Engr. HIPOLITO A. LEONCIO Chairman, Electrical Safety and ESEA committee



Similar documents
Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Questions and Answers for Heating and A/C Contractors

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

What s up with Arc Flash?

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

Requirements for Electrical Installations

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010

Electrical Safety Tips. Help us keep you safe

Electrical Grounding. Appendix C

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

October Safety Subject

Understanding Arc Flash

3053 Electrical Safety Training Program Course Outline

ELECTRICAL SAFETY RISK ASSESSMENT

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Ducoterra Radiant Heating Panel Installation Manual

The Costs and Risks Associated with Improper Service and Maintenance of Electrical Systems

Litigation Services & Information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Top Commercial / Residential Electrical Requirements *

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

First Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

HOUSING QUALITY STANDARDS (HQS)

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Engineering innovation

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

City of Riverside Building & Safety Division Phone: (951)

Switchgear and Metal-Enclosed Bus

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Construction Electrical Terminology. Electricians

Title: Grounding and Bonding Rev-01

Installation Instructions for Alarm Module Kit A043F059

Evaluating Water-Damaged Electrical Equipment

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

misconceptions about arc-flash hazard assessments

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put Into Perspective Electrocutions Can Be Prevented

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Electrical Resistance Resistance (R)

Master Workplace Inspection Checklist for General Shop Safety. MASTER WORKPLACE INSPECTION CHECKLIST General Shop Safety

Evaluating Fire- and Heat-Damaged Electrical Equipment

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

Analyzing Electrical Hazards in the Workplace

Fire Protection Notice No. 9 ELECTRICAL SAFETY

Session 14 Cable Support Systems

Evaluating Water-Damaged Electrical Equipment

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Heading FACT SHEET. Overview.

Evaluating Water-Damaged Electrical Equipment

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Part 1 System Modeling & Studies for Existing Systems

Power Quality for Information Technology System

Electrocution Hazards

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Addendum #2 Contract UK-11-13

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

! WARNING Arc Flash and Shock Hazard Appropriate PPE Required

County of Riverside Building and Safety Department

Massachusetts FACE Occupational Fatality Report

Chapter 9. Bonding and Grounding

A. Shop Drawing submittals shall include, but not be limited to, the following:

Arc Flash Energy Mitigation Techniques

How To Keep An Eye On Electric Safety

NFPA 70E Updates Affect Your Most Valuable Assets

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put it into perspective: Electrocutions can be Prevented

Engineers Edge, LLC PDH & Professional Training

Fusible Disconnect Switch

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

Grounding & Bonding Why it is done And How to Install Properly

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Power Management Module 2. Installation

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS

Comparative study for cables and busbars

City Of Ottawa High Voltage Substation Inspection, Maintenance Rev July 17 and Testing, ROPEC Page 1

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Electric Service Guide for Commercial Construction

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FAQs-Main switchboard design criteria

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

Dehumidifier Users manual. For Models: DH45S DH65S

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

ELECTRICIAN TRADE REGULATION

TIG INVERTER INSTRUCTION MANUAL

BASIC NEC CODE RULES AND DESIGN PRACTICE

Bold items are particular to the City of Euless

Transcription:

Engr. HIPOLITO A. LEONCIO Chairman, Electrical Safety and ESEA committee

Republic Act 7920 An act providing for a more responsive and comprehensive regulation for the practice, licensing, and regulation of electrical engineers and electricians

Philippine Electrical Code The Philippine Electrical code is used nationally as the basis for safeguarding persons, buildings and its contents from hazards that may arise from the use of electricity. This code contains provisions which is considered necessary for safety and thus is used as basis for the legal enforcement agency in the government regarding electrical installation

ELECTRICAL SAFETY ENFORCEMENT AND AWARENESS

ESEA PROFILE February 10, 2011 MOA Signing for the 3-year Electrical Safety Enforcement and Awareness (ESEA) Campaign Project May 21, 2011 Launching of ESEA at the Institute of Integrated Electrical Engineers of the Philippines, Inc Head Office.

ESEA PROFILE June 27, 2011 President Aquino signed Proclamation No. 193 declaring the Month of May of every year thereof as the Electrical Safety Month. May 24, 2013 Addendum to the MOA was signed at Taal Vista Hotel, Tagaytay City. This is to continue the campaign on electrical Safety

PRESIDENTIAL PROCLAMATION NO. 193 DECLARING THE MONTH OF MAY OF EVERY YEAR AS THE ELECTRICAL SAFETY MONTH WHEREAS, many lives and properties are lost due to fires and electrocution

PRESIDENTIAL PROCLAMATION NO. 193 WHEREAS, most of these fires and incidents of electrocution are attributed to faulty electrical wiring

PRESIDENTIAL PROCLAMATION NO. 193 WHEREAS, economic losses brought about by fires contribute to reduced productivity and therefore affect the economy of the country

PRESIDENTIAL PROCLAMATION NO. 193 WHEREAS, there is a real need to increase public awareness on electrical safety and educate our people in the safe use of electricity.

ESEA PROFILE MISSION - To ensure ESEA is properly enforced through improving local inspectors capacity and to increase the public s awareness on electrical safety.

ESEA PROFILE VISION - To be a major campaign that leads the public towards an electrically safe environment.

ESEA PROFILE Objectives designed to enhance the enforcement of the Philippine Electrical Code (PEC); provide capacity building to improve the skills of local inspectors increase the awareness of and educate the public on the importance of electrical safety

ESEA PROFILE and strengthen the institutional cooperation between government and industry such as the local government units, developers, and contractors association, among others. Electrical Safety Starts With Me! ESEA Slogan

ESEA PROFILE and strengthen the institutional cooperation between government and industry such as the local government units, developers, and contractors association, among others. Electrical Safety Starts With Me! ESEA Slogan

ELECTRICAL SAFETY FLYER

PRIME ON ELECTRICAL INSPECTION FOR RESIDENTIAL UNITS This primer has followed the footsteps of the IIEE Inspection Guide, wherein the Institute has tapped the electrical enforcing authorities in order to come up with a series of publications that is designed to supplement the latest Philippine Electrical Code edition and Provide Guidance in applying code provisions

THE PRIMER ON PHILIPPINE ELECTRICAL CODE PART 1 This manual do not wish to fully interpret the Philippine Electrical Code, but hopefully attempts to standardize the inspection guidelines all over the country, and eventually foster a culture of Electrical Safety in the workplaces.

ELECTRICAL SAFETY ENFORCEMENT AND AWARENESS This manual is intended to inform the general public about the importance of Electrical Safety in our daily lives.

ELECTRICAL SAFETY KEY RESULT AREAS Compliance with National/Internationa l Standards Safety Workmanship Improve Power Quality Voltage Stability Arrest Surges Harmonics Attain Flexibility Reduce/Add Loads Maintain Reliability Interruption Frequency Interruption Duration Ensure Cost Effectiveness Effective Budget Cost Efficient Maintenance Program/Enercon/man Energy Savings

ELECTRICITY - THE DANGERS About 5 workers are electrocuted every week Causes 12% of young worker/people/ workplace deaths Takes very little electricity to cause harm Significant risk of causing fires 21

ELECTRICITY- THE DANGERS 38,437 Fires recorded nationwidesource BFP Average of 19 reported daily incidents

WHAT IS AN ELECTRICAL INSPECTION & AUDIT? An electrical audit is a thorough survey/ inspection, review and evaluation of an electrical system which is already in operation for several years.

WHAT IS THE PURPOSE OF AN ELECTRICAL INSPECTION & AUDIT? The purpose of an electrical safety inspection or audit is to identify potentially hazardous electrical situations and provide corrective actions for these situation.

OBJECTIVES OF ELECTRICAL INSPECTION & AUDIT - 1 # 1. Determine compliance of the electrical system to electrical safety, viz-a-viz: - Philippine Electrical Code (Part I & II) - National Electrical Code - NFPA 70E - NFPA 70B - OSHA 1910.331-335 - Other Electrical Codes (IEC)

OBJECTIVES OF AN ELECTRICAL INSPECTION & AUDIT 2,3,4 #2. Review and provide corrective actions for safe electrical work processes. # 3. Review and provide corrective measures for electrical maintenance tools. # 4. Identify efficient measures and potential cost savings through modifications/ improvements in the electrical system.

So what would be the samples of electrical violations or errors that you should be mindful of when you do your electrical audit/ inspections?

1. THE USE OF HIGHER RATED CIRCUIT PROTECTION... THIS IS A RAMPANT VIOLATION!

AS INSPECTED IN 2011, THE SIZE OF THIS SERVICE ENTRANCE FEEDER IS 2 14 SQUARE MM IN A PVC CONDUIT, SO THAT THE ALLOWABLE AMPACITY IS 70 AMPERES BUT THE PROTECTION IS 200-AMPERE FUSES! THE IIEE ESC/ESEA VOLUNTEER TEAM IN 2012 REPLACED IT WITH 100- AMPERE FUSES. 1-A. ANOTHER CASE OF USING VERY HIGH RATING OF PROTECTION..

EX.2.D UNINTENTIONALLY CREATING STRAY CURRENTS/ LOCALIZED HEATING.. This was discovered just recently on a 40-storey tower elsewhere in a central business district in Metro Manila! Note the same phase conductors in same RS Conduit. How could the site electrical engineer and/or electrical foreman made the oversight!

3. INADEQUATE EQUIPMENT GROUNDING.. WHAT WOULD BE THE MAXIMUM GROUNDING RESISTANCE? IS IT 25 OHMS? 5 OHMS? 1 OHM? THE LOWER THE VALUE, THE SAFER! WHY? GROUND FAULT CURRENT SEEKS THE PATH OF LOWER RESISTANCE.

4. NOT USING GROUNDING TYPE CONVENIENCE OUTLETS...

5. NOT USING GFCI DEVICE FOR CIRCUITS IN DAMP LOCATIONS OR EXTERIOR AREAS..

6. NOT CHECKING THE BUS BAR CAPACITY OF THE PANEL BOARDS/ BUS BAR GUTTERS..

12. FAILURE TO TEST COMPLETELY BEFORE ENERGIZATION AFTER A PROLONGED SHUTDOWN OF A SWITCHGEAR, A DANGEROUS ARC FLASH FAULT BETWEEN PHASES MAY RESULT AFTER ENERGIZATION OF THE BUS BARS! THIS MAY HAPPEN WHEN THERE IS A FAILURE TO DETERMINE THE INSULATION RESISTANCE OF THE ENCLOSED BUS BARS. AFTER A PROLONGED SHUTDOWN ON A HUMID DAY, MOISTURE MAY OCCUR DUE TO CONDENSATION INSIDE THE SWITCHGEAR. WARNING: ALWAYS MEGGER TEST CIRCUIT BREAKERS, BUS BARS, CABLE FEEDERS BEFORE ENERGIZATION! THE HIGHER THE MEGGER READING, THE SAFER!

14. USING IMPROPER SPLICES

NOTE THAT THERE ARE NO TYPE EYS CONDULET SEAL FITTINGS ON THE CONDUITS WITHIN 150MM FROM THE SWITCH BOXES. IN CLASSIFIED LOCATIONS, THE CONDUIT SEAL WOULD PREVENT THE ENTRY OF FLAMABLE GASES OR VAPORS TO THE SWITCHES WHICH ARE POSSIBLE SOURCES OF A SPARK. 15. NOT USING SEAL FITTINGS IN HAZARDOUS LOCATIONS

18. LACK OF SUPERVISION DURING CONSTRUCTION...

THE FLYING WIRES/CABLES WHICH INCLUDE POWER & COMMUNICA- TION LINES ARE INSTALLED TEMPORARILY.. UNTIL AN UNTOWARD INCIDENT HAPPEN AGGRAVATING MATTERS ACCIDENTS. 19. TEMPORARY WIRING ALLOWED TO BECOME TEMPORARY-PERMANENT

NOTE THAT THERE ARE NO TYPE EYS CONDULET SEAL FITTINGS ON THE CONDUITS WITHIN 150MM FROM THE SWITCH BOXES. IN CLASSIFIED LOCATIONS, THE CONDUIT SEAL WOULD PREVENT THE ENTRY OF FLAMABLE GASES OR VAPORS TO THE SWITCHES WHICH ARE POSSIBLE SOURCES OF A SPARK. 15. NOT USING SEAL FITTINGS IN HAZARDOUS LOCATIONS

18. LACK OF SUPERVISION DURING CONSTRUCTION...

THE FLYING WIRES/CABLES WHICH INCLUDE POWER & COMMUNICA- TION LINES ARE INSTALLED TEMPORARILY.. UNTIL AN UNTOWARD INCIDENT HAPPEN AGGRAVATING MATTERS ACCIDENTS. 19. TEMPORARY WIRING ALLOWED TO BECOME TEMPORARY-PERMANENT

NOTICE THE SERVICE ENTRANCE WIRES, NO ENTRANCE CAP OR DRIP LOOP THIS ALLOWS WATER TO ENTER CONDUIT AND MAY EVEN REACH PANELBOARD INSIDE, CAUSE DAMAGE, OR GROUND FAULT. THERE IS ALSO NO GROUND WIRE. 21.LACK OF SAFETY SENSE

THE 60A PANEL MAIN CBS ARE PLUG-IN TYPE, SHOULD BE BOLT-ON TYPE.. THE PLUG-IN MAINS WILL RESULT TO LOOSE CONNECTION, LOCALIZE HEATING.. 24.NOT USING BOLT-ON TYPE MAINS

1. REGULAR CLEANING REQUIRED. 1. CABLE TERMINATIONS ARE VIOLATIONS. 1. COLOR CODING OF WIRES MUST BE FOLLOWED. 26. LACK OF MAINTENANCE

THE ABSENCE OF THE COVER FOR THE JUNCTION BOX EXPOSES THE CONDUCTORS NOT ONLY TO WATER BUT ALSO TO THE ULTRA- VIOLET (UV) RAYS OF THE SUN, CAUSING THE DETERIORATION OF THE INSULATION OF THE CONDUCTORS FASTER. 30. JUNCTION BOX COVER MISSING..

In a big manufacturing plant, during the retrofitting or replacement of the main circuit breaker of the Low Voltage Switchgear, the panel opening is so big where in there is a large clearance between the front face of new power breaker and the panel opening. This may allow foreign bodies such as dust, and even live creatures to possibly enter inside the switchgear and cause a shutdown. A control wire is even left not tied properly. 32. PANEL COVER & POWER CBS NOT FITTED PROPERLY

The use of old fused disconnect switches where in the load side feeder wires are too small in their ampacities as matched to the rating of the fuses. The fuses may protect the small wires from high magnitude short circuit current but not on an overload current or during a low magnitude line-to-ground fault. These installations must be replaced with bus bar type panel board of power distribution to various load circuits. 33. OLD FUSED DISCONNECTS STILL IN USE?

Would you believe that this kind of cable installation still exists? If you are the electrical practitioner assigned to supervise the electrical works, how would you have provided for a better job? By providing flexible metallic conduits? By a cable duct? Or by extending the cable trench? 35. CABLES NOT PROVIDED W/ RACEWAYS..

35. POOR VENTILATION FOR HEAT GENERATING EQUIPMENT THE TRANSFORMER BELOW WHICH WAS INSTALLED INSIDE A CABINET THAT IS NOT ADEQUATELY VENTILATED OR NOT PROVIDED WITH LOUVERS SHOWS SIGNS OF EXCESSIVE HEAT BEING DISSIPATED. IT WAS SOON DAMAGED.

AS-BUILT PLANS After your thorough electrical inspection & audit, you will now prepare/ update your electrical drawings: * Lighting Layouts * Power Layouts * Panel Arrangements * Single Line Diagram/ Riser Diagram * Load Schedules and Computations * Service Entrance * Substation * Meter Center * Grounding system * Lightning Protection system * Other electrical details of the electrical system Note down all observations of non-compliance/ Code violations, unsafe situations, inefficient system/ equipment, etc

FIRE TRAGEDIES: When Would We Learn?

FIRE OCCURRENCE NATIONWIDE (2005-2010) Origin/Causes 2006 2007 2008 2009 2010 TOTAL Unknown/Others 2334 1871 2485 3395 1966 2324 14,375 Electrical 2249 2087 2300 2532 2333 2616 14,117 TAL Open Flames/Cooking Combustion/Bonfire Cigarette Butts/ Smoking 1598 1144 1726 2285 997 1280 9,030 710 538 1094 1592 392 540 4,866 324 257 349 355 132 199 1,616

Comparative Report on Fire Suppression Nationwide (January to September 2010) Combustion/Heat/ Bonfire 8% Openflames/ Cooking 17% Electrical 33% 1,942 981 Cigarette Butts/Smoking 2% Fireworks/Explosives/Spar k 1% Flammable Liquids 2% 1,962 LPG (Tanks, Stove) 3% Unkown/Others 34%

BIG FIRES: CAUSES? Manor Hotel Fire Location : Kamias Road, Quezon City Date/Time : 18 0412H August 2001 Cause of Fire: Electrical Short Circuit Casualty : 75 persons Injured : 73 Persons Est. Damages: Electrical Short Circuit The Fire was put under control in one hour and 16 minutes after the first firetruck has arrived. Most of the fatalities died of suffocation.

Fire exit at the 3rd Floor without stairs

Ozone Disco Fire Location : 57-A Timog Ave., Quezon City Date/Time : 19 2405H March 1996 Cause of Fire: Casualty : 162 persons Injured : 100 persons m/l Est. Damages: 15 Million m/l Electrical Malfunction (overloading) Electrical Malfunction (overloading)

OZONE DISCO FIRE

Be electricaly safe, not sorry!

For inquiries, please contact: ESEA Secretariat #41 Monte de Piedad St., Cubao, Quezon City 0905-375 8576 / 727 3552 loc 107 / 966 9462