PELLEXIA COMFORT ENVIRONMENT COMPATIBLE



Similar documents
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

High-efficient gas boiler CompactGas

BIOHOUSING Seminar Success stories of biomass heating in small scale

TECHNICAL CHARACTERISTICS

ELECTRIC CENTRAL HEATING FLOW BOILER

Heating with wood chips and pellets

HEAVY DUTY STORAGE GAS

1 DESCRIPTION OF THE APPLIANCE

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW


HAPERO BALANCE / FLASH. 15 kw / 25 kw / 35 kw. Basement Floor Living room ENERGIETECHNIK GMBH PLUG INSTITUT FÜR BRANDSCHUTZTECHNIK

Electric Flow Boiler

PE1 Pellet. PE1 Pellet. Pellet boiler. PE1 Pellet.

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

ECOCIAT. Domestic hot water heat recovery unit

HIGH QUALITY COMPONENTS

Laddomat Charging unit

Natural geothermal energy.

INTEC Engineering GmbH Heating Solutions for the Marine Industry

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Installation and maintenance instructions. Danfoss Vent

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

KONRAD. Hybrid Fancoil Series

Description of functions

Solar Hot Water Heaters

Condensing Boiler Efficiency

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Power consumption (kw)

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

User's Instructions. Alpha HE CB25/33 and HE SY25

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Apartment and Communal Heating Solutions

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Commercial Gas Furnace Upflow

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

SOLAR HEATING SYSTEMS.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

The natural ombination

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

Smile. The All-In-One Heating Controller

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

HVAC Processes. Lecture 7

Link-Up. Solid Fuel Association Guide to Central Heating.

RPV - RP - RA air handling units

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

Daikin Altherma Hybrid Heat Pump

Cooking at the Speed of light!

COMMISSIONING OF HVAC SYSTEMS

UDSA - UDSBD unit heater

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

UNDERSTANDING CENTRAL HEATING SYSTEMS

Condensing unit type EPSILON-ECHOS LE Technical information manual

Daikin Altherma Hybrid Heat Pump

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

Porcia, 20 novembre 2012

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Energy Efficiency HOSPITALITY.

Vitocaldens 222-F Compact Gas-Hybrid appliance

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Gas Condensing Boilers

Standard operating procedure for Biomass boiler demonstration rig (F12c)

Providing reliable energy-efficient boilers B O I L E R S

We have been working in an ideal climate for thirty years.

EcoDesign & Labelling Directive (ErP)

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Operating instructions

ECOplus Solar Cylinder

The Concept of Condensing Boilers

Stove-boiler for solid fuels KW Directions for use and assembling

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

Drayton Digistat +2RF/+3RF

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

Energy Efficiency. Bars & RestauRants.

Technical data. Danfoss DHP-A

Solar Combisystems Changes on the market place since Task beginning

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Aludesign K A T A L O G

Oil - kerosene burners

Commercial Gas Water Heaters

Boiler & Pressure Vessel Inspection discrepancies and failures

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

COMBLOC The future of packaged multi-fuel fired steam boilers. Ultra Compact. High Performance

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

Daikin Altherma Hybrid Heat Pump

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Daikin Altherma hybrid heat pump. The natural combination

Operating instructions

Transcription:

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50 Comfort environment compatible means to use alternative energetic resources, sustainable and, at the same time, to increase the housing comfort. Inspiring itself to this principle, Unical, since always advanced in the employment of the biomasses, introduces PELLEXIA: ideal for simplicity, elevated performances and consumptions reduction. PELLEXIA is a range of hot water thermal groups with a nominal output of 7 and 40 kw, endowed with blown burner and a reservoir of pellet of 50 kg, that automatically feed it. It is produced for heating houses up to and more than 300 m. - It offers a winner alternative to the running costs of the traditional heating systems - It assures independence from the non renewable fuels. - In some country it takes advantages through the fiscal deduction on the purchasing costs, foreseen by the laws in force. High efficiency Certified efficiency 90.4% Completely automatic and programmable operation Remote control for the boiler operation from any point of the house (optional) It can be combined with solar installation Simplified cleaning Perfect combustion thanks to the blown modulating burner, on purpose designed and built. Maximum safety with anti-overheating steel coil heat exchanger Long autonomy over 3 hours at full capacity and around 6 days in domestic use

The of details Pellexia The burner Blown air Horizontal flame Automatic Modulating 8 7 kw (mod. 7) 3 39,7 kw (mod. 40) Microprocessor assisted regulation Energy saver Electronic ignition It is activated only at the first cold starting or following to a manual or unintentional turning off. Modulating burner The boiler Large water content (no hydraulic interfaces) 67 lt (mod. 7), 8 lt (mod. 40) 3 real smoke passes for a cleaner combustion and low polluting emissions, (CO mg/nm 3 at 0% of O ): 94/58 for the mod. 7 and 06/90 for the mod. 40) Thermal exchange fins with turbolators for the maximum heat transfer to the water η> 89% and up to 90.3% Facilitated cleaning thanks to: - wide access doors - removable ash tray - inspectable smoke chamber through back cleaning opening. 3 4 5-6 M 3 7. Panel board. Boiler body insulation in mineral wool 3. Automatic airvent 4. Casing upper panel 5. Casing side panel 6. Pellet hopper 7. Safety coil heat exchanger 8. Smoke chamber 9. Smoke chamber inspection opening 0. Pressure transducer. Expansion vessel. Pellet feeding screw 3. Flexible pipe for burner feeding 4. Boiler upper door 5. Safety thermostat 6. Boiler lower door 7. Thermal exchange fins with turbulators 8. Intermediate refractory stones 3 9. Ashes collecting tray 0. Bottom refractory stones. Combustion chamber bottom insulation. Burner 3. Burner sight glass M Central heating flow R Central heating return 5 4 6 7 8 8 9 0 R 9 0

3 4 8 6 3 0 0 The reservoir pellet Long autonomy 50 kg of storage, the best compromise between dimensions and autonomy The tests in our laboratories have always shown an autonomy, at the maximum output, with burner always ON, of 3 hours. At the minimum output the autonomy time extends up to 7 hours. But in the normal domestic use, exceptional cases excepted, our burner works few minutes for every hour of offered comfort, because of important environmental factors, such as the house insulation and the actual heat requirement. As a consequence the operation autonomy can achieve ca. 6 days! Ease Pellet loading through the upper opening with safety grate Automatic pellet feeding (feeding screw group) Temperature and control sensors: hopper pellet level sensor and pellet anti-clogging in the burner Easy mounting Unical pursues its green philosophy with a true quality jump for the intelligent exploitation of the renewable resources, integrated in a sole system: biomass + solar energy. So, boilers, storage water heaters, control systems and solar panels are connected for getting the maximum efficiency. In the example below, PELLEXIA (), through a plate heat exchanger, transfers its thermal energy to a special heat accumulator () for the production of domestic hot water. On the same accumulator, managed by the solar controller (8), the solar panels furnish the captured energy. Through the thermal module M 3000 S (5) it is possible to exploit the energy accumulated in the storage tank, to heat, at the same time, a low temperature floor heating system (6) and a radiators heating system (). Electronic chronothermostats ( and 9) and outer sensor (0) constantly check the level of comfort in every condition. 3 Maximum saving with the integrated systems 3 8 7 4 0 5 9 6 PELLEXIA D.H.W STORAGE TANK SOLAR COLLECTORS KIT 3 SOLAR EXPANSION VESSEL 4 THERMAL MODULE M3000S 5 FLOOR HEATING SYSTEM 6 SOLAR CIRCULATION GROUP 7 SOLAR CONTROLLER 8 MODULATING CHRONOTHERMOSTAT REGOLAFACILE 9 EXTERNAL TEMPERATURE SENSOR 0 CHRONOTHERMOSTAT ON/OFF HIGH TEMPERATURE C.H. SYSTEM D.H.W. THERMOSTATIC MIXER 3

Panel board State indicators Display Main switch Menu Boiler water safety thermostat Fuse 3 4 5 6 7 Panel board 00 MENU SET AUX AUX AUX3 AUX4 AUX5 W/O BURNER 8 9 Indicators:. Room thermostat. Chronostat under timer control 3. Igniter 4. Pellet feeding screw 5. Flame state (if it is present or absent) 6. Recirculation pump 7. Domestic hot water 8. Burner fan 9. Central heating pump Safe Control of all the hot points of the boiler Smoke temperature sensor C.H. flow temperature sensor C.H. return temperature sensor Burner safety thermostat Pellet hopper level sensor Anticlogging level sensor Practical and flexible Simplified management user menu Possibility of complete managements Integration with solar installations D.H.W. production Remote control (optional) * Up to 4 units can be controlled by Pellexia LU MA ME GI 0 3 6 9 VE SA 5 DO 8 - ESC + The boiler can also be managed through a remote control that allows to check the boiler from any point of the house, with a simple connection of four wires. This remote control allows to perform all the management and verification operations of the boiler panel board. Being endowed with room temperature sensor, it can be used also as chronothermostat. * information available at the pre-sale office. Easy Sliding messages in 4 languages (such as: pellet stock at 0% level, lack of pellet at 0% level, in order to avoid possible annoying ignition problems, cleaning to be performed, alarm for missed ignition, intervention of safety devices with clear text, for instance: pellet in exhaustion, open door.

AUX3 ESC OK MENU AUX5 AUX6 AUX7 0 I 3 Installation and transport The Pellexia boiler, to facilitate the installation, foresees: Expansion vessel (0 liters) for closed system installations, as allowed by the norms in force Safety valve (3 bar) Pressure transducer for monitoring minimum and maximum working pressure Anti-overheating safety system constituted by a built-in coil, plunged directly in the boiler water (combined with a thermal discharge safety valve, not supplied) Air vent (std. supplied) Connectors for pre-arrangement/management of C.H. and D.H.W. storage tank loading pump off anti-condensate protection kits (optional) they raise the Pellexia performances and preserve the system for long time. Pellexia is an important thermal group. Its dry weight of around half ton (477 kg for the mod. 7 and 600 kg for the mod. 40) testifies its construction without economy and its high resistance. It is delivered in 4 parts placed just in one pallet containing:. Boiler body. Packaging, containing painted parts of the pellet hopper 3. Packaging containing galvanized parts of the pellet hopper 4. Pellet loading screw 5. Pellet burner (inside the combustion chamber) 6. Panel board (inside the combustion chamber) Unical

MENU SET AUX AUX AUX3 AUX4 AUX5 W/O BURNER Dimensions - Technical Data PELLEXIA 7 PELLEXIA 40 T T7 T T4 T5 T6 T6 T3 T3 4 3 T8 5 T9 T 490 038 30 758 68 900 45 990 T 400 960 43 90. Panel board. Pellet loading screw 3. Pellet burner 4. Smoke chamber cleaning door 5. Expansion vessel T. Central heating flow (Rp ) T. Central heating return (Rp ) T3. Chimney connection T4. Bulb holder T5. Connection for thermal discharge safety valve (Rp /) T6. Safety heat exchanger connections (Rp /) T7. Air vent connection T8. Pressure switch connection T9. Safety valve connection PELLEXIA 7 40 NOMINAL OUTPUT min/max kw 8 7 3 40 GLOBAL OUTPUT max % 89 90,3 HOPPER PELLET CONTENT Kg 50 50 AUTONOMY (at min/max burner capacity) h 7/3 45,6/5,8 SMOKE TEMPERATURE min/max C /50 08/60 CO CONTENT at 0% O at min. output % < 0,006 < 0,007 CO CONTENT at 0% O at max. output % < 0,095 < 0,038 BOILER WATER CONTENT l 67 8 PELLET CONSUMPTION min/max kg/h,/6,4 3,/9,4 DUST EMISSION mg/nm 3 at 0% O 8,8 CnHm EMISSION min./max. mg/nm 3 at 0% O 7/8 /6 CO min./max. mg/nm 3 at 0% O 94/58 06/90 ELECTRIC ABSORPTION at starting W 86 86 in steady state W 6 6 MAX. WORKING PRESSURE bar 3 3 DRY WEIGHT kg 477 600 BOILER WEIGHT FILLED WITH WATER & PELLET kg 694 83 Ed. - /0 - Cod. 46434 Emissions: according to EN 303-5 Class 3 Efficiency: according to EN 303-5 Class 3

AG S.p.A. 46033 casteldario - mantova - italy - tel. +39 0376 5700 - fax +39 0376 660556 - export@unical-ag.com - www.unical.eu Unical AG declines any liability for the inaccuracies that may appear due to errors in transcription or printing. It also reserves the right to introduce those modifications to its products that it considers necessary or useful, without compromising the essential characteristics of the said products.