W

All About Your Peripherally Inserted Central Catheter (PICC)

Injector Max Machine

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

TRAINING BULLETIN Fire Apparatus Pump Test

Standard Hydraulic Piping Flushing Procedure

MODEL G300 BRAKE BLEEDER

93052/1115-V05. C260 User Manual

WIKA INSTRUMENT CORPORATION

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

How to care for a Midline Catheter

Ultrasonic Jewelry Cleaner. SI414 Instructions CONTAINS IMPORTANT SAFETY INFORMATION READ AND SAVE THESE INSTRUCTIONS MAX FILL MIN FILL

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

Inline Chlorinator Chlorine Chemical Feeder

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

Cooling system components, removing and installing

Caring for Your PleurX Pleural Catheter

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Introduction. Concept. Advantages PRIMING OF BEARINGLESS PUMP SYSTEMS

Winterizing Your Trailer and Storage Ideas

SunMaxx Solar Filling Station Operating Instructions

Industrial Strength Rocket Launcher

Introduction. Inkjet Technology Explained

- 2 - IMPORTANT SAFETY REMINDERS

Rexroth Hydraulic Pump A10VO Series User Manual

National- Spencer Inc.

Peripherally Inserted Central Catheter (PICC) Patient Instructions

BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.

(Always POWER DOWN printer and UNPLUG before doing any repair work)

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH

How Ground/Water Source Heat Pumps Work

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Gastrostomy Feeding CARE GUIDELINES FOR PATIENTS & CARERS. Accessory items. Freka UK Funnel Adapter. Fixation Plate CH9. Male Luer Lock Adapter

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

15CI and 25CI Reversing Motor Pumpset Owner's Manual

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

Trouble Shooting. Pump

GJ TUBE (GASTROJEJUNOSTOMY TUBE) Daily Care

Removing Moisture within Large Double Glazed Windows

B150 Series Commercial Brewer. Direct Plumb Kit

Extraction: Separation of Acidic Substances

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

Cooling system components, servicing

Record Cleaning Machine

SOLSTICETM International Leisure Products, Inc. 191 Rodeo Drive Edgewood, NY Tel (631)

PAPER CHROMATOGRAPHY

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Underwater Housing for Sony RX100 III, RX100 IV

Flushing and Cleaning the A/C System

Accurate Air Flow Measurement in Electronics Cooling

Ink Bag Solution for Seiko/HP9000 Installation and Operation Manual

DURAS INFLATABLE BOAT OWNER'S MANUAL

DENTAL CHAIR AND UNIT SP- CIELA IMPORTANT

Epson Stylus Pro 7900/9900 QUICK REFERENCE GUIDE

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Auxiliary Rams USERS MANUAL

CO-10 COOLING SYSTEM. Page DESCRIPTION TROUBLESHOOTING CHECK AND REPLACEMENT OF ENGINE COOLANT

ACCUMULATOR INSTALLATION

Continuous ink supply system (CISS) For printer EPSON C65/ C67C64 C63/C68/C88/D68/D88/C87

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Lab Activity on Air Pressure, Wind and Air Circulation Caused by Heating of the Atmosphere

PBX Series Quick Fit Connector Bimetallic Steam Traps

Peasouper Operator s Manual

Procenter Delivery System* Troubleshooting Charts

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Why use Tigerloop in fuel heating systems?

Parker Hannifin Corporation Process Advanced Filtration Division 2340 Eastman Avenue Oxnard, California USA

FLUSHOMETER - TANK SYSTEM

123 Industrial Loop Road Paynesville, MN Phone:

AIR LINE VALVES AND GAUGES

Model MS-41BP 4G/ 15L. WARNING Carefully Read These Instructions Before Use R0514

Unit 24: Applications of Pneumatics and Hydraulics

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Owner s Manual / 5600 Econominder

15GAL STEEL OIL DRAIN WITH 110V PUMP

This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for AR512 series and SAE J2099 and J2210 for AR500 series

Institut für Experimentelle Immunologie und Bildgebung

TROUBLESHOOTING FLOW CHART

The On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.

If you accidentally get battery acid on your skin, flush it with lots of water

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

UNITOR VACUUM cleaners

Diesel Fuel Systems. Injection Nozzles

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Mercury is poured into a U-tube as in Figure (14.18a). The left arm of the tube has crosssectional

Click here to visit Magic Inkjet Flush.com / ebay name: Tinteiros

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Installation and maintenance instructions

Transcription:

Print Head Recovery Quick Guide with Print Head Doctor 7 WARNING: Print heads can be damaged by excessive use of ultrasound, pressure, temperature and aggressive chemicals. It is always a good idea to minimize the risk of a print head damage by using no ultrasound, low pressures, low temperatures and using less aggressive recovery fluids (1X, 1UV, 1DX, 1W). If no progress can be made this way, you can start introducing short periods of ultrasound, warming up the fluids, and using more aggressive chemicals. Print Head Sensitivity Here is the list of print heads sorted by sensitivity in an ascending order. Less sensitive print heads can handle more pressure, temperature, ultrasound and chemistry. Less sensitive heads can be cleaned starting with Step 3 below. Others should go through steps 1 and 2. If you are working with Epson heads, please read the Quick Guide for Epson head recovery with PHD4 or PHD6, as these heads are way too sensitive and require extra care. Spectra S-class (SL128, SM128, SE128) Very low sensitivity. Spectra Q-Class Spectra Nova and Galaxy Low sensitivity. Ricoh Gen4 Konica-Minolta KM512 Xaar 500 Konica-Minolta KM256 Xaar 1001 Konica-Minolta KM1024 Kyocera KJ High sensitivity. Xaar 128 HP Aprion High sensitivity. Seiko SPT510 and SPT508 Epson DX4 HP X2 Epson DX5 Hitachi (Ricoh) Gen3 Epson - all other models Canon PF-03 Page 1 of 5

Explanation of the Recovery Cycles Dr - Drain Cycle - is used to empty the tank, or when you need to pump fluids in a forward direction for a short time. Ar - Air Cycle - is used to purge the fluid out of the internal filter and tubing. Do not start Air cycle when a print head is connected, as it will over-pressurize it. C1 - Combined Normal - pumps the fluid into the print head and sucks it out of the RF cap, with 5% of ultrasonic time. C2 - Combined Easy Cycle - same as C1 but without using any ultrasound. C3 - Combined Strong Cycle - same as C1 but with more ultrasound: 30% of the cycle time. F1 - Forward Normal Cycle - only the pressure pumps will work (no vacuum), with 5% of ultrasonic time. F2 - Forward Easy Cycle - same as F1 without using any ultrasound. F3 - Forward Strong Cycle - same as F1 but with more ultrasound: 30% of the cycle time. Useful Tips Protect your print head s electronics from the fluids. Wrap the areas where fluids may get on the electronics with tape. Make sure that the print head is submerged into the fluid by only 3mm (1/8 ) and not deeper. Do not clean your print head for too long. One hour a day will be enough. Purge the print head with a weak flush and then with air, gently pushed by a syringe, and let it sit for a day without any fluids inside. Before installing the print head on your printer, test the nozzles by pushing the flushing solution that came with your ink through the print head using a syringe. Do not apply too much pressure. Once you see the nozzles are in a good condition, put the head on the printer. Otherwise you ll need to re-flush it. Do not use alcohol to clean the electronics of a print head. If you want to remove moisture from the electronic parts, use the spray-on Contact Cleaner that can be found in automotive parts stores. Precautions on Epson Heads Epson heads are extremely sensitive to everything. Follow these precautions to keep them safe during recovery, and disregard the pressure settings shown on the diagrams in this document. Epson heads cannot handle any kind of pressure applied to the input ports. Keep the print head pressure at a maximum of 3 psi. Do not use any ultrasound, as it will damage Epson heads if applied for too long. When it s absolutely necessary to use the ultrasound, keep it on for a maximum of 30 seconds. The recovery cycle to use: F2 (Forward-Easy). Do not pre-heat the recovery fluid, let it run at a room temperature. Watch the temperature: it should not get warmer than 30 C. The most effective way of cleaning Epson heads is by using a vacuum-assisted forward flushing method with the maximum forward pressure of 2 psi. There is no limit to the vacuum: it can be as high as it gets. Vacuum cannot damage print heads. Page 2 of 5

Print Head Connections for Forward Flushing 7 psi Fixed Ports Pressure pressure 7 psi Print Head Adjust pressure with Relief Valve Print Head Recovery Steps If you have a Reverse Flushing Cap for your print head, you can jump directly to the Vacuum-Assisted Forward Flushing, as it s more effective then Forward Flushing alone. Step 1. Light Flushing of Sensitive Print Heads We will attempt to unclog your print head the safest way possible. Use fluid # 1X for solvent print heads, or 1UV for UV curable, or 1W for water-based ones. Do not set the temperature, but watch it not to exceed 30 C. Set up your print head as shown on the picture. Open the relief valve. Start the Drain cycle and watch the Print Head Pressure. Using the Relief Valve, adjust the pressure to be around 6 psi. Lift the print head for a moment to see the condition of the nozzles. Stop the cycle. Start the F2 (Forward Easy) cycle and let it run for 15 minutes. Watch the pressure: it should never exceed 7 psi. Adjust it when necessary. Check the nozzles. If you see an obvious progress, continue with the forward flushing for another full F2 cycle. If no progress has been observed, move on to Step 2. Step 2. Medium Strength Flushing of Sensitive Print Heads Continue with the less aggressive recovery fluid (#1). Start F1(Forward Normal) cycle. Check the nozzles after 10 minutes. If no progress has been made, you ll need to change the recovery fluid. Follow the fluid changeover instructions. Always keep an eye on the forward pressure (7 psi max). Re-check the nozzles and if there was no progress, move on to Step 3. Step 3. Powerful Flushing of Robust Print Heads Please note that this process poses a higher risk for sensitive print heads. Run F3 (Forward Strong) cycle for a full length of it. Re-check the nozzles. If you see a great deal of improvement, repeat the F3 cycle. If no further progress is observed, change the recovery fluid to the next one, following the Fluid Changeover Instructions contained in a separate document. Repeat the F1 cycle with the new fluid. Robust print heads can handle as much as 4 hours of continuous flushing, while other heads should be flushed for no longer than 1...2 hours per day. If no improvement is taking place after each cycle, it means that the recovery fluid should be changed to another one. When you re done cleaning a print head, flush it out with fluid 1X (or a distilled water for water-based heads), and fill it with the flushing solution that comes with your ink. Page 3 of 5

Vacuum-assisted forward flushing using a Reverse Flushing cap 7psi Vacuum Pressure pressure 7 psi RF Cap Vent Hole Capped Unlimited vacuum 10-29 Hg Vacuum-Assisted Forward Flushing If you have a Reverse Flushing cap for your print head (RF cap), you can do a so-called vacuum-assisted forward flushing. The vacuum is applied to an RF cap attached to the nozzles of your print head, which sucks the fluid out of it, while pressurized fluid is supplied to the input ports of the print head. Pressure and vacuum work together to increase effectiveness of the cleaning. If you have 7 psi of pressure and 20 of vacuum (20 Hg = 10 psi), it s the same as forward flushing the head with 17 psi of pressure if there were no RF cap, without exceeding the safe pressure of 7psi. Set up your print head as show on the diagram above. Run the C1 cycle (for Epson heads use only C2 with no ultrasound). Make sure the print head pressure does not exceed 7 psi. Very sensitive print heads will get damaged at 7psi, so you should keep it at no more than 2 psi. For Epson heads, keep the pressure at 1 psi. Medium and Low sensitivity print head can be cleaned with cycle C3, which gives more ultrasound. To get the highest effectiveness out of this flushing method, replace the small filters beforehand or make sure they are clean enough not to create too much resistance to the flow. Page 4 of 5

Reverse flushing print heads using a Reverse Flushing cap 15 psi Vacuum Pressure pressure 15 psi RF Cap Vent Hole Capped Unlimited vacuum 10-29 Hg Reverse Flushing with an RF Cap If you have a Reverse Flushing cap for your print head, here is another method of cleaning heavily clogged print heads. It will run the fluid in a reverse direction, pushing the clog out of the print head as opposed to pushing it through the nozzles, as it happens during the forward flushing. Keep the vent hole capped with the screw. Run the C1 cycle (for Epson heads use only C2 with no ultrasound). Because all the pressure is applied to the outside of the nozzles, it s safe to use a high pressure of up to 15 psi. Medium and Low sensitivity print head can be cleaned with cycle C3, which gives more ultrasound. After reverse flushing like this, you should do a forward flushing, or better yet a vacuum-assisted forward flushing. Page 5 of 5